Lawrence A. Sasso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lawrence A. Sasso has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey D. Zahn
Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, USA
3 shared publications - Akif Ündar
Penn State College of Medicine
2 shared publications Akif Ündar
Pediatric Cardiovascular Research Center Penn State Hershey College of Medicine Penn State Hershey Children's Hospital Hershey PA USA
1 shared publicationIan H. Johnston
Rutgers, The State University of New Jersey
1 shared publicationJeffrey D. Zahn
Department of Biomedical Engineering Rutgers, The State University of New Jersey Piscataway NJ USA
1 shared publicationKiana Aran
Department of Biomedical Engineering Rutgers, The State University of New Jersey Piscataway NJ USA
1 shared publication
Latest Publications
- 11 January 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (1) , E9-E17
Continuous Monitoring of Inflammation Biomarkers During Simulated Cardiopulmonary Bypass Using a Microfluidic Immunoassay Device—A Pilot Study
This work demonstrates the use of a continuous online monitoring system for tracking systemic inflammation biomarkers during cardiopulmonary bypass (CPB) procedures. The ability to monitor inflammation biomarkers during CPB will allow surgical teams to actively treat inflammation and reduce harmful effects on postoperative morbidity and mortality, enabling improved patient outcomes. A microfluidic device has been designed which allows automation of the individual processing steps of a microbead immunoassay to allow continuous tracking of antigen concentrations. Preliminary experiments have demonstrated that the results produced by the microimmunoassay are comparable to results produced from a standard enzyme‐linked immunosorbent assay (r = 0.98). Additionally, integration of the assay with a simulated CPB circuit has been demonstrated with temporal tracking of C3a concentrations within blood continuously sampled from the circuit. The presented work describes the motivation, design challenges, and preliminary experimental results of this project.
- 11 January 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (1) , E9-E17
Continuous Monitoring of Inflammation Biomarkers During Simulated Cardiopulmonary Bypass Using a Microfluidic Immunoassay Device—A Pilot Study
This work demonstrates the use of a continuous online monitoring system for tracking systemic inflammation biomarkers during cardiopulmonary bypass (CPB) procedures. The ability to monitor inflammation biomarkers during CPB will allow surgical teams to actively treat inflammation and reduce harmful effects on postoperative morbidity and mortality, enabling improved patient outcomes. A microfluidic device has been designed which allows automation of the individual processing steps of a microbead immunoassay to allow continuous tracking of antigen concentrations. Preliminary experiments have demonstrated that the results produced by the microimmunoassay are comparable to results produced from a standard enzyme‐linked immunosorbent assay (r = 0.98). Additionally, integration of the assay with a simulated CPB circuit has been demonstrated with temporal tracking of C3a concentrations within blood continuously sampled from the circuit. The presented work describes the motivation, design challenges, and preliminary experimental results of this project.
- 17 April 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (4) , 603-612
Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
A microfluidic platform is presented which fully automates all incubation steps of a three-stage, multiplexed magnetic bead immunoassay, such as the Luminex® xMAP technology. Magnetic actuation is used to transfer the microbeads between co-infused adjacent laminar flow streams to transport the beads into and out of incubation and wash solutions, with extended incubation channels to allow sufficient bead incubation times (1–30 min, commonly 5 min per stage) to enable high-sensitivity. The serial incubation steps of the immunoassay are completed in succession within the device with no operator interaction, and the continuous flow operation with magnetic bead transfer defines the incubation sequencing requiring no external fluidic controls beyond syringe pump infusion. The binding kinetics of the assay is empirically characterized to determine the required incubation times for specific assay sensitivities in the range 1 pg/ml to 100 ng/ml. By using a Luminex® xMAP duplex assay, concurrent detection of IL-6 and TNF-α was demonstrated on-chip with a detection range 10 pg/ml to 1 ng/ml. This technology enables rapid automation of magnetic microbead assays, and has the potential to perform continuous concentration monitoring.
- 17 April 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (4) , 603-612
Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
A microfluidic platform is presented which fully automates all incubation steps of a three-stage, multiplexed magnetic bead immunoassay, such as the Luminex® xMAP technology. Magnetic actuation is used to transfer the microbeads between co-infused adjacent laminar flow streams to transport the beads into and out of incubation and wash solutions, with extended incubation channels to allow sufficient bead incubation times (1–30 min, commonly 5 min per stage) to enable high-sensitivity. The serial incubation steps of the immunoassay are completed in succession within the device with no operator interaction, and the continuous flow operation with magnetic bead transfer defines the incubation sequencing requiring no external fluidic controls beyond syringe pump infusion. The binding kinetics of the assay is empirically characterized to determine the required incubation times for specific assay sensitivities in the range 1 pg/ml to 100 ng/ml. By using a Luminex® xMAP duplex assay, concurrent detection of IL-6 and TNF-α was demonstrated on-chip with a detection range 10 pg/ml to 1 ng/ml. This technology enables rapid automation of magnetic microbead assays, and has the potential to perform continuous concentration monitoring.
- 11 December 2009
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 9 (2-3) , 253-265
Autonomous magnetically actuated continuous flow microimmunofluorocytometry assay
This article presents a microfluidic device which integrates autonomous serial immunofluorocytometry binding reactions of cytometric beads with fluorescence detection and quantification in a continuous flow environment. The microdevice assay is intended to alleviate the extensive benchwork and large sample volumes used when conducting traditional immunoassays, without requiring complex external controls. The technology is based on the miniaturization and automation of the serial processing steps of an antigen sandwich immunoassay, with integrated fluorescence detection using paramagnetic microbeads. The continuous flow design may enable temporal tracking of time-varying protein concentrations in a continuously infused sample for clinical applications, specifically for monitoring inflammation marker proteins in blood produced during cardiac surgeries involving cardiopulmonary bypass (CPB) procedures. The device operation was first validated via a single incubation device which measured the concentration of a fluorescently labeled biotin molecule using streptavidin-coated paramagnetic cytometric beads. Subsequently, a dual incubation device was tested with samples of the anaphylatoxin complement protein C3a, and was shown to be capable of differentiating between samples at typical systemic concentrations of the protein (1–5 μg/ml), with very low sample usage (<6 μl/h). It is believed that this continuous flow, automated microimmunosensor technology will be a platform for high sample rate immunoassays capable of tracking and more thoroughly characterizing the systemic inflammation process, and may aid in the development of better treatment options for systemic inflammation during and after CPB.
- 11 December 2009
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 9 (2-3) , 253-265
Autonomous magnetically actuated continuous flow microimmunofluorocytometry assay
This article presents a microfluidic device which integrates autonomous serial immunofluorocytometry binding reactions of cytometric beads with fluorescence detection and quantification in a continuous flow environment. The microdevice assay is intended to alleviate the extensive benchwork and large sample volumes used when conducting traditional immunoassays, without requiring complex external controls. The technology is based on the miniaturization and automation of the serial processing steps of an antigen sandwich immunoassay, with integrated fluorescence detection using paramagnetic microbeads. The continuous flow design may enable temporal tracking of time-varying protein concentrations in a continuously infused sample for clinical applications, specifically for monitoring inflammation marker proteins in blood produced during cardiac surgeries involving cardiopulmonary bypass (CPB) procedures. The device operation was first validated via a single incubation device which measured the concentration of a fluorescently labeled biotin molecule using streptavidin-coated paramagnetic cytometric beads. Subsequently, a dual incubation device was tested with samples of the anaphylatoxin complement protein C3a, and was shown to be capable of differentiating between samples at typical systemic concentrations of the protein (1–5 μg/ml), with very low sample usage (<6 μl/h). It is believed that this continuous flow, automated microimmunosensor technology will be a platform for high sample rate immunoassays capable of tracking and more thoroughly characterizing the systemic inflammation process, and may aid in the development of better treatment options for systemic inflammation during and after CPB.
- 1 January 2008
- Published by ASME International
- p. 941-944
Continuous Microfluidic Biosensing With Conjugated Paramagnetic Beads
A microfluidic biosensing assay has been designed and tested with streptavidin coated paramagnetic microbeads and fluorescently conjugated biotin (Biotin-FITC). The device is a three-inlet, three-outlet channel made by soft lithography of polydimethylsiloxane (PDMS). A novel magnetic actuation scheme is used to manipulate the beads within the channel. The device has proven capable of measuring the antigen concentration of a continuous sample stream. It is proposed that this technology could be applied as a real-time immunosensing assay.
- 1 January 2008
- Published by ASME International
- p. 941-944
Continuous Microfluidic Biosensing With Conjugated Paramagnetic Beads
A microfluidic biosensing assay has been designed and tested with streptavidin coated paramagnetic microbeads and fluorescently conjugated biotin (Biotin-FITC). The device is a three-inlet, three-outlet channel made by soft lithography of polydimethylsiloxane (PDMS). A novel magnetic actuation scheme is used to manipulate the beads within the channel. The device has proven capable of measuring the antigen concentration of a continuous sample stream. It is proposed that this technology could be applied as a real-time immunosensing assay.