Marcel C. M. Rutten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marcel C. M. Rutten has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Frans N. van de Vosse
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
4 shared publications - Richard G. P. Lopata
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
4 shared publications - Jan-Willem Muller
Biomedical Engineering, Technische Universiteit Eindhoven, De Rondom 70, Eindhoven, 5600 MB, NETHERLANDS
3 shared publications - Marc R. H. M. van Sambeek
Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology
3 shared publications - Min Wu
Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
3 shared publications - Hans-Martin Schwab
Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 31 July 2023
- Published by Elsevier in Ultrasonics
- Vol. 135, 107127
Enabling strain imaging in realistic Eulerian ultrasound simulation methods
- 31 July 2023
- Published by Elsevier in Ultrasonics
- Vol. 135, 107127
Open AccessEnabling strain imaging in realistic Eulerian ultrasound simulation methods
- 12 March 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (5) , e192-e198
MarioHeart: Novel In-Vitro Flow Model for Testing Heart Valve Prostheses and Anticoagulant Therapies
Mechanical heart valve (MHV) prostheses present a risk of thromboembolic complications despite antithrombotic therapy. Further steps in the development of more hemocompatible MHVs and new anticoagulants are impeded due to the lack of adequate in-vitro models. With the development of a novel in-vitro model (MarioHeart), a pulsatile flow similar to the arterial circulation is emulated. The MarioHeart design owns unique features as 1) a single MHV within a torus with low surface/volume ratio, 2) a closed loop system, and 3) a dedicated external control system driving the oscillating rotational motion of the torus. For verification purposes, a blood analog fluid seeded with particles was used to assess fluid velocity and flow rate using a speckle tracking method on high-speed video recordings of the rotating model. The flow rate resembled the physiological flow rate in the aortic root, in both shape and amplitude. Additional in-vitro runs with porcine blood showed thrombi on the MHV associated with the suture ring, which is similar to the in-vivo situation. MarioHeart is a simple design which induces well-defined fluid dynamics resulting in physiologically nonturbulent flow without stasis of the blood. MarioHeart seems suitable for testing the thrombogenicity of MHVs and the potential of new anticoagulants.
- 12 March 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (5) , e192-e198
MarioHeart: Novel In-Vitro Flow Model for Testing Heart Valve Prostheses and Anticoagulant Therapies
Mechanical heart valve (MHV) prostheses present a risk of thromboembolic complications despite antithrombotic therapy. Further steps in the development of more hemocompatible MHVs and new anticoagulants are impeded due to the lack of adequate in-vitro models. With the development of a novel in-vitro model (MarioHeart), a pulsatile flow similar to the arterial circulation is emulated. The MarioHeart design owns unique features as 1) a single MHV within a torus with low surface/volume ratio, 2) a closed loop system, and 3) a dedicated external control system driving the oscillating rotational motion of the torus. For verification purposes, a blood analog fluid seeded with particles was used to assess fluid velocity and flow rate using a speckle tracking method on high-speed video recordings of the rotating model. The flow rate resembled the physiological flow rate in the aortic root, in both shape and amplitude. Additional in-vitro runs with porcine blood showed thrombi on the MHV associated with the suture ring, which is similar to the in-vivo situation. MarioHeart is a simple design which induces well-defined fluid dynamics resulting in physiologically nonturbulent flow without stasis of the blood. MarioHeart seems suitable for testing the thrombogenicity of MHVs and the potential of new anticoagulants.
- Open Access
- 14 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 096005-17
Modeling toolchain for realistic simulation of photoacoustic data acquisition
Photoacoustic (PA) imaging is a relatively new biomedical imaging modality that employs the wide variety of optical properties found in tissue to generate contrast with ultrasound (US) resolution. Increasingly sophisticated PA setups and signal processing methods are being developed to enhance the capabilities of PA imaging. Phantom experiments are often performed to validate new methods, to characterize PA setups, and to generate training datasets for machine learning. However, the scarcity of high-quality phantoms and the absence of a ground truth in in vitro experiments impedes research. Numerical modeling approaches can provide an in silico research environment, in which all relevant physical parameters are known and controllable. Therefore, an accurate and validated PA imaging toolchain that can generate realistic PA images may accelerate the general development of PA imaging. However, generating realistic PA image data with simulations remains a great challenge. In this research, we propose a thoroughly validated, quantitative, and flexible PA imaging modeling toolchain and demonstrate its capability to simulate the acquisition of PA signals of a physical PA system in both phantoms and complex tissues.
- 14 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 096005-17
Open AccessModeling toolchain for realistic simulation of photoacoustic data acquisition
Photoacoustic (PA) imaging is a relatively new biomedical imaging modality that employs the wide variety of optical properties found in tissue to generate contrast with ultrasound (US) resolution. Increasingly sophisticated PA setups and signal processing methods are being developed to enhance the capabilities of PA imaging. Phantom experiments are often performed to validate new methods, to characterize PA setups, and to generate training datasets for machine learning. However, the scarcity of high-quality phantoms and the absence of a ground truth in in vitro experiments impedes research. Numerical modeling approaches can provide an in silico research environment, in which all relevant physical parameters are known and controllable. Therefore, an accurate and validated PA imaging toolchain that can generate realistic PA images may accelerate the general development of PA imaging. However, generating realistic PA image data with simulations remains a great challenge. In this research, we propose a thoroughly validated, quantitative, and flexible PA imaging modeling toolchain and demonstrate its capability to simulate the acquisition of PA signals of a physical PA system in both phantoms and complex tissues.
- Open Access
- 6 November 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (11) , 116003-16
SVD-based filtering to detect intraplaque hemorrhage using single wavelength photoacoustic imaging
Stroke is the second leading cause of death and the third leading cause of disability worldwide.1 The major cause of stroke is the rupture of plaque in the carotid artery. These rupture-prone plaques (vulnerable plaques) are characterized by the presence of a lipid-rich core, a thin fibrous cap, and intraplaque hemorrhages (IPH).2 The current clinical guideline to determine plaque vulnerability, however, is based on the grade of stenosis, which is often assessed by duplex ultrasound (US).3 When the grade of stenosis is over 70% and less than 100%, the patient will undergo surgery.
- 6 November 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (11) , 116003-16
Open AccessSVD-based filtering to detect intraplaque hemorrhage using single wavelength photoacoustic imaging
Stroke is the second leading cause of death and the third leading cause of disability worldwide.1 The major cause of stroke is the rupture of plaque in the carotid artery. These rupture-prone plaques (vulnerable plaques) are characterized by the presence of a lipid-rich core, a thin fibrous cap, and intraplaque hemorrhages (IPH).2 The current clinical guideline to determine plaque vulnerability, however, is based on the grade of stenosis, which is often assessed by duplex ultrasound (US).3 When the grade of stenosis is over 70% and less than 100%, the patient will undergo surgery.
- 1 October 2014
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 53, 141-153
An in silico case study of idiopathic dilated cardiomyopathy via a multi-scale model of the cardiovascular system
- 1 October 2014
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 53, 141-153
An in silico case study of idiopathic dilated cardiomyopathy via a multi-scale model of the cardiovascular system
- 1 March 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (5) , 1027-1034
Identification of artery wall stiffness: In vitro validation and in vivo results of a data assimilation procedure applied to a 3D fluid–structure interaction model
- 1 March 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (5) , 1027-1034
Identification of artery wall stiffness: In vitro validation and in vivo results of a data assimilation procedure applied to a 3D fluid–structure interaction model
- 31 October 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (10) , 1875-1886
A Novel Experimental Approach for Three-Dimensional Geometry Assessment of Calcified Human Stenotic Arteries in Vitro
- 31 October 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (10) , 1875-1886
A Novel Experimental Approach for Three-Dimensional Geometry Assessment of Calcified Human Stenotic Arteries in Vitro
- Open Access
- 10 May 2007
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 7 (2) , 127-137
Non-linear viscoelastic behavior of abdominal aortic aneurysm thrombus
The objective of this work was to determine the linear and non-linear viscoelastic behavior of abdominal aortic aneurysm thrombus and to study the changes in mechanical properties throughout the thickness of the thrombus. Samples are gathered from thrombi of seven patients. Linear viscoelastic data from oscillatory shear experiments show that the change of properties throughout the thrombus is different for each thrombus. Furthermore the variations found within one thrombus are of the same order of magnitude as the variation between patients. To study the non-linear regime, stress relaxation experiments are performed. To describe the phenomena observed experimentally, a non-linear multimode model is presented. The parameters for this model are obtained by fitting this model successfully to the experiments. The model cannot only describe the average stress response for all thrombus samples but also the highest and lowest stress responses. To determine the influence on the wall stress of the behavior observed the model proposed needs to implemented in the finite element wall stress analysis.
- 10 May 2007
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 7 (2) , 127-137
Open AccessNon-linear viscoelastic behavior of abdominal aortic aneurysm thrombus
The objective of this work was to determine the linear and non-linear viscoelastic behavior of abdominal aortic aneurysm thrombus and to study the changes in mechanical properties throughout the thickness of the thrombus. Samples are gathered from thrombi of seven patients. Linear viscoelastic data from oscillatory shear experiments show that the change of properties throughout the thrombus is different for each thrombus. Furthermore the variations found within one thrombus are of the same order of magnitude as the variation between patients. To study the non-linear regime, stress relaxation experiments are performed. To describe the phenomena observed experimentally, a non-linear multimode model is presented. The parameters for this model are obtained by fitting this model successfully to the experiments. The model cannot only describe the average stress response for all thrombus samples but also the highest and lowest stress responses. To determine the influence on the wall stress of the behavior observed the model proposed needs to implemented in the finite element wall stress analysis.