DODror Ovadia

Dror Ovadia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dror Ovadia has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Shlomo Wientroub

    Department of Pediatric Orthopaedic Surgery, Dana Children's Hospital, Tel Aviv Sourasky Medical Center, 6 Weizman St., 64239, Tel Aviv Israel

    6 shared publications
  • Eitan Segev

    Department of Pediatric Orthopedics, Dana Children's Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel

    2 shared publications
  • Michael Fishkin

    Department of Pediatric Orthopaedics, Dana Children's Hospital, Tel Aviv Sourasky Medical Center, Israel

    2 shared publications
  • Moshe Yaniv

    2 shared publications
  • Shlomo Hayek

    Department of Paediatric Orthopaedic Surgery, Dana Children's Hospital, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, 6 Weizman Street, 64239, Tel Aviv Israel

    2 shared publications
  • Shlomo Wientroub

    Department of Paediatric Orthopaedic Surgery, Dana Children's Hospital, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, 6 Weizman Street, 64239, Tel Aviv Israel

    2 shared publications

Latest Publications

  • Open Access

    Measuring Dynamic Leg Length during Normal Gait

    by Sam Khamis, Shmuel Springer, Dror Ovadia, Sima Krimus, Eli Carmeli

    Dynamic leg length [DLL] is a resultant factor of anatomic leg length and lower limb movement that is measured by the distance from the hip to the heel, ankle, and forefoot during the gait cycle. The aim of this study was to present DLL measurement during normal gait. Forty healthy participants underwent a gait evaluation using a motion analysis system. The average DLLs were compared between sides during the gait cycle using the paired t-test at 51 sample points. Time of maximal and minimal DLLs and the ratio between maximal and minimal DLLs during the gait cycle were calculated. DLLs were found to be consistent, indicated by a within standard deviation of 0.103]. DLL patterns and time of maximal and minimal DLLs were established. The ratio between maximal DLLs during the stance phase and minimal DLLs during the swing phase was also defined and found to be symmetrical. Normative data of DLL measures were set with respect to magnitude and pattern during the gait cycle. These data might serve as a reference for abnormal gait deviation reflected by abnormal DLLs, thus promoting a new perspective in gait analysis.


  • Open Access

    Classification of adolescent idiopathic scoliosis (AIS)

    by Dror Ovadia

    In 1983 Howard King presented his classification system for adolescent idiopathic scoliosis (AIS) based on the experience with Harrington rod instrumentation. Curves were divided into five types and guidelines and recommendations for which levels should be instrumented were given to preserve motion as much as possible. As segmental instrumentation systems began to gain favor over the Harrington rods this system failed and led to the development of a new classification system which was presented by Lawrence Lenke in 2001. In order to define a curve type by the Lenke classification, one must identify the curve type, the lumbar modifier and, for the first time in any classification system for scoliosis, the sagittal profile was also included. The Lenke classification showed higher inter and intra-reliability compared to the King classification. It also provided a better and more reliable tool to assist surgeons in choosing the best method of treatment for each curve pattern. Although the Lenke classification is more comprehensive and reliable than the King classification it is still far from perfect. It does not address the rotational component of the deformity. New technologies which provide three-dimensional (3D) reconstruction of the spine may serve as a basis for a truly 3D classification of scoliosis and for new therapeutic concepts.


  • Open Access

    Factors associated with the success of the Rigo System Chêneau brace in treating mild to moderate adolescent idiopathic scoliosis

    by Dror Ovadia, Sharon Eylon, Avraham Mashiah, Shlomo Wientroub, Eduard David Lebel

    Background: Adolescent idiopathic scoliosis (AIS) is the most prevalent spine deformity within the pediatric population. Orthosis is the mainstay of conservative treatment for mild to moderate AIS. The Rigo System Chêneau (RSC) brace is a custom-made thoracolumbar sacral orthosis (TLSO) based on a three-dimensional correction concept. The purpose of this study was to identify factors that could predict the therapeutic success/failure of the RSC brace. Materials and methods: A retrospective cohort study was performed on all consecutive patients according to the Scoliosis Research Society (SRS) criteria for the success of conservative treatment. Participants had a 2-year follow-up beyond the termination of brace treatment. All patients were treated with the RSC orthotic device. Results: Ninety-three patients met the inclusion criteria. At treatment onset, their average age was 12.9 years, average Cobb angle 31.97°, Risser score 1.07, and the mean angle of thoracic rotation (ATR) was 10.2°. The mean brace treatment period was 36 months. Treatment was successful in 83.8 % of these patients ( n = 79). The average final Cobb angle was 28.97°, Risser score 4.88, and ATR 8.09°. The pre-treatment factors associated with the success of applying the RSC brace were a high Risser score [odds ratio (OR) = 2.97, 95 % confidence interval [CI] 1.18–7.44; p = 0.02), a low Cobb angle (OR = 0.92, 95 % CI 0.85–0.99; p = 0.02), and low ATR (OR = 0.86, 95 % CI 0.75–0.99; p = 0.04). Conclusions: The treatment of mild to moderate AIS with the RSC brace provides excellent clinical results. Its added benefit is enabling a three-dimensional correction of a three-dimensional deformity. Pre-treatment high Risser score, low Cobb angles, and low ATRs are associated with treatment success. Level of evidence: Retrospective analysis, Level III.


  • The Contribution of an Electronic Conductivity Device to the Safety of Pedicle Screw Insertion in Scoliosis Surgery

    by Dror Ovadia, Akiva M.Med.Sc D-Abnm Korn, Michael Fishkin, David M. Steinberg, Shlomo Wientroub, Elisha Ofiram

    Study Design. Retrospective, controlled clinical study. Objective. To evaluate the contribution of an electronic conductivity device (ECD) to the safety of pedicle screw insertion in pediatric scoliosis surgery. Summary of Background Data. The implantation of pedicle screws in spinal deformity correction surgery has evolved into the currently predominant fixation technique. Methodologies for optimizing placement of pedicle screws are fluoroscopy, electromyography, and intraoperative image-based navigation. A hand-held ECD was recently introduced. Methods. Pedicle screw insertion was analyzed in 248 pediatric scoliosis patients (idiopathic, congenital, neuromuscular, syndromatic). Group I included 150 procedures without the aid of the ECD and group II included 98 ECD-aided procedures. The two groups were matched by age, sex, etiology, Cobb angle, and surgical criteria. Data on screw position and concomitant neuromonitoring alarms were compared. Group I consisted of patients operated with both the hybrid construct and pedicle screw instrumentation, while group II consisted of patients operated solely with pedicle screws. Both groups were operated on by a single surgeon with the same neurophysiologic methodology. Clinically relevant misplaced pedicle screws were established by intraoperative monitoring alarms concomitant with pedicle screw insertion. Results. A total of 1270 pedicle screw placements were analyzed in group I and compared with 1400 pedicle screw placements in group II. Neuromonitoring alarms concomitant with screw placement occurred in 10 procedures in group I (6.6%) compared with 3 in group II (3.0%). The contribution of the electronic device to reducing the number of neurophysiologic alarms was significant (P = 0.048, Fisher exact test). Nine of the 13 monitoring alarms (69%) were associated with implantation adjacent to the apex of the spinal curve. Conclusion. The use of an ECD significantly reduced the incidence of clinically relevant misplaced screws in a variety of scoliosis patients, thereby increasing the safety of pedicle screw implantation.


  • Open Access

    The influence of brace type on the success rate of the Ponseti treatment protocol for idiopathic clubfoot

    by Yoram Hemo, Eitan Segev, Ariella Yavor, Dror Ovadia, Shlomo Wientroub, Shlomo Hayek

    Purpose: The success of the Ponseti method for treating idiopathic clubfoot deformity is dependent on the casting techniques and the adherence of the patient to the foot abduction brace protocol. Newly developed brace designs claim to be more comfortable, to be easier to use and to prevent dislodgement of the foot from the brace, making them more efficient and improving patient compliance. They are, however, more costly, and, therefore, accessible to fewer patients. We compared the compliance and treatment outcome using two brace designs, the traditional simple brace of pre-walking shoes attached to a Dennis Browne (DB) bar and the new sophisticated Mitchell brace. Methods: We compared the functional outcome and compliance with the post-corrective bracing protocol of 38 children with idiopathic clubfoot treated in our institution using two brace designs. Twenty-one chose the DB brace and 17 chose the Mitchell brace. Results: There was no difference in the compliance rate or in the final clinical and radiological outcomes of the two groups after a minimum of 2 years of follow-up. A positive correlation was found between the Pirani score at the beginning of treatment and the final functional score for both groups. Both groups were satisfied with the selected brace. Both groups were equally compliant with the brace protocol. Conclusion: We conclude that new and more expensive brace designs do not necessarily provide better clinical results. Fully corrected foot and a strong family–treating team partnership are crucial to adherence with the brace protocol.


  • Open Access

    A new pelvic rod system for the surgical correction and fixation of pelvic obliquity in pediatric neuromuscular scoliosis

    by Ofir Chechik, Michael Fishkin, Shlomo Wientroub, Dror Ovadia

    Purpose: To describe surgical outcomes using the new device in pediatric neuromuscular scoliosis. Methods: All patients with neuromuscular disorders requiring surgery with pelvic fixation for the correction of scoliosis in the period 2002–2009 were operated by the new pelvic rod fixation device. Coronal and sagittal alignment before and after surgery until the latest follow-up were evaluated by standard X-rays. Intraoperative and postoperative complications were recorded. Results: All 18 study patients (mean age at surgery 15 years, range 10–27) achieved solid fusion at a mean follow-up of 41 months. The coronal Cobb angle improved from 82° ± 31° (range 36–168) to 33° ± 25° at the last follow-up (range 9–95 months) ( P < 0.0001). Pelvic obliquity improved from 19° ± 6° (range 10–30) to 5° ± 5° (range 0–14) ( P < 0.0001). Early complications included pneumonia, urinary tract infection, disseminated intravascular coagulation (DIC), and hypovolemic shock. Three patients required debriding and received prolonged antimicrobial therapy for deep wound infection (none required implant removal). At the latest follow-up, no patient complained of lumbar pain or worsening of ambulatory status or level of activity. Conclusion: Surgery employing the new pelvic rod fixation device allowed solid fusion and fixation with significant correction of multiplanar deformity, but the complication rate was high.


  • Open Access

    Intra- and interobserver reliability analysis of digital radiographic measurements for pediatric orthopedic parameters using a novel PACS integrated computer software program

    by Eitan Segev, Yoram Hemo, Shlomo Wientroub, Dror Ovadia, Michael Fishkin, David M. Steinberg, Shlomo Hayek

    Background: The between-observer reliability of repeated anatomic assessments in pediatric orthopedics relies on the precise definition of bony landmarks for measuring angles, indexes, and lengths of joints, limbs, and spine. We have analyzed intra- and interobserver reliability with a new digital measurement system (TraumaCad Wizard™). Methods: Five pediatric orthopedic surgeons measured 50 digital radiographs on three separate days using the TraumaCad system. There were 10 anterior–posterior (AP) pelvic views from developmental dysplasia of the hip (DDH) patients, 10 AP pelvic views from cerebral palsy (CP) patients, 10 AP standing view of the lower limb radiographs from leg length discrepancy (LLD) patients, and 10 AP and 10 lateral spine X-rays from scoliosis patients. All standing view of the lower limb radiographs were calibrated by the software to allow for accurate length measurements, using as reference a 1-inch metal ball placed at the level of the bone. Each observer performed 540 measurements (totaling 2,700). We estimated intra- and interobserver standard deviations for measurements in all categories by specialists and nonspecialists. The intraclass correlation coefficient (ICC) summarized the overall accuracy and precision of the measurement process relative to subject variation. We examined whether the relative accuracy of a measurement is adversely affected by the number of bony landmarks required for making the measurement. Results: The overall ICC was >0.74 for 13 out of 18 measurements. Accuracy of the acetabular index for DDH was greater than for CP and relatively low for the center–edge angle in CP. Accuracy for bone length was better than for joint angulations in LLD and for the Cobb angle in AP views compared to lateral views for scoliosis. There were no clinically important biases, and most of the differences between specialists and nonspecialists were nonsignificant. The correlation between the results according to the number of bony landmarks that needed to be identified was also nonsignificant. Conclusions: Digital measurements with the TraumaCad system are reliable in terms of intra- and interobserver variability, making it a useful method for the analysis of pathology on radiographs in pediatric orthopedics.


  • Primary pyomyositis in children: a retrospective analysis of 11 cases

    by Dror Ovadia, Eli Ezra, Liat Ben-Sira, Ada Kessler, Jacob Bickels, David Keret, Moshe Yaniv, Shlomo Wientroub, Franklin Lokiec

    This study was undertaken to review our approach to diagnosis and treatment in a series of 11 patients (mean age 8.2 years) with primary pyomyositis, who had neither an underlying disease nor a compromised immune system. Nine of the children had positive blood cultures, Staphylococcus aureus (eight) and Streptococcus group A (one). The sites of infection were iliopsoas (four), obturator (two), hip adductors (two), levator scapula (one), thoracolumbar paraspinal (one) and gastrocnemius (one) muscles. Antibiotic treatment was initially intravenous, followed by oral administration. Of five patients with evidence of abscess formation, three underwent percutaneous drainage, whereas two required open surgical drainage. The infection resolved completely without any sequela in 10 children. One patient who developed acute compartment syndrome showed late signs of osteonecrosis of the tibial shaft segment.