Sunil Puria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sunil Puria has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Charles R. Steele
Mechanical Engineering, Stanford University, Stanford, CA, USA
11 shared publications- Charles Steele
Mechanical Engineering, Stanford University, CA, USA
3 shared publications - Jin-Ho Cho
Institute of Biomedical Engineering Research, Kyungpook National University, 680, Gukchaebosang-ro, Jung-gu, Daegu 41944, Korea
3 shared publications - Dong Ho Shin
Institute of Biomedical Engineering Research, Kyungpook National University, Daegu, 41944, Korea
2 shared publications Jonathan P. Fay
Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
2 shared publications- Ki Woong Seong
Department of Biomedical Engineering, Kyungpook National University Hospital, 130 Dongdeok-ro, Jung-gu, Daegu 41944, Korea
2 shared publications
Latest Publications
- 1 November 2016
- Published by Elsevier in Hearing Research
- Vol. 341, 144-154
A tri-coil bellows-type round window transducer with improved frequency characteristics for middle-ear implants
- 1 November 2016
- Published by Elsevier in Hearing Research
- Vol. 341, 144-154
A tri-coil bellows-type round window transducer with improved frequency characteristics for middle-ear implants
- 12 March 2016
- Published by Wiley in The Laryngoscope
- Vol. 126 (11) , 2559-2564
First results of a novel adjustable‐length ossicular reconstruction prosthesis in temporal bones
Objectives/Hypothesis: The performance of an ossicular replacement prosthesis (ORP) is influenced by its alignment and appropriate tension between the tympanic membrane and the stapes footplate. A novel ORP with a flexible element that potentially allows for length adjustment in situ is presented and tested for acoustic performance.Study Design: Laser Doppler vibrometry in fresh human cadaveric temporal bones was used to test the acoustic performance of the adjustable ORP relative to standard prostheses used for ossiculoplasty.Methods: The three‐dimensional (3D) velocity of the stapes posterior crus was measured in the 0.2‐ to 20‐kHz range using a Polytec CLV‐3D laser Doppler vibrometer. The middle ear cavity was accessed through a facial recess approach. After measuring the normal response, the incus was removed and stapes velocity was measured in the disarticulated case, then after insertion of the new prosthesis, a conventional prosthesis (Kurz BELL Dusseldorf type), and a sculpted autologous incus prosthesis in each temporal bone. The 3D stapes velocity transfer function (SVTF) was calculated for each case and compared.Results: The novel ORP design restored stapes velocity to within 6 dB (on average) of the intact response. No significant differences in 3D‐SVTF were found between the new, conventional, or autologous ORPs.Conclusions: The inclusion of an in situ adjustable element into the ORP design did not adversely affect its acoustic performance. The adjustable element may increase the ease of achieving optimal ORP placement, especially through a facial recess approach.Level of Evidence: NA Laryngoscope, 126:2559–2564, 2016
- 12 March 2016
- Published by Wiley in The Laryngoscope
- Vol. 126 (11) , 2559-2564
First results of a novel adjustable‐length ossicular reconstruction prosthesis in temporal bones
Objectives/Hypothesis: The performance of an ossicular replacement prosthesis (ORP) is influenced by its alignment and appropriate tension between the tympanic membrane and the stapes footplate. A novel ORP with a flexible element that potentially allows for length adjustment in situ is presented and tested for acoustic performance.Study Design: Laser Doppler vibrometry in fresh human cadaveric temporal bones was used to test the acoustic performance of the adjustable ORP relative to standard prostheses used for ossiculoplasty.Methods: The three‐dimensional (3D) velocity of the stapes posterior crus was measured in the 0.2‐ to 20‐kHz range using a Polytec CLV‐3D laser Doppler vibrometer. The middle ear cavity was accessed through a facial recess approach. After measuring the normal response, the incus was removed and stapes velocity was measured in the disarticulated case, then after insertion of the new prosthesis, a conventional prosthesis (Kurz BELL Dusseldorf type), and a sculpted autologous incus prosthesis in each temporal bone. The 3D stapes velocity transfer function (SVTF) was calculated for each case and compared.Results: The novel ORP design restored stapes velocity to within 6 dB (on average) of the intact response. No significant differences in 3D‐SVTF were found between the new, conventional, or autologous ORPs.Conclusions: The inclusion of an in situ adjustable element into the ORP design did not adversely affect its acoustic performance. The adjustable element may increase the ease of achieving optimal ORP placement, especially through a facial recess approach.Level of Evidence: NA Laryngoscope, 126:2559–2564, 2016
- Open Access
- 21 January 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , srep19475-19475
Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss
Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.
- 21 January 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , srep19475-19475
Open AccessCochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss
Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.
- Open Access
A New Trans-Tympanic Microphone Approach for Fully Implantable Hearing Devices
Fully implantable hearing devices (FIHDs) have been developed as a new technology to overcome the disadvantages of conventional acoustic hearing aids. The implantable microphones currently used in FIHDs, however, have difficulty achieving high sensitivity to environmental sounds, low sensitivity to body noise, and ease of implantation. In general, implantable microphones may be placed under the skin in the temporal bone region of the skull. In this situation, body noise picked up during mastication and touching can be significant, and the layer of skin and hair can both attenuate and distort sounds. The new approach presently proposed is a microphone implanted at the tympanic membrane. This method increases the microphone’s sensitivity by utilizing the pinna’s directionally dependent sound collection capabilities and the natural resonances of the ear canal. The sensitivity and insertion loss of this microphone were measured in human cadaveric specimens in the 0.1 to 16 kHz frequency range. In addition, the maximum stable gain due to feedback between the trans-tympanic microphone and a round-window-drive transducer, was measured. The results confirmed in situ high-performance capabilities of the proposed trans-tympanic microphone.
Open AccessA New Trans-Tympanic Microphone Approach for Fully Implantable Hearing Devices
Fully implantable hearing devices (FIHDs) have been developed as a new technology to overcome the disadvantages of conventional acoustic hearing aids. The implantable microphones currently used in FIHDs, however, have difficulty achieving high sensitivity to environmental sounds, low sensitivity to body noise, and ease of implantation. In general, implantable microphones may be placed under the skin in the temporal bone region of the skull. In this situation, body noise picked up during mastication and touching can be significant, and the layer of skin and hair can both attenuate and distort sounds. The new approach presently proposed is a microphone implanted at the tympanic membrane. This method increases the microphone’s sensitivity by utilizing the pinna’s directionally dependent sound collection capabilities and the natural resonances of the ear canal. The sensitivity and insertion loss of this microphone were measured in human cadaveric specimens in the 0.1 to 16 kHz frequency range. In addition, the maximum stable gain due to feedback between the trans-tympanic microphone and a round-window-drive transducer, was measured. The results confirmed in situ high-performance capabilities of the proposed trans-tympanic microphone.
- 1 July 2014
- Published by Elsevier in Biophysical Journal
- Vol. 107 (1) , 233-241
The Importance of the Hook Region of the Cochlea for Bone-Conduction Hearing
- 1 July 2014
- Published by Elsevier in Biophysical Journal
- Vol. 107 (1) , 233-241
The Importance of the Hook Region of the Cochlea for Bone-Conduction Hearing
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4228
Acoustics-structure interactions in the human middle ear produce variety of motion modes at the malleus-incus complex
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4228
Acoustics-structure interactions in the human middle ear produce variety of motion modes at the malleus-incus complex
- 1 July 2013
- Published by Elsevier in Hearing Research
- Vol. 301, 72-84
Superior-semicircular-canal dehiscence: Effects of location, shape, and size on sound conduction
- 1 July 2013
- Published by Elsevier in Hearing Research
- Vol. 301, 72-84
Superior-semicircular-canal dehiscence: Effects of location, shape, and size on sound conduction
- 1 July 2013
- Published by Elsevier in Hearing Research
- Vol. 301, 2-3
MEMRO 2012 – Middle-ear bridge between science and otology
- 1 July 2013
- Published by Elsevier in Hearing Research
- Vol. 301, 2-3
MEMRO 2012 – Middle-ear bridge between science and otology
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5_Suppleme) , 3509
The elusive hair cell gating spring, a potential role for the lipid membrane
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5_Suppleme) , 3509
The elusive hair cell gating spring, a potential role for the lipid membrane