Maciej Śmietański
Research Subjects
Research Interests
Maciej Śmietański has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Kamil Bury
Department of Cardiac and Vascular Surgery, Medical University of Gdansk, Gdansk, Poland
5 shared publications - Agnieszka Tomaszewska
Politechnika Gdańska, Wydział Inżynierii Lądowej i Środowiska
2 shared publications - Andrzej Modrzejewski
Laboratory of Surgical and Emergency Nursing, Pomeranian Medical University, Szczecin, Poland
2 shared publications Czesław Szymczak
2 shared publicationsI. A. Śmietańska
Medical University of Gdansk
2 shared publications- Izabela Lubowiecka
Department of Structural Mechanics, Faculty of Civil and Environmental Engineering Gdańsk University of Technology Gdańsk Poland
2 shared publications
Latest Publications
- 30 November 2012
- Published by Springer Nature
- p. 309-313
Lumbar Hernia
- 24 July 2012
- Published by Springer Nature in Hernia
- Vol. 16 (5) , 519-528
Systematic review and meta-analysis on heavy and lightweight polypropylene mesh in Lichtenstein inguinal hernioplasty
Recurrence and pain are the two most important outcomes after inguinal hernia surgery. The concept of lightweight or partially absorbable macroporous meshes was developed under the assumption that the observed pain rate could be decreased without increasing the number of recurrences. Few randomized trials were published to analyze their clinical value, and some concern was raised because of an increased risk of recurrence. A systematic review and a meta-analysis of RCTs were carried out to determine whether the use of lightweight meshes influenced the pain and recurrence rate after Lichtenstein hernioplasty. To assess the value of the lightweight mesh, an extensive literature search was performed. The random-effect meta-analysis model was used to correct for clinical diversity and methodological variations between studies. Recurrence rate, aspects of chronic pain and foreign body feeling at 6–60 months postoperatively were assessed. Eight prospective RCTs of good quality were identified. Analysis demonstrated no significant difference regarding recurrence (OR, 1.11; 95 % CI, 0.57–2.14; p = 0.77). No significant difference was observed concerning severe pain (OR, 0.99; 95 % CI, 0.48–2.02; p = 0.97). Description of any pain resulted in a significant improvement in the lightweight group (OR, 0.65; 95 % CI, 0.50–0.84; p = 0.001). The presence of foreign body feeling was favoring the lightweight group (OR, 0.62; 95 % CI, 0.41–0.94; p = 0.02). The use of lightweight mesh did not neither increase the recurrence rate nor reduce the incidence of severe pain. A significant reduction in foreign body feeling and overall pain rate in the postoperative period was recorded. Lightweight meshes could be considered as a material of choice in primary inguinal hernioplasty.
- 24 July 2012
- Published by Springer Nature in Hernia
- Vol. 16 (5) , 519-528
Systematic review and meta-analysis on heavy and lightweight polypropylene mesh in Lichtenstein inguinal hernioplasty
Recurrence and pain are the two most important outcomes after inguinal hernia surgery. The concept of lightweight or partially absorbable macroporous meshes was developed under the assumption that the observed pain rate could be decreased without increasing the number of recurrences. Few randomized trials were published to analyze their clinical value, and some concern was raised because of an increased risk of recurrence. A systematic review and a meta-analysis of RCTs were carried out to determine whether the use of lightweight meshes influenced the pain and recurrence rate after Lichtenstein hernioplasty. To assess the value of the lightweight mesh, an extensive literature search was performed. The random-effect meta-analysis model was used to correct for clinical diversity and methodological variations between studies. Recurrence rate, aspects of chronic pain and foreign body feeling at 6–60 months postoperatively were assessed. Eight prospective RCTs of good quality were identified. Analysis demonstrated no significant difference regarding recurrence (OR, 1.11; 95 % CI, 0.57–2.14; p = 0.77). No significant difference was observed concerning severe pain (OR, 0.99; 95 % CI, 0.48–2.02; p = 0.97). Description of any pain resulted in a significant improvement in the lightweight group (OR, 0.65; 95 % CI, 0.50–0.84; p = 0.001). The presence of foreign body feeling was favoring the lightweight group (OR, 0.62; 95 % CI, 0.41–0.94; p = 0.02). The use of lightweight mesh did not neither increase the recurrence rate nor reduce the incidence of severe pain. A significant reduction in foreign body feeling and overall pain rate in the postoperative period was recorded. Lightweight meshes could be considered as a material of choice in primary inguinal hernioplasty.
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S346
EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPIC VENTRAL HERNIA REPAIR IMPROVEMENT
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S346
EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPIC VENTRAL HERNIA REPAIR IMPROVEMENT
- Open Access
- 10 May 2012
- Published by Springer Nature in Hernia
- Vol. 16 (5) , 549-553
Five-year results of a randomized clinical trial comparing a polypropylene mesh with a poliglecaprone and polypropylene composite mesh for inguinal hernioplasty
Background The aim of this study was to assess whether partially absorbable monofilament mesh could influence postoperative pain and recurrence after Lichtenstein hernioplasty over the long term. Methods Patients were randomized into two groups that were treated with lightweight (LW) or heavyweight (HW) mesh in 15 centers in Poland. A modified suture technique was used in the lightweight mesh group. Clinical examination was performed. A pain questionnaire was completed five years after the surgery. Results Of the 392 patients who underwent surgery, 161 (90.81 %) of 177 in the HW group and 195 (90.69 %) of 215 in the LW group were examined according to protocol, a median of 62 (range 57–66) months after hernia repair. There was no difference in the recurrence rate (1.9 % LW vs. 0.6 % HW; P = 0.493). There were 24 deaths in the follow-up period, but these had no connection to the surgery. The patients treated with LW mesh reported less pain in the early postoperative period. After five years of follow-up, the intensity and the presence of pain did not differ between groups (5 patients in the LW and 4 patients in the HW group). Average pain, (VAS score), was also similar in the LW and HW group (2.25 vs. 2.4) at the fifth year postoperatively. Conclusion The use of partially absorbable mesh reduced postoperative pain during the short-term postoperative period. No difference in pain or recurrence rate was observed at 60 months.
- 10 May 2012
- Published by Springer Nature in Hernia
- Vol. 16 (5) , 549-553
Open AccessFive-year results of a randomized clinical trial comparing a polypropylene mesh with a poliglecaprone and polypropylene composite mesh for inguinal hernioplasty
Background The aim of this study was to assess whether partially absorbable monofilament mesh could influence postoperative pain and recurrence after Lichtenstein hernioplasty over the long term. Methods Patients were randomized into two groups that were treated with lightweight (LW) or heavyweight (HW) mesh in 15 centers in Poland. A modified suture technique was used in the lightweight mesh group. Clinical examination was performed. A pain questionnaire was completed five years after the surgery. Results Of the 392 patients who underwent surgery, 161 (90.81 %) of 177 in the HW group and 195 (90.69 %) of 215 in the LW group were examined according to protocol, a median of 62 (range 57–66) months after hernia repair. There was no difference in the recurrence rate (1.9 % LW vs. 0.6 % HW; P = 0.493). There were 24 deaths in the follow-up period, but these had no connection to the surgery. The patients treated with LW mesh reported less pain in the early postoperative period. After five years of follow-up, the intensity and the presence of pain did not differ between groups (5 patients in the LW and 4 patients in the HW group). Average pain, (VAS score), was also similar in the LW and HW group (2.25 vs. 2.4) at the fifth year postoperatively. Conclusion The use of partially absorbable mesh reduced postoperative pain during the short-term postoperative period. No difference in pain or recurrence rate was observed at 60 months.
- Open Access
- 1 January 2012
- Published by Termedia Sp. z.o.o. in Videosurgery and Other Miniinvasive Techniques
- Vol. 1 (1) , 59-62
Postoperative interstitial hernia as a cause of obscure incisional wound site pain
An interstitial hernia is one in which the hernia sac is located between the layers of the abdominal wall. The analysis of contemporary literature shows that interstitial hernias are most often seen in children as a type of inguinal hernia and often accompany undescended testis. The hernia sac...
- 1 January 2012
- Published by Termedia Sp. z.o.o. in Videosurgery and Other Miniinvasive Techniques
- Vol. 1 (1) , 59-62
Open AccessPostoperative interstitial hernia as a cause of obscure incisional wound site pain
An interstitial hernia is one in which the hernia sac is located between the layers of the abdominal wall. The analysis of contemporary literature shows that interstitial hernias are most often seen in children as a type of inguinal hernia and often accompany undescended testis. The hernia sac...
- 15 December 2011
- Published by Springer Nature in Surgical Endoscopy
- Vol. 26 (5) , 1461-1467
Biomechanics of the front abdominal wall as a potential factor leading to recurrence with laparoscopic ventral hernia repair
Intraabdominal pressure often is blamed as the cause of mesh–fascia junction failure after laparoscopic ventral hernia repair. Stretching of the mesh during a cough or defecation may lead to recurrence. Little is known about the movements of mesh in the abdominal cavity after this operation. This study investigated the front abdominal wall to describe its elasticity in vivo and searched for elongations that possibly stretched an implanted mesh, thereby causing fixation failure and subsequent recurrence. To measure front abdominal wall elongations, a model of fascia movements was created. Eight healthy volunteers were measured during exercise to determine the extent of elongations in their front abdominal wall. Videos were analyzed in three positions to create a mathematical shell structure. A computerized model based on the net movement of nodes was calculated to determine the axes and values for maximum elongations. The largest average elongations were measured for the upper midline (32.08%) and the transverse line in the low lateral area (34.06%). The maximum values for these lines were larger than 100% for the middle line (133.78%) and exceeded 50% for the entire middle line. The values for the horizontal lines did not reach 10% at any level. According to these data, areas of both high and low elasticity were defined. The presented experiment adds new parameters to the understanding of in vivo mesh behavior. Elongation of the front abdominal wall may stretch implanted mesh and could be a cause of recurrence in cases of insufficient fixation.
- 15 December 2011
- Published by Springer Nature in Surgical Endoscopy
- Vol. 26 (5) , 1461-1467
Biomechanics of the front abdominal wall as a potential factor leading to recurrence with laparoscopic ventral hernia repair
Intraabdominal pressure often is blamed as the cause of mesh–fascia junction failure after laparoscopic ventral hernia repair. Stretching of the mesh during a cough or defecation may lead to recurrence. Little is known about the movements of mesh in the abdominal cavity after this operation. This study investigated the front abdominal wall to describe its elasticity in vivo and searched for elongations that possibly stretched an implanted mesh, thereby causing fixation failure and subsequent recurrence. To measure front abdominal wall elongations, a model of fascia movements was created. Eight healthy volunteers were measured during exercise to determine the extent of elongations in their front abdominal wall. Videos were analyzed in three positions to create a mathematical shell structure. A computerized model based on the net movement of nodes was calculated to determine the axes and values for maximum elongations. The largest average elongations were measured for the upper midline (32.08%) and the transverse line in the low lateral area (34.06%). The maximum values for these lines were larger than 100% for the middle line (133.78%) and exceeded 50% for the entire middle line. The values for the horizontal lines did not reach 10% at any level. According to these data, areas of both high and low elasticity were defined. The presented experiment adds new parameters to the understanding of in vivo mesh behavior. Elongation of the front abdominal wall may stretch implanted mesh and could be a cause of recurrence in cases of insufficient fixation.
- Open Access
- 25 March 2011
- Published by Springer Nature in Hernia
- Vol. 15 (5) , 495-501
Five-year results of a randomised controlled multi-centre study comparing heavy-weight knitted versus low-weight, non-woven polypropylene implants in Lichtenstein hernioplasty
Background This prospective randomised study evaluated whether non-knitted and non-woven lightweight implants can influence postoperative pain and time of return to normal activity, without increasing the recurrence rate in Lichtenstein inguinal hernioplasty. Methods Patients were operated on in four centres, randomised blindly into two groups with respect to the mesh used: Surgimesh WN (non-woven polypropylene microfibre sheet) and heavy weight polypropylene mesh. The operation was performed according to the Lichtenstein technique. Follow-up was designed for 7 days, and 3, 6, 12 and 60 months. The objectives were to assess the incidence of early and late complications, recurrence rate, and postoperative pain. Results A total of 220 patients were randomised; after monitoring visits (exclusion of one hospital), 202 qualified for the assessment. At 60 months, the recurrence rate did not differ statistically. Less pain on the 7th postoperative day, and at 3 months, was observed in the WN group. No other differences were observed. Conclusions Use of a lightweight non-woven polypropylene implant is a valuable alternative to the use of knitted or woven meshes in the Lichtenstein method. Postoperative pain and recurrence were reduced at short term follow-up, but no statistical difference in recurrence rate was observed at 12 and 60 month follow-up in the patient population tested.
- 25 March 2011
- Published by Springer Nature in Hernia
- Vol. 15 (5) , 495-501
Open AccessFive-year results of a randomised controlled multi-centre study comparing heavy-weight knitted versus low-weight, non-woven polypropylene implants in Lichtenstein hernioplasty
Background This prospective randomised study evaluated whether non-knitted and non-woven lightweight implants can influence postoperative pain and time of return to normal activity, without increasing the recurrence rate in Lichtenstein inguinal hernioplasty. Methods Patients were operated on in four centres, randomised blindly into two groups with respect to the mesh used: Surgimesh WN (non-woven polypropylene microfibre sheet) and heavy weight polypropylene mesh. The operation was performed according to the Lichtenstein technique. Follow-up was designed for 7 days, and 3, 6, 12 and 60 months. The objectives were to assess the incidence of early and late complications, recurrence rate, and postoperative pain. Results A total of 220 patients were randomised; after monitoring visits (exclusion of one hospital), 202 qualified for the assessment. At 60 months, the recurrence rate did not differ statistically. Less pain on the 7th postoperative day, and at 3 months, was observed in the WN group. No other differences were observed. Conclusions Use of a lightweight non-woven polypropylene implant is a valuable alternative to the use of knitted or woven meshes in the Lichtenstein method. Postoperative pain and recurrence were reduced at short term follow-up, but no statistical difference in recurrence rate was observed at 12 and 60 month follow-up in the patient population tested.
- Open Access
- 1 January 2010
- Published by Termedia Sp. z.o.o. in Videosurgery and Other Miniinvasive Techniques
- Vol. 4, 161-165
Ventral hernia following lymphocele fenestration in a patient after renal transplantation – a and treatment strategy
Introduction : Lymphocele is a common finding after renal transplantation. The frequency of this complication is up to 38%; of these, only 10% need surgical treatment. Unfortunately, hernia may be observed as a consequence of a lymphocele or its treatment. Aim : To show the need for a...
- 1 January 2010
- Published by Termedia Sp. z.o.o. in Videosurgery and Other Miniinvasive Techniques
- Vol. 4, 161-165
Open AccessVentral hernia following lymphocele fenestration in a patient after renal transplantation – a and treatment strategy
Introduction : Lymphocele is a common finding after renal transplantation. The frequency of this complication is up to 38%; of these, only 10% need surgical treatment. Unfortunately, hernia may be observed as a consequence of a lymphocele or its treatment. Aim : To show the need for a...