Daniel M. Rasetshwane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daniel M. Rasetshwane has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Stephen T. Neely
Boys Town National Research Hospital, Omaha, NE, USA
13 shared publications Judy G. Kopun
Center for Hearing Research, Boys Town National Research Hospital , 555 North 30th Street, Omaha, Nebraska 68131, USA
9 shared publicationsMichael P. Gorga
Center for Hearing Research, Boys Town National Research Hospital, Omaha, NE
8 shared publicationsStephen T. Neely
Center for Hearing Research, Boys Town National Research Hospital , 555 North 30th Street, Omaha, Nebraska 68131, USA
4 shared publicationsWalt Jesteadt
Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
2 shared publicationsAndrea C. Trevino
Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131
1 shared publication
Latest Publications
- 1 December 2019
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 146 (6) , 4481-4492
Comparison of distortion-product otoacoustic emission and stimulus-frequency otoacoustic emission two-tone suppression in humans
Distortion-product otoacoustic emission (DPOAE) and stimulus-frequency otoacoustic emission (SFOAE) are two types of acoustic signals emitted by the inner ear in response to tonal stimuli. The levels of both emission types may be reduced by the inclusion of additional (suppressor) tones with the stimulus. Comparison of two-tone suppression properties across emission type addresses a clinically relevant question of whether these two types of emission provide similar information about cochlear status. The purpose of this study was to compare DPOAE suppression to SFOAE suppression from the same ear in a group of participants with normal hearing. Probe frequency was approximately 1000 Hz, and the suppressor frequency varied from −1.5 to 0.5 octaves relative to the probe frequency. DPOAE and SFOAE suppression were compared in terms of (1) suppression growth rate (SGR), (2) superimposed suppression tuning curves (STCs), and (3) STC-derived metrics, such as high-frequency slope, cochlear amplifier gain, and QERB (ERB, equivalent rectangular bandwidth). Below the probe frequency, the SGR was slightly greater than one for SFOAEs and slightly less than two for DPOAEs. There were no differences in STC metrics across emission types. These observations may provide useful constraints on physiology-based models of otoacoustic emission suppression.
- 1 December 2019
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 146 (6) , 4481-4492
Comparison of distortion-product otoacoustic emission and stimulus-frequency otoacoustic emission two-tone suppression in humans
Distortion-product otoacoustic emission (DPOAE) and stimulus-frequency otoacoustic emission (SFOAE) are two types of acoustic signals emitted by the inner ear in response to tonal stimuli. The levels of both emission types may be reduced by the inclusion of additional (suppressor) tones with the stimulus. Comparison of two-tone suppression properties across emission type addresses a clinically relevant question of whether these two types of emission provide similar information about cochlear status. The purpose of this study was to compare DPOAE suppression to SFOAE suppression from the same ear in a group of participants with normal hearing. Probe frequency was approximately 1000 Hz, and the suppressor frequency varied from −1.5 to 0.5 octaves relative to the probe frequency. DPOAE and SFOAE suppression were compared in terms of (1) suppression growth rate (SGR), (2) superimposed suppression tuning curves (STCs), and (3) STC-derived metrics, such as high-frequency slope, cochlear amplifier gain, and QERB (ERB, equivalent rectangular bandwidth). Below the probe frequency, the SGR was slightly greater than one for SFOAEs and slightly less than two for DPOAEs. There were no differences in STC metrics across emission types. These observations may provide useful constraints on physiology-based models of otoacoustic emission suppression.
- 1 January 2019
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 30 (1) , 16-30
Influence of Instantaneous Compression on Recognition of Speech in Noise with Temporal Dips
Background:In listening environments with background noise that fluctuates in level, listeners with normal hearing can “glimpse” speech during dips in the noise, resulting in better speech recognition in fluctuating noise than in steady noise at the same overall level (referred to as masking release). Listeners with sensorineural hearing loss show less masking release. Amplification can improve masking release but not to the same extent that it does for listeners with normal hearing.Purpose:The purpose of this study was to compare masking release for listeners with sensorineural hearing loss obtained with an experimental hearing-aid signal-processing algorithm with instantaneous compression (referred to as a suppression hearing aid, SHA) to masking release obtained with fast compression. The suppression hearing aid mimics effects of normal cochlear suppression, i.e., the reduction in the response to one sound by the simultaneous presentation of another sound.Research Design:A within-participant design with repeated measures across test conditions was used.Study Sample:Participants included 29 adults with mild-to-moderate sensorineural hearing loss and 21 adults with normal hearing.Intervention:Participants with sensorineural hearing loss were fitted with simulators for SHA and a generic hearing aid (GHA) with fast (but not instantaneous) compression (5 ms attack and 50 ms release times) and no suppression. Gain was prescribed using either an experimental method based on categorical loudness scaling (CLS) or the Desired Sensation Level (DSL) algorithm version 5a, resulting in a total of four processing conditions: CLS-GHA, CLS-SHA, DSL-GHA, and DSL-SHA.Data Collection:All participants listened to consonant-vowel-consonant nonwords in the presence of temporally-modulated and steady noise. An adaptive-tracking procedure was used to determine the signal-to-noise ratio required to obtain 29% and 71% correct. Measurements were made with amplification for participants with sensorineural hearing loss and without amplification for participants with normal hearing.Analysis:Repeated-measures analysis of variance was used to determine the influence of within-participant factors of noise type and, for participants with sensorineural hearing loss, processing condition on masking release. Pearson correlational analysis was used to assess the effect of age on masking release for participants with sensorineural hearing loss.Results:Statistically significant masking release was observed for listeners with sensorineural hearing loss for 29% correct, but not for 71% correct. However, the amount of masking release was less than masking release for participants with normal hearing. There were no significant differences among the amplification conditions for participants with sensorineural hearing loss.Conclusions:The results suggest that amplification with either instantaneous or fast compression resulted in similar masking release for listeners with sensorineural hearing loss. However, the masking release was less for participants with hearing loss than it was for those with normal hearing.
- 1 January 2019
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 30 (1) , 16-30
Influence of Instantaneous Compression on Recognition of Speech in Noise with Temporal Dips
Background:In listening environments with background noise that fluctuates in level, listeners with normal hearing can “glimpse” speech during dips in the noise, resulting in better speech recognition in fluctuating noise than in steady noise at the same overall level (referred to as masking release). Listeners with sensorineural hearing loss show less masking release. Amplification can improve masking release but not to the same extent that it does for listeners with normal hearing.Purpose:The purpose of this study was to compare masking release for listeners with sensorineural hearing loss obtained with an experimental hearing-aid signal-processing algorithm with instantaneous compression (referred to as a suppression hearing aid, SHA) to masking release obtained with fast compression. The suppression hearing aid mimics effects of normal cochlear suppression, i.e., the reduction in the response to one sound by the simultaneous presentation of another sound.Research Design:A within-participant design with repeated measures across test conditions was used.Study Sample:Participants included 29 adults with mild-to-moderate sensorineural hearing loss and 21 adults with normal hearing.Intervention:Participants with sensorineural hearing loss were fitted with simulators for SHA and a generic hearing aid (GHA) with fast (but not instantaneous) compression (5 ms attack and 50 ms release times) and no suppression. Gain was prescribed using either an experimental method based on categorical loudness scaling (CLS) or the Desired Sensation Level (DSL) algorithm version 5a, resulting in a total of four processing conditions: CLS-GHA, CLS-SHA, DSL-GHA, and DSL-SHA.Data Collection:All participants listened to consonant-vowel-consonant nonwords in the presence of temporally-modulated and steady noise. An adaptive-tracking procedure was used to determine the signal-to-noise ratio required to obtain 29% and 71% correct. Measurements were made with amplification for participants with sensorineural hearing loss and without amplification for participants with normal hearing.Analysis:Repeated-measures analysis of variance was used to determine the influence of within-participant factors of noise type and, for participants with sensorineural hearing loss, processing condition on masking release. Pearson correlational analysis was used to assess the effect of age on masking release for participants with sensorineural hearing loss.Results:Statistically significant masking release was observed for listeners with sensorineural hearing loss for 29% correct, but not for 71% correct. However, the amount of masking release was less than masking release for participants with normal hearing. There were no significant differences among the amplification conditions for participants with sensorineural hearing loss.Conclusions:The results suggest that amplification with either instantaneous or fast compression resulted in similar masking release for listeners with sensorineural hearing loss. However, the masking release was less for participants with hearing loss than it was for those with normal hearing.
- 1 September 2018
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 39 (5) , 829-844
Using Thresholds in Noise to Identify Hidden Hearing Loss in Humans
Objectives: Recent animal studies suggest that noise-induced synaptopathy may underlie a phenomenon that has been labeled hidden hearing loss (HHL). Noise exposure preferentially damages low spontaneous-rate auditory nerve fibers, which are involved in the processing of moderate- to high-level sounds and are more resistant to masking by background noise. Therefore, the effect of synaptopathy may be more evident in suprathreshold measures of auditory function, especially in the presence of background noise. The purpose of this study was to develop a statistical model for estimating HHL in humans using thresholds in noise as the outcome variable and measures that reflect the integrity of sites along the auditory pathway as explanatory variables. Our working hypothesis is that HHL is evident in the portion of the variance observed in thresholds in noise that is not dependent on thresholds in quiet, because this residual variance retains statistical dependence on other measures of suprathreshold function. Design: Study participants included 13 adults with normal hearing (≤15 dB HL) and 20 adults with normal hearing at 1 kHz and sensorineural hearing loss at 4 kHz (>15 dB HL). Thresholds in noise were measured, and the residual of the correlation between thresholds in noise and thresholds in quiet, which we refer to as thresholds-in-noise residual, was used as the outcome measure for the model. Explanatory measures were as follows: (1) auditory brainstem response (ABR) waves I and V amplitudes; (2) electrocochleographic action potential and summating potential amplitudes; (3) distortion product otoacoustic emissions level; and (4) categorical loudness scaling. All measurements were made at two frequencies (1 and 4 kHz). ABR and electrocochleographic measurements were made at 80 and 100 dB peak equivalent sound pressure level, while wider ranges of levels were tested during distortion product otoacoustic emission and categorical loudness scaling measurements. A model relating the thresholds-in-noise residual and the explanatory measures was created using multiple linear regression analysis. Results: Predictions of thresholds-in-noise residual using the model accounted for 61% (p < 0.01) and 48% (p < 0.01) of the variance in the measured thresholds-in-noise residual at 1 and 4 kHz, respectively. Conclusions: Measures of thresholds in noise, the summating potential to action potential ratio, and ABR waves I and V amplitudes may be useful for the prediction of HHL in humans. With further development, our approach of quantifying HHL by the variance that remains in suprathreshold measures of auditory function after removing the variance due to thresholds in quiet, together with our statistical modeling, may provide a quantifiable and verifiable estimate of HHL in humans with normal hearing and with hearing loss. The current results are consistent with the view that inner hair cell and auditory nerve pathology may underlie suprathreshold auditory performance.
- 1 September 2018
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 39 (5) , 829-844
Using Thresholds in Noise to Identify Hidden Hearing Loss in Humans
Objectives: Recent animal studies suggest that noise-induced synaptopathy may underlie a phenomenon that has been labeled hidden hearing loss (HHL). Noise exposure preferentially damages low spontaneous-rate auditory nerve fibers, which are involved in the processing of moderate- to high-level sounds and are more resistant to masking by background noise. Therefore, the effect of synaptopathy may be more evident in suprathreshold measures of auditory function, especially in the presence of background noise. The purpose of this study was to develop a statistical model for estimating HHL in humans using thresholds in noise as the outcome variable and measures that reflect the integrity of sites along the auditory pathway as explanatory variables. Our working hypothesis is that HHL is evident in the portion of the variance observed in thresholds in noise that is not dependent on thresholds in quiet, because this residual variance retains statistical dependence on other measures of suprathreshold function. Design: Study participants included 13 adults with normal hearing (≤15 dB HL) and 20 adults with normal hearing at 1 kHz and sensorineural hearing loss at 4 kHz (>15 dB HL). Thresholds in noise were measured, and the residual of the correlation between thresholds in noise and thresholds in quiet, which we refer to as thresholds-in-noise residual, was used as the outcome measure for the model. Explanatory measures were as follows: (1) auditory brainstem response (ABR) waves I and V amplitudes; (2) electrocochleographic action potential and summating potential amplitudes; (3) distortion product otoacoustic emissions level; and (4) categorical loudness scaling. All measurements were made at two frequencies (1 and 4 kHz). ABR and electrocochleographic measurements were made at 80 and 100 dB peak equivalent sound pressure level, while wider ranges of levels were tested during distortion product otoacoustic emission and categorical loudness scaling measurements. A model relating the thresholds-in-noise residual and the explanatory measures was created using multiple linear regression analysis. Results: Predictions of thresholds-in-noise residual using the model accounted for 61% (p < 0.01) and 48% (p < 0.01) of the variance in the measured thresholds-in-noise residual at 1 and 4 kHz, respectively. Conclusions: Measures of thresholds in noise, the summating potential to action potential ratio, and ABR waves I and V amplitudes may be useful for the prediction of HHL in humans. With further development, our approach of quantifying HHL by the variance that remains in suprathreshold measures of auditory function after removing the variance due to thresholds in quiet, together with our statistical modeling, may provide a quantifiable and verifiable estimate of HHL in humans with normal hearing and with hearing loss. The current results are consistent with the view that inner hair cell and auditory nerve pathology may underlie suprathreshold auditory performance.
- 1 May 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (5) , 2994-3008
Influence of suppression on restoration of spectral loudness summation in listeners with hearing loss
Loudness depends on both the intensity and spectrum of a sound. Listeners with normal hearing perceive a broadband sound as being louder than an equal-level narrowband sound because loudness grows nonlinearly with level and is then summed across frequency bands. This difference in loudness as a function of bandwidth is reduced in listeners with sensorineural hearing loss (SNHL). Suppression, the reduction in the cochlear response to one sound by the simultaneous presentation of another sound, is also reduced in listeners with SNHL. Hearing-aid gain that is based on loudness measurements with pure tones may fail to restore normal loudness growth for broadband sounds. This study investigated whether hearing-aid amplification that mimics suppression can improve loudness summation for listeners with SNHL. Estimates of loudness summation were obtained using measurements of categorical loudness scaling (CLS). Stimuli were bandpass-filtered noises centered at 2 kHz with bandwidths in the range of 0.1–6.4 kHz. Gain was selected to restore normal loudness based on CLS measurements with pure tones. Gain that accounts for both compression and suppression resulted in better restoration of loudness summation, compared to compression alone. However, restoration was imperfect, suggesting that additional refinements to the signal processing and gain-prescription algorithms are needed.
- 1 May 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (5) , 2994-3008
Influence of suppression on restoration of spectral loudness summation in listeners with hearing loss
Loudness depends on both the intensity and spectrum of a sound. Listeners with normal hearing perceive a broadband sound as being louder than an equal-level narrowband sound because loudness grows nonlinearly with level and is then summed across frequency bands. This difference in loudness as a function of bandwidth is reduced in listeners with sensorineural hearing loss (SNHL). Suppression, the reduction in the cochlear response to one sound by the simultaneous presentation of another sound, is also reduced in listeners with SNHL. Hearing-aid gain that is based on loudness measurements with pure tones may fail to restore normal loudness growth for broadband sounds. This study investigated whether hearing-aid amplification that mimics suppression can improve loudness summation for listeners with SNHL. Estimates of loudness summation were obtained using measurements of categorical loudness scaling (CLS). Stimuli were bandpass-filtered noises centered at 2 kHz with bandwidths in the range of 0.1–6.4 kHz. Gain was selected to restore normal loudness based on CLS measurements with pure tones. Gain that accounts for both compression and suppression resulted in better restoration of loudness summation, compared to compression alone. However, restoration was imperfect, suggesting that additional refinements to the signal processing and gain-prescription algorithms are needed.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1809-1810
Otoacoustic emissions: Laboratory studies and clinical applications
Historically, the clinical potential of otoacoustic emissions (OAEs) to diagnosis hearing status was recognized prior to any consensus regarding their cochlear origin. In retrospect, we now understand refection-generated emissions as being closely aligned with Kemp’s (1980) concept of “cochlear echoes,” while distortion-generated emissions are necessarily tied to nonlinearities in cochlear mechanics. Research at the Boys Town National Research Hospital provided evidence supporting the cochlear origin of OAEs by demonstrating an approximate two-times relationship between an estimate of forward-latency derived from auditory brainstem responses and the round-trip latency of OAEs for tone-burst stimuli. Our application of clinical decision theory to distortion-product OAE levels, based on a large number of both normal-hearing and hearing-impaired ears, helped to establish (1) the validity of using DPOAEs to identify the presence of hearing loss and (2) guidelines for the interpretation of DPOAE levels in the clinic. Our exploration of reflection-generated emissions that we call cochlear reflectance is a continuation of our efforts to further extend the clinical potential of OAEs.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1809-1810
Otoacoustic emissions: Laboratory studies and clinical applications
Historically, the clinical potential of otoacoustic emissions (OAEs) to diagnosis hearing status was recognized prior to any consensus regarding their cochlear origin. In retrospect, we now understand refection-generated emissions as being closely aligned with Kemp’s (1980) concept of “cochlear echoes,” while distortion-generated emissions are necessarily tied to nonlinearities in cochlear mechanics. Research at the Boys Town National Research Hospital provided evidence supporting the cochlear origin of OAEs by demonstrating an approximate two-times relationship between an estimate of forward-latency derived from auditory brainstem responses and the round-trip latency of OAEs for tone-burst stimuli. Our application of clinical decision theory to distortion-product OAE levels, based on a large number of both normal-hearing and hearing-impaired ears, helped to establish (1) the validity of using DPOAEs to identify the presence of hearing loss and (2) guidelines for the interpretation of DPOAE levels in the clinic. Our exploration of reflection-generated emissions that we call cochlear reflectance is a continuation of our efforts to further extend the clinical potential of OAEs.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1738
Electroacoustic and behavioral evaluation of an open source audio processing platform
Hearing-aid (HA) research in academia is limited by the lack of wearable, reconfigurable, and reprogrammable audio processing platforms. We are developing such a platform, called the Tympan, which includes a Teensy 3.6 processor board that leverages the Arduino development environment while providing powerful computational capabilities. Custom-designed electronics are used for audio control, power management, and wireless communication. User-friendly software can be used to test the relative benefits of amplification variants. Users can also implement new algorithms and modify parameters of algorithms. This study evaluated an eight-channel HA implemented on the Tympan, relative to a commercially available HA. Gain was prescribed using NAL-NL1. Eighteen participants with hearing loss were tested. Electroacoustic tests included ANSI 3.22-2009 standard clinical measurements, the HA speech perception index, and the HA speech quality index. Behavioral tests included recognition of CASPA words in quiet and AzBio sentences in noise. The Tympan HA performed similar to the commercially-available HA on all tasks. Efforts are ongoing to miniaturize the Tympan hardware, increase flexibility of the software, and add features such as feedback management. The collaborative development and open sharing of algorithms facilitated by the Tympan will lead to advances in HA research and in other audio signal processing fields.
- 1 March 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (3_Suppleme) , 1738
Electroacoustic and behavioral evaluation of an open source audio processing platform
Hearing-aid (HA) research in academia is limited by the lack of wearable, reconfigurable, and reprogrammable audio processing platforms. We are developing such a platform, called the Tympan, which includes a Teensy 3.6 processor board that leverages the Arduino development environment while providing powerful computational capabilities. Custom-designed electronics are used for audio control, power management, and wireless communication. User-friendly software can be used to test the relative benefits of amplification variants. Users can also implement new algorithms and modify parameters of algorithms. This study evaluated an eight-channel HA implemented on the Tympan, relative to a commercially available HA. Gain was prescribed using NAL-NL1. Eighteen participants with hearing loss were tested. Electroacoustic tests included ANSI 3.22-2009 standard clinical measurements, the HA speech perception index, and the HA speech quality index. Behavioral tests included recognition of CASPA words in quiet and AzBio sentences in noise. The Tympan HA performed similar to the commercially-available HA on all tasks. Efforts are ongoing to miniaturize the Tympan hardware, increase flexibility of the software, and add features such as feedback management. The collaborative development and open sharing of algorithms facilitated by the Tympan will lead to advances in HA research and in other audio signal processing fields.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 040005
Modeling the level-dependent latency of cochlear transient responses
Human auditory brainstem responses to tone-burst stimuli exhibit remarkable consistency across tone frequency in the dependence of their latency on stimulus level. This level-dependent latency is simulated in a nonlinear, active, transmission-line model of cochlear mechanics. In this model, feedback forces due to outer hair cell (OHC) motility counteract damping in the cochlear partition, but only when they have the proper phase relative to vibration of the reticular lamina. The role of the tectorial membrane (TM) in controlling the phase the OHC force is crucial to the success of the model. In the model, TM tuning restricts the frequency range over which damping reduction is achieved. This restriction allows OHC motility to improve cochlear frequency resolution without creating instability. The only nonlinear element in the model represents OHC mechanoelectrical transduction. Level dependence of the latency of cochlear transients has been a controversial issue and its simulation presents a significant challenge to cochlear models because of the wide range of signal-processing constraints that it imposes on the model. The present model results suggest that the level dependence of ABR tone-burst latency at high frequencies is mostly due to cochlear mechanics and at low frequencies is mostly due to adaptation.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 040005
Modeling the level-dependent latency of cochlear transient responses
Human auditory brainstem responses to tone-burst stimuli exhibit remarkable consistency across tone frequency in the dependence of their latency on stimulus level. This level-dependent latency is simulated in a nonlinear, active, transmission-line model of cochlear mechanics. In this model, feedback forces due to outer hair cell (OHC) motility counteract damping in the cochlear partition, but only when they have the proper phase relative to vibration of the reticular lamina. The role of the tectorial membrane (TM) in controlling the phase the OHC force is crucial to the success of the model. In the model, TM tuning restricts the frequency range over which damping reduction is achieved. This restriction allows OHC motility to improve cochlear frequency resolution without creating instability. The only nonlinear element in the model represents OHC mechanoelectrical transduction. Level dependence of the latency of cochlear transients has been a controversial issue and its simulation presents a significant challenge to cochlear models because of the wide range of signal-processing constraints that it imposes on the model. The present model results suggest that the level dependence of ABR tone-burst latency at high frequencies is mostly due to cochlear mechanics and at low frequencies is mostly due to adaptation.
- 1 October 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (4) , 2246-2255
Reflectance measurement validation using acoustic horns
Variability in wideband acoustic reflectance (and absorbance) measurements adversely affects the clinical utility of reflectance for diagnosis of middle-ear disorders. A reflectance standard would encourage consistency across different measurement systems and help identify calibration related issues. Theoretical equations exist for the reflectance of finite-length exponential, conical, and parabolic acoustic horns. Reflectance measurements were repeatedly made in each of these three horn shapes and the results were compared to the corresponding theoretical reflectance. A method is described of adjusting acoustic impedance measurements to compensate for spreading of the wave front that propagates from the small diameter sound port of the probe to the larger diameter of the acoustic cavity. Agreement between measured and theoretical reflectance was less than 1 dB at most frequencies in the range from 0.2 to 10 kHz. Pearson correlation coefficients were greater than 0.95 between measured and theoretical time-domain reflectance within the flare region of the horns. The agreement suggests that the distributed reflectance of acoustic horns may be useful for validating reflectance measurements made in human ear canals; however, refinements to reflectance measurement methods may still be needed.
- 1 October 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (4) , 2246-2255
Reflectance measurement validation using acoustic horns
Variability in wideband acoustic reflectance (and absorbance) measurements adversely affects the clinical utility of reflectance for diagnosis of middle-ear disorders. A reflectance standard would encourage consistency across different measurement systems and help identify calibration related issues. Theoretical equations exist for the reflectance of finite-length exponential, conical, and parabolic acoustic horns. Reflectance measurements were repeatedly made in each of these three horn shapes and the results were compared to the corresponding theoretical reflectance. A method is described of adjusting acoustic impedance measurements to compensate for spreading of the wave front that propagates from the small diameter sound port of the probe to the larger diameter of the acoustic cavity. Agreement between measured and theoretical reflectance was less than 1 dB at most frequencies in the range from 0.2 to 10 kHz. Pearson correlation coefficients were greater than 0.95 between measured and theoretical time-domain reflectance within the flare region of the horns. The agreement suggests that the distributed reflectance of acoustic horns may be useful for validating reflectance measurements made in human ear canals; however, refinements to reflectance measurement methods may still be needed.
- 1 April 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 137 (4) , 1899-1913
Categorical loudness scaling and equal-loudness contours in listeners with normal hearing and hearing loss
This study describes procedures for constructing equal-loudness contours (ELCs) in units of phons from categorical loudness scaling (CLS) data and characterizes the impact of hearing loss on these estimates of loudness. Additionally, this study developed a metric, level-dependent loudness loss, which uses CLS data to specify the deviation from normal loudness perception at various loudness levels and as function of frequency for an individual listener with hearing loss. CLS measurements were made in 87 participants with hearing loss and 61 participants with normal hearing. An assessment of the reliability of CLS measurements was conducted on a subset of the data. CLS measurements were reliable. There was a systematic increase in the slope of the low-level segment of the CLS functions with increase in the degree of hearing loss. ELCs derived from CLS measurements were similar to standardized ELCs (International Organization for Standardization, ISO 226:2003). The presence of hearing loss decreased the vertical spacing of the ELCs, reflecting loudness recruitment and reduced cochlear compression. Representing CLS data in phons may lead to wider acceptance of CLS measurements. Like the audiogram that specifies hearing loss at threshold, level-dependent loudness loss describes deficit for suprathreshold sounds. Such information may have implications for the fitting of hearing aids.
- 1 April 2015
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 137 (4) , 1899-1913
Categorical loudness scaling and equal-loudness contours in listeners with normal hearing and hearing loss
This study describes procedures for constructing equal-loudness contours (ELCs) in units of phons from categorical loudness scaling (CLS) data and characterizes the impact of hearing loss on these estimates of loudness. Additionally, this study developed a metric, level-dependent loudness loss, which uses CLS data to specify the deviation from normal loudness perception at various loudness levels and as function of frequency for an individual listener with hearing loss. CLS measurements were made in 87 participants with hearing loss and 61 participants with normal hearing. An assessment of the reliability of CLS measurements was conducted on a subset of the data. CLS measurements were reliable. There was a systematic increase in the slope of the low-level segment of the CLS functions with increase in the degree of hearing loss. ELCs derived from CLS measurements were similar to standardized ELCs (International Organization for Standardization, ISO 226:2003). The presence of hearing loss decreased the vertical spacing of the ELCs, reflecting loudness recruitment and reduced cochlear compression. Representing CLS data in phons may lead to wider acceptance of CLS measurements. Like the audiogram that specifies hearing loss at threshold, level-dependent loudness loss describes deficit for suprathreshold sounds. Such information may have implications for the fitting of hearing aids.
- 1 January 2015
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 36 (1) , 111-124
Reliability and Clinical Test Performance of Cochlear Reflectance
Objective: Cochlear reflectance (CR) is the cochlear contribution to ear-canal reflectance. CR is equivalent to an otoacoustic emission (OAE) deconvolved by forward pressure in the ear canal. Similar to other OAE measures, CR level is related to cochlear status. When measured using wideband noise stimuli, potential advantages of CR over other types of OAEs include (1) the capability to cover a wider frequency range more efficiently by requiring fewer measurements, (2) minimal influence on the recorded emission from the measurement system and middle ear, (3) lack of entrainment of spontaneous OAEs, and (4) easier interpretation because of the existence of an equivalent linear model, which validates the application of linear systems theory. The purposes of this study were to evaluate the reliability, assess the accuracy in a clinical screening paradigm, and determine the relation of CR to audiometric thresholds. Thus, this study represents an initial assessment of the clinical utility of CR. Design: Data were collected from 32 normal-hearing and 58 hearing-impaired participants. A wideband noise stimulus presented at seven stimulus levels (10 to 70 dB SPL, 10 dB steps) was used to elicit the CR. Reliability of CR was assessed using Cronbach’s α, standard error of measurement, and absolute differences between CR data from three separate test sessions. Test performance was evaluated using clinical decision theory. The ability of CR to predict audiometric thresholds was evaluated using regression analysis. Results: CR repeatability across test sessions was similar to that of other clinical measurements. However, both the accuracy with which CR distinguished normal-hearing from hearing-impaired ears and the accuracy with which CR predicted audiometric thresholds were less than those reported in previous studies using distortion-product OAE measurements. Conclusions: CR measurements are repeatable between test sessions, can be used to predict auditory status, and are related to audiometric thresholds. However, under current conditions, CR does not perform as well as other OAE measurements. Further developments in CR measurement and analysis methods may improve performance. CR has theoretical advantages for cochlear modeling, which may lead to improved interpretation of cochlear status.
- 1 January 2015
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 36 (1) , 111-124
Reliability and Clinical Test Performance of Cochlear Reflectance
Objective: Cochlear reflectance (CR) is the cochlear contribution to ear-canal reflectance. CR is equivalent to an otoacoustic emission (OAE) deconvolved by forward pressure in the ear canal. Similar to other OAE measures, CR level is related to cochlear status. When measured using wideband noise stimuli, potential advantages of CR over other types of OAEs include (1) the capability to cover a wider frequency range more efficiently by requiring fewer measurements, (2) minimal influence on the recorded emission from the measurement system and middle ear, (3) lack of entrainment of spontaneous OAEs, and (4) easier interpretation because of the existence of an equivalent linear model, which validates the application of linear systems theory. The purposes of this study were to evaluate the reliability, assess the accuracy in a clinical screening paradigm, and determine the relation of CR to audiometric thresholds. Thus, this study represents an initial assessment of the clinical utility of CR. Design: Data were collected from 32 normal-hearing and 58 hearing-impaired participants. A wideband noise stimulus presented at seven stimulus levels (10 to 70 dB SPL, 10 dB steps) was used to elicit the CR. Reliability of CR was assessed using Cronbach’s α, standard error of measurement, and absolute differences between CR data from three separate test sessions. Test performance was evaluated using clinical decision theory. The ability of CR to predict audiometric thresholds was evaluated using regression analysis. Results: CR repeatability across test sessions was similar to that of other clinical measurements. However, both the accuracy with which CR distinguished normal-hearing from hearing-impaired ears and the accuracy with which CR predicted audiometric thresholds were less than those reported in previous studies using distortion-product OAE measurements. Conclusions: CR measurements are repeatable between test sessions, can be used to predict auditory status, and are related to audiometric thresholds. However, under current conditions, CR does not perform as well as other OAE measurements. Further developments in CR measurement and analysis methods may improve performance. CR has theoretical advantages for cochlear modeling, which may lead to improved interpretation of cochlear status.