Tessa S. Cook
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tessa S. Cook has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
William W. Boonn
Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, USA
4 shared publicationsWoojin Kim
Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, USA
4 shared publicationsAnand Sundaram
Department of Bioengineering, University of Pennsylvania School of Engineering and Applied Sciences, Philadelphia, USA
1 shared publication- Andrew Douglas Arnold Maidment
University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, United States
1 shared publication Gregory Couch
Radimetrics, Inc
1 shared publicationNicholas Papanicolaou
Hospital of the University of Pennsylvania
1 shared publication
Latest Publications
- 1 January 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (1) , 113-116
The Importance of Imaging Informatics and Informaticists in the Implementation of AI
- 1 January 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (1) , 113-116
The Importance of Imaging Informatics and Informaticists in the Implementation of AI
- 27 August 2013
- Published by Springer Nature in Abdominal Radiology
- Vol. 38 (6) , 1190-1196
Perspectives on radiation dose in abdominal imaging
Reported instances of patients’ overexposure to imaging-related radiation have spurred the radiology and medical physics communities to identify and develop methods for decreasing the amount of radiation used to achieve diagnostic-quality images. These initiatives include examining and optimizing conventional CT scanning parameters, introducing innovative scan protocols, and incorporating novel dose reduction technologies. The greatest challenge to effective dose reduction in the abdomen and pelvis remains patient size. Here, we review the state of the art in abdominopelvic CT in both adult and pediatric patients and describe some of our own efforts in dose reduction for these types of examinations.
- 27 August 2013
- Published by Springer Nature in Abdominal Radiology
- Vol. 38 (6) , 1190-1196
Perspectives on radiation dose in abdominal imaging
Reported instances of patients’ overexposure to imaging-related radiation have spurred the radiology and medical physics communities to identify and develop methods for decreasing the amount of radiation used to achieve diagnostic-quality images. These initiatives include examining and optimizing conventional CT scanning parameters, introducing innovative scan protocols, and incorporating novel dose reduction technologies. The greatest challenge to effective dose reduction in the abdomen and pelvis remains patient size. Here, we review the state of the art in abdominopelvic CT in both adult and pediatric patients and describe some of our own efforts in dose reduction for these types of examinations.
- 29 January 2013
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 26 (4) , 663-667
An Interactive RADIANCE Toolkit for Customizable CT Dose Monitoring and Reporting
- 29 January 2013
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 26 (4) , 663-667
An Interactive RADIANCE Toolkit for Customizable CT Dose Monitoring and Reporting
- 24 January 2013
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 26 (4) , 657-662
Using the Microsoft Kinect for Patient Size Estimation and Radiation Dose Normalization: Proof of Concept and Initial Validation
Monitoring patients' imaging-related radiation is currently a hot topic, but there are many obstacles to accurate, patient-specific dose estimation. While some, such as easier access to dose data and parameters, have been overcome, the challenge remains as to how accurately these dose estimates reflect the actual dose received by the patient. The main parameter that is often not considered is patient size. There are many surrogates—weight, body mass index, effective diameter—but none of these truly reflect the three-dimensional “size” of an individual. In this work, we present and evaluate a novel approach to estimating patient volume using the Microsoft Kinect™, a combination RGB camera-infrared depth sensor device. The goal of using this device is to generate a three-dimensional estimate of patient size, in order to more effectively model the dimensions of the anatomy of interest and not only enable better normalization of dose estimates but also promote more patient-specific protocoling of future CT examinations. Preliminary testing and validation of this system reveals good correlation when individuals are standing upright with their arms by their sides, but demonstrates some variation with arm position. Further evaluation and testing is necessary with multiple patient positions and in both adult and pediatric patients. Correlation with other patient size metrics will also be helpful, as the ideal measure of patient “size” may in fact be a combination of existing metrics and newly developed techniques.
- 24 January 2013
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 26 (4) , 657-662
Using the Microsoft Kinect for Patient Size Estimation and Radiation Dose Normalization: Proof of Concept and Initial Validation
Monitoring patients' imaging-related radiation is currently a hot topic, but there are many obstacles to accurate, patient-specific dose estimation. While some, such as easier access to dose data and parameters, have been overcome, the challenge remains as to how accurately these dose estimates reflect the actual dose received by the patient. The main parameter that is often not considered is patient size. There are many surrogates—weight, body mass index, effective diameter—but none of these truly reflect the three-dimensional “size” of an individual. In this work, we present and evaluate a novel approach to estimating patient volume using the Microsoft Kinect™, a combination RGB camera-infrared depth sensor device. The goal of using this device is to generate a three-dimensional estimate of patient size, in order to more effectively model the dimensions of the anatomy of interest and not only enable better normalization of dose estimates but also promote more patient-specific protocoling of future CT examinations. Preliminary testing and validation of this system reveals good correlation when individuals are standing upright with their arms by their sides, but demonstrates some variation with arm position. Further evaluation and testing is necessary with multiple patient positions and in both adult and pediatric patients. Correlation with other patient size metrics will also be helpful, as the ideal measure of patient “size” may in fact be a combination of existing metrics and newly developed techniques.
- 28 July 2011
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (1) , 179-188
An Algorithm for Intelligent Sorting of CT-Related Dose Parameters
Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)—an indirect estimate of radiation dose—requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, “arterial” could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.
- 28 July 2011
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (1) , 179-188
An Algorithm for Intelligent Sorting of CT-Related Dose Parameters
Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)—an indirect estimate of radiation dose—requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, “arterial” could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.
- 1 November 2010
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 7 (11) , 871-877
Automated Extraction of Radiation Dose Information for CT Examinations
- 1 November 2010
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 7 (11) , 871-877
Automated Extraction of Radiation Dose Information for CT Examinations