BRBruce J. Ramshaw

Bruce J. Ramshaw

*This is an algorithmically generated author record based on publicly available information.

Bruce J. Ramshaw has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 13 January 2017
      • Vol. 30, 155-164

    Real-World Clinical Quality Improvement for Complex Abdominal Wall Reconstruction.

    by Bruce Ramshaw, Brandie Remi Forman, Karla Moore, Eric Heidel, Michael Fabian, Greg Mancini, Girish P Joshi

    Traditional methods of clinical research may not be adequate to improve the value of care for patients undergoing abdominal wall reconstruction (AWR). These patients are prone to high complication rates and high costs. Here, we describe a clinical quality improvement (CQI) effort to enhance outcomes for patients undergoing AWR. CQI was applied for the entire care cycle for consecutive patients who underwent AWR from August 2011-September 2015. Initiatives for improving value during this period included use of long-term resorbable synthetic mesh as well as administration of preoperative bilateral transversus abdominus plane (TAP), and intraoperative abdominal wall blocks using long-acting bupivacaine as a part of a multimodal regimen. Outcomes data that measure value in the context of AWR were collected to compare outcomes for the patients who received TAP blocks only, TAP and intraoperative blocks, and those who received no block. One hundred and two patients who had AWR for abdominal wall pathology were included. Outcomes including total opioid use, duration of stay and opioid use in the postanesthesia care unit (PACU), length of hospital stay (LOS), major wound complications, and costs, all improved over time. Specifically, PACU opioid use, total opioid use, and LOS were decreased in the two groups that received blocks versus a group that did not have any type of block. CQI program implementation in patients undergoing AWR resulted in measurable improvement of value-based outcomes over time. A CQI effort applied to the entire patient cycle of care should be routinely utilized.


    • 1 May 2015
      • Vol. 26, 135-42

    Value-based Clinical Quality Improvement (CQI) for Patients Undergoing Abdominal Wall Reconstruction.

    by Bradley Stephan, Bruce Ramshaw, Brandie Forman

    Patients with complex ventral/incisional hernias often undergo an abdominal wall reconstruction (AWR). These operations have a high cost of care and often result in a long hospital stay and high complication rates. Using the principles of clinical quality improvement (CQI), several attempts at process improvement were implemented in one hernia program over a 3-year period. For consecutive cases of patients undergoing abdominal wall reconstruction, process improvement attempts included the use of a long-term resorbable synthetic mesh (TIGR® Resorbable Matrix, Novus Scientific, Uppsala, Sweden) in place of a biologic mesh, the use of the transversus abdominis release approach in place of an open or endoscopic component separation (external oblique release) technique, and the use of a preoperative transversus abdominis plane (TAP) block using a long-acting local anesthetic (Exparel®, Pacira Pharmaceutical, Parsippany, NJ) as a part of perioperative multi-modal pain management and an enhanced recovery program. After over 60 cases, improvement in materials costs and postoperative outcomes were documented. No mesh-related complications occurred and no mesh removal was required. In this real-world, value-based application of CQI, several attempts at process improvement led to decreased costs and improved outcomes for patients who underwent abdominal wall reconstruction for complex ventral/incisional hernias. Value-based CQI could be a tool for improved health care value globally.


  • Erratum to: 16th Annual Hernia Repair, Las Vegas

    by Bruce J. Ramshaw

  • 16th Annual Hernia Repair, Las Vegas

    by Bruce J. Ramshaw


  • Open Access

    Incisional hernia recurrence through genomic profiling: a pilot study

    by R. Calaluce, J. W. Davis, S. L. Bachman, M. M. Gubin, J. A. Brown, J. D. Magee, T. S. Loy, B. J. Ramshaw, U. Atasoy

    Purpose Although situational risk factors for incisional hernia formation are known, the methods used to determine who would be most susceptible to develop one are unreliable. We hypothesized that patients with recurrent incisional hernias may possess unique gene expression profiles. Methods Skin and intact fascia were collected from 15 normal control (NC) patients with no hernia history and 18 patients presenting for recurrent incisional hernia (RH) repair. Microarray analysis was performed using whole genome microarray chips on NC (n = 8) and RH (n = 9). These samples were further investigated using a pathway-specific PCR array containing fibrosis-related genes. Results Microarray data revealed distinct differences in the gene expression profiles between RH and NC patients. One hundred and sixty-seven genes in the skin and 7 genes in the fascia were differentially expressed, including 8 directly involved in collagen synthesis. In particular, GREMLIN1, or bone morphogenetic protein antagonist 1, was under expressed in skin (fold = 0.49, p < 10−7, q = 0.0009) and fascia (fold = 0.23, p < 10−4, q = 0.095) of RH patients compared with NC. The PCR array data supported previous reports of decreased collagen I/III ratios in skin of RH versus NC (mean = 1.51 ± 0.73 vs. mean = 2.26 ± 0.99; one-sided t test, p = 0.058). Conclusion To our knowledge, this is the first microarray-based analysis to show distinct gene expression profiles between the skin and fascia of RH and NC patients and the first report of an association between GREMLIN1 and incisional hernia formation. Our results suggest that gene expression profiles may act as surrogate markers that stratify patients into different groups at risk for hernia development prior to their initial surgery.


  • Cognitive task analysis of the laparoscopic totally extraperitoneal (TEP) inguinal hernia repair: Efficiency, slow-down moments and teaching principles

    by Benjamin Zendejas, Sarah E. Peyre, Douglas Smink, James M. Swain, Bruce Ramshaw, Daniel C. Smith, George Ferzli, David R. Farley


  • Characterization of bionanocomposite scaffolds comprised of amine‐functionalized single‐walled carbon nanotubes crosslinked to an acellular porcine tendon

    by Corey R. Deeken, Matthew J. Cozad, Sharon L. Bachman, Bruce J. Ramshaw, Sheila A. Grant

    Carbon nanotubes (CNT) possess many unique electrical and mechanical properties that make them useful for a variety of industrial and biomedical applications. They are especially attractive materials for biomedical applications since their dimensions are similar to components of the extracellular matrix. In this study, amine-functionalized single-walled carbon nanotubes were crosslinked to an acellular porcine diaphragm tendon. The resulting bionanocomposite scaffolds were subjected to a number of materials characterization techniques including a collagenase assay, uniaxial tensile testing, modulated differential scanning calorimetry, and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy to determine whether the properties of the original extracellular matrix were altered by the treatment processes. A variety of SWCNT concentrations were investigated. While none of the conditions investigated resulted in bionanocomposites with significantly improved physicochemical properties, no detrimental effects were observed due to any of the processing steps. Future studies should be performed to determine if carbon nanotubes can influence cellular adhesion and function in order to promote rapid integration and remodeling. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A:, 2011.


  • Laparoscopic parastomal hernia repair using a nonslit mesh technique

    by G. J. Mancini, D. A. McClusky, L. Khaitan, E. A. Goldenberg, B. T. Heniford, Y. W. Novitsky, A. E. Park, S. Kavic, K. A. LeBlanc, M. J. Elieson, et al.

    The management of parastomal hernia is associated with high morbidity and recurrence rates (20–70%). This study investigated a novel laparoscopic approach and evaluated its outcomes. A consecutive multi-institutional series of patients undergoing parastomal hernia repair between 2001 and 2005 were analyzed retrospectively. Laparoscopy was used with modification of the open Sugarbaker technique. A nonslit expanded polytetrafluoroethylene (ePTFE) mesh was placed to provide 5-cm overlay coverage of the stoma and defect. Transfascial sutures secured the mesh, allowing the stoma to exit from the lateral edge. Five advanced laparoscopic surgeons performed all the procedures. The primary outcome measure was hernia recurrence. A total of 25 patients with a mean age of 60 years and a body mass index of 29 kg/m2 underwent surgery. Six of these patients had undergone previous mesh stoma revisions. The mean size of the hernia defect was 64 cm2, and the mean size of the mesh was 365 cm2. There were no conversions to open surgery. The overall postoperative morbidity was 23%, and the mean hospital length of stay was 3.3 days. One patient died of pulmonary complications; one patient had a trocar-site infection; and one patient had a mesh infection requiring mesh removal. During a median follow-up period of 19 months (range, 2–38 months), 4% (1/25) of the patients experienced recurrence. On the basis of this large case series, the laparoscopic nonslit mesh technique for the repair of parastomal hernias seems to be a promising approach for the reduction of hernia recurrence in experienced hands.


  • Relationship Between Tissue Ingrowth and Mesh Contraction

    by Rodrigo Gonzalez, Kim Fugate, David McClusky, E. Matt Ritter, Andrew Lederman, Dirk Dillehay, C. Daniel Smith, Bruce J. Ramshaw

    Contraction is a well‐documented phenomenon occurring within two months of mesh implantation. Its etiology is unknown, but it is suggested to occur as a result of inadequate tissue ingrowth into the mesh and has been associated with hernia recurrence. In continuation of our previous studies, we compared tissue ingrowth characteristics of large patches of polyester (PE) and heavyweight polypropylene (PP) and their effect on mesh contraction. The materials used were eight PE and eight PP meshes measuring 10 × 10 cm2. After random assignment to the implantation sites, the meshes were fixed to the abdominal wall fascia of swine using interrupted polypropylene sutures. A necropsy was performed three months after surgery for evaluation of mesh contraction/shrinkage. Using a tensiometer, tissue ingrowth was assessed by measuring the force necessary to detach the mesh from the fascia. Histologic analysis included inflammatory and fibroblastic reactions, scored on a 0–4 point scale. One swine developed a severe wound infection that involved two PP meshes and was therefore excluded from the study. The mean area covered by the PE meshes (87 ± 7 cm2) was significantly larger than the area covered by the PP meshes (67 ± 14 cm2) (p = 0.006). Tissue ingrowth force of the PE meshes (194 ± 37 N) had a trend toward being higher than that of the PP meshes (159 ± 43 N), although it did not reach statistical significance. There was no difference in histologic inflammatory and fibroblastic reactions between mesh types. There was a significant correlation between tissue ingrowth force and mesh size (p = 0.03, 95% CI: 0.05–0.84). Our results confirm those from previous studies in that mesh materials undergo significant contraction after suture fixation to the fascia. PE resulted in less contraction than polypropylene. A strong integration of the mesh into the tissue helps prevent this phenomenon, which is evidenced by a significant correlation between tissue ingrowth force and mesh size.