Giulio Gambarota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giulio Gambarota has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Robert V. Mulkern
Department of Radiology, Children’s Hospital, Harvard Medical School, Boston, MA, USA
3 shared publicationsGunnar Krueger
Laboratory for Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
2 shared publicationsHervé Saint‐Jalmes
INSERM, UMR 1099, Rennes, France
2 shared publicationsMark Tanner
GlaxoSmithKline, Clinical Imaging Center, Imperial College, London, UK
2 shared publicationsRalf Mekle
Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, Station 6, Lausanne CH 1015, Switzerland
2 shared publications- Raphaël Guillin
CHU de Rennes (Service d’imagerie Médicale), Rennes, France
2 shared publications
Latest Publications
- Open Access
- 3 May 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (9) , 592-600
Fluid and White Matter Suppression
Objective: Cortical lesions are common in multiple sclerosis (MS), but their visualization is challenging on conventional magnetic resonance imaging. The uniform image derived from magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGEuni) detects cortical lesions with a similar rate as the criterion standard sequence, double inversion recovery. Fluid and white matter suppression (FLAWS) provides multiple reconstructed contrasts acquired during a single acquisition. These contrasts include FLAWS minimum image (FLAWSmin), which provides an exquisite sensitivity to the gray matter signal and therefore may facilitate cortical lesion identification, as well as high contrast FLAWS (FLAWShco), which gives a contrast that is similar to one of MP2RAGEuni. In this study, we compared the manual detection rate of cortical lesions on MP2RAGEuni, FLAWSmin, and FLAWShco in MS patients. Furthermore, we assessed whether the combined detection rate on FLAWSmin and FLAWShco was superior to MP2RAGEuni for cortical lesions identification. Last, we compared quantitative T1 maps (qT1) provided by both MP2RAGE and FLAWS in MS lesions. Materials and Methods: We included 30 relapsing-remitting MS patients who underwent MP2RAGE and FLAWS magnetic resonance imaging with isotropic spatial resolution of 1 mm at 3 T. Cortical lesions were manually segmented by consensus of 3 trained raters and classified as intracortical or leukocortical lesions on (1) MP2RAGE uniform/flat images, (2) FLAWSmin, and (3) FLAWShco. In addition, segmented lesions on FLAWSmin and FLAWShco were merged to produce a union lesion map (FLAWSmin + hco). Number and volume of all cortical, intracortical, and leukocortical lesions were compared among MP2RAGEuni, FLAWSmin, and FLAWShco using Friedman test and between MP2RAGEuni and FLAWSmin + hco using Wilcoxon signed rank test. The FLAWS T1 maps were then compared with the reference MP2RAGE T1 maps using relative differences in percentage. In an exploratory analysis, individual cortical lesion counts of the 3 raters were compared, and interrater variability was quantified using Fleiss ϰ. Results: In total, 633 segmentations were made on the 3 contrasts, corresponding to 355 cortical lesions. The median number and volume of single cortical, intracortical, and leukocortical lesions were comparable among MP2RAGEuni, FLAWSmin, and FLAWShco. In patients with cortical lesions (22/30), median cumulative lesion volume was larger on FLAWSmin (587 μL; IQR, 1405 μL) than on MP2RAGEuni (490 μL; IQR, 990 μL; P = 0.04), whereas there was no difference between FLAWSmin and FLAWShco, or FLAWShco and MP2RAGEuni. FLAWSmin + hco showed significantly greater numbers of cortical (median, 4.5; IQR, 15) and leukocortical (median, 3.5; IQR, 12) lesions than MP2RAGEuni (median, 3; IQR, 10; median, 2.5; IQR, 7; both P < 0.001). Interrater agreement was moderate on MP2RAGEuni (ϰ = 0.582) and FLAWShco (ϰ = 0.584), but substantial on FLAWSmin (ϰ = 0.614). qT1 in lesions was similar between MP2RAGE and FLAWS. Conclusions: Cortical lesions identification in FLAWSmin and FLAWShco was comparable to MP2RAGEuni. The combination of FLAWSmin and FLAWShco allowed to identify a higher number of cortical lesions than MP2RAGEuni, whereas qT1 maps did not differ between the 2 acquisition schemes.
- 3 May 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (9) , 592-600
Open AccessFluid and White Matter Suppression
Objective: Cortical lesions are common in multiple sclerosis (MS), but their visualization is challenging on conventional magnetic resonance imaging. The uniform image derived from magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGEuni) detects cortical lesions with a similar rate as the criterion standard sequence, double inversion recovery. Fluid and white matter suppression (FLAWS) provides multiple reconstructed contrasts acquired during a single acquisition. These contrasts include FLAWS minimum image (FLAWSmin), which provides an exquisite sensitivity to the gray matter signal and therefore may facilitate cortical lesion identification, as well as high contrast FLAWS (FLAWShco), which gives a contrast that is similar to one of MP2RAGEuni. In this study, we compared the manual detection rate of cortical lesions on MP2RAGEuni, FLAWSmin, and FLAWShco in MS patients. Furthermore, we assessed whether the combined detection rate on FLAWSmin and FLAWShco was superior to MP2RAGEuni for cortical lesions identification. Last, we compared quantitative T1 maps (qT1) provided by both MP2RAGE and FLAWS in MS lesions. Materials and Methods: We included 30 relapsing-remitting MS patients who underwent MP2RAGE and FLAWS magnetic resonance imaging with isotropic spatial resolution of 1 mm at 3 T. Cortical lesions were manually segmented by consensus of 3 trained raters and classified as intracortical or leukocortical lesions on (1) MP2RAGE uniform/flat images, (2) FLAWSmin, and (3) FLAWShco. In addition, segmented lesions on FLAWSmin and FLAWShco were merged to produce a union lesion map (FLAWSmin + hco). Number and volume of all cortical, intracortical, and leukocortical lesions were compared among MP2RAGEuni, FLAWSmin, and FLAWShco using Friedman test and between MP2RAGEuni and FLAWSmin + hco using Wilcoxon signed rank test. The FLAWS T1 maps were then compared with the reference MP2RAGE T1 maps using relative differences in percentage. In an exploratory analysis, individual cortical lesion counts of the 3 raters were compared, and interrater variability was quantified using Fleiss ϰ. Results: In total, 633 segmentations were made on the 3 contrasts, corresponding to 355 cortical lesions. The median number and volume of single cortical, intracortical, and leukocortical lesions were comparable among MP2RAGEuni, FLAWSmin, and FLAWShco. In patients with cortical lesions (22/30), median cumulative lesion volume was larger on FLAWSmin (587 μL; IQR, 1405 μL) than on MP2RAGEuni (490 μL; IQR, 990 μL; P = 0.04), whereas there was no difference between FLAWSmin and FLAWShco, or FLAWShco and MP2RAGEuni. FLAWSmin + hco showed significantly greater numbers of cortical (median, 4.5; IQR, 15) and leukocortical (median, 3.5; IQR, 12) lesions than MP2RAGEuni (median, 3; IQR, 10; median, 2.5; IQR, 7; both P < 0.001). Interrater agreement was moderate on MP2RAGEuni (ϰ = 0.582) and FLAWShco (ϰ = 0.584), but substantial on FLAWSmin (ϰ = 0.614). qT1 in lesions was similar between MP2RAGE and FLAWS. Conclusions: Cortical lesions identification in FLAWSmin and FLAWShco was comparable to MP2RAGEuni. The combination of FLAWSmin and FLAWShco allowed to identify a higher number of cortical lesions than MP2RAGEuni, whereas qT1 maps did not differ between the 2 acquisition schemes.
- 27 November 2017
- Published by Wiley in Medical Physics
- Vol. 45 (1) , 250-257
Virtual phantom magnetic resonance imaging (ViP MRI) on a clinical MRI platform
The purpose of this study was to implement Virtual Phantom Magnetic Resonance Imaging (ViP MRI), a technique that allows for generating reference signals in MR images using radiofrequency (RF) signals, on a clinical MR system and to test newly designed virtual phantoms. MRI experiments were conducted on a 1.5 T MRI scanner. Electromagnetic modelling of the ViP system was done using the principle of reciprocity. The ViP RF signals were generated using a compact waveform generator (dimensions of 26 cm × 18 cm × 16 cm), connected to a homebuilt 25 mm-diameter RF coil. The ViP RF signals were transmitted to the MRI scanner bore, simultaneously with the acquisition of the signal from the object of interest. Different types of MRI data acquisition (2D and 3D gradient-echo) as well as different phantoms, including the Shepp–Logan phantom, were tested. Furthermore, a uniquely designed virtual phantom — in the shape of a grid — was generated; this newly proposed phantom allows for the investigations of the vendor distortion correction field. High quality MR images of virtual phantoms were obtained. An excellent agreement was found between the experimental data and the inverse cube law, which was the expected functional dependence obtained from the electromagnetic modelling of the ViP system. Short-term time stability measurements yielded a coefficient of variation in the signal intensity over time equal to 0.23% and 0.13% for virtual and physical phantom, respectively. MR images of the virtual grid-shaped phantom were reconstructed with the vendor distortion correction; this allowed for a direct visualization of the vendor distortion correction field. Furthermore, as expected from the electromagnetic modelling of the ViP system, a very compact coil (diameter ~ cm) and very small currents (intensity ~ mA) were sufficient to generate a signal comparable to that of physical phantoms in MRI experiments. The ViP MRI technique was successfully implemented on a clinical MR system. One of the major advantages of ViP MRI over previous approaches is that the generation and transmission of RF signals can be achieved with a self-contained apparatus. As such, the ViP MRI technique is transposable to different platforms (preclinical and clinical) of different vendors. It is also shown here that ViP MRI could be used to generate signals whose characteristics cannot be reproduced by physical objects. This could be exploited to assess MRI system properties, such as the vendor distortion correction field.
- 27 November 2017
- Published by Wiley in Medical Physics
- Vol. 45 (1) , 250-257
Virtual phantom magnetic resonance imaging (ViP MRI) on a clinical MRI platform
The purpose of this study was to implement Virtual Phantom Magnetic Resonance Imaging (ViP MRI), a technique that allows for generating reference signals in MR images using radiofrequency (RF) signals, on a clinical MR system and to test newly designed virtual phantoms. MRI experiments were conducted on a 1.5 T MRI scanner. Electromagnetic modelling of the ViP system was done using the principle of reciprocity. The ViP RF signals were generated using a compact waveform generator (dimensions of 26 cm × 18 cm × 16 cm), connected to a homebuilt 25 mm-diameter RF coil. The ViP RF signals were transmitted to the MRI scanner bore, simultaneously with the acquisition of the signal from the object of interest. Different types of MRI data acquisition (2D and 3D gradient-echo) as well as different phantoms, including the Shepp–Logan phantom, were tested. Furthermore, a uniquely designed virtual phantom — in the shape of a grid — was generated; this newly proposed phantom allows for the investigations of the vendor distortion correction field. High quality MR images of virtual phantoms were obtained. An excellent agreement was found between the experimental data and the inverse cube law, which was the expected functional dependence obtained from the electromagnetic modelling of the ViP system. Short-term time stability measurements yielded a coefficient of variation in the signal intensity over time equal to 0.23% and 0.13% for virtual and physical phantom, respectively. MR images of the virtual grid-shaped phantom were reconstructed with the vendor distortion correction; this allowed for a direct visualization of the vendor distortion correction field. Furthermore, as expected from the electromagnetic modelling of the ViP system, a very compact coil (diameter ~ cm) and very small currents (intensity ~ mA) were sufficient to generate a signal comparable to that of physical phantoms in MRI experiments. The ViP MRI technique was successfully implemented on a clinical MR system. One of the major advantages of ViP MRI over previous approaches is that the generation and transmission of RF signals can be achieved with a self-contained apparatus. As such, the ViP MRI technique is transposable to different platforms (preclinical and clinical) of different vendors. It is also shown here that ViP MRI could be used to generate signals whose characteristics cannot be reproduced by physical objects. This could be exploited to assess MRI system properties, such as the vendor distortion correction field.
- 1 July 2017
- Published by Elsevier in Analytical Biochemistry
- Vol. 529, 65-78
Optimization of metabolite detection by quantum mechanics simulations in magnetic resonance spectroscopy
- 1 July 2017
- Published by Elsevier in Analytical Biochemistry
- Vol. 529, 65-78
Optimization of metabolite detection by quantum mechanics simulations in magnetic resonance spectroscopy
- 1 June 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 39, 157-161
A fast method for the quantification of fat fraction and relaxation times: Comparison of five sites of bone marrow
- 1 June 2017
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 39, 157-161
A fast method for the quantification of fat fraction and relaxation times: Comparison of five sites of bone marrow
- Open Access
- 5 January 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 310-317
Eliminating the blood‐flow confounding effect in intravoxel incoherent motion (IVIM) using the non‐negative least square analysis in liver
Purpose Tissue perfusion measurements using intravoxel incoherent motion (IVIM) diffusion-MRI are of interest for investigations of liver pathologies. A confounding factor in the perfusion quantification is the partial volume between liver tissue and large blood vessels. The aim of this study was to assess and correct for this partial volume effect in the estimation of the perfusion fraction. Methods MRI experiments were performed at 3 Tesla with a diffusion-MRI sequence at 12 b-values. Diffusion signal decays in liver were analyzed using the non-negative least square (NNLS) method and the biexponential fitting approach. Results In some voxels, the NNLS analysis yielded a very fast-decaying component that was assigned to partial volume with the blood flowing in large vessels. Partial volume correction was performed by biexponential curve fitting, where the first data point (b = 0 s/mm2) was eliminated in voxels with a very fast-decaying component. Biexponential fitting with partial volume correction yielded parametric maps with perfusion fraction values smaller than biexponential fitting without partial volume correction. Conclusion The results of the current study indicate that the NNLS analysis in combination with biexponential curve fitting allows to correct for partial volume effects originating from blood flow in IVIM perfusion fraction measurements. Magn Reson Med 77:310–317, 2017.
- 5 January 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 310-317
Open AccessEliminating the blood‐flow confounding effect in intravoxel incoherent motion (IVIM) using the non‐negative least square analysis in liver
Purpose Tissue perfusion measurements using intravoxel incoherent motion (IVIM) diffusion-MRI are of interest for investigations of liver pathologies. A confounding factor in the perfusion quantification is the partial volume between liver tissue and large blood vessels. The aim of this study was to assess and correct for this partial volume effect in the estimation of the perfusion fraction. Methods MRI experiments were performed at 3 Tesla with a diffusion-MRI sequence at 12 b-values. Diffusion signal decays in liver were analyzed using the non-negative least square (NNLS) method and the biexponential fitting approach. Results In some voxels, the NNLS analysis yielded a very fast-decaying component that was assigned to partial volume with the blood flowing in large vessels. Partial volume correction was performed by biexponential curve fitting, where the first data point (b = 0 s/mm2) was eliminated in voxels with a very fast-decaying component. Biexponential fitting with partial volume correction yielded parametric maps with perfusion fraction values smaller than biexponential fitting without partial volume correction. Conclusion The results of the current study indicate that the NNLS analysis in combination with biexponential curve fitting allows to correct for partial volume effects originating from blood flow in IVIM perfusion fraction measurements. Magn Reson Med 77:310–317, 2017.
- Open Access
- 1 November 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (9) , 1091-1096
MRI quantification of diffusion and perfusion in bone marrow by intravoxel incoherent motion (IVIM) and non-negative least square (NNLS) analysis
- 1 November 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (9) , 1091-1096
Open AccessMRI quantification of diffusion and perfusion in bone marrow by intravoxel incoherent motion (IVIM) and non-negative least square (NNLS) analysis
- 7 January 2013
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 228, 76-80
Selective spectral modulation of strongly coupled spins with an echo top refocusing pulse in PRESS sequences
- 7 January 2013
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 228, 76-80
Selective spectral modulation of strongly coupled spins with an echo top refocusing pulse in PRESS sequences
- 2 June 2012
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 43 (3) , 451-457
An NMR Phantom Mimicking Intramyocellular (IMCL) and Extramyocellular Lipids (EMCL)
- 2 June 2012
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 43 (3) , 451-457
An NMR Phantom Mimicking Intramyocellular (IMCL) and Extramyocellular Lipids (EMCL)
- Open Access
- 14 December 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 35 (5) , 1063-1070
Fluid and white matter suppression with the MP2RAGE sequence
Purpose: To develop a magnetic resonance imaging (MRI) sequence (fluid and white matter suppression, FLAWS) for generating two sets of images from a single acquisition: one with contrast similar to a T1‐weighted magnetization‐prepared rapid gradient‐echo sequence (MPRAGE) for structural definition; the other with nulled white matter (WM) signal intensity, similar to the fast gray matter T1 inversion recovery (FGATIR) sequence, for improved delineation of subcortical brain structures.Materials and Methods: The recently proposed MP2RAGE, which is a modification of the MPRAGE and generates two image sets at different inversion times, was employed to generate the FGATIR‐like contrast (FLAWS1) and MPRAGE‐like contrast (FLAWS2). Five healthy volunteers were scanned at 3T and brain tissue contrast and contrast‐to‐noise were compared.Results: FLAWS1 and FLAWS2 exhibited similar tissue contrast and contrast‐to‐noise as the “reference” sequences, FGATIR and MPRAGE, respectively. Synthetic minimum value images generated from FLAWS1 and FLAWS2 provided a gray matter‐dominant image.Conclusion: FLAWS provides two coregistered 3D volumes, one with nulled WM signal intensity and another with nulled cerebrospinal fluid. The coregistered nature of the two datasets allows for generating images that might be helpful in segmentation algorithms and clinical diagnosis. J. Magn. Reson. Imaging 2012;35:1063‐1070.
- 14 December 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 35 (5) , 1063-1070
Open AccessFluid and white matter suppression with the MP2RAGE sequence
Purpose: To develop a magnetic resonance imaging (MRI) sequence (fluid and white matter suppression, FLAWS) for generating two sets of images from a single acquisition: one with contrast similar to a T1‐weighted magnetization‐prepared rapid gradient‐echo sequence (MPRAGE) for structural definition; the other with nulled white matter (WM) signal intensity, similar to the fast gray matter T1 inversion recovery (FGATIR) sequence, for improved delineation of subcortical brain structures.Materials and Methods: The recently proposed MP2RAGE, which is a modification of the MPRAGE and generates two image sets at different inversion times, was employed to generate the FGATIR‐like contrast (FLAWS1) and MPRAGE‐like contrast (FLAWS2). Five healthy volunteers were scanned at 3T and brain tissue contrast and contrast‐to‐noise were compared.Results: FLAWS1 and FLAWS2 exhibited similar tissue contrast and contrast‐to‐noise as the “reference” sequences, FGATIR and MPRAGE, respectively. Synthetic minimum value images generated from FLAWS1 and FLAWS2 provided a gray matter‐dominant image.Conclusion: FLAWS provides two coregistered 3D volumes, one with nulled WM signal intensity and another with nulled cerebrospinal fluid. The coregistered nature of the two datasets allows for generating images that might be helpful in segmentation algorithms and clinical diagnosis. J. Magn. Reson. Imaging 2012;35:1063‐1070.
- 4 September 2011
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 24 (6) , 339-345
1H−MRS of hepatic fat using short TR at 3T: SNR optimization and fast T2 relaxometry
To increase the signal-to-noise ratio (SNR) efficiency of hepatic fat signals in proton magnetic resonance spectroscopy (1H MRS) at 3 T, in order to improve the quantitation of hepatic fat and allow fast, single breath-hold T2 relaxometry of hepatic water and fat. Since the T1 of lipid protons is relatively short, we hypothesized that it could be possible to increase the lipid SNR efficiency by choosing a TR shorter than that typically employed (≥1.5 s). The lipid SNR per unit-time was calculated using published values of lipid (CH2)n protons’ T1 at 3 T. 1H MRS PRESS spectra were acquired from VOIs located in the right lobe of the liver in 28 healthy volunteers. At the short TR of 0.6 s, fast T2 relaxometry with the acquisition of 16 echo times (30, 40, ..., 180 ms), was performed in a single breath-hold measurement using a modified PRESS sequence. Good agreement was observed between simulated and experimental data, with the shortening of TR to 0.6 s yielding an ~50% SNR improvement of hepatic lipid (CH2)n resonances, compared to the SNR at TR = 2 s. The T2 relaxation time of water and lipid (CH2)n protons at 3 T was 25.8 ± 1.1 ms and 55.4 ± 3.9 ms, respectively, across five healthy volunteers. The short-TR approach allows for an improved SNR efficiency of lipids and for fast T2 relaxometry of hepatic water and fat, with a detailed coverage of the T2 relaxation decay curve, within a single breath-hold experiment.
- 4 September 2011
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 24 (6) , 339-345
1H−MRS of hepatic fat using short TR at 3T: SNR optimization and fast T2 relaxometry
To increase the signal-to-noise ratio (SNR) efficiency of hepatic fat signals in proton magnetic resonance spectroscopy (1H MRS) at 3 T, in order to improve the quantitation of hepatic fat and allow fast, single breath-hold T2 relaxometry of hepatic water and fat. Since the T1 of lipid protons is relatively short, we hypothesized that it could be possible to increase the lipid SNR efficiency by choosing a TR shorter than that typically employed (≥1.5 s). The lipid SNR per unit-time was calculated using published values of lipid (CH2)n protons’ T1 at 3 T. 1H MRS PRESS spectra were acquired from VOIs located in the right lobe of the liver in 28 healthy volunteers. At the short TR of 0.6 s, fast T2 relaxometry with the acquisition of 16 echo times (30, 40, ..., 180 ms), was performed in a single breath-hold measurement using a modified PRESS sequence. Good agreement was observed between simulated and experimental data, with the shortening of TR to 0.6 s yielding an ~50% SNR improvement of hepatic lipid (CH2)n resonances, compared to the SNR at TR = 2 s. The T2 relaxation time of water and lipid (CH2)n protons at 3 T was 25.8 ± 1.1 ms and 55.4 ± 3.9 ms, respectively, across five healthy volunteers. The short-TR approach allows for an improved SNR efficiency of lipids and for fast T2 relaxometry of hepatic water and fat, with a detailed coverage of the T2 relaxation decay curve, within a single breath-hold experiment.