Anna Klimek-Turek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna Klimek-Turek has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Tadeusz H. Dzido
Physical Chemistry Department, Medical University of Lublin, Chodźki 4A, 20-093, Lublin, Poland
4 shared publications- Kamila Jaglińska
Department of Physical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland
3 shared publications - Tadeusz Henryk Dzido
Department of Physical Chemistry, Pharmaceutical Faculty, Medical University of Lublin, 4A Chodźki Street, Lublin, 20-093, Poland
3 shared publications - Andrzej Wysokiński
Department of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland
2 shared publications - Beata Polak
Department of Physical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland
2 shared publications - Robert Błaszczyk
Department of Cardiology, Medical University of Lublin, Lublin, Poland
2 shared publications
Latest Publications
- Open Access
Comparison of the Determination of Some Antihypertensive Drugs in Clinical Human Plasma Samples by Solvent Front Position Extraction and Precipitation Modes
The determination of the selected antihypertensive drugs in human plasma samples with the novel solvent front position extraction (SFPE) technique is presented. The SFPE procedure combined with LC-MS/MS analysis was used for the first time to prepare a clinical sample containing the drugs mentioned above from different therapeutic groups. The effectiveness of our approach was compared with the precipitation method. The latter technique is usually used to prepare biological samples in routine laboratories. During the experiments, the substances of interest and the internal standard were separated from other matrix components using a prototype horizontal chamber for thin-layer chromatography/high-performance thin-layer chromatography (TLC/HPTLC) with a moving pipette powered by a 3D mechanism, which distributed the solvent on the adsorbent layer. Detection of the six antihypertensive drugs was performed by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) in multiple reaction monitoring (MRM) mode. Results obtained by SFPE were very satisfactory (linearity R2 ≥ 0.981; %RSD ≤ 6%; LOD and LOQ were in the range of 0.06–9.78 ng/mL and 0.17–29.64 ng/mL, respectively). The recovery was in the range of 79.88–120.36%. Intra-day and inter-day precision had a percentage coefficient of variation (CV) in the range of 1.10–9.74%. The procedure is simple and highly effective. It includes the automation of TLC chromatogram development, which significantly reduced the number of manual operations performed, the time of sample preparation and solvent consumption.
Open AccessComparison of the Determination of Some Antihypertensive Drugs in Clinical Human Plasma Samples by Solvent Front Position Extraction and Precipitation Modes
The determination of the selected antihypertensive drugs in human plasma samples with the novel solvent front position extraction (SFPE) technique is presented. The SFPE procedure combined with LC-MS/MS analysis was used for the first time to prepare a clinical sample containing the drugs mentioned above from different therapeutic groups. The effectiveness of our approach was compared with the precipitation method. The latter technique is usually used to prepare biological samples in routine laboratories. During the experiments, the substances of interest and the internal standard were separated from other matrix components using a prototype horizontal chamber for thin-layer chromatography/high-performance thin-layer chromatography (TLC/HPTLC) with a moving pipette powered by a 3D mechanism, which distributed the solvent on the adsorbent layer. Detection of the six antihypertensive drugs was performed by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) in multiple reaction monitoring (MRM) mode. Results obtained by SFPE were very satisfactory (linearity R2 ≥ 0.981; %RSD ≤ 6%; LOD and LOQ were in the range of 0.06–9.78 ng/mL and 0.17–29.64 ng/mL, respectively). The recovery was in the range of 79.88–120.36%. Intra-day and inter-day precision had a percentage coefficient of variation (CV) in the range of 1.10–9.74%. The procedure is simple and highly effective. It includes the automation of TLC chromatogram development, which significantly reduced the number of manual operations performed, the time of sample preparation and solvent consumption.
- Open Access
Preparation of Antihypertensive Drugs in Biological Matrix with Solvent Front Position Extraction for LC–MS/MS Analysis
Solvent front position extraction procedure was used to prepare biological samples containing selected antihypertensive drugs (ramipril, lercanidipine, indapamide, valsartan, hydrochlorothiazide, perindopril, and nebivolol). Substances separated from the biological matrix components (bovine serum albumin) were quantified by means of liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Sample preparation process was performed with the use of a prototype horizontal chamber with a moving pipette driven by a 3D printer mechanism enabling a controlled eluent flow velocity. Application of this device was advantageous for simultaneous preparation of several samples for further quantitative analysis, with a synchronized reduction of manual operations and solvent consumption. Quantitative results obtained for the majority of the investigated antihypertensive drugs in a complex biological matrix were satisfactory. The values of the %RSD were around 5% for six of the seven substances (with the exception of indapamide). The method exhibits a suitable accuracy (the relative error percentage was below 10% for most drugs). The values of LOD and LOQ were in the range of 1.19 µg/L–8.53 µg/L and 3.61 µg/L–25.8 µg/L, respectively.
Open AccessPreparation of Antihypertensive Drugs in Biological Matrix with Solvent Front Position Extraction for LC–MS/MS Analysis
Solvent front position extraction procedure was used to prepare biological samples containing selected antihypertensive drugs (ramipril, lercanidipine, indapamide, valsartan, hydrochlorothiazide, perindopril, and nebivolol). Substances separated from the biological matrix components (bovine serum albumin) were quantified by means of liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Sample preparation process was performed with the use of a prototype horizontal chamber with a moving pipette driven by a 3D printer mechanism enabling a controlled eluent flow velocity. Application of this device was advantageous for simultaneous preparation of several samples for further quantitative analysis, with a synchronized reduction of manual operations and solvent consumption. Quantitative results obtained for the majority of the investigated antihypertensive drugs in a complex biological matrix were satisfactory. The values of the %RSD were around 5% for six of the seven substances (with the exception of indapamide). The method exhibits a suitable accuracy (the relative error percentage was below 10% for most drugs). The values of LOD and LOQ were in the range of 1.19 µg/L–8.53 µg/L and 3.61 µg/L–25.8 µg/L, respectively.
- Open Access
Comparison of the Retention and Separation Selectivity of Aromatic Hydrocarbons with Polar Groups in RP-HPLC Systems with Different Stationary Phases and Eluents
In this manuscript, the retention of aromatic hydrocarbons with polar groups has been compared for systems with various nonpolar columns of the types from C3 to C18 and different mobile phases composed of methanol, acetonitrile, or tetrahydrofuran as modifiers. The selectivity separation of the solutes in systems with different adsorbents, when one eluent modifier is swapped by another, has been explained, taking into account molecular interactions of the solutes with components of the stationary phase region (i.e., extracted modifier depending on the chain length of the stationary phase).
Open AccessComparison of the Retention and Separation Selectivity of Aromatic Hydrocarbons with Polar Groups in RP-HPLC Systems with Different Stationary Phases and Eluents
In this manuscript, the retention of aromatic hydrocarbons with polar groups has been compared for systems with various nonpolar columns of the types from C3 to C18 and different mobile phases composed of methanol, acetonitrile, or tetrahydrofuran as modifiers. The selectivity separation of the solutes in systems with different adsorbents, when one eluent modifier is swapped by another, has been explained, taking into account molecular interactions of the solutes with components of the stationary phase region (i.e., extracted modifier depending on the chain length of the stationary phase).
- Open Access
- 15 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Solvent front position extraction with semi-automatic device as a powerful sample preparation procedure to quantitatitation of tryptophan in human plasma
In the paper the results of the tryptophan determination in human plasma samples prepared with the novel Solvent Front Position Extraction (SFPE) technique are presented. The SFPE procedure is used for preparation of real biological sample for the first time. The results obtained using SFPE are compared with those using the classical sample preparation procedure. Under the optimal conditions, tryptophan and its internal standard were separated from other plasma compounds (matrix) as a small common zone/spot on a chromatographic plate using semiautomatic device equipped with moving pipet, which distributed developing solvent on the adsorbent layer. Tryptophan and the internal standard were evenly distributed within the small common zone from that the both substances were extracted and the solution obtained was transferred to quantitation with LC–MS and MS techniques. The determination results are satisfactory, the percentage values of relative error and RSD relative standard deviation do not exceed 5%. The procedure is characterized by simplicity, high analysis throughput, very good sample purification and seems to be easy applicable to other biological samples with these advantages mentioned.
- 15 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Open AccessSolvent front position extraction with semi-automatic device as a powerful sample preparation procedure to quantitatitation of tryptophan in human plasma
In the paper the results of the tryptophan determination in human plasma samples prepared with the novel Solvent Front Position Extraction (SFPE) technique are presented. The SFPE procedure is used for preparation of real biological sample for the first time. The results obtained using SFPE are compared with those using the classical sample preparation procedure. Under the optimal conditions, tryptophan and its internal standard were separated from other plasma compounds (matrix) as a small common zone/spot on a chromatographic plate using semiautomatic device equipped with moving pipet, which distributed developing solvent on the adsorbent layer. Tryptophan and the internal standard were evenly distributed within the small common zone from that the both substances were extracted and the solution obtained was transferred to quantitation with LC–MS and MS techniques. The determination results are satisfactory, the percentage values of relative error and RSD relative standard deviation do not exceed 5%. The procedure is characterized by simplicity, high analysis throughput, very good sample purification and seems to be easy applicable to other biological samples with these advantages mentioned.
- 1 August 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1625, 461277
Retardation of some drugs in thin-layer chromatographic systems with impregnated silica gel plates with hen's egg white and bovine serum albumin
- 1 August 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1625, 461277
Retardation of some drugs in thin-layer chromatographic systems with impregnated silica gel plates with hen's egg white and bovine serum albumin
- 1 May 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1618, 460912
Optimization of the procedure of solvent front position extraction for preparation of multi-component sample for instrumental analysis
- 1 May 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1618, 460912
Optimization of the procedure of solvent front position extraction for preparation of multi-component sample for instrumental analysis
- Open Access
Solvent Front Position Extraction with Semi-Automatic Device as a Powerful Sample Preparation Procedure Prior to Quantitative Instrumental Analysis
The new prototype device is applied to the Solvent Front Position Extraction (SFPE) sample preparation procedure. The mobile phase is deposited onto the chromatographic plate adsorbent layer by the pipette, which is moved, according to programmed movement path, by a 3D printer mechanism. The application of the prototype device to SFPE procedure leads to the increased repeatability of the results and significant reduction of the analysis time in comparison to the classical procedure of chromatogram development. Additionally, the new equipment allows use procedures that are not possible to run using the classic chromatogram development. In this paper, the results of manual and semi-automatic sample preparation with SFPE are compared and the possible application of this prototype device is discussed.
Open AccessSolvent Front Position Extraction with Semi-Automatic Device as a Powerful Sample Preparation Procedure Prior to Quantitative Instrumental Analysis
The new prototype device is applied to the Solvent Front Position Extraction (SFPE) sample preparation procedure. The mobile phase is deposited onto the chromatographic plate adsorbent layer by the pipette, which is moved, according to programmed movement path, by a 3D printer mechanism. The application of the prototype device to SFPE procedure leads to the increased repeatability of the results and significant reduction of the analysis time in comparison to the classical procedure of chromatogram development. Additionally, the new equipment allows use procedures that are not possible to run using the classic chromatogram development. In this paper, the results of manual and semi-automatic sample preparation with SFPE are compared and the possible application of this prototype device is discussed.