Kazuo Takakuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazuo Takakuda has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Hiroo Miyairi
Tokyo Denki University
12 shared publications- Yoshihisa Koyama
Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
9 shared publications - Masanori Kikuchi
Bioceramics Group, Research Center for Macromoleclules and Biomaterials, National Institute for Materials Science, Tsukuba, Japan
8 shared publications Junzo Tanaka
6 shared publications- Takeshi Muneta
Department of Joint Surgery and Sports Medicine, Tokyo Medical and Dental University, Tokyo, Japan
6 shared publications Yoshihisa Koyama
6 shared publications
Latest Publications
- 1 August 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (6) , 2355-2360
Enhanced biological fixation of ligaments to bone tissues utilizing chitin fabrics
In ligament reconstruction involving anterior cruciate ligament surgery, biological fixation between the transferred ligament and bone tissue is critical for achieving successful outcomes. Here, we administered chitin fabrics into the bone tunnels and evaluated their efficacy in promoting biological fixation. An animal model on the rat's patellar ligament was employed. First, bone tunnels were created in the lateral condyle of the femur. The ligament was then separated from the tibial tuberosity, and half was inserted into the tunnel and fixed with the use of end button. Animals in the experimental group were treated with microfiber nonwoven chitin fabric, whereas control animals received no treatment. Specimens were collected at 2, 4, and 6 weeks after surgery, and the fixation strength was measured by mechanical tests. Histological sections were prepared from samples prepared 4 weeks after surgery, and the diameter of bone tunnel and the width ratio of collagenous tissue in the bone tunnel were measured. Administration of chitin significantly increased the mean fixation strength at 4 and 6 weeks after surgery. Furthermore, chitin also promoted bone formation in the bone tunnel and increased the density of collagen fibers. Thus, microfiber nonwoven chitin fabric enhanced the biological fixation of the ligament to the bone tissue. (C) 2017 Wiley Periodicals, Inc.
- 1 August 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (6) , 2355-2360
Enhanced biological fixation of ligaments to bone tissues utilizing chitin fabrics
In ligament reconstruction involving anterior cruciate ligament surgery, biological fixation between the transferred ligament and bone tissue is critical for achieving successful outcomes. Here, we administered chitin fabrics into the bone tunnels and evaluated their efficacy in promoting biological fixation. An animal model on the rat's patellar ligament was employed. First, bone tunnels were created in the lateral condyle of the femur. The ligament was then separated from the tibial tuberosity, and half was inserted into the tunnel and fixed with the use of end button. Animals in the experimental group were treated with microfiber nonwoven chitin fabric, whereas control animals received no treatment. Specimens were collected at 2, 4, and 6 weeks after surgery, and the fixation strength was measured by mechanical tests. Histological sections were prepared from samples prepared 4 weeks after surgery, and the diameter of bone tunnel and the width ratio of collagenous tissue in the bone tunnel were measured. Administration of chitin significantly increased the mean fixation strength at 4 and 6 weeks after surgery. Furthermore, chitin also promoted bone formation in the bone tunnel and increased the density of collagen fibers. Thus, microfiber nonwoven chitin fabric enhanced the biological fixation of the ligament to the bone tissue. (C) 2017 Wiley Periodicals, Inc.
- 5 August 2016
- Published by Springer Nature in Lasers in Medical Science
- Vol. 31 (8) , 1683-1689
Wound healing efficacy of a 660-nm diode laser in a rat incisional wound model
This study aimed to elucidate the optimum usage parameters of low reactive-level laser therapy (LLLT) in a rat incisional wound model. In Sprague-Dawley rats, surgical wounds of 15-mm length were made in the dorsal thoracic region. They were divided into groups to receive 660-nm diode laser irradiation 24 h after surgery at an energy density of 0 (control), 1, 5, or 10 J/cm2. Tissue sections collected on postoperative day 3 were stained with hematoxylin-eosin and an antibody for ED1 to determine the number of macrophages around the wound. Samples collected on day 7 were stained with hematoxylin-eosin and observed via polarized light microscopy to measure the area occupied by collagen fibers around the wound; day 7 skin specimens were also subjected to mechanical testing to evaluate tensile strength. On postoperative day 3, the numbers of macrophages around the wound were significantly lower in the groups receiving 1 and 5 J/cm2 irradiation, compared to the control and 10 J/cm2 irradiation groups (p < 0.01). The area occupied by collagen fibers in day 7 was largest in 5 J/cm2 group, followed by 1 J/cm2 group, although this difference was not significant. The day 7 tensile test demonstrated significantly greater rupture strength in healing tissues from 1 and 5 J/cm2 irradiation groups, compared to the control group (p < 0.05). Thus, LLLT with a 660-nm diode laser with energy density of 1 and 5 J/cm2 enhanced wound healing in a rat incisional wound model. However, a higher radiation energy density yielded no significant enhancement.
- 5 August 2016
- Published by Springer Nature in Lasers in Medical Science
- Vol. 31 (8) , 1683-1689
Wound healing efficacy of a 660-nm diode laser in a rat incisional wound model
This study aimed to elucidate the optimum usage parameters of low reactive-level laser therapy (LLLT) in a rat incisional wound model. In Sprague-Dawley rats, surgical wounds of 15-mm length were made in the dorsal thoracic region. They were divided into groups to receive 660-nm diode laser irradiation 24 h after surgery at an energy density of 0 (control), 1, 5, or 10 J/cm2. Tissue sections collected on postoperative day 3 were stained with hematoxylin-eosin and an antibody for ED1 to determine the number of macrophages around the wound. Samples collected on day 7 were stained with hematoxylin-eosin and observed via polarized light microscopy to measure the area occupied by collagen fibers around the wound; day 7 skin specimens were also subjected to mechanical testing to evaluate tensile strength. On postoperative day 3, the numbers of macrophages around the wound were significantly lower in the groups receiving 1 and 5 J/cm2 irradiation, compared to the control and 10 J/cm2 irradiation groups (p < 0.01). The area occupied by collagen fibers in day 7 was largest in 5 J/cm2 group, followed by 1 J/cm2 group, although this difference was not significant. The day 7 tensile test demonstrated significantly greater rupture strength in healing tissues from 1 and 5 J/cm2 irradiation groups, compared to the control group (p < 0.05). Thus, LLLT with a 660-nm diode laser with energy density of 1 and 5 J/cm2 enhanced wound healing in a rat incisional wound model. However, a higher radiation energy density yielded no significant enhancement.
- Open Access
- 1 June 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (6) , 1007-1017
Synovial mesenchymal stem cells promote healing after meniscal repair in microminipigs
- 1 June 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (6) , 1007-1017
Open AccessSynovial mesenchymal stem cells promote healing after meniscal repair in microminipigs
- 19 March 2014
- Vol. 61 (1) , 23-31
Development of oral and extra-oral endosseous craniofacial implants by using a mesh structure for connective tissue attachment.
Connective tissue attachment to a mesh structure incorporated on the surface of oral implants and extra-oral endosseous craniofacial implants (EOECI) was investigated. Two types of implants were prepared: TI and TI-Mesh. TI was composed of an upper and a lower component, both comprised of a titanium cylinder, which could be connected using a titanium screw. The composition of the TIMesh was similar, but the lower cylinder had a lateral groove that was covered with a titanium mesh. In animal experiments performed using rat calvaria, the lower component was first implanted and was left submerged for 3 weeks, then the upper component was mounted percutaneously. After an additional 2 weeks, each implant and the surrounding tissues were harvested and evaluated. Histological observations revealed collagen fibers originating from surrounding hypodermal tissues anchored to the mesh structures of the TI-Mesh whereas no such collagen fibers were observed around TI. Significantly greater values of the attachment strength, the thickness of the dermal tissue, the thickness of hypodermal tissue, and the attachment lengths were observed in TI-Mesh than those of TI. Thus connective tissue attachment with collagen fibers anchored to the mesh was achieved by incorporating mesh structures into the percutaneously placed implants.
- 19 March 2014
- Vol. 61 (1) , 23-31
Development of oral and extra-oral endosseous craniofacial implants by using a mesh structure for connective tissue attachment.
Connective tissue attachment to a mesh structure incorporated on the surface of oral implants and extra-oral endosseous craniofacial implants (EOECI) was investigated. Two types of implants were prepared: TI and TI-Mesh. TI was composed of an upper and a lower component, both comprised of a titanium cylinder, which could be connected using a titanium screw. The composition of the TIMesh was similar, but the lower cylinder had a lateral groove that was covered with a titanium mesh. In animal experiments performed using rat calvaria, the lower component was first implanted and was left submerged for 3 weeks, then the upper component was mounted percutaneously. After an additional 2 weeks, each implant and the surrounding tissues were harvested and evaluated. Histological observations revealed collagen fibers originating from surrounding hypodermal tissues anchored to the mesh structures of the TI-Mesh whereas no such collagen fibers were observed around TI. Significantly greater values of the attachment strength, the thickness of the dermal tissue, the thickness of hypodermal tissue, and the attachment lengths were observed in TI-Mesh than those of TI. Thus connective tissue attachment with collagen fibers anchored to the mesh was achieved by incorporating mesh structures into the percutaneously placed implants.
- 24 February 2014
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 102 (4) , 674-680
Laser perforated accordion nerve conduit of poly(lactide‐co‐glycolide‐co‐ɛ‐caprolactone)
Accordion nerve conduit of poly(lactide‐co‐glycolide‐co‐ε‐caprolactone) with perforations was developed by excimer laser processing. We evaluated its in vivo function for nerve repairing and discussed the influence of pore size and density. It was found that perforations help inner nerve regeneration remarkably, which effect is unrelated to pore size or density, and is not parallel with revascularization increment. Inducing of permeability only to allow substance exchange but not vessel ingrowth could facilitate nerve regeneration too. Perforating micropores with the size of 100 μm and the density of 25/cm provides permeability and vessel ingrowth both, therefore promotes the axon extension the best, larger, and more pores do not advance axon regeneration more. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 674–680, 2014.
- 24 February 2014
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 102 (4) , 674-680
Laser perforated accordion nerve conduit of poly(lactide‐co‐glycolide‐co‐ɛ‐caprolactone)
Accordion nerve conduit of poly(lactide‐co‐glycolide‐co‐ε‐caprolactone) with perforations was developed by excimer laser processing. We evaluated its in vivo function for nerve repairing and discussed the influence of pore size and density. It was found that perforations help inner nerve regeneration remarkably, which effect is unrelated to pore size or density, and is not parallel with revascularization increment. Inducing of permeability only to allow substance exchange but not vessel ingrowth could facilitate nerve regeneration too. Perforating micropores with the size of 100 μm and the density of 25/cm provides permeability and vessel ingrowth both, therefore promotes the axon extension the best, larger, and more pores do not advance axon regeneration more. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 674–680, 2014.
- 2 April 2013
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101B (6) , 1031-1038
Hydroxyapatite/collagen nanocomposite‐coated titanium rod for achieving rapid osseointegration onto bone surface
This article proposes less‐invasive subperiosteal bone‐bonding devices capable of realizing rapid osseointegration and the acquisition of fundamental knowledge required for their development. Three candidates were prepared: titanium rod specimens with a machined surface (Bare), hydroxyapatite (HAp) coating, and hydroxyapatite/collagen (HAp/Col) nanocomposite coating. To investigate bone formation around these rods, each specimen was placed under the periosteum of a male Sprague‐Dawley rat calvarium. Four weeks after surgery, the samples were evaluated via histomorphometrical analyses and bonding strength tests. All the Bare specimens and more than half of the HAp specimens were encapsulated with fibrous tissue, whereas all the HAp/Col specimens were almost completely surrounded by new bone tissue without encapsulation. Histomorphometrical analyses showed that the HAp/Col group had the greatest bone contact ratio among all candidates (p < 0.05). Further, a bonding strength test indicated that the HAp/Col group exhibited the greatest bonding strength to bone (p < 0.05). Thus, HAp/Col‐coated rods are considered as the best candidate materials for achieving rapid osseointegration onto a bone surface. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
- 2 April 2013
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101B (6) , 1031-1038
Hydroxyapatite/collagen nanocomposite‐coated titanium rod for achieving rapid osseointegration onto bone surface
This article proposes less‐invasive subperiosteal bone‐bonding devices capable of realizing rapid osseointegration and the acquisition of fundamental knowledge required for their development. Three candidates were prepared: titanium rod specimens with a machined surface (Bare), hydroxyapatite (HAp) coating, and hydroxyapatite/collagen (HAp/Col) nanocomposite coating. To investigate bone formation around these rods, each specimen was placed under the periosteum of a male Sprague‐Dawley rat calvarium. Four weeks after surgery, the samples were evaluated via histomorphometrical analyses and bonding strength tests. All the Bare specimens and more than half of the HAp specimens were encapsulated with fibrous tissue, whereas all the HAp/Col specimens were almost completely surrounded by new bone tissue without encapsulation. Histomorphometrical analyses showed that the HAp/Col group had the greatest bone contact ratio among all candidates (p < 0.05). Further, a bonding strength test indicated that the HAp/Col group exhibited the greatest bonding strength to bone (p < 0.05). Thus, HAp/Col‐coated rods are considered as the best candidate materials for achieving rapid osseointegration onto a bone surface. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Conference on Frontiers in Bioengineering
- Vol. 2013.24, 151-152
B224 Effect of Dynamic Loading on Bone Tissues around Implants
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Conference on Frontiers in Bioengineering
- Vol. 2013.24, 151-152
B224 Effect of Dynamic Loading on Bone Tissues around Implants
- 20 December 2012
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101B (4) , 553-559
Mechanical attachment of soft tissue to dental and maxillofacial implants with mesh structures: An experiment in percutaneous model
- 20 December 2012
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101B (4) , 553-559
Mechanical attachment of soft tissue to dental and maxillofacial implants with mesh structures: An experiment in percutaneous model
- Open Access
- 19 April 2011
- Published by IntechOpen
Synthesis of Hydroxyapatite/Collagen Bone-Like Nanocomposite and Its Biological Reactions
- 19 April 2011
- Published by IntechOpen
Open AccessSynthesis of Hydroxyapatite/Collagen Bone-Like Nanocomposite and Its Biological Reactions
- 17 March 2010
- Published by Wiley in Microsurgery
- Vol. 30 (6) , 494-501
Bioabsorbable device for small‐caliber vessel anastomosis
Although the devices for large‐caliber vessel (>2‐mm diameter) anastomosis are available, there are no devices for performing anastomosis of small‐caliber vessels. We designed a hooked device composed of a bioabsorbable polymer for sutureless anastomosis of small‐caliber vessels. The efficacy of this device was evaluated by in vitro degradation and arterial‐fixation strength tests as well as in vivo transplantation experiments with common carotid arteries of growing SD rats. A nonabsorbable device without hooks served as the control in the fixation strength and animal experiments. The tensile strength of the bioabsorbable device decreased to 27 and 9% of the initial value after 8‐ and 24‐week incubation, respectively. The fixation strength was greater and the anastomotic time was shorter with this device than with the control. The transplantation experiments showed complete endothelial bridging in both devices at 2 weeks after surgery (n = 6). The control device created a considerable protrusion into the arterial lumen at 8 postoperative weeks, whereas the experimental device did not (n = 6). Arterial diameter measurements detected a significant difference between the inner diameters at the respective anastomotic sites (n = 6, P < 0.05) and demonstrated that the control device hindered the vessel growth while the experimental device did not. Therefore, the bioabsorbable hooked device was an effective tool for anastomosis of small‐caliber arteries (ca. 1‐mm diameter). © 2010 Wiley‐Liss, Inc. Microsurgery 30:494–501, 2010.
- 17 March 2010
- Published by Wiley in Microsurgery
- Vol. 30 (6) , 494-501
Bioabsorbable device for small‐caliber vessel anastomosis
Although the devices for large‐caliber vessel (>2‐mm diameter) anastomosis are available, there are no devices for performing anastomosis of small‐caliber vessels. We designed a hooked device composed of a bioabsorbable polymer for sutureless anastomosis of small‐caliber vessels. The efficacy of this device was evaluated by in vitro degradation and arterial‐fixation strength tests as well as in vivo transplantation experiments with common carotid arteries of growing SD rats. A nonabsorbable device without hooks served as the control in the fixation strength and animal experiments. The tensile strength of the bioabsorbable device decreased to 27 and 9% of the initial value after 8‐ and 24‐week incubation, respectively. The fixation strength was greater and the anastomotic time was shorter with this device than with the control. The transplantation experiments showed complete endothelial bridging in both devices at 2 weeks after surgery (n = 6). The control device created a considerable protrusion into the arterial lumen at 8 postoperative weeks, whereas the experimental device did not (n = 6). Arterial diameter measurements detected a significant difference between the inner diameters at the respective anastomotic sites (n = 6, P < 0.05) and demonstrated that the control device hindered the vessel growth while the experimental device did not. Therefore, the bioabsorbable hooked device was an effective tool for anastomosis of small‐caliber arteries (ca. 1‐mm diameter). © 2010 Wiley‐Liss, Inc. Microsurgery 30:494–501, 2010.