Michael Mayer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Mayer has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Wolfgang Hitzl
Research Office (Biostatistics), Paracelsus Medical University, Müllner Hauptstrasse 48, 5020 Salzburg, Austria
3 shared publications Arvind von Keudell
MGH, Boston, MA, US
2 shared publicationsHeiko Koller
German Scoliosis Center Bad Wildungen, Werner-Wicker-Klinik
2 shared publicationsHerbert Resch
Paracelsus Medical University
2 shared publications- Herbert Resch
Paracelsus Medical University Salzburg
2 shared publications Juliane Zenner
German Scoliosis Center Bad Wildungen, Werner-Wicker-Klinik
2 shared publications
Latest Publications
- 1 November 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (22) , E1195-E1197
Leriche-Like Syndrome as a Delayed Complication Following Posterior Instrumentation of a Traumatic L1 Fracture
Case report and review of literature. Case report of an acute Leriche-like syndrome as an unusual complication after posterior transpedicular instrumentation of an L1 fracture. Injuries to the aorta after pedicle screw placement are rare. Reports exist about acute hemorrhage, erosions, and pseudoaneurysm formation. A 47-year-old female developed an acute occlusion of the infrarenal aorta after posterior transpedicular instrumentation of an L1 burst-fracture. The patient presented with increasing sensation of hypothermia in both lower extremities and cyanosis of the toes, as well as claudication-like symptoms 15 days after the initial surgery. CT angiography showed bicortical placement of the left pedicle screw at L2 with perforation of the anterior cortex of 2.5 mm and complete obliteration of the infrarenal aorta up to the bifurcation. The patient was treated with resection of the aorta and implantation of a silver graft prosthesis. Preoperative symptoms resolved immediately after surgery without reoccurrence. Although rare, the risk of iatrogenic injuries to the aorta during spine surgery exists, several complications have previously been described. However, this is the first report of an acute Leriche-like syndrome after posterior instrumentation of the spine. Whereas bicortical pedicle screw placement in selected cases of posterior spinal instrumentation is intended, one has to be aware of the possible risks, as in our case where an acute aortic obliteration was observed. Preoperative CT-based planning of surgery and profound knowledge of the neurovascular anatomy is mandatory. Level of Evidence: 5
- 1 November 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (22) , E1195-E1197
Leriche-Like Syndrome as a Delayed Complication Following Posterior Instrumentation of a Traumatic L1 Fracture
Case report and review of literature. Case report of an acute Leriche-like syndrome as an unusual complication after posterior transpedicular instrumentation of an L1 fracture. Injuries to the aorta after pedicle screw placement are rare. Reports exist about acute hemorrhage, erosions, and pseudoaneurysm formation. A 47-year-old female developed an acute occlusion of the infrarenal aorta after posterior transpedicular instrumentation of an L1 burst-fracture. The patient presented with increasing sensation of hypothermia in both lower extremities and cyanosis of the toes, as well as claudication-like symptoms 15 days after the initial surgery. CT angiography showed bicortical placement of the left pedicle screw at L2 with perforation of the anterior cortex of 2.5 mm and complete obliteration of the infrarenal aorta up to the bifurcation. The patient was treated with resection of the aorta and implantation of a silver graft prosthesis. Preoperative symptoms resolved immediately after surgery without reoccurrence. Although rare, the risk of iatrogenic injuries to the aorta during spine surgery exists, several complications have previously been described. However, this is the first report of an acute Leriche-like syndrome after posterior instrumentation of the spine. Whereas bicortical pedicle screw placement in selected cases of posterior spinal instrumentation is intended, one has to be aware of the possible risks, as in our case where an acute aortic obliteration was observed. Preoperative CT-based planning of surgery and profound knowledge of the neurovascular anatomy is mandatory. Level of Evidence: 5
- 30 September 2013
- Published by Elsevier in The Spine Journal
- Vol. 13 (9) , S47-S48
Long-Term Investigation of Operative Treatment of Thoracolumbar Burst Fractures
- 30 September 2013
- Published by Elsevier in The Spine Journal
- Vol. 13 (9) , S47-S48
Long-Term Investigation of Operative Treatment of Thoracolumbar Burst Fractures
- Open Access
- 28 August 2012
- Published by Springer Nature in European Spine Journal
- Vol. 22 (1) , 46-53
Comparison of revision strategies for failed C2-posterior cervical pedicle screws: a biomechanical study
With increasing usage within challenging biomechanical constructs, failures of C2 posterior cervical pedicle screws (C2-pCPSs) will occur. The purpose of the study was therefore to investigate the biomechanical characteristics of two revision techniques after the failure of C2-pCPSs. Twelve human C2 vertebrae were tested in vitro in a biomechanical study to compare two strategies for revision screws after failure of C2-pCPSs. C2 pedicles were instrumented using unicortical 3.5-mm CPS bilaterally (Synapse/Synthes, Switzerland). Insertion accuracy was verified by fluoroscopy. C2 vertebrae were potted and fixed in an electromechanical testing machine with the screw axis coaxial to the pullout direction. Pullout testing was conducted with load and displacement data taken continuously. The peak load to failure was measured in newtons (N) and is reported as the pullout resistance (POR). After pullout, two revision strategies were tested in each vertebra. In Group-1, revision was performed with 4.0-mm C2-pCPSs. In Group-2, revision was performed with C2-pedicle bone-plastic combined with the use of a 4-mm C2-pCPSs. For the statistical analysis, the POR between screws was compared using absolute values (N) and the POR of the revision techniques normalized to that of the primary procedures (%). The POR of primary 3.5-mm CPSs was 1,140.5 ± 539.6 N for Group-1 and 1,007.7 ± 362.5 N for Group-2; the difference was not significant. In the revision setting, the POR in Group-1 was 705.8 ± 449.1 N, representing a reduction of 38.1 ± 32.9 % compared with that of primary screw fixation. For Group-2, the POR was 875.3 ± 367.9 N, representing a reduction of 13.1 ± 23.4 %. A statistical analysis showed a significantly higher POR for Group-2 compared with Group-1 (p = 0.02). Although the statistics showed a significantly reduced POR for both revision strategies compared with primary fixation (p < 0.001/p = 0.001), the loss of POR (in %) in Group-1 was significantly higher compared with the loss in Group-2 (p = 0.04). Using a larger-diameter screw combined with the application of a pedicle bone-plastic, the POR can be significantly increased compared with the use of only an increased screw diameter.
- 28 August 2012
- Published by Springer Nature in European Spine Journal
- Vol. 22 (1) , 46-53
Open AccessComparison of revision strategies for failed C2-posterior cervical pedicle screws: a biomechanical study
With increasing usage within challenging biomechanical constructs, failures of C2 posterior cervical pedicle screws (C2-pCPSs) will occur. The purpose of the study was therefore to investigate the biomechanical characteristics of two revision techniques after the failure of C2-pCPSs. Twelve human C2 vertebrae were tested in vitro in a biomechanical study to compare two strategies for revision screws after failure of C2-pCPSs. C2 pedicles were instrumented using unicortical 3.5-mm CPS bilaterally (Synapse/Synthes, Switzerland). Insertion accuracy was verified by fluoroscopy. C2 vertebrae were potted and fixed in an electromechanical testing machine with the screw axis coaxial to the pullout direction. Pullout testing was conducted with load and displacement data taken continuously. The peak load to failure was measured in newtons (N) and is reported as the pullout resistance (POR). After pullout, two revision strategies were tested in each vertebra. In Group-1, revision was performed with 4.0-mm C2-pCPSs. In Group-2, revision was performed with C2-pedicle bone-plastic combined with the use of a 4-mm C2-pCPSs. For the statistical analysis, the POR between screws was compared using absolute values (N) and the POR of the revision techniques normalized to that of the primary procedures (%). The POR of primary 3.5-mm CPSs was 1,140.5 ± 539.6 N for Group-1 and 1,007.7 ± 362.5 N for Group-2; the difference was not significant. In the revision setting, the POR in Group-1 was 705.8 ± 449.1 N, representing a reduction of 38.1 ± 32.9 % compared with that of primary screw fixation. For Group-2, the POR was 875.3 ± 367.9 N, representing a reduction of 13.1 ± 23.4 %. A statistical analysis showed a significantly higher POR for Group-2 compared with Group-1 (p = 0.02). Although the statistics showed a significantly reduced POR for both revision strategies compared with primary fixation (p < 0.001/p = 0.001), the loss of POR (in %) in Group-1 was significantly higher compared with the loss in Group-2 (p = 0.04). Using a larger-diameter screw combined with the application of a pedicle bone-plastic, the POR can be significantly increased compared with the use of only an increased screw diameter.
- 24 May 2011
- Published by Springer Nature in European Spine Journal
- Vol. 20 (9) , 1441-1449
Efficacy of anterior odontoid screw fixation in the elderly patient: a CT-based biometrical analysis of odontoid fractures
In the elderly population, reported union rates with anterior odontoid screw fixation (AOSF) for odontoid fracture (OF) treatment vary between 23 and 93% when using plain radiographs. However, recent research revealed poor interobserver reliability for fusion assessment using plain radiographs compared to CT scans. Therefore, union rates in patients aged ≥60 years treated with AOSF have to be revisited using CT scans and factors for non-union to be analysed. Prospectively gathered consecutively treated patients using AOSF for odontoid fracture with age ≥60 years were reviewed. Medical charts were assessed for demographics, clinical outcomes and complications. Patients’ preoperative radiographs and CT scans were analysed to characterize fracture morphology and type, fracture displacement, presence of atlanto-dental osteoarthritis as well as a detailed morphometric assessment of fracture surfaces (in mm2). CT scans performed after a minimum of 3 months postoperatively were analysed for fracture union. Those patients not showing CT-based evidence of completely fused odontoid fracture were invited for radiographic follow-up at a minimum of 6 months follow-up. Follow-up CT-scan were studied for odontoid union as well as the number of screws used and the square surface of screws used for AOSF and the related corticocancellous osseous healing surface of the odontoid fragment (in %) were calculated. Patients were stratified whether they achieved osseous union or fibrous non-union. Patients with a non-union were subjected to flexion–extension lateral radiographs and the non-union defined as stable if no motion was detected. The sample included 13 male (72%) and 5 female (18%) patients. The interval from injury to AOSF was 4.1 ± 5.3 days (0–16 days). Age at injury was 78.1 ± 7.6 years (60–87 years) and follow-up was 75.7 ± 50.8 months (4.2–150.2 months). 10 patients had dislocated fractures, 14 had Type II and 4 “shallow” Type III fractures according to the Anderson classification, 2 had stable C1-ring fractures, 8 had displayed atlanto-dental osteoarthritis. Fracture square surface was 127.1 ± 50.9 mm2 (56.3–215.9 mm2) and osseous healing surface was 84.0 ± 6.8% (67.6–91.1%). CT-based analysis revealed osseous union in 9 (50%) and non-union in 9 patients (50%). Union rates correlated with increased fracture surface (P = 0.02). Statistical analysis revealed a trend that the usage of two screws with AOSF correlates with increased fusion rates (P = 0.06). Stability at C1–2 was achieved in 89% of patients. CT scans are accepted as the standard of reference to assess osseous union. The current study offers an objective insight into the union rates of odontoid fractures treated with AOSF using CT scans in consecutive series of 18 patients ≥60 years. Literature serves evidence that elderly patients with unstable OF benefit from early surgical stabilization. However, although using AOSF for unstable OF yields segmental stability at C1–2 in a high number of patients as echoed in the current study, our analysis stressed that using follow-up CT scans in comparison to biplanar radiographs dramatically reduces osseous union rates compared to those previously reported for AOSF.
- 24 May 2011
- Published by Springer Nature in European Spine Journal
- Vol. 20 (9) , 1441-1449
Efficacy of anterior odontoid screw fixation in the elderly patient: a CT-based biometrical analysis of odontoid fractures
In the elderly population, reported union rates with anterior odontoid screw fixation (AOSF) for odontoid fracture (OF) treatment vary between 23 and 93% when using plain radiographs. However, recent research revealed poor interobserver reliability for fusion assessment using plain radiographs compared to CT scans. Therefore, union rates in patients aged ≥60 years treated with AOSF have to be revisited using CT scans and factors for non-union to be analysed. Prospectively gathered consecutively treated patients using AOSF for odontoid fracture with age ≥60 years were reviewed. Medical charts were assessed for demographics, clinical outcomes and complications. Patients’ preoperative radiographs and CT scans were analysed to characterize fracture morphology and type, fracture displacement, presence of atlanto-dental osteoarthritis as well as a detailed morphometric assessment of fracture surfaces (in mm2). CT scans performed after a minimum of 3 months postoperatively were analysed for fracture union. Those patients not showing CT-based evidence of completely fused odontoid fracture were invited for radiographic follow-up at a minimum of 6 months follow-up. Follow-up CT-scan were studied for odontoid union as well as the number of screws used and the square surface of screws used for AOSF and the related corticocancellous osseous healing surface of the odontoid fragment (in %) were calculated. Patients were stratified whether they achieved osseous union or fibrous non-union. Patients with a non-union were subjected to flexion–extension lateral radiographs and the non-union defined as stable if no motion was detected. The sample included 13 male (72%) and 5 female (18%) patients. The interval from injury to AOSF was 4.1 ± 5.3 days (0–16 days). Age at injury was 78.1 ± 7.6 years (60–87 years) and follow-up was 75.7 ± 50.8 months (4.2–150.2 months). 10 patients had dislocated fractures, 14 had Type II and 4 “shallow” Type III fractures according to the Anderson classification, 2 had stable C1-ring fractures, 8 had displayed atlanto-dental osteoarthritis. Fracture square surface was 127.1 ± 50.9 mm2 (56.3–215.9 mm2) and osseous healing surface was 84.0 ± 6.8% (67.6–91.1%). CT-based analysis revealed osseous union in 9 (50%) and non-union in 9 patients (50%). Union rates correlated with increased fracture surface (P = 0.02). Statistical analysis revealed a trend that the usage of two screws with AOSF correlates with increased fusion rates (P = 0.06). Stability at C1–2 was achieved in 89% of patients. CT scans are accepted as the standard of reference to assess osseous union. The current study offers an objective insight into the union rates of odontoid fractures treated with AOSF using CT scans in consecutive series of 18 patients ≥60 years. Literature serves evidence that elderly patients with unstable OF benefit from early surgical stabilization. However, although using AOSF for unstable OF yields segmental stability at C1–2 in a high number of patients as echoed in the current study, our analysis stressed that using follow-up CT scans in comparison to biplanar radiographs dramatically reduces osseous union rates compared to those previously reported for AOSF.