MNMarcus Neudert

Marcus Neudert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marcus Neudert has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • Thomas Zahnert

    Tech Univ Dresden, Med Fak, Dresden, Germany

    6 shared publications
  • Matthias Bornitz

    Department of Otorhinolaryngology, Head and Neck Surgery, Carl Gustav Carus Faculty of Medicine, TU Dresden, Dresden, Germany

    5 shared publications
  • Thomas Zahnert

    Carl Gustav Carus Faculty of Medicine, Clinic and Policlinic for Otorhinolaryngology, Head and Neck Surgery, Technische Universität Dresden, Dresden, Germany

    5 shared publications
  • Max Kemper

    Department of Otolaryngology, Head and Neck Surgery, Technische Universität Dresden, Dresden, Germany

    4 shared publications
  • Thomas Beleites

    Carl Gustav Carus Faculty of Medicine, Clinic and Policlinic for Otorhinolaryngology, Head and Neck Surgery, Technische Universität Dresden, Dresden, Germany

    4 shared publications
  • Christian Offergeld

    Klinik für Hals-Nasen-Ohrenheilkunde, Kopf- und Hals-Chirurgie, Medizinische Fakultät, Universitätsklinikum Freiburg, Albert-Ludwigs-Universität Freiburg, Freiburg, Deutschland

    3 shared publications

Latest Publications

  • Open Access

    Prospective study of the application of a 3D exoscope system (VITOM 3D) in ear surgery compared to conventional surgical microscopes: part I - analysis of objective parameters

    by Hai Yen Tao, Joseph Morgenstern, Christoph Müller, Nikoloz Lasurashvili, Thomas Zahnert, Thomas Beleites, Marcus Neudert

    Background: This prospective study compared the application of a 3D exoscope (VITOM 3D) with surgical microscopes (SM) in ear surgery. Methods: 62 patients were included (exoscope group (E+) n = 31; SM group (E-) n = 31). Procedures included cochlea implantation (nE + = 10, nE- = 10), reconstructive middle ear surgery due to chronic otitis media with (COMwC; nE + = 11, nE- = 11) and without cholesteatoma (COMsC; nE + = 10, nE- = 10). Objective (e.g. set-up time and wrap-up time, corrected cut-suture-time, pure operating time, adjustment time, time per adjustment procedure, learning curves) and subjective perioperative parameters were evaluated. This paper only addressed the analysis of the objective parameters. Results: The pooled data showed that the mean time delay in the E + group was significantly higher compared to the E- group with regard to set-up time and wrap-up time, corrected cut-suture time, adjustment time and time per adjustment procedure. Time delay tended to be higher for pure operating time. In all subgroups of the E + group, the objective time parameters also showed at least a tendency to be prolonged on average compared to the corresponding subgroups in the E- group. The learning curve analysis showed that the E + group (corrected cut suture time for CI surgery, mean time per adjustment procedure across all subgroups) approached the times of the E- group during the course of the study. Conclusions: Based on the pooled data from the study arms, the exoscope tends to be inferior to the microscope for the objective time parameters evaluated when used in ear surgery. However, due to the small group sizes, no solid conclusions could be drawn regarding the individual surgical procedures. In addition, further studies with a longer observation period are needed to minimize the influence of the learning curve on the results.


  • Open Access

    Auditory thresholds compatible with optimal speech reception likely evolved before the human-chimpanzee split

    by Alexander Stoessel, Romain David, Matthias Bornitz, Steffen Ossmann, Marcus Neudert

    The anatomy of the auditory region of fossil hominins may shed light on the emergence of human spoken language. Humans differ from other great apes in several features of the external, middle and inner ear (e.g., short external ear canal, small tympanic membrane, large oval window). However, the functional implications of these differences remain poorly understood as comparative audiometric data from great apes are scarce and conflicting. Here, we measure the sound transfer function of the external and middle ears of humans, chimpanzees and bonobos, using laser-Doppler vibrometry and finite element analysis. This sound transfer function affects auditory thresholds, which relate to speech reception thresholds in humans. Unexpectedly we find that external and middle ears of chimpanzees and bonobos transfer sound better than human ones in the frequency range of spoken language. Our results suggest that auditory thresholds of the last common ancestor of Homo and Pan were already compatible with speech reception as observed in humans. Therefore, it seems unlikely that the morphological evolution observed in the bony auditory region of fossil hominins was driven by the emergence of spoken language. Instead, the peculiar human configuration may be a by-product of morpho-functional constraints linked to brain expansion.


  • Weiterbildung – wo fängt sie an, wo hört sie auf?

    by Marcus Neudert, Mark Praetorius, Christian Offergeld


  • „ENT – expect no teaching“ …?!

    by C. Offergeld, M. Praetorius, M. Neudert


  • Open Access

    Qualität in der Mittelohrchirurgie – eine kritische Standortbestimmung

    by Marcus Neudert

    Zur Ergebnisbewertung der rekonstruktiven Mittelohrchirurgie nur die erzielte Verbesserung audiometrischer Messergebnisse heranzuziehen greift zu kurz. Auch wenn sie als funktionelle Parameter eine zentrale Stellung in der Therapiebewertung des Sinnesohrgans Ohr einnehmen, müssen sie für die moderne Qualitätsbeschreibung um eine Reihe von Faktoren ergänzt werden. Dabei sind die z. T. unterschiedlichen Perspektiven, aus denen ein qualitativ gutes Ergebnis bewertet wird, zu berücksichtigen. Aus Sicht des Patienten sind andere Faktoren ausschlaggebend als für den Arzt, für den Arzt wiederum andere als für die Kostenträger und die internationale otologische Gemeinschaft, die anhand von Ergebnissen gesicherte Erkenntnisse aus mittelohrchirurgischen Studiendaten ziehen möchte, setzt wieder andere Kriterien an, um die Qualität zu bewerten. Dazu wird der allgemeine Qualitätsbegriff auf die Mittelohrchirurgie adaptiert. Zudem muss er auf unterschiedlichen Ebenen gedacht und die chirurgische Therapie von Mittelohrerkrankungen als ganzer Prozess verstanden werden. Damit fallen neue Aspekte in die Qualitätsbewertung, die eine strukturierte Beschreibung und Erfassung krankheitsspezifischer Symptome, Befunde und das Behandlungsergebnis umfassen. Auch die Nutzung international anerkannter Klassifizierungssysteme, um die eigenen Ergebnisse nicht nur publizierbar sondern auch Meta-Analyse-fähig zu machen muss in der heutigen Zeit als ein Qualitätsmerkmal angesehen werden. Hierzu stehen international erarbeitete und anerkannte Berichtssysteme zur Verfügung. Ihre Anwendung in der Routineversorgung macht die erhobenen Daten dabei nicht nur international vergleichbar, sondern ermöglicht auch die systematische Bewertung innerhalb einer Institution zur Qualitätsbeschreibung. Neben audiologischen Messergebnissen werden chirurgische Qualitätsindikatoren betrachtet. Dabei wird der Blick auch auf eintretende Komplikationen und den Wert systematischer und strukturierter Erfassungssysteme gerichtet. Für die Nutzenbewertung durch die Patienten stehen mittlerweile validierte Messinstrumente zur Verfügung, deren Einsatz nicht mehr auf wissenschaftliche Studien beschränkt sein sollte. Zusammenfassend soll die Qualitätsbewertung nicht nur auf den „Patienten als Ganzes“, sondern auch den „Therapieprozess als Ganzes“, mit Einbeziehung von Merkmalen der Struktur- und Prozessqualität, ausgedehnt werden. When evaluating the outcome of reconstructive middle ear surgery, it is insufficient to use only the achieved improvement of audiometric measurement results. Although, as functional parameters, they occupy a central position in the therapeutic assessment of the ear as a sensory organ, they must be supplemented by a number of modern quality control factors. Different perspectives for assessment of quality must be taken into account. What is important from the patient’s point of view may not be the same factors as to the physician, while the physician places a high value on factors that are less significant for the medical insurance company. The international otological community, who would like to draw conclusions from middle ear surgery data, might set different criteria altogether for assessing quality of surgery. Hence, we propose to adapt the general concept of quality to middle ear surgery. This must be implemented on different levels and surgical therapy of middle ear diseases must be understood as a process. This means that new aspects must be included in quality assessment, This means that quality assessment must comprise additional aspects, which include a structured description and recording of disease-specific symptoms, findings, and outcome of treatment. Furthermore, in today’s world the use of internationally recognized classification systems must be regarded as a quality feature, in order to make results not only publishable but also capable of meta-analysis. Internationally developed and recognized reporting systems are available for this purpose. Their use in routine care not only makes the collected data internationally comparable, but also enables systematic evaluation within the institution for quality description and control. In addition to audiological measurement results, surgical quality indicators are considered. We also focus on emerging complications and the value of systematic and structured evaluation and documentation systems. Validated measuring instruments are already available for patient benefit assessment, the use of which should no longer be limited to scientific studies. In summary, quality assessment of surgery should be extended to include not only the “patient as a whole”, but also to the “therapy process as a whole”, incorporating features of structural and process quality.


  • Feasibility Study of a Mechanical Real-Time Feedback System for Optimizing the Sound Transfer in the Reconstructed Middle Ear

    by Marcus Neudert, Matthias Bornitz, Horia Mocanu, Nicoloz Lasurashvili, Thomas Beleites, Christian Offergeld, Thomas Zahnert

    To evaluate electromechanical excitation as an alternative excitation mode for middle ear transfer function (METF) measurements as well as real-time feedback in prosthetic ossicular reconstruction. In eight human cadaveric temporal bones, the ossicular chain was excited using acoustic and mechanical (floating mass transducer, FMT) stimulation to determine the METF. After disconnecting the ossicular chain and reconstruction with partial or total prosthesis the METFs were measured again. Continuous FMT stimulation was then applied to improve the prosthesis’ position using real-time feedback of the METF. Mechanical stimulation of ossicular vibration showed characteristic differences to acoustic excitation resulting from the force characteristics of the FMT. Furthermore, the interspecimen METF variability was greater with electromechanical than acoustic stimulation because of interspecimen variability in the FMT coupling conditions. When the METF with FMT excitation was used as a real-time feedback tool, a measurable improvement in the quality of ossicular reconstruction could be achieved. Mechanical excitation is an effective and suitable alternative stimulation method in experimental METF measurements. The system provides real-time feedback for ossicular reconstruction in the experimental setting. Some influencing factors still need to be distinguished for reliable measurements. However, the method does not yet meet the requirements for clinical application as an intraoperative, real-time monitoring tool. However, the system could be an excellent model for high-end cadaveric temporal bone training in ossiculoplasty.


  • Vorbereitung zur Facharztprüfung HNO

    by A. Darbinjan, M. Neudert

  • Vorbereitung zur Facharztprüfung HNO

    by A. Darbinjan, M. Neudert

  • Open Access

    Functional and morphological imaging of the human tympanic membrane with endoscopic optical coherence tomography

    by Lars Kirsten, Joseph Morgenstern, Mikael Timo Erkkilä, Martin Schindler, Jonas Golde, Julia Walther, Max Kemper, Thomas Stoppe, Matthias Bornitz, Marcus Neudert, et al.

    In this ex vivo feasibility study, endoscopic structural and functional optical coherence tomography (OCT) imaging with a field of view of 8 mm is presented allowing the inspection of nearly the entire tympanic membrane through the ear canal. The endoscope utilizes a gradient index optics for simultaneous OCT and video endoscopy. Additionally, Doppler-OCT allows the measurement of the tympanic membrane oscillation. Due to the fast image acquisition, only minor motion artifacts have been observed, which don’t affect the image quality. In conclusion, endoscopic OCT is considered as a promising tool for the comprehensive examination of the human middle ear.


  • Tympanoplastik – Neues und neu Beleuchtetes

    by Marcus Neudert, Thomas Zahnert

    Seit Beginn der rekonstruktiven Mittelohrchirurgie wurden Techniken und Biomaterialien zum Wiederaufbau des zerstörten Schallleitungsapparates beständig weiterentwickelt. Gleichzeitig wurden von Beginn an die Operationsergebnisse ausgewertet, um Erfolg oder Misserfolg der Therapien zu identifizieren. In den letzten Jahren nehmen Qualitätsbewertung und -sicherung im medizinischen Alltag einen wachsenden Stellenwert ein, der auch Einzug in die Mittelohrchirurgie hält. Bei der differenzierten und umfassenden Qualitätsbewertung kommt der exakten Definition und Erfassung der Zielparameter eine entscheidende Rolle zu. Diese umfasst heute nicht nur audiologische Daten, die prä- und postoperativ miteinander verglichen werden, sondern auch Bewertungen der individuellen Faktoren, die einen Einfluss auf das postoperative Gesamtergebnis nach einer Tympanoplastik haben, wie bspw. die gesundheitsspezifische Lebensqualität. Die Patientenselektion und Beschreibung der klinischen Ausgangssituation, der intraoperativ identifizierte Schaden am Schallleitungsapparat und die Rekonstruktionstechnik, die Wahl des Frequenzbereiches in der Audiometrie und das Nachbeobachtungsintervall sind nur einige der Faktoren, die die Ergebnisaussage beeinflussen. Werden sie nicht dokumentiert oder das Patientenkollektiv danach stratifiziert, sind die Aussagen einer Studie oder im Vergleich verschiedener Arbeiten nur bedingt aussagekräftig. Das vorliegende Referat soll daher eine Übersicht und Bewertung der Einflussfaktoren und der Bewertungsinstrumente liefern, um valide Aussagen aus klinischen Studien ziehen zu können. Weitere Bewertungsinstrumente für die intra- und postoperative Qualitätskontrolle stehen heute bereits in Studien zur Verfügung und liefern Aussagen über die intraoperative Rekonstruktionsqualität bzw. postoperativ über mögliche Ursachen nicht optimaler Hörergebnisse mittels Bildgebung. Im Bereich der Implantatentwicklung wurden in den letzten Jahren zunehmend funktionelle Elemente in die Mittelohrprothesen integriert, die nicht nur den Anforderungen der Schallübertragung genügen, sondern zudem atmosphärische Luftdruckschwankungen kompensieren können. Gerade in Kombination mit weiteren Implantat-Bausteinen und der Umsetzung eines modularen Prothesenkonzepts können experimentell wie klinisch vielversprechende Ergebnisse in Aussicht gestellt werden. Techniques and biomaterials for reconstructive middle ear surgery are under steady, ongoing development. At the same time, clinical post-surgery results are evaluated to determine success or failure of the therapy. Routine quality assessment and assurance is of growing importance in the medical field, and therefore also in middle ear surgery. The exact definition and acquisition of outcome parameters is essential for both a comprehensive and detailed quality assurance. These parameters are not the audiological results alone, but also additional individual parameters which influence the postoperative outcome after tympanoplasty. Selection of patients and the preoperative clinical situation, the extent of the ossicular chain destruction, the chosen reconstruction technique and material, the audiometric frequency selection and the observational interval are only some of them. If these parameters are not well documented comparative analyses between different studies are of limited value. The present overview aims to describe, compare and evaluate some of the existing assessment and scoring systems for middle ear surgery. Additionally, new methods for an intraoperative quality assessment in ossiculoplasty and the postoperative evaluation of suboptimal hearing results with imaging techniques are available. In the area of implant development functional elements were integrated in prostheses to enable not only good sound transmission but also compensation of occurring atmospheric pressure changes. In combination with other components for ossicular repair they can be used in a modular manner which, so far show experimentally and clinically promising results.