Wade Chien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wade Chien has a total of 411 co-authors. Here are the top co-authors by number of shared publications:
John J. Rosowski
Department of Otolaryngology, Massachusetts Eye & Ear Infirmary, Boston, USA
5 shared publicationsSaumil N. Merchant
Department of Otolaryngology, Massachusetts Eye & Ear Infirmary, Boston, USA
5 shared publicationsMichael E. Ravicz
Department of Otolaryngology, Eaton-Peabody Laboratory, Massachusetts Eye & Ear Infirmary, 243 Charles Street, Boston, MA 02114, USA
3 shared publicationsA. Richardson Mark
1 shared publication- Albert L. Merati
University of Washington Medical Center
1 shared publication Aldo Cassol Stamm
1 shared publication
Latest Publications
- 1 January 2010
- Published by Elsevier
Contributors
- 15 August 2009
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 10 (4) , 485-496
Anatomy of the Distal Incus in Humans
The anatomy of the distal incus, including the lenticular process, was examined in histological sections from 270 normal cadaveric human temporal bones aged between less than 1 month and 100 years. All but nine of these sectioned specimens showed signs of a bony connection between the long process of the incus and the flattened plate of the lenticular process, and in 108 specimens a complete bony attachment was observed in a single 20 μm section. In these 108 ears, the bony lenticular process consisted of a proximal narrow “pedicle” connected to a distal flattened “plate” that forms the incudal component of the incudo-stapedial joint. A fibrous joint capsule extended from the stapes head to the pedicle of the lenticular process on all sides, where it was considerably thickened. Three-dimensional reconstructions made from serial 20 μm sections of four bones provided views from all directions that easily convey the anatomical features of this region. Morphometric measurements of the bony architecture of the distal incus in 103 temporal bones were made, including lengths and cross-sectional areas, estimates of the percentage of lacunae containing osteocytes, and the degree of bone resorption. These measurements, analyzed as a function of age, provided an anatomic description over a large age range that can serve as a normal baseline against which structural pathology can be compared. Although none of the bony dimensions showed significant age dependence, the estimated percentage of bony lacunae that contain osteocytes decreased significantly with age. The results have implications for the roles of specific components on the coupling of ossicular motion across the incudo-stapedial joint, and provide insights regarding bone resorption at the level of the distal incus, which occurs clinically in some patients with chronic otitis media or after stapedectomy.
- 15 August 2009
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 10 (4) , 485-496
Anatomy of the Distal Incus in Humans
The anatomy of the distal incus, including the lenticular process, was examined in histological sections from 270 normal cadaveric human temporal bones aged between less than 1 month and 100 years. All but nine of these sectioned specimens showed signs of a bony connection between the long process of the incus and the flattened plate of the lenticular process, and in 108 specimens a complete bony attachment was observed in a single 20 μm section. In these 108 ears, the bony lenticular process consisted of a proximal narrow “pedicle” connected to a distal flattened “plate” that forms the incudal component of the incudo-stapedial joint. A fibrous joint capsule extended from the stapes head to the pedicle of the lenticular process on all sides, where it was considerably thickened. Three-dimensional reconstructions made from serial 20 μm sections of four bones provided views from all directions that easily convey the anatomical features of this region. Morphometric measurements of the bony architecture of the distal incus in 103 temporal bones were made, including lengths and cross-sectional areas, estimates of the percentage of lacunae containing osteocytes, and the degree of bone resorption. These measurements, analyzed as a function of age, provided an anatomic description over a large age range that can serve as a normal baseline against which structural pathology can be compared. Although none of the bony dimensions showed significant age dependence, the estimated percentage of bony lacunae that contain osteocytes decreased significantly with age. The results have implications for the roles of specific components on the coupling of ossicular motion across the incudo-stapedial joint, and provide insights regarding bone resorption at the level of the distal incus, which occurs clinically in some patients with chronic otitis media or after stapedectomy.
- 1 March 2009
- Published by Elsevier in Hearing Research
- Vol. 249 (1-2) , 54-61
Measurements of stapes velocity in live human ears
- 1 March 2009
- Published by Elsevier in Hearing Research
- Vol. 249 (1-2) , 54-61
Measurements of stapes velocity in live human ears
- 26 November 2007
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 122 (9) , 898-904
Isolated fracture of the manubrium of the malleus
Objective: To describe a series of five patients with isolated fracture of the manubrium of the malleus.Design: Retrospective case series.Subjects: Five patients aged 44–64 years with isolated fracture of the manubrium who presented to our institution over a five-year period (2000–2005).Results: All patients presented with a history of digitally manipulating the external auditory canal, leading to the manubrial fracture, which we presume was due to a suction-type mechanism. Otomicroscopy often revealed a break in the smooth contour of the manubrium. All patients had air–bone gaps on audiometry, especially at higher frequencies. Tympanometry showed hypermobility of the tympanic membrane in four patients who were tested. Laser-Doppler vibrometry revealed increased umbo velocity in four out of five patients. Four patients were treated conservatively. One patient underwent exploratory tympanotomy with successful ossiculoplasty.Conclusions: Isolated fracture of the manubrium is a rare condition which may present as sudden-onset hearing loss after digital manipulation of the external auditory canal. The diagnosis can be made on the basis of otomicroscopy, audiometry, tympanometry and laser-Doppler vibrometry. Conservative treatment is often successful.
- 26 November 2007
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 122 (9) , 898-904
Isolated fracture of the manubrium of the malleus
Objective: To describe a series of five patients with isolated fracture of the manubrium of the malleus.Design: Retrospective case series.Subjects: Five patients aged 44–64 years with isolated fracture of the manubrium who presented to our institution over a five-year period (2000–2005).Results: All patients presented with a history of digitally manipulating the external auditory canal, leading to the manubrial fracture, which we presume was due to a suction-type mechanism. Otomicroscopy often revealed a break in the smooth contour of the manubrium. All patients had air–bone gaps on audiometry, especially at higher frequencies. Tympanometry showed hypermobility of the tympanic membrane in four patients who were tested. Laser-Doppler vibrometry revealed increased umbo velocity in four out of five patients. Four patients were treated conservatively. One patient underwent exploratory tympanotomy with successful ossiculoplasty.Conclusions: Isolated fracture of the manubrium is a rare condition which may present as sudden-onset hearing loss after digital manipulation of the external auditory canal. The diagnosis can be made on the basis of otomicroscopy, audiometry, tympanometry and laser-Doppler vibrometry. Conservative treatment is often successful.
- 1 September 2007
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 28 (6) , 782-787
Investigation of the Mechanics of Type III Stapes Columella Tympanoplasty Using Laser-Doppler Vibrometry
Objectives: To investigate the middle ear mechanics of Type III stapes columella tympanoplasty using laser-Doppler vibrometry (LDV) and to determine whether LDV was useful in the identification of structural factors responsible for poor hearing outcomes. Background: The Type III stapes columella tympanoplasty procedure involves placing a tympanic membrane (TM) graft directly onto the stapes head. Postoperative hearing results vary widely, with air-bone gaps (ABGs) ranging from 10 to 60 dB. Methods: Laser-Doppler vibrometry measurements were performed in 22 patients (23 ears) who underwent Type III stapes columella tympanoplasty. The measurements were made at three locations on the TM graft: over the stapes head, over the round window, and on the anterior TM. The LDV results were correlated with the clinical and audiologic findings. Results: The 23 ears were divided into three groups: Nonaerated ears (n = 2). The ABGs were 30 to 60 dB. The TM velocities over all three locations were 20 to 40 dB lower than normal umbo velocity (in normally hearing subjects). Fixed stapes with aerated middle ear (n = 2). The ABGs were 40 to 60 dB, and TM velocities were equivalent to normal umbo velocity in one case and lower by 15 to 20 dB in another case. Mobile stapes and aerated middle ear (n = 19). There were two subgroups in this category: 1) small ABGs less than 25 dB (n = 7) and large gaps greater than or equal to 25 dB (n = 12). There were small differences in TM graft velocity at all three measurement locations between these two subgroups. However, these small differences did not explain the large difference in ABG between the two subgroups. Conclusion: Nonaeration of the middle ear and stapes fixation lead to large residual conductive hearing losses after Type III tympanoplasty. Laser-Doppler vibrometry can aid in the diagnosis of nonaeration of the middle ear but does not readily diagnose stapes fixation. Postoperative results can vary even in cases of a mobile stapes and an aerated middle ear. We hypothesize that these variations may be the result of differences in the coupling between the TM graft and the stapes head. Measurements of TM velocities by means of LDV did not show clear differences between cases with good hearing and cases with poor hearing in ears with a mobile stapes and an aerated ear. Except for diagnosis of nonaeration of the middle ear, LDV seems to have limited clinical usefulness to identify causes of failure after Type III tympanoplasty.
- 1 September 2007
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 28 (6) , 782-787
Investigation of the Mechanics of Type III Stapes Columella Tympanoplasty Using Laser-Doppler Vibrometry
Objectives: To investigate the middle ear mechanics of Type III stapes columella tympanoplasty using laser-Doppler vibrometry (LDV) and to determine whether LDV was useful in the identification of structural factors responsible for poor hearing outcomes. Background: The Type III stapes columella tympanoplasty procedure involves placing a tympanic membrane (TM) graft directly onto the stapes head. Postoperative hearing results vary widely, with air-bone gaps (ABGs) ranging from 10 to 60 dB. Methods: Laser-Doppler vibrometry measurements were performed in 22 patients (23 ears) who underwent Type III stapes columella tympanoplasty. The measurements were made at three locations on the TM graft: over the stapes head, over the round window, and on the anterior TM. The LDV results were correlated with the clinical and audiologic findings. Results: The 23 ears were divided into three groups: Nonaerated ears (n = 2). The ABGs were 30 to 60 dB. The TM velocities over all three locations were 20 to 40 dB lower than normal umbo velocity (in normally hearing subjects). Fixed stapes with aerated middle ear (n = 2). The ABGs were 40 to 60 dB, and TM velocities were equivalent to normal umbo velocity in one case and lower by 15 to 20 dB in another case. Mobile stapes and aerated middle ear (n = 19). There were two subgroups in this category: 1) small ABGs less than 25 dB (n = 7) and large gaps greater than or equal to 25 dB (n = 12). There were small differences in TM graft velocity at all three measurement locations between these two subgroups. However, these small differences did not explain the large difference in ABG between the two subgroups. Conclusion: Nonaeration of the middle ear and stapes fixation lead to large residual conductive hearing losses after Type III tympanoplasty. Laser-Doppler vibrometry can aid in the diagnosis of nonaeration of the middle ear but does not readily diagnose stapes fixation. Postoperative results can vary even in cases of a mobile stapes and an aerated middle ear. We hypothesize that these variations may be the result of differences in the coupling between the TM graft and the stapes head. Measurements of TM velocities by means of LDV did not show clear differences between cases with good hearing and cases with poor hearing in ears with a mobile stapes and an aerated ear. Except for diagnosis of nonaeration of the middle ear, LDV seems to have limited clinical usefulness to identify causes of failure after Type III tympanoplasty.
- 1 February 2007
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 28 (2) , 250-257
Measurements of Human Middle- and Inner-Ear Mechanics With Dehiscence of the Superior Semicircular Canal
Objectives: (1) To develop a cadaveric temporal-bone preparation to study the mechanism of hearing loss resulting from superior semicircular canal dehiscence (SCD) and (2) to assess the potential usefulness of clinical measurements of umbo velocity for the diagnosis of SCD. Background: The syndrome of dehiscence of the superior semicircular canal is a clinical condition encompassing a variety of vestibular and auditory symptoms, including an air-bone gap at low frequencies. It has been hypothesized that the dehiscence acts as a "third window" into the inner ear that shunts acoustic energy away from the cochlea at low frequencies, causing hearing loss. Methods: Sound-induced stapes, umbo, and round-window velocities were measured in prepared temporal bones (n = 8) using laser-Doppler vibrometry (1) with the superior semicircular canal intact, (2) after creation of a dehiscence in the superior canal, and (3) with the dehiscence patched. Clinical measurements of umbo velocity in live SCD ears (n = 29) were compared with similar data from our cadaveric temporal-bone preparations. Results: An SCD caused a significant reduction in sound-induced round-window velocity at low frequencies, small but significant increases in sound-induced stapes and umbo velocities, and a measurable fluid velocity inside the dehiscence. The increase in sound-induced umbo velocity in temporal bones was also found to be similar to that measured in the 29 live ears with SCD. Conclusion: Findings from the cadaveric temporal-bone preparation were consistent with the third-window hypothesis. In addition, measurement of umbo velocity in live ears is helpful in distinguishing SCD from other otologic pathologies presenting with an air-bone gap (e.g., otosclerosis).
- 1 February 2007
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 28 (2) , 250-257
Measurements of Human Middle- and Inner-Ear Mechanics With Dehiscence of the Superior Semicircular Canal
Objectives: (1) To develop a cadaveric temporal-bone preparation to study the mechanism of hearing loss resulting from superior semicircular canal dehiscence (SCD) and (2) to assess the potential usefulness of clinical measurements of umbo velocity for the diagnosis of SCD. Background: The syndrome of dehiscence of the superior semicircular canal is a clinical condition encompassing a variety of vestibular and auditory symptoms, including an air-bone gap at low frequencies. It has been hypothesized that the dehiscence acts as a "third window" into the inner ear that shunts acoustic energy away from the cochlea at low frequencies, causing hearing loss. Methods: Sound-induced stapes, umbo, and round-window velocities were measured in prepared temporal bones (n = 8) using laser-Doppler vibrometry (1) with the superior semicircular canal intact, (2) after creation of a dehiscence in the superior canal, and (3) with the dehiscence patched. Clinical measurements of umbo velocity in live SCD ears (n = 29) were compared with similar data from our cadaveric temporal-bone preparations. Results: An SCD caused a significant reduction in sound-induced round-window velocity at low frequencies, small but significant increases in sound-induced stapes and umbo velocities, and a measurable fluid velocity inside the dehiscence. The increase in sound-induced umbo velocity in temporal bones was also found to be similar to that measured in the 29 live ears with SCD. Conclusion: Findings from the cadaveric temporal-bone preparation were consistent with the third-window hypothesis. In addition, measurement of umbo velocity in live ears is helpful in distinguishing SCD from other otologic pathologies presenting with an air-bone gap (e.g., otosclerosis).
- 1 December 2006
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 70 (12) , 2073-2079
Type 1 laryngeal cleft: Establishing a functional diagnostic and management algorithm
- 1 December 2006
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 70 (12) , 2073-2079
Type 1 laryngeal cleft: Establishing a functional diagnostic and management algorithm
- Open Access
- 1 April 2006
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 11 (3) , 183-197
The Effect of Methodological Differences in the Measurement of Stapes Motion in Live and Cadaver Ears
Methodological differences in sound-induced stapes velocity (Vs) measurements in live and cadaveric ears were examined using fresh cadaveric temporal bones. On average, differences in preparation (sectioning the stapedius tendon, removing the facial nerve, and widely opening the facial recess) had statistically insignificant effects on measured Vs. Differences in the achievable measurement angle (with respect to the axis of piston-like stapes motion) had a significant effect on measured Vs below 2 kHz. These results suggest that much if not all of the differences in Vs measurements between live and cadaveric ears can be explained by the differences in measurement angle between the two preparations. Measurement angle was found to have minimal effect on measured Vs above 2 kHz. This demonstrates that the commonly used method of estimating stapes translational velocity by dividing the measured velocity by the cosine of the measurement angle is not valid above 2 kHz.
- 1 April 2006
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 11 (3) , 183-197
Open AccessThe Effect of Methodological Differences in the Measurement of Stapes Motion in Live and Cadaver Ears
Methodological differences in sound-induced stapes velocity (Vs) measurements in live and cadaveric ears were examined using fresh cadaveric temporal bones. On average, differences in preparation (sectioning the stapedius tendon, removing the facial nerve, and widely opening the facial recess) had statistically insignificant effects on measured Vs. Differences in the achievable measurement angle (with respect to the axis of piston-like stapes motion) had a significant effect on measured Vs below 2 kHz. These results suggest that much if not all of the differences in Vs measurements between live and cadaveric ears can be explained by the differences in measurement angle between the two preparations. Measurement angle was found to have minimal effect on measured Vs above 2 kHz. This demonstrates that the commonly used method of estimating stapes translational velocity by dividing the measured velocity by the cosine of the measurement angle is not valid above 2 kHz.