Giampiero Campanelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Giampiero Campanelli has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Marta Cavalli
Galeazzi-Sant’Ambrogio Hospital, University of Insubria, 20157 Milan, Italy
4 shared publications D. Pettinari
Department of Surgical Sciences, Policlinico Hospital I.R.C.C.S., University of Milano, Milano, Italy
3 shared publicationsE. Contessini Avesani
Department of Surgical Sciences, Policlinico Hospital I.R.C.C.S., University of Milano, Milano, Italy
3 shared publicationsDiego Pettinari
Department of Surgical Sciences, University of Milano, Policlinico Hospital I.R.C.C.S, Pad. Beretta Est, Milano, Italy
2 shared publicationsEttoreContessini Avesani
Department of Surgical Sciences, University of Milano, Policlinico Hospital I.R.C.C.S, Pad. Beretta Est, Milano, Italy
2 shared publicationsF. M. Nicolosi
Department of Surgical Sciences, Policlinico Hospital I.R.C.C.S., University of Milano, Milano, Italy
2 shared publications
Latest Publications
- 8 September 2017
- Published by Springer Nature in Hernia
- Vol. 21 (6) , 963-971
Humanitarianism in surgery
- 8 September 2017
- Published by Springer Nature in Hernia
- Vol. 21 (6) , 963-971
Humanitarianism in surgery
- 11 January 2006
- Published by Springer Nature in Hernia
- Vol. 10 (2) , 159-161
Inguinal hernia recurrence: classification and approach
We reviewed case reports, updated to January 2005, of 2,468 operations for groin hernia in 2,350 patients, including 277 recurrent hernias. The data obtained, following a simple anatomo-clinical classification into three types that could be used to orient surgical strategy, were: type R1—first recurrence of “high” oblique external reducible hernia with small (<2 cm) defect in non-obese patients after pure tissue or mesh repair; type R2—first recurrence of “low” direct reducible hernia with small (<2 cm) defect in non-obese patients after pure tissue or mesh repair; and type R3—all other recurrences, including femoral recurrences, recurrent groin hernia with large defect (inguinal eventration), multi-recurrent hernias, non-reducible contralateral primary or recurrent hernia, and situations compromised by aggravating factors (e.g. obesity) or otherwise not easily included in R1 or R2 after pure tissue or mesh repair.
- 11 January 2006
- Published by Springer Nature in Hernia
- Vol. 10 (2) , 159-161
Inguinal hernia recurrence: classification and approach
We reviewed case reports, updated to January 2005, of 2,468 operations for groin hernia in 2,350 patients, including 277 recurrent hernias. The data obtained, following a simple anatomo-clinical classification into three types that could be used to orient surgical strategy, were: type R1—first recurrence of “high” oblique external reducible hernia with small (<2 cm) defect in non-obese patients after pure tissue or mesh repair; type R2—first recurrence of “low” direct reducible hernia with small (<2 cm) defect in non-obese patients after pure tissue or mesh repair; and type R3—all other recurrences, including femoral recurrences, recurrent groin hernia with large defect (inguinal eventration), multi-recurrent hernias, non-reducible contralateral primary or recurrent hernia, and situations compromised by aggravating factors (e.g. obesity) or otherwise not easily included in R1 or R2 after pure tissue or mesh repair.
- Open Access
- 1 January 2006
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 2 (3) , 147-50
Inguinal hernia recurrence: Classification and approach
Journal of Minimal Access Surgery (JMAS), the official publication of Indian Association of Gastrointestinal Endo Surgeons.
- 1 January 2006
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 2 (3) , 147-50
Open AccessInguinal hernia recurrence: Classification and approach
Journal of Minimal Access Surgery (JMAS), the official publication of Indian Association of Gastrointestinal Endo Surgeons.
- Open Access
- 1 January 2006
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 2 (3) , 129-33
A modified Lichtenstein hernia repair using fibrin glue
In recent years, general surgeons who perform inguinal hernia repair have paid attention to successful reduction in the recurrence rate. The Lichtenstein technique is widely used because it is easy to learn and is associated with a low rate of complication and recurrences. Today, the new objective in primary hernia surgery should be to reduce complications such as chronic pain. Chronic pain after hernia repair can be disabling, with considerable impact on quality of life and there is evidence to suggest increased use of health services by patients who have chronic pain. We have proposed an international randomized controlled trial with seven referenced European centers: The TI.ME.LI. trial. The aim of this study is to evaluate pain and further disabling complications in patients undergoing Lichtenstein technique for primary inguinal hernia repair by fixing the mesh with fibrin sealant versus sutures (control group).
- 1 January 2006
- Published by Medknow in Journal of Minimal Access Surgery
- Vol. 2 (3) , 129-33
Open AccessA modified Lichtenstein hernia repair using fibrin glue
In recent years, general surgeons who perform inguinal hernia repair have paid attention to successful reduction in the recurrence rate. The Lichtenstein technique is widely used because it is easy to learn and is associated with a low rate of complication and recurrences. Today, the new objective in primary hernia surgery should be to reduce complications such as chronic pain. Chronic pain after hernia repair can be disabling, with considerable impact on quality of life and there is evidence to suggest increased use of health services by patients who have chronic pain. We have proposed an international randomized controlled trial with seven referenced European centers: The TI.ME.LI. trial. The aim of this study is to evaluate pain and further disabling complications in patients undergoing Lichtenstein technique for primary inguinal hernia repair by fixing the mesh with fibrin sealant versus sutures (control group).
- 1 September 2005
- Published by Springer Nature in Hernia
- Vol. 9 (3) , 305-306
This reply refers to the Letter to the Editor at http://dx.doi.org/10.1007/s10029-005-0336-8
- 1 September 2005
- Published by Springer Nature in Hernia
- Vol. 9 (3) , 305-306
This reply refers to the Letter to the Editor at http://dx.doi.org/10.1007/s10029-005-0336-8
- 21 December 2004
- Published by Springer Nature in Hernia
- Vol. 9 (1) , 3-5
Spigelian Hernia
We report on the evolution in concept and techniques that allowed us to improve the treatment of spigelian hernia, operable in day surgery in 90% of cases and through a preperitoneal and recently a preperitoneal and subfascial prosthetic repair (PHS). Background data. We propose an innovative use of the PHS mesh for spigelian hernia repair. With this new implementation, we confront the standard surgical technique and its postoperative period. Methods. From January 1992 to March 2004, we performed 2,500 hernia surgical operations, including 32 spigelian hernia repairs (1.3% of total case series). The first surgical approach used for 20 of these 32 patients (62.5% of total spigelian hernias), all electively operated on, was a classical preperitoneal repair (Wantz), performed when possible by size of defect and weight (Body Mass Index) of the patient, under local anesthesia and on a day-surgery basis. Our new modified technique takes place through the insertion of a PHS large-type mesh, whose bottom underlay portion lies flat in the preperitoneal space with the connector obliterating the hernial orifice and with the overlay portion lying on the internal oblique muscle, covered by the aponeurosis of the external oblique muscle. Results. Our modification to the classical technique consisted only in the application of a product, such as the PHS, in a hernia defect, which presented with an orifice of the size of the connector and, therefore, was easily repairable with the use of the PHS device. This approach is easier than the preperitoneal approach, it’s always suitable for local anaesthesia, and it gives a more comfortable postoperative period. The surgical approach may be performed completely in day surgery. Conclusions. We believe that spigelian hernia surgical repair should always be performed by means of a preperitoneal prosthesis under local anaesthesia when the patient’s clinical and physical conditions allow for it, always in day surgery, and using the PHS mesh when the hernia defect size fits with the connector diameter. This last possibility seems to be easier and more comfortable for the patient in the postoperative period.
- 21 December 2004
- Published by Springer Nature in Hernia
- Vol. 9 (1) , 3-5
Spigelian Hernia
We report on the evolution in concept and techniques that allowed us to improve the treatment of spigelian hernia, operable in day surgery in 90% of cases and through a preperitoneal and recently a preperitoneal and subfascial prosthetic repair (PHS). Background data. We propose an innovative use of the PHS mesh for spigelian hernia repair. With this new implementation, we confront the standard surgical technique and its postoperative period. Methods. From January 1992 to March 2004, we performed 2,500 hernia surgical operations, including 32 spigelian hernia repairs (1.3% of total case series). The first surgical approach used for 20 of these 32 patients (62.5% of total spigelian hernias), all electively operated on, was a classical preperitoneal repair (Wantz), performed when possible by size of defect and weight (Body Mass Index) of the patient, under local anesthesia and on a day-surgery basis. Our new modified technique takes place through the insertion of a PHS large-type mesh, whose bottom underlay portion lies flat in the preperitoneal space with the connector obliterating the hernial orifice and with the overlay portion lying on the internal oblique muscle, covered by the aponeurosis of the external oblique muscle. Results. Our modification to the classical technique consisted only in the application of a product, such as the PHS, in a hernia defect, which presented with an orifice of the size of the connector and, therefore, was easily repairable with the use of the PHS device. This approach is easier than the preperitoneal approach, it’s always suitable for local anaesthesia, and it gives a more comfortable postoperative period. The surgical approach may be performed completely in day surgery. Conclusions. We believe that spigelian hernia surgical repair should always be performed by means of a preperitoneal prosthesis under local anaesthesia when the patient’s clinical and physical conditions allow for it, always in day surgery, and using the PHS mesh when the hernia defect size fits with the connector diameter. This last possibility seems to be easier and more comfortable for the patient in the postoperative period.
- 16 December 2004
- Published by Springer Nature in Hernia
- Vol. 9 (1) , 108
Reply to ?About prosthetic repair and contaminaded areas? DOI 10.1007/s10029-004-0299-1, published in Hernia Volume 9, Issue 1, 2005
- 16 December 2004
- Published by Springer Nature in Hernia
- Vol. 9 (1) , 108
Reply to ?About prosthetic repair and contaminaded areas? DOI 10.1007/s10029-004-0299-1, published in Hernia Volume 9, Issue 1, 2005
- 16 June 2004
- Published by Springer Nature in Hernia
- Vol. 8 (3) , 190-192
Prosthetic repair, intestinal resection, and potentially contaminated areas: Safe and feasible?
Prosthetic repair for abdominal wall hernia currently represents the gold standard. However, it is still difficult to identify the correct indication for prosthetic implant in borderline cases. The authors propose evaluating whether a prosthetic implant is absolutely contraindicated in potentially infected operating fields through the review of literature and personal experience. The authors performed ten prosthetic hernia repairs in potentially contaminated areas, with a preliminary preparation of the retromuscular-preperitoneal space hosting the prosthesis implant, and subsequent performance of the major operation. There were neither major nor minor complications with a 21-month follow-up (mean period). It is certain that both in noncomplicated inguinal hernia and in abdominal wall hernia repairs, the use of antibiotics can significantly reduce the number of infections. It is very important to underline that the success of the described procedure can be guaranteed only by an accurate preparation of the preperitoneal space: perfect haemostasis, temporary closure of the space with the insertion of iodine gauzes and suturing the edges, local antibiotic treatment, washing of the cavity, and accurate drainage. Prosthetic repair is the gold standard for inguinal, incisional, and all abdominal wall hernias and should be used, with the method described, even in potentially contaminated areas. The use of a prosthesis has to be avoided in clearly infected cases.
- 16 June 2004
- Published by Springer Nature in Hernia
- Vol. 8 (3) , 190-192
Prosthetic repair, intestinal resection, and potentially contaminated areas: Safe and feasible?
Prosthetic repair for abdominal wall hernia currently represents the gold standard. However, it is still difficult to identify the correct indication for prosthetic implant in borderline cases. The authors propose evaluating whether a prosthetic implant is absolutely contraindicated in potentially infected operating fields through the review of literature and personal experience. The authors performed ten prosthetic hernia repairs in potentially contaminated areas, with a preliminary preparation of the retromuscular-preperitoneal space hosting the prosthesis implant, and subsequent performance of the major operation. There were neither major nor minor complications with a 21-month follow-up (mean period). It is certain that both in noncomplicated inguinal hernia and in abdominal wall hernia repairs, the use of antibiotics can significantly reduce the number of infections. It is very important to underline that the success of the described procedure can be guaranteed only by an accurate preparation of the preperitoneal space: perfect haemostasis, temporary closure of the space with the insertion of iodine gauzes and suturing the edges, local antibiotic treatment, washing of the cavity, and accurate drainage. Prosthetic repair is the gold standard for inguinal, incisional, and all abdominal wall hernias and should be used, with the method described, even in potentially contaminated areas. The use of a prosthesis has to be avoided in clearly infected cases.
- 1 August 2003
- Vol. 58 (4) , 601-3, 604
Difficult hernia repair in the elderly. A particular case.
A particular clinical case personally observed is described. On the basis of this case it is evaluated if it can be correct to implant a mesh in potentially contaminated areas, if preperitoneal repair is the best approach in recurrent or difficult hernia repair and if there are specific contraindications in operating elderly patients.
- 1 August 2003
- Vol. 58 (4) , 601-3, 604
Difficult hernia repair in the elderly. A particular case.
A particular clinical case personally observed is described. On the basis of this case it is evaluated if it can be correct to implant a mesh in potentially contaminated areas, if preperitoneal repair is the best approach in recurrent or difficult hernia repair and if there are specific contraindications in operating elderly patients.