FVFrank D. Vrionis

Frank D. Vrionis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Frank D. Vrionis has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Kamran Aghayev

    Department of Neuro-Oncology, H. Lee Moffitt Cancer Center and Research Institute, Morsani College of Medicine, University of South Florida, Tampa, Florida; and

    4 shared publications
  • Matthias Setzer

    Department of Neurosurgery, J.W. Goethe University, Frankfurt am Main, Germany

    4 shared publications
  • Mohammed Eleraky

    Department of Neuro‐Oncology, H. Lee Moffitt Cancer Center, Florida

    4 shared publications
  • Kamran Aghayev

    Department of Neurosurgery, Biruni University, Istanbul, Turkey

    3 shared publications
  • Sabrina A. Gonzalez-Blohm

    University of South Florida College of Engineering, H. Lee Moffitt Cancer Center & Research Institute, Tampa, Florida

    3 shared publications
  • Ali A. Baaj

    Department of Neuro‐Oncology, H. Lee Moffitt Cancer Center, Florida

    2 shared publications

Latest Publications

  • Transdiscal mid- and upper thoracic vertebroplasty: first description of 2 exemplary cases

    byĀ Andreas K. Filis, Kamran Aghayev, Bernhard Schaller, Jennifer Luksza, Frank D. Vrionis

    Kyphoplasty and vertebroplasty are established treatment methods to reinforce fractured vertebral bodies. In cases of previous pedicle screw instrumentation, vertebral body cannulation may be challenging. The authors describe, for the first time, an approach through the adjacent inferior vertebra and disc space in the thoracic spine for cement augmentation. A 78-year-old woman underwent posterior fusion with pedicle screws after vertebrectomy and reconstruction with cement and Steinmann pins for a pathological T-7 fracture. Two months later she developed a compression fracture of the vertebral body at the lower part of the construct, and a vertebroplasty was performed. Because a standard transpedicular route was not available, an inferior transdiscal trajectory was used for the cement injection. A 73-year-old man with a history of rheumatoid arthritis underwent cervicothoracic fusion posteriorly for subluxation. He developed pain in the upper thoracic area, and the authors performed a transdiscal vertebroplasty at T-2. The standard transpedicular route was not possible. The vertebral body was satisfactorily filled up with cement. Clinically both patients benefited significantly in terms of back pain and showed an uneventful follow-up of 3 months. Transdiscal vertebroplasty can achieve good results in the mid- and upper thoracic spine when a standard transpedicular trajectory is not possible, and can therefore be a good alternative in select cases.


  • Open Access

    Robotics in Neurosurgery: Evolution, Current Challenges, and Compromises

    byĀ James J. Doulgeris, Sabrina A. Gonzalez-Blohm, Andreas K. Filis, Thomas M. Shea, Kamran Aghayev, Frank D. Vrionis

    Advances in technology have pushed the boundaries of neurosurgery. Surgeons play a major role in the neurosurgical field, but robotic systems challenge the current status quo. Robotic-assisted surgery has revolutionized several surgical fields, yet robotic-assisted neurosurgery is limited by available technology. The literature on the current robotic systems in neurosurgery and the challenges and compromises of robotic design are reviewed and discussed. Several robotic systems are currently in use, but the application of these systems is limited in the field of neurosurgery. Most robotic systems are suited to assist in stereotactic procedures. Current research and development teams focus on robotic-assisted microsurgery and minimally invasive surgery. The tasks of miniaturizing the current tools and maximizing control challenge manufacturers and hinder progress. Furthermore, loss of haptic feedback, proprioception, and visualization increase the time it takes for users to master robotic systems. Robotic-assisted surgery is a promising field in neurosurgery, but improvements and breakthroughs in minimally invasive and endoscopic robotic-assisted surgical systems must occur before robotic assistance becomes commonplace in the neurosurgical field.


  • Intramedullary Spinal Cord Tumors

    byĀ Kamran Aghayev, Frank Vrionis

    • 24 July 2014
      • Vol.Ā 17 Ā (4) , 317-27

    Treatment of metastatic spinal lesions with a navigational bipolar radiofrequency ablation device: a multicenter retrospective study.

    byĀ Praveen R Anchala, Winston D Irving, Travis J Hillen, Michael V Friedman, Bassem A Georgy, Douglass M Coldwell, Nam D Tran, Frank D Vrionis, Allan Brook, Jack W Jennings

    Spinal metastatic lesions are a common occurrence among oncology patients and contribute to significant morbidity. Treatment options have been limited in their effectiveness and scope to this point. This study aims to report the safety and efficacy of radiofrequency ablation (RFA) of malignant spinal lesions using a novel RFA bipolar tumor ablation system which includes a navigational electrode containing 2 active thermocouples. IRB approved multicenter retrospective review of patients receiving RFA as a treatment of metastatic osseous lesions between March 2012 and March 2013. This study consists of patients from 5 large academic centers. One hundred twenty-eight metastatic lesions were identified in 92 patients who underwent a total of 96 procedures. Cement augmentation was performed when the vertebral body was at risk or had a pathological fracture. Visual analogue scale (VAS) scores were obtained preoperatively as well as postoperatively at the one week, one month, and 6 month time points. Interval change in the patients' pain medications was recorded. Postoperative imaging was used to assess tumor burden at the treated level when available. RFA was technically successful in all of the lesions without complication or thermal injury. Our study demonstrated significant (P < 0.01) decreases in the VAS scores at one week, one month, and 6 months postoperatively. In our largest center, 54% of our patients experienced a decrease and 30% had no change in their pain medications postoperatively. Sixty-two percent of the spinal lesions in this largest institution were located in the posterior vertebral body. Post-ablation imaging confirmed size of ablation zones consistent with that measured by the thermocouples. The main limitations of this study are the heterogeneous patient population, data set, and potential confounding variable of concurrent cement augmentation. The STAR System is an RFA device that was safely and effectively used in the treatment of spine metastatic osseous lesions. This new device allows RFA treatment of previously untreatable lesions with resultant reduction in pain that was not controlled by systemic or radiation therapy.


  • Axial rotation mechanics in a cadaveric lumbar spine model: a biomechanical analysis

    byĀ James J. Doulgeris, Sabrina A. Gonzalez-Blohm, Kamran Aghayev, Thomas M. Shea, William E. Lee, Daniel P. Hess, Frank D. Vrionis


  • Open Access

    Spinal Oncology: An Innovative Field of Its Own?

    byĀ Frank D. Vrionis


  • Comparative analysis of posterior fusion constructs as treatments for middle and posterior column injuries: An in vitro biomechanical investigation

    byĀ James J. Doulgeris, Kamran Aghayev, Sabrina A. Gonzalez-Blohm, Michael Del Valle, Jason Waddell, William E. Lee, Frank D. Vrionis


  • Biomechanical comparison of anterior cervical spine instrumentation techniques with and without supplemental posterior fusion after different corpectomy and discectomy combinations

    byĀ Matthias Setzer, Mohamed Eleraky, Wesley M. Johnson, Kamran Aghayev, Nam D. Tran, Frank D. Vrionis

    Object: The objective of this study was to compare the stiffness and range of motion (ROM) of 4 cervical spine constructs and the intact condition. The 4 constructs consisted of 3-level anterior cervical discectomy with anterior plating, 1-level discectomy and 1-level corpectomy with anterior plating, 2-level corpectomy with anterior plating, and 2-level corpectomy with anterior plating and posterior fixation. Methods: Eight human cadaveric fresh-frozen cervical spines from C2–T2 were used. Three-dimensional motion analysis with an optical tracking device was used to determine motion following various reconstruction methods. The specimens were tested in the following conditions: 1) intact; 2) segmental construct with discectomies at C4–5, C5–6, and C6–7, with polyetheretherketone (PEEK) interbody cage and anterior plate; 3) segmental construct with discectomy at C6–7 and corpectomy of C-5, with PEEK interbody graft at the discectomy level and a titanium cage at the corpectomy level; 4) corpectomy at C-5 and C-6, with titanium cage and an anterior cervical plate; and 5) corpectomy at C-5 and C-6, with titanium cage and an anterior cervical plate, and posterior lateral mass screw-rod system from C-4 to C-7. All specimens underwent a pure moment application of 2 Nm with regards to flexion-extension, lateral bending, and axial rotation. Results: In all tested motions the statistical comparison was significant between the intact condition and the 2-level corpectomy with anterior plating and posterior fixation construct. All other statistical comparisons between the instrumented constructs were not statistically significant except between the 3-level discectomy with anterior plating and the 2-level corpectomy with anterior plating in axial rotation. There were no statistically significant differences between the 1-level discectomy and 1-level corpectomy with anterior plating and the 2-level corpectomy with anterior plating in any tested motion. There was also no statistical significance between the 3-level discectomy with anterior plating and the 2-level corpectomy with anterior plating and posterior fixation. Conclusions: This study demonstrates that segmental plate fixation (3-level discectomy) affords the same stiffness and ROM as circumferential fusion in 2-level cervical spine corpectomy in the immediate postoperative setting. This obviates the need for staged circumferential procedures for multilevel cervical spondylotic myelopathy. Given that the posterior segmental instrumentation confers significant stability to a multilevel cervical corpectomy, the surgeon should strongly consider the placement of segmental posterior instrumentation to significantly improve the overall stability of the fusion construct after a 2-level cervical corpectomy.


  • Aquaporin-4 expression is not elevated in mild hydrocephalus

    by Kamran Aghayev, Ercan Bal, Tural Rahimli, Melike Mut, Serdar Balcı, Frank Vrionis, Nejat Akalan

    Aquaporin-4 (aqp-4) is a member of water channel family proteins primarily expressed in the central nervous system. Physiologically it is the main channel providing water transport into the nervous system water compartments and across the blood–brain barrier. Several studies demonstrated its compensatory role in severe hydrocephalus. However, its role is not clear during the initial stages of hydrocephalus. This study was designed to investigate aqp-4 expression in less severe forms of hydrocephalus and to determine its role in disease progression. Twenty-five male Wistar-Hannover rats, were distributed into experimental (n = 20) and control (n = 5) groups. Hydrocephalus was induced in the experimental group by injection of 5 μl 25% kaolin suspension into the cisterna magna. Control animals received an injection of 5 μl normal saline. Eight weeks later, the animals were killed by the perfusion-fixation method. Immunohistochemical and Western blot analysis were performed. Ventricular dilatations were noted in all experimental animals. Both groups demonstrated positive immunoreactive signals to aqp-4. Immunohistochemically there were no changes in aqp-4 pattern and expression intensity between experimental and control animals. Similarly, Western blot analysis revealed mean aqp-4 values in experimental and control groups as 0.3436 and 0.3917, respectively, and the difference did not reach statistical significance (p > 0.05). Our results indicate that aqp-4 is not up-regulated during the initial stages of hydrocephalus. This implies that aqp-4 may not play a significant role in hydrocephalus compensation until severe ventricular dilatation occurs.