RPRobert Pflugmacher

Robert Pflugmacher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Pflugmacher has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • R. Bornemann

    Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn

    6 shared publications
  • D. C. Wirtz

    Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn

    5 shared publications
  • D. Wirtz

    Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn

    4 shared publications
  • K. Kabir

    Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn

    4 shared publications
  • Rahel Bornemann

    Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn

    4 shared publications
  • K. Sander

    Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn

    3 shared publications

Latest Publications

  • Radiofrequenzablation: Temperaturverteilung im angrenzenden Gewebe

    by Rahel Bornemann, S. F. Grötz, P. H. Pennekamp, K. E. Wilhelm, K. Sander, D. C. Wirtz, R. Pflugmacher

    Zielsetzung In dieser Kadaverstudie soll die Sicherheit der Anwendung eines Ablationssystems, welches spezifisch für die Ablation von spinalen Metastasen entwickelt wurde, ermittelt werden. Dabei wird der Fokus auf mögliche temperaturbedingte Schädigungen der benachbarten Gewebe gelegt. Material und Methoden Es wurde ein Tumormodell für 8 Lendenwirbel und 8 Brustwirbel des menschlichen Kadavers erzeugt. Die Ablation der simulierten Tumormasse wurde mit der spezifisch für Wirbelkörpermetastasen entwickelten SpineSTAR-Sonde (SpineSTAR, DFINE Inc., CA) durchgeführt. Während der Ablation wurden die Temperaturen des Wirbelkörpers, des Spinalkanals und des Neuroforamens gemessen. Diese wurden als Mittelwert und Standardabweichung dargestellt und mögliche Unterschiede zwischen der Anwendung der SpineSTAR-Sonde an Lendenwirbeln und Brustwirbeln mittels des Mann-Whitney-U-Tests ermittelt. Ergebnisse Bei durchgeführter Ablation der Lendenwirbel betrug die maximale Temperatur des unmittelbar an die Ablationszone angrenzenden Bereichs im Wirbelkörper 46,4 ± 3,3 °C, im Bereich des Neuroforamens 37,0 ± 0 °C und im Spinalkanal 37,3 ± 0,7 °C. In den Brustwirbeln erreichte die Temperatur im Wirbelkörper unmittelbar nahe der Ablationszone 44,4 ± 1,7 °C, im Neuroforamen 37,9 ± 1,7 °C und im Spinalkanal 37,25 ± 0,7 °C. Es zeigten sich keine signifikanten Temperaturunterschiede zwischen der durchgeführten Ablation in Lendenwirbeln und Brustwirbeln. Schlussfolgerung Die Ablation von spinalen Metastasen mittels der SpineSTAR-Sonde erwies sich im Kadavermodell als schonende Methode hinsichtlich möglicher Temperaturschädigungen des angrenzenden Gewebes. Purpose This clinical study investigates the use of a radiofrequency ablation system specifically developed for the ablation of spinal metastases. The investigation examines possible temperature-associated risks for the adjacent tissues. Material and Methods A tumour model was simulated for 8 lumbar and 8 thoracic vertebrae of a human cadaveric spine. The tumour mass was ablated with the SpineSTAR electrode (SpineSTAR, DFINE Inc., CA), which has been specifically developed for the ablation of spinal metastases. During the ablation procedure, the temperatures of the vertebra, the epidural space, and the neural foramen were measured with thermocouples. These temperatures were documented as means with standard deviations. Possible differences between lumbar and thoracic vertebrae were analysed with the Mann-Whitney U test. Results The maximal temperature of the lumbar vertebrae was 46.4 ± 3.3 °C near to the ablation zone, the temperature of the neural foramen was 37.0 ± 0 °C, and the temperature of the epidural space was 37.3 ± 0.7 °C. In the thoracic vertebrae, the temperature was 44.4 ± 1.7 °C near to the ablation zone, 7.9 ± 1.7 °C in the neural foramen, and 37.25 ± 0.7 °C in the epidural space. There was no significant difference in temperature distribution between treated lumbar and thoracic vertebrae. Conclusion Ablation of spinal metastases in a cadaveric model using the SpineSTAR electrode was shown to be a safe method with respect to possible temperature-related risks for the adjacent tissues. * Beide Autoren haben zu gleichen Teilen zum Entstehen der Arbeit beigetragen.

  • Klinische Studie zur Prüfung des iFuse Implant Systems® bei Patienten mit Iliosakralgelenksyndrom: 1-Jahres-Ergebnisse

    by R. Bornemann, R. Pflugmacher, M. Webler, E. M. W. Koch, J. Dengler, D. C. Wirtz, S. P. Frey

    Hintergrund: Es wird über eine Studie berichtet, welche der 1-jährigen postoperativen Kontrolle zur Wirksamkeit und Sicherheit des iFuse Implant Systems® bei Patienten mit Iliosakralgelenksyndrom (ISG-Syndrom) diente. Material und Methoden: Nach 6-monatiger unzureichender konservativer Behandlung wurden Patienten mit einwandfrei nachgewiesenem ISG-Syndrom für den Eingriff ausgewählt. Zum Einsatz kamen bei den minimalinvasiven Eingriffen iFuse-Implantate mit dreieckigem Profil und Beschichtung aus porösem Titanplasmaspray. Der Eingriff erfolgte unter Vollnarkose und fluoroskopischer Kontrolle. Es wurden jeweils 3 Implantate eingesetzt, die eine zueinander parallel angeordnete Verbindung des Kreuzbeins und Darmbeins bildeten. Ergebnisse: Es nahmen 24 Patienten (22 w; 92 %; 54,9 ± 14 Jahre) an der Studie teil. Die Operationen wurden in 11 Fällen (46 %) links und in 13 Fällen (54 %) rechts vorgenommen. Die durchschnittliche Operationszeit betrug 42,4 ± Minuten (95 %-KI: 35,6–49,3). Die Reduktion der Schmerzintensität betrug auf der VAS-Skala durchschnittlich 58 ± 11 mm (68 ± 7 %). Der Oswestry Score zeigte einen medianen Rückgang von 44 Prozentpunkten (57 %). Nach 12 Monaten gaben 15 Patienten (63 %) an, keine Schmerzmittel mehr einzunehmen. Schlussfolgerung: Die minimalinvasive Behandlung von Patienten mit ISG-Syndrom unter Verwendung des iFuse Implant Systems erweist sich über die Zeitdauer von 1 Jahr als sicher und signifikant schmerzlindernd; sie trägt auch entscheidend zur Verbesserung der Funktionsfähigkeit der Patienten bei. Background: This study reports one year post-operative monitoring of the efficacy and safety of iFuse Implant System® in patients with sacroiliac joint syndrome. Material and Methods: After 6 months of inadequate conservative treatment, patients with properly proven ISG syndrome were selected for surgery. The iFuse implants had a triangular profile and coating of porous titanium plasma spray and were used in the minimally invasive procedures. The procedure was performed under general anaesthesia and fluoroscopic control. In each case, three implants were placed. Results: 24 patients (22 f; 92 %; 54.9 ± 14 years) participated in the study. The operations were performed in 11 patients (46 %) on the left and in 13 patients (54 %) on the right. The mean operative time was 42.4 minutes (95 % CI: 35.6–49.3). The reduction in pain intensity on the VAS scale was 58 ± 11 mm (68 ± 7 %). The Oswestry score showed a median decrease of 44 percentage points (57 %). After 12 months, 15 patients (63 %) reported that they were taking no more painkillers. Conclusion: The minimally invasive treatment of patients with sacroiliac joint syndrome using the iFuse Implant System leads to significant analgesic effects over the period of one year; it also contributes significantly to improving the functioning of the patient.


  • Radiofrequency Ablation: Temperature Distribution in Adjacent Tissues

    by R. Bornemann, S. F. Grötz, P. H. Pennekamp, K. E. Wilhelm, K. Sander, D. C. Wirtz, R. Pflugmacher

    Purpose: This clinical study investigates the use of a radiofrequency ablation system specifically developed for the ablation of spinal metastases. The investigation examines possible temperature-associated risks for the adjacent tissues. Material and Methods: A tumour model was simulated for 8 lumbar and 8 thoracic vertebrae of a human cadaveric spine. The tumour mass was ablated with the SpineSTAR electrode (SpineSTAR, DFINE Inc., CA), which has been specifically developed for the ablation of spinal metastases. During the ablation procedure, the temperatures of the vertebra, the epidural space, and the neural foramen were measured with thermocouples. These temperatures were documented as means with standard deviations. Possible differences between lumbar and thoracic vertebrae were analysed with the Mann-Whitney U test. Results: The maximal temperature of the lumbar vertebrae was 46.4 ± 3.3 °C near to the ablation zone, the temperature of the neural foramen was 37.0 ± 0 °C, and the temperature of the epidural space was 37.3 ± 0.7 °C. In the thoracic vertebrae, the temperature was 44.4 ± 1.7 °C near to the ablation zone, 7.9 ± 1.7 °C in the neural foramen, and 37.25 ± 0.7 °C in the epidural space. There was no significant difference in temperature distribution between treated lumbar and thoracic vertebrae. Conclusion: Ablation of spinal metastases in a cadaveric model using the SpineSTAR electrode was shown to be a safe method with respect to possible temperature-related risks for the adjacent tissues. Zielsetzung: In dieser Kadaverstudie soll die Sicherheit der Anwendung eines Ablationssystems, welches spezifisch für die Ablation von spinalen Metastasen entwickelt wurde, ermittelt werden. Dabei wird der Fokus auf mögliche temperaturbedingte Schädigungen der benachbarten Gewebe gelegt. Material und Methoden: Es wurde ein Tumormodell für 8 Lendenwirbel und 8 Brustwirbel des menschlichen Kadavers erzeugt. Die Ablation der simulierten Tumormasse wurde mit der spezifisch für Wirbelkörpermetastasen entwickelten SpineSTAR-Sonde (SpineSTAR, DFINE Inc., CA) durchgeführt. Während der Ablation wurden die Temperaturen des Wirbelkörpers, des Spinalkanals und des Neuroforamens gemessen. Diese wurden als Mittelwert und Standardabweichung dargestellt und mögliche Unterschiede zwischen der Anwendung der SpineSTAR-Sonde an Lendenwirbeln und Brustwirbeln mittels des Mann-Whitney-U-Tests ermittelt. Ergebnisse: Bei durchgeführter Ablation der Lendenwirbel betrug die maximale Temperatur des unmittelbar an die Ablationszone angrenzenden Bereichs im Wirbelkörper 46,4 ± 3,3 °C, im Bereich des Neuroforamens 37,0 ± 0 °C und im Spinalkanal 37,3 ± 0,7 °C. In den Brustwirbeln erreichte die Temperatur im Wirbelkörper unmittelbar nahe der Ablationszone 44,4 ± 1,7 °C, im Neuroforamen 37,9 ± 1,7 °C und im Spinalkanal 37,25 ± 0,7 °C. Es zeigten sich keine signifikanten Temperaturunterschiede zwischen der durchgeführten Ablation in Lendenwirbeln und Brustwirbeln. Schlussfolgerung: Die Ablation von spinalen Metastasen mittels der SpineSTAR-Sonde erwies sich im Kadavermodell als schonende Methode hinsichtlich möglicher Temperaturschädigungen des angrenzenden Gewebes. * Both authors contributed equally to this work.


  • Klinische Aspekte zur Problematik der Wirbelkörpermetastasen, Möglichkeiten moderner Behandlungsmethoden unter besonderer Berücksichtigung der Radiofrequenzablation

    by R. Bornemann, T. Jansen, M. Wollny, D. Wirtz, R. Pflugmacher

    From 100,000 people in Germany, statistically calculated, 441 males and 350 females suffer from a cancer disease. In about 50 to 80 % of patients with breast or prostate carcinoma bone metastases are registered, which is connected, among others, with a high risk for pathological fractures and other debilitating diseases. The diagnosis of bone metastases is done by conventional X-ray equipment, CT, MRI, and especially with the help of skeletal scintigraphy. For therapy bisphosphonates, anti-hormones and chemotherapeutic agents as drugs are used. Furthermore, radiotherapy, radionuclides, surgery and ablative procedures are applied. A more recent technical method is the STAR™ Tumour Ablation System (RFA), by which minimally invasively an electrode is introduced into the vertebral bodies. The system ensures precise control and thus a targeted ablation of the metastases. Several publications and reports describing a combined application demonstrate the synergistic effectiveness of RFA and radiofrequency kyphoplasty.


  • Radiofrequenzkyphoplastie in Kombination mit posteriorer Fixierung zur Behandlung von Wirbelsäulenfrakturen

    by T. Jansen, R. Bornemann, L. A. Otten, K. Kabir, D. Wirtz, K. Sander, R. Pflugmacher

    Zielsetzung: Im Rahmen der prospektiven Studie soll ein Nachweis der Wirksamkeit und Sicherheit der Radiofrequenzkyphoplastie in Kombination mit zusätzlicher posteriorer Fixierung anhand einer statistischen Auswertung von Behandlungsdaten erbracht werden. Material und Methoden: Es wurden 19 Patienten (Alter: 74,5 ± 7,2 Jahre) mit osteoporotischen Wirbelkörperfrakturen in die Studie eingeschlossen, die aufgrund einer ausgeprägten Fehlstellung eine operative Korrektur der Fraktur benötigten. Bei allen Patienten wurde eine Augmentation mittels Radiofrequenzkyphoplastie vorgenommen, verbunden mit einer posterioren Fixierung durch zementaugmentierbare Schrauben. Zur Bewertung der Wirksamkeit und Sicherheit wurden die Schmerzintensität mittels der visuellen Analogskala (VAS) und die Beeinträchtigung der Lebensqualität durch den Oswestry Disability Index (ODI) ermittelt. Zudem erfolgte eine radiologische Auswertung der anterioren und medialen Wirbelkörperhöhe und des Kyphosewinkels sowie die Erhebung von aufgetretenen Zementextrusionen. Alle Daten wurden zu den Zeitpunkten präoperativ, 3–4 Tage postoperativ, 3 Monate und 6 Monate postoperativ erhoben. Resultate: Durch die Behandlung konnten unmittelbar postoperativ signifikante Verbesserungen des mittleren VAS und ODI erzielt werden (pVAS < 0,001, pODI < 0,001). Der postoperative Verlauf zeigte von jedem Untersuchungstermin zum folgenden eine weitere Verbesserung des VAS und ODI (pVAS_post–3 M < 0,001, pVAS_3 M–6 M = 0,17, pODI_post–3 M < 0,001, pODI_3 M–6 M = 0,004). Bezüglich der Wirbelkörperhöhe des augmentierten Wirbels konnte postoperativ eine signifikante Aufrichtung des Wirbelkörpers erreicht werden (p_anterior < 0,001, p_medial < 0,001), die jedoch im folgenden postoperativen Verlauf wieder leicht absank. Der Kyphosewinkel konnte ebenfalls durch den Eingriff signifikant reduziert werden (p < 0,001), wobei dieser im folgenden Verlauf wieder zunahm (p_post–3 M = 0,023, p_3 M–6 M = 0,016), jedoch immer noch deutlich geringer ausgeprägt war als präoperativ. Bei 3 Patienten (15,79 %) kam es während des Eingriffs zu Zementextrusionen. Schlussfolgerung: Die Radiofrequenzkyphoplastie erwies sich in Verbindung mit posteriorer Fixierung als eine wirksame und sichere Therapie für Wirbelkörperfrakturen mit vergleichbaren Anteilen von Zementextrusionen zur Ballonkyphoplastie. Purpose: Radiofrequency kyphoplasty is an advancement of the balloon kyphoplasty and offers comparable results with a shorter operation time and a lower risk of cement leakage. This prospective study investigates the outcome of radiofrequency kyphoplasty in combination with posterior fixation by a cement-augmented screw system. Accordingly, statistical analyses of the treatment data were performed. Materials and Methods: 19 patients (mean age: 74.5 ± 7.2 years) with osteoporotic vertebral burst fractures were included in the study. All of them required a surgical intervention for treating the fracture. Thereby, the vertebrae were augmented by radiofrequency kyphoplasty and a posterior fixation by cement-augmentable screws was performed. To evaluate the effectiveness and safety of the procedure, pain was measured with the visual analog scale (VAS) and functional impairment was analysed by measuring the Oswestry disability index (ODI). Furthermore, a radiographic analysis of the anterior and medial height of the vertebrae and the degree of kyphosis were undertaken. All data were recorded preoperatively, 3 to 4 days postoperatively, 3 months postoperatively and 6 months postoperatively and any additionally occurring cement leakage was documented. Results: The treatment showed a significant reduction of pain and improvement of the functional impairment at the 3 to 4 days postoperative evaluation (pVAS < 0.001, pODI < 0.001). The further follow-ups demonstrated an ongoing improvement of the VAS and ODI from each measurement to the next (pVAS_post–3 M < 0.001, pVAS_3 M–6 M = 0.17, pODI_post–3 M < 0.001, pODI_3 M–6 M = 0.004). The height of the vertebrae was significantly improved after the surgery (p_anterior < 0.001, p_medial < 0.001) and reduced slightly from follow-up to follow-up, but still remained higher than the preoperative value. The degree of kyphosis was also significantly improved after the surgery (p < 0.001), whereby a significant deterioration was shown at the following examinations (p_post-3 M = 0.023, p_3 M–6 M = 0.016). But even as the height decreased the degree of kyphosis was still improved in relation to the preoperative values. During the surgery cement leakage occurred in 3 cases (15.79 %). Conclusion: Radiofrequency kyphoplasty is a safe and effective procedure for the treatment of vertebral compression fractures in combination with the use of posterior fixation by cement-augmentable screws with an acceptable rate of cement leakage.


  • Radiofrequenz-Kyphoplastie – ein innovatives Verfahren zur Behandlung von vertebralen Kompressionsfrakturen – Vergleiche mit konservativer Behandlung

    by R. Bornemann, K. Kabir, L. A. Otten, M. Deml, E. M. W. Koch, D. C. Wirtz, R. Pflugmacher

    Zielsetzung: Im Rahmen einer Auswertung von Behandlungsprotokollen sollte die Dokumentation zu Wirksamkeit und Sicherheit der Radiofrequenz-Kyphoplastie erweitert und ein Vergleich zur konservativen Behandlung vorgenommen werden. Patienten, Material und Methoden: Es wurden Patienten mit schmerzhafter osteoporotischer Wirbelkörperfraktur entsprechend den Befunden im Alltag einer orthopädischen Universitätsklinik in die Vergleichsstudie aufgenommen, bei denen die Indikation für einen operativen Eingriff gemäß den DVO-Richtlinien interdisziplinär bestätigt wurde. Für die Vergleichsgruppe wurden diejenigen Patienten mit den gleichen klinischen und radiologischen Befunden rekrutiert, die sich aber gegen eine Operation aussprachen. Für die Operationen wurde das StabiliT® Vertebral Augmentation System zur Durchführung der Radiofrequenz-Kyphoplastie der Firma DFine, Inc. (San Jose, CA, USA) verwendet. Die Zementinjektion erfolgte mit einem „Multiplex-Controller“. Die Resultate des neuen Verfahrens wurden denen einer Vergleichsgruppe gegenübergestellt, die rein konservativ behandelt wurde. Ergebnisse: In der Radiofrequenz-Kyphoplastie-Gruppe (n = 114) beobachteten wir einen durchschnittlichen Rückgang der VAS-Werte um fast 60 mm, welcher sich im Verlauf der Nachbeobachtung noch steigerte. Ebenso zeigten sich ausgeprägte Besserungen des Oswestry-Scores (46 % Punkte) nach 6 Wochen. Die durchschnittliche Zunahme der Wirbelköperhöhe betrug 2,8 mm nach dem Eingriff. In der konservativ behandelten Gruppe ergaben sich während der 6-wöchigen Beobachtungszeit nur sehr geringe Veränderungen im Vergleich zu den Ausgangsbefunden. Dementsprechend entschieden sich 33 von 67 Patienten nach 6 Wochen zum operativen Eingriff, der zu deutlichen Verbesserungen (VAS, Oswestry, Wirbelköperhöhe) führte. Hervorzuheben ist die geringe Rate an Zementaustritten in der Radiofrequenz-Kyphoplastie-Gruppe von 6 % (n = 7). Schlussfolgerungen: Die Radiofrequenz-Kyphoplastie bietet hinsichtlich klinischer Wirksamkeit eine gesicherte Überlegenheit gegenüber einer konservativen Therapie. Hinzu kommt, dass die impaktierten Wirbelköper gezielter aufgerichtet werden können, der Zement bei Bedarf eine sehr lange Verarbeitungszeit erlaubt, eine räumliche Verzahnung des Zements mit dem Knochen erreicht wird, wenig Zement austritt, eine geringere Strahlenbelastung des Operateurs besteht und die Operationszeit verkürzt wird. Objective: An evaluation of treatment protocols was used to expand the documentation of efficacy and safety of radiofrequency kyphoplasty (RFK). Additionally, a comparison of this new and innovative procedure with conservative treatment was carried out. Patients, Materials and Methods: Patients with painful osteoporotic vertebral fractures according to the common findings in an orthopaedic university hospital were included in the comparison study in which the indication for surgical intervention action according to the DVO guidelines was interdisciplinary confirmed. For the comparison group, patients with the same clinical and radiological findings were recruited who rejected a surgical intervention. For surgery, the StabiliT® Vertebral Augmentation System for a radiofrequency kyphoplasty by the company DFine was used. The cement was injected with a “multiplex controller”. Thus, the results of the new method were compared to those of a group that was treated conservatively. Results: The radiofrequency kyphoplasty (n = 114) resulted in an average decrease of VAS scores by almost 60 mm, which increased during the follow-up. Similarly, the Oswestry scores showed a marked improvement by 46 % points after 6 weeks. The mean increase in vertebral body height was 2.8 mm after radiofrequency kyphoplasty. In the conservatively treated group only very small changes compared to the initial findings were registered during the 6-week observation period. Accordingly, 33 of 67 patients decided after 6 weeks for surgery, which led to corresponding improvements (VAS, Oswestry, vertebral body height). Noteworthy is the low rate of cement leakage in the radiofrequency kyphoplasty group of 6 % (n = 7). Conclusions: Radiofrequency kyphoplasty offers a secure superiority over conservative treatment regarding clinical efficacy. In addition, the fractured vertebrae can be better targeted and erected, a longer processing time of the cement is ensured, a high interdigitation of the cement with the bone is guaranteed, the rate of cement leakage is low, the risk of radiation for the surgeon is minimised, and the operation time is shortened.


  • Open Access

    Generation of Wear Debris and Inflammatory Reaction around Cervical Disk Prosthesis after a Minimum of 18 Months In Vivo

    by K. Kabir, M. Deml, R. Pflugmacher, D. C. Wirtz

    Cervical disk replacement seems to be a promising alternative to anterior cervical fusion. However, there is still lack of information about the generation of wear particles and local reaction to these particles in human cervical spine under in vivo conditions. The authors report clinical outcome and histological findings of three revised cervical prosthesis after a minimum of 18 months in function. We report three patients who underwent revision of their cervical disk prosthesis after a minimum of 18 months in vivo. All patients were asymptomatic for a minimum of 6 months after initial procedure. Cervicobrachialgia was the most common presentation. Pain was measured using the self-reporting Visual Analogue pain Scale (VAS). The preoperative diagnostic algorithm consists of functional X-ray, cervical MRI, myelographie, postmyelo-CT, 3-phase bone scintigraphy, and SPECT-CT. All implants were retrieved and the surrounded soft tissue was histological evaluated. All patients were fused in the affected segment. The preoperative VAS-Score was 7, 3 + /−1. All implants were retrieved without any complications. All the prostheses were surrounded by a soft fibrotic tissue. Metal and PE debris with signs of foreign body inflammatory reaction was found within the surrounding soft tissue shell of the segment. The soft tissue toward epidural space caused narrowing of epidural space. Only one patient had a loosening of one endplate, which was visible in the preoperative scintigraphy. Two patients were pain free and one patient had minor neck pain (VAS 3) without radicular pain after the revision surgery. Despite the limits of our case series, the results show that generation of wear debris and inflammatory reaction to these particles exist after cervical disk replacement. Revision surgery is promising in such patients after a standardized diagnostic algorithm. One goal of the next generation of cervical disk replacement should be low generation of wear particles and less biological active wear particles. I confirm having declared any potential conflict of interest for all authors listed on this abstract No Disclosure of Interest None declared

  • Patients with osteoporotic compression fractures: Balloon kyphoplasty vs RF-Kyphoplasty

    by R. Pflugmacher⁎, R. Bornemann, M. Deml, K. Kabir, D.C. Wirtz

  • Vergleichende Befunderhebungen der Ballonkyphoplastie bei Patienten mit Wirbelkörperfrakturen infolge von Osteoporose, Metastasen und Myelomen

    by R. Pflugmacher, R. Bornemann, E. Koch, D. Hausmann, L. Otten, H. Goost, D. Wirtz, K. Kabir

    Zielsetzung: Durch Auswertungen von Behandlungsprotokollen sollte die Dokumentation zu Wirksamkeit, Wirkdauer und Sicherheit der Ballonkyphoplastie erweitert werden. Darüber hinaus sollten die Auswertungen der Klärung dienen, welche Unterschiede bei der Ballonkyphoplastie von Patienten mit Wirbelkörperfrakturen hinsichtlich Wirksamkeit und Sicherheit in Abhängigkeit von den Grunderkrankungen Osteoporose, Knochenmetastasen und Myelomen bestehen. Material und Methoden: Im Verlauf der Operation wurde nach Platzierung der Arbeitskanäle der jeweilige Ballon eingebracht, um die Endplatten der Wirbelkörper zu reponieren. Nach Entfernung des Ballons wurden die entstandenen Kavernen mit PMMA aufgefüllt. Die radiologischen und klinischen Nachuntersuchungen wurden zu festgelegten Zeitpunkten über eine Dauer von bis zu 3 Jahren vorgenommen. Zur Auswertung wurden die klinischen und die bildgebenden Befunde vor der Behandlung und zu festgelegten Zeitpunkten in Tabellen übertragen und statistisch ausgewertet. Resultate: Die Gegenüberstellungen der postoperativen Befunde entsprechend der Ausgangsdiagnose (Metastasen: n = 222, Osteoporose: n = 122, Myelome: n = 122) belegten deutliche Unterschiede bzgl. des Zementaustritts (14 %, 5 %, 7,5 %), der jedoch in allen Fällen mit keinen klinischen Folgen verbunden war. Die kleinen Differenzen hinsichtlich des Rückgangs der Schmerzintensität (VAS > 50 mm in allen Gruppen) nach der Operation und bis zu 12 Monate waren ohne klinische Bedeutung. Auch beim Oswestry-Score wurden keine Unterschiede zwischen den 3 Gruppen registriert. Bei den Osteoporosepatienten konnte infolge der schlechteren Ausgangslage durch die Kyphoplastie eine deutlichere Anhebung der Wirbelkörperhöhe erreicht werden als bei den Vergleichsgruppen (∅ 3,1 mm vs. 0,4–0,5 mm; p < 0,001). Entsprechend verminderte sich der Kyphosewinkel in der Osteoporosegruppe auch stärker als in den Vergleichsgruppen. Schlussfolgerungen: Grundsätzlich zeigte sich bei der überwiegenden Zahl der Fälle eine unmittelbar postoperativ einsetzende Schmerzlinderung und eine deutliche Verbesserung der Funktionsfähigkeit, die – soweit sie kontrolliert werden konnten – über einen Zeitraum von bis zu 3 Jahren anhielten. Die vergleichenden Gegenüberstellungen haben zu dem Resultat geführt, dass die Ballonkyphoplastie sowohl bei Patienten mit Wirbelkörperfrakturen in der Folge einer Osteoporose als auch im Zusammenhang mit Knochenmetastasen oder Myelomen unterschiedslos erfolgreich angewendet werden kann. Objective: By evaluations of treatment protocols, the documentation of balloon kyphoplasty regarding efficacy, duration of action and safety should be expanded. In addition, the evaluations should help to clarify the differences in balloon kyphoplasty for patients with vertebral fractures concerning efficacy and safety in relation to the underlying diseases: osteoporosis, bone metastases or myeloma. Material and Methods: In order to reposition the endplates of the vertebrae a balloon was inserted after placement of the working channels. After removal of the balloon, the resulting caverns were filled with PMMA. The radiological and clinical follow-up examinations were carried out over a period of up to 3 years. The clinical and radiological findings before and after treatment at specified visits were transferred to a statistical programme and evaluated. Results: The comparisons of the postoperative results according to the initial diagnosis (metastases: n = 222, osteoporosis: n = 122, myeloma: n = 122) demonstrated significant differences with respect to the cement leakage (14 %, 5 %, 7.5 %), but in all cases without any clinical relevance. The small differences related to the reduction in pain intensity (VAS > 50 mm in each group) after surgery were up to 12 months with no clinical significance. Also in the Oswestry score no differences between the 3 groups were registered. In the case of osteoporosis patients, due to the lower starting position a more significant increase of vertebral body height could be achieved by the kyphoplasty than in the comparison groups of patients with metastases or myeloma (∅ 3.1 mm vs. 0.4–0.5 mm; P < 0.001). Consequently, the kyphosis angle decreased in the osteoporotic group also more strongly than in the comparison groups. Conclusions: It is evident that the pain relief in the vast majority of cases started immediately after surgery. Additionally, a significant improvement in functioning (Oswestry score) was registered. Both clinical parameters – as far as they could be checked – showed a steady degree of improvement over a period of at least 3 years. This comparative analysis led to the conclusion that balloon kyphoplasty can be successfully applied indiscriminately in patients with vertebral fractures as a result of osteoporosis and also to fractures associated with bone metastases or with myeloma.