BCBalkan Cakir

Balkan Cakir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Balkan Cakir has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • René Schmidt

    Department of Orthopaedic and Trauma Surgery, University Medical Center Mannheim, Mannheim, Germany

    7 shared publications
  • Marcus Richter

    Spine Unit, St. Josefs Hospital, Wiesbaden, Germany

    5 shared publications
  • Wolfhart Puhl

    4 shared publications
  • Wolfram Käfer

    From the Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany; †Department of Neurosurgery, Hospital Sáo Vicente de Paulo, Passo Fundo, Brazil; and ‡Department of Traumatology, Klinik am Eichert, Göppingen, Germany

    4 shared publications
  • Heiko Reichel

    Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany

    3 shared publications
  • Thomas Mattes

    From the Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany; †Department of Neurosurgery, Hospital Sáo Vicente de Paulo, Passo Fundo, Brazil; and ‡Department of Traumatology, Klinik am Eichert, Göppingen, Germany

    2 shared publications

Latest Publications

  • Annuncements for issue 22-1-2013

    by Kelly R Wade, Peter A Robertson, Neil D Broom, Margareta Nordin, New York, Jeremy Fairbank, Paul Pynsent, B Cakir

  • Open Access

    Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety

    by Juraj Artner, Balkan Cakir, Sebastian Weckbach, Heiko Reichel, Friederike Lattig

    Image guided spinal injections are successfully used in the management of low back pain and sciatica. The main benefit of CT-guided injections is the safe, fast and precise needle placement, but the radiation exposure remains a serious concern. The purpose of the study was to test a new institutional low-dose protocol for CT-guided periradicular injections in lumbar spine to reduce radiation exposure while increasing accuracy and safety for the patients.


  • Resect or not to resect: the role of posterior longitudinal ligament in lumbar total disc replacement

    by Balkan Cakir, Marcus Richter, Werner Schmoelz, René Schmidt, Heiko Reichel, Hans Joachim Wilke

    With regard to the literature, several factors are considered to have an impact on postoperative mobility after lumbar total disc replacement (TDR). As TDR results in a distraction of the ligamentous structures, theoretically the postoperatively disc height and ligamentous integrity have also an influence on biomechanics of a treated segment. The purpose of the study was to evaluate the influence of posterior longitudinal ligament (PLL) resection and segmental distraction on range of motion (ROM). Six human, lumbar spines (L2–L3) were tested with pure moments of ±7.5 Nm in a spine loading apparatus. The ROM was determined in all three motion planes. Testing sequences included: (1) intact state, (2) 10 mm prosthesis (PLL intact), (3) 10 mm prosthesis (PLL resected), (4) 12 mm prosthesis (PLL resected). The prosthesis used was a prototype with a constrained design using the ball-and-socket principle. The implantation of the 10 mm prosthesis already increased the disc height significantly (intact: 9.9 mm; 10 mm prosthesis: 10.6 mm; 12 mm prosthesis: 12.7 mm). Compared to the intact status, the implantation of the 10 mm prosthesis resulted in an increase of ROM for flexion/extension (8.6° vs 10.8°; P = 0.245) and axial rotation (2.9° vs 4.5°; P = 0.028), whereas lateral bending decreased (9.0° vs 7.6°; P = 0.445). The resection of the PLL for the 10 mm prosthesis resulted in an increase of ROM in all motion planes compared to the 10 mm prosthesis with intact PLL (flexion/extension: 11.4°, P = 0.046; axial rotation: 5.1°, P = 0.046; lateral bending: 8.6°, P = 0.028). The subsequent implantation of a 12 mm prosthesis, with resected PLL, resulted in a significant decrease of ROM in all motion planes compared to the 10 mm prosthesis with intact PLL (flexion/extension: 8.4°, P = 0.028; axial rotation: 3.3°, P = 0.028; lateral bending: 5.1°, P = 0.028). Compared to the intact status, the 12 mm prosthesis with resected PLL only decreased lateral bending significantly while the 10 mm prosthesis with intact PLL increased axial rotation significantly. The resection of the PLL during TDR results in a significant increase of ROM in all three principle motion planes. But it still remains unclear if this increase which is in median not more than 1° may alter the clinical results. Moreover, the destabilizing effect of PLL resection can be reversed using a higher implant. The prosthesis height seems more crucial than PLL preservation to maintain the primary stability after TDR.


  • Adjacent Segment Mobility After Rigid and Semirigid Instrumentation of the Lumbar Spine

    by Balkan Cakir, Charles Carazzo, René Schmidt, Thomas Mattes, Heiko Reichel, Wolfram Käfer

    Study Design. Retrospective radiographic analysis of lumbar spine range of motion (ROM) after monosegmental fusion and posterior dynamic stabilization at the level L4–L5. Objective. Comparison of segmental ROM at the index level and the cranial and caudal adjacent levels and of global lumbar spine ROM after monosegmental fusion and posterior dynamic stabilization. Summary of Background Data. The postulated advantage of nonfusion technology compared with fusion is based on the assumption that preservation of motion at the treated segment reduces the incidence of adjacent segment effects. Therefore, it is imperative to provide evidence that dynamic stabilization devices avoid hypermobility at the adjacent segments because this might substantiate a protective effect on the adjacent segments. Methods. Twenty-six patients with low back pain and claudication due to degenerative instability at the level L4–L5 with concomitant spinal stenosis were treated either with decompression and Dynesys (n = 11) or with decompression and fusion (n = 15). All patients underwent flexion/extension radiographs before surgery and at latest follow-up. ROM was assessed at the index level (L4–L5), the cranial/caudal adjacent levels (L3–L4/L5–S1), and at the lumbar spine from L2 to S1. Results. There was a significant reduction of the global ROM of the lumbar spine (L2–S1) and the segmental ROM at the index level (L4–L5) in the fusion group, whereas adjacent level ROM did not change significantly. In the Dynesys group, no significant changes of global lumbar spine ROM (L2–S1) and segmental ROM (index level and cranial/caudal adjacent levels) were seen. Conclusion. This study shows that neither monosegmental instrumented fusion nor monosegmental posterior dynamic stabilization with Dynesys alter the ROM of the cranial and caudal adjacent levels. Consequently, monosegmental posterior dynamic stabilization with Dynesys has no effect with regard to adjacent segment mobility compared with monosegmental fusion.


  • Index Level Mobility After Total Lumbar Disc Replacement

    by Balkan Cakir, René Schmidt, Thomas Mattes, Christian R. Fraitzl, Heiko Reichel, Wolfram Käfer

    Analysis of segmental and total lumbar range of motion (ROM) before and after total lumbar disc replacement. To examine the relationship between absolute segmental and total lumbar ROM and evolution of ROM on clinical outcome. At the moment, data are scarce with regard to the evolution of total lumbar ROM (t-ROM) and segmental ROM (s-ROM) after total lumbar disc replacement. Moreover, the influence of ROM on clinical outcome still is unclear and remains a matter of controversial debate. METHODS.: Forty patients operated on for mono- or bisegmental symptomatic degenerative disc disease with a total of 45 artificial discs (ProDisc-L, Synthes) were analyzed. Pre- and postoperative s-ROM and t-ROM were measured on flexion/extension radiographs. The Oswestry Low Back Pain Disability Questionnaire and the Short Form 36 Health Survey were obtained pre- and postoperatively with a minimum follow-up of 3 years (37-64 months). Neither the s-ROM (pre-/postoperatively: 6.9 degrees/7.3 degrees) nor the t-ROM (pre-/postoperatively: 34.9 degrees/35.8 degrees) did change significantly after implantation of an artificial disc. Postoperatively, there was an increase of s-ROM (t-ROM) in 40% (40%), a decrease in 35% (30%), and no change in 25% (30%) of the patients. A significant inferior clinical outcome only was observed in patients with decreased t-ROM. The resulting postoperatively s-ROM had no significant impact on outcome. Neither the absolute s-ROM nor the evolution of s-ROM (increase, decrease, unchanged) was positively correlated with better clinical outcome. Although a positive correlation was observed with regard to t-ROM.


  • Operative Therapie an der Halswirbelsäule bei rheumatoider Arthritis

    by B. Cakir, W. Käfer, H. Reichel, R. Schmidt

    Zusammenfassung Die Halswirbelsäule ist häufig bei rheumatoider Arthritis befallen. Dabei kann es neben destruktiven Veränderungen zu Instabilitäten kommen, welche bevorzugt im oberen HWS-Bereich auftreten. Typische Symptome fehlen, sodass routinemäßige Röntgenuntersuchungen notwendig sind, um schwerwiegende Folgen bis hin zum letalen Ausgang zu vermeiden. HWS in 2 Ebenen und seitliche Röntgenfunktionsaufnahmen stellen dabei den Standard dar. Befundabhängig muss eine weiterführende neurologische und kernspintomographische Diagnostik eingeleitet werden. Ziel stellt das frühzeitige Erkennen bzw. die Vermeidung einer Myelopathie dar. Die Therapie besteht befundabhängig sowohl aus konservativen als auch operativen Maßnahmen.


  • Evaluation of Lumbar Spine Motion With Dynamic X-ray–A Reliability Analysis

    by Balkan Cakir, Marcus Richter, Wolfram Käfer, Michael Wieser, Wolfhart Puhl, René Schmidt

    Radiologic evaluation of lumbar range of motion (ROM) with dynamic radiograph. To calculate 95% confidence intervals (CIs) for the measurement error accompanying different methods, different observers, and different levels of training when measuring sagittal plane segmental ROM in lumbar spine. In addition, to compare the 95% CI with frequently common statistical methods of reliability analysis. Dynamic radiographs are commonly used for ROM calculation of the lumbar spine. Yet, the reliability of different measurement methods still remains unclear. In 24 patients, levels L4-L5 and L5-S1 were measured with the Cobb and superimposition methods on flexion-extension radiographs. There were 2 experienced and 1 inexperienced observer that performed the measurements. The 95% CIs were compared with the corresponding Pearson correlation coefficient and P value (t test). The 95% CI of the superimposition method was +/-4.0 degrees for the experienced and +/-4.7 degrees for the inexperienced observer. The corresponding values for the Cobb method was +/-4.2 degrees for the experienced and +/-6.8 degrees for the inexperienced observer. The 95% CI for the measurement error became even worse when different methods or observers were compared, whereas a method constancy revealed superior reliability than observer constancy in experienced observers. For lumbar ROM measurement with dynamic radiograph, the superimposition method seems to be more reliable than the Cobb method. Study protocols dealing with ROM measurement have to calculate the 95% CI of the measurement method used because clinically valid conclusions can only be drawn with respect to these intervals.


  • Open Access

    Reliability of motion measurements after total disc replacement: the spike and the fin method

    by Balkan Cakir, Marcus Richter, Wolfhart Puhl, René Schmidt

    As motion preservation is one of the main postulated advantages after total disc replacement (TDR) of the lumbar spine, the quantification of the mobility after TDR seems of special clinical interest. Yet, the best method to assess range of motion (ROM) after TDR remains unclear. The aim of the study was the calculation of 95%-confidence intervals (95%-C.I.) for the measurement error accompanying: (1) different methods (2) different observers and (3) different levels of training for radiographic motion analysis after TDR. In 12 patients the level L4-L5 and in another 12 patients level L5-S1 were measured with the Cobb and the superimposition method on flexion-extension X-rays after monosegmental TDR. Both methods were adopted as the landmarks used the spikes of the prosthesis instead the endplates (spike method) and the fin of the prosthesis instead the whole vertebral body (fin method). Measurements were performed by two experienced (O-I and O-III) and one inexperienced observer (O-II). The adopted spike and fin method showed a better reliability compared to the reported results of the original Cobb and superimposition method. The method used was not clinically relevant for the intraobserver reliability in the experienced observer (95%-C.I.: +/-2.0 degrees for the fin and +/-2.1 for the spike method) and for the interobserver reliability for two experienced observers (95%-C.I.: -2.8 degrees /+2.8 degrees for the fin and -2.9 degrees /+3.1 degrees for the spike method). The intraobserver reliability for the inexperienced observer was inferior for both methods compared to the experienced observer but no clinically relevant differences could be observed in interobserver reliability measures. The spike and fin method are reliable methods for study protocols dealing with angular motion after TDR as clinically valid conclusions can be drawn with an accuracy of about +/-2 degrees for the same observer and with an accuracy of about +/-3 degrees for a different observer.


  • The impact of total lumbar disc replacement on segmental and total lumbar lordosis

    by Balkan Cakir, Marcus Richter, Wolfram Käfer, Wolfhart Puhl, René Schmidt


  • Efficacy and cost effectiveness of harmonic scalpel compared with electrocautery in posterior instrumentation of the spine

    by Balkan Cakir, Benjamin Ulmar, René Schmidt, Georg Kelsch, Peter Geiger, Hans-Hinrich Mehrkens, Wolfhart Puhl, Marcus Richter

    Different methods to reduce blood loss during spinal surgery have been described already. Although the use of the harmonic scalpel (HS), an ultrasonically activated coagulator, has been described in endoscopic spinal surgery, its efficacy in posterior instrumentation of the spine remains unclear. The aim of this study was to determine if blood loss was lower using the HS than electrocauterization (EC) and to evaluate the cost effectiveness of the HS in reducing the need for transfusion in patients undergoing posterior instrumentation of the spine. The two groups were matched in a blinded manner, without knowledge of blood loss and were similar with respect to mean age, diagnosis and operation data. All instrumentations were done by the same surgeon. After matching was completed (HS group n=50, EC group n=50) blood loss and overall costs for blood products were analyzed by independent observers. The following were significantly lower with the HS than with EC: (1) blood loss (1106±985 ml vs 2176±1764 ml, PP=0.001), (3) average cost of blood products (€72 vs €219, PP=0.002) and red blood cells (0.38±0.75 vs 0.88±1.1 U, P=0.009). The overall costs, including the costs for the HS, remained neutral. The use of the HS in posterior spinal surgery leads to significantly lower blood loss, and less need for and cost of blood products, compared to EC in cases with major anticipated blood loss.