Timothy U. Jiya
Research Subjects
Research Interests
Timothy U. Jiya has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
B. J. van Royen
VU University Medical Centre and the Skeletal Tissue Engineering Group
2 shared publicationsA. Stadhouder
VU University Medical Centre and the Skeletal Tissue Engineering Group
1 shared publicationArthur Kleipool
Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
1 shared publicationJames Deddens
1 shared publicationJohn Ham
Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
1 shared publicationM. Mullender
Department of Orthopaedic Surgery, VU University Medical Centre and the Skeletal Tissue Engineering Group, Amsterdam, The Netherlands
1 shared publication
Latest Publications
- 23 March 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (11) , 2272-2278
The outcome and survival of palliative surgery in thoraco-lumbar spinal metastases: contemporary retrospective cohort study
- 23 March 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (11) , 2272-2278
The outcome and survival of palliative surgery in thoraco-lumbar spinal metastases: contemporary retrospective cohort study
- Open Access
- 15 September 2010
- Published by Springer Nature in European Spine Journal
- Vol. 20 (4) , 618-622
Posterior lumbar interbody fusion using non resorbable poly-ether-ether-ketone versus resorbable poly-l-lactide-co-d,l-lactide fusion devices. Clinical outcome at a minimum of 2-year follow-up
Previous papers on resorbable poly-l-lactide-co-d,l-lactide (PLDLLA) cages in spinal fusion have failed to report adequately on patient-centred clinical outcome measures. Also comparison of PLDLLA cage with a traditionally applicable counterpart has not been previously reported. This is the first randomized prospective study that assesses clinical outcome of PLDLLA cage compared with a poly-ether-ether-ketone (PEEK) implant. Twenty-six patients were randomly assigned to undergo instrumented posterior lumbar interbody fusion (PLIF) whereby either a PEEK cage or a PLDLLA cage was implanted. Clinical outcome based on visual analogue scale scores for leg pain and back pain, as well as Oswestry Disability Index (ODI) and SF-36 questionnaires were documented and analysed. When compared with preoperative values, all clinical parameters have significantly improved in the PEEK group at 2 years after surgery with the exception of SF-36 general health, SF-36 mental health and SF-36 role emotional scores. No clinical parameter showed significant improvement at 2 years after surgery compared with preoperative values in the PLDLLA patient group. Only six patients (50%) in the PLDLLA group showed improvement in the VAS scores for leg and back pain as well as the ODI, as opposed to 10 patients (71%) in the PEEK group. One-third of the patients in the PLDLLA group actually reported worsening of their pain scores and ODI. Three cases of mild to moderate osteolysis were seen in the PLDLLA group. Following up on our preliminary report, these 2-year results confirm the superiority of the PEEK implant to the resorbable PLDLLA implant in aiding spinal fusion and alleviating symptoms following PLIF in patients with degenerative spondylolisthesis associated with either canal stenosis or foramen stenosis or both and emanating from a single lumbar segment.
- 15 September 2010
- Published by Springer Nature in European Spine Journal
- Vol. 20 (4) , 618-622
Open AccessPosterior lumbar interbody fusion using non resorbable poly-ether-ether-ketone versus resorbable poly-l-lactide-co-d,l-lactide fusion devices. Clinical outcome at a minimum of 2-year follow-up
Previous papers on resorbable poly-l-lactide-co-d,l-lactide (PLDLLA) cages in spinal fusion have failed to report adequately on patient-centred clinical outcome measures. Also comparison of PLDLLA cage with a traditionally applicable counterpart has not been previously reported. This is the first randomized prospective study that assesses clinical outcome of PLDLLA cage compared with a poly-ether-ether-ketone (PEEK) implant. Twenty-six patients were randomly assigned to undergo instrumented posterior lumbar interbody fusion (PLIF) whereby either a PEEK cage or a PLDLLA cage was implanted. Clinical outcome based on visual analogue scale scores for leg pain and back pain, as well as Oswestry Disability Index (ODI) and SF-36 questionnaires were documented and analysed. When compared with preoperative values, all clinical parameters have significantly improved in the PEEK group at 2 years after surgery with the exception of SF-36 general health, SF-36 mental health and SF-36 role emotional scores. No clinical parameter showed significant improvement at 2 years after surgery compared with preoperative values in the PLDLLA patient group. Only six patients (50%) in the PLDLLA group showed improvement in the VAS scores for leg and back pain as well as the ODI, as opposed to 10 patients (71%) in the PEEK group. One-third of the patients in the PLDLLA group actually reported worsening of their pain scores and ODI. Three cases of mild to moderate osteolysis were seen in the PLDLLA group. Following up on our preliminary report, these 2-year results confirm the superiority of the PEEK implant to the resorbable PLDLLA implant in aiding spinal fusion and alleviating symptoms following PLIF in patients with degenerative spondylolisthesis associated with either canal stenosis or foramen stenosis or both and emanating from a single lumbar segment.
- 1 February 2009
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (3) , 233-237
Posterior Lumbar Interbody Fusion Using Nonresorbable Poly-Ether-Ether-Ketone Versus Resorbable Poly-l-Lactide-Co-d,l-Lactide Fusion Devices
A prospective randomized clinical study. OBJECTIVE.: To assess fusion, clinical outcome, and complications. Resorbable poly-L- lactide-co-D,L-lactide (PLDLLA) cages intended to aid spinal interbody fusion have been introduced into clinical practice within the last decade. Although early case series show promising results with respect to fusion rate, worries persist with regards to efficacy and potential risks of early failure of these implants. Despite widespread clinical application this is the first randomized prospective study to assess clinical and radiologic outcomes of PLDLLA cage compared with a traditionally applicable counterpart. Twenty-six patients were randomly assigned to undergo instrumented posterior lumbar interbody fusion whereby either a nonresorbable poly-ether-ether-ketone (PEEK) cage or a resorbable PLDLLA cage was implanted to aid fusion. Fusion rate, subsidence, and clinical outcome based on visual analog scale scores for leg pain and back pain, as well as Oswestry Disability Index and SF-36 questionnaires were documented and analyzed. Complications and adverse events were recorded. Fusion rate was significantly higher with the PEEK cage compared with PLDLLA cage (Fisher exact test, P = 0.0302). Rate of subsidence was significantly higher with the PLDLLA cage compared to PEEK cage (Fisher exact test, P = 0.0414). The PEEK group demonstrated greater improvement in the Oswestry Disability Index compared with the PLDLLA group (Fisher exact test, P = 0.1414). Two cases of mild to moderate osteolysis were seen in the PLDLLA group. Our results strongly suggest that PLDLLA cage proffers a lower rate of fusion compared with PEEK cage, and also confirms that the efficacy of PLDLLA cage in enhancing interbody spinal fusion is yet to be established. The higher rate of subsidence and occurrence of osteolysis seen in association with PLDLLA cages in this study remain worrisome.
- 1 February 2009
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (3) , 233-237
Posterior Lumbar Interbody Fusion Using Nonresorbable Poly-Ether-Ether-Ketone Versus Resorbable Poly-l-Lactide-Co-d,l-Lactide Fusion Devices
A prospective randomized clinical study. OBJECTIVE.: To assess fusion, clinical outcome, and complications. Resorbable poly-L- lactide-co-D,L-lactide (PLDLLA) cages intended to aid spinal interbody fusion have been introduced into clinical practice within the last decade. Although early case series show promising results with respect to fusion rate, worries persist with regards to efficacy and potential risks of early failure of these implants. Despite widespread clinical application this is the first randomized prospective study to assess clinical and radiologic outcomes of PLDLLA cage compared with a traditionally applicable counterpart. Twenty-six patients were randomly assigned to undergo instrumented posterior lumbar interbody fusion whereby either a nonresorbable poly-ether-ether-ketone (PEEK) cage or a resorbable PLDLLA cage was implanted to aid fusion. Fusion rate, subsidence, and clinical outcome based on visual analog scale scores for leg pain and back pain, as well as Oswestry Disability Index and SF-36 questionnaires were documented and analyzed. Complications and adverse events were recorded. Fusion rate was significantly higher with the PEEK cage compared with PLDLLA cage (Fisher exact test, P = 0.0302). Rate of subsidence was significantly higher with the PLDLLA cage compared to PEEK cage (Fisher exact test, P = 0.0414). The PEEK group demonstrated greater improvement in the Oswestry Disability Index compared with the PLDLLA group (Fisher exact test, P = 0.1414). Two cases of mild to moderate osteolysis were seen in the PLDLLA group. Our results strongly suggest that PLDLLA cage proffers a lower rate of fusion compared with PEEK cage, and also confirms that the efficacy of PLDLLA cage in enhancing interbody spinal fusion is yet to be established. The higher rate of subsidence and occurrence of osteolysis seen in association with PLDLLA cages in this study remain worrisome.
- 1 October 2006
- Published by Springer Nature in European Journal of Trauma
- Vol. 32 (5) , 477-479
Diaphyseal Femur Fracture in Pycnodysostosis Treated with Pennig Wrist External Fixator: a Case Study
- 1 October 2006
- Published by Springer Nature in European Journal of Trauma
- Vol. 32 (5) , 477-479
Diaphyseal Femur Fracture in Pycnodysostosis Treated with Pennig Wrist External Fixator: a Case Study