Galateia J. Kazakia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Galateia J. Kazakia has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
S. Majumdar
2 shared publicationsSharmila Majumdar
2 shared publications- Sharmila Majumdar
Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco; San Francisco, CA USA
2 shared publications A. J. Burghardt
Musculoskeletal and Quantitative Imaging Research Group, Department of Radiology, University of California, San Francisco, California 94158
1 shared publicationAndrew J Burghardt
Musculoskeletal and Quantitative Imaging Research Group, Department of Radiology, University of California, San Francisco, California, USA
1 shared publicationAndrew J. Burghardt
1 shared publication
Latest Publications
- Open Access
- 2 December 2009
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (2) , 235-246
In Vivo Evaluation of the Presence of Bone Marrow in Cortical Porosity in Postmenopausal Osteopenic Women
This is the first observational study examining cortical porosity in vivo in postmenopausal osteopenic women and to incorporate data from two different imaging modalities to further examine the nature of cortical porosity. The goal of this study was to combine high-resolution peripheral computed tomography (HR-pQCT) images, which contain high spatial resolution information of the cortical structure, and magnetic resonance (MR) images, which allow the visualization of soft tissues such as bone marrow, to observe the amount of cortical porosity that contains bone marrow in postmenopausal osteopenic women. The radius of 49 and the tibia of 51 postmenopausal osteopenic women (age 56 ± 3.7) were scanned using both HR-pQCT and MR imaging. A normalized mutual information registration algorithm was used to obtain a three-dimensional rigid transform which aligned the MR image to the HR-pQCT image. The aligned images allowed for the visualization of bone marrow in cortical pores. From the HR-pQCT image, the percent cortical porosity, the number of cortical pores, and the size of each cortical pore was determined. By overlaying the aligned MR and HR-pQCT images, the percent of cortical pores containing marrow, the number of cortical pores containing marrow, and the size of each cortical pore containing marrow were measured. While the amount of cortical porosity did not vary greatly between subjects, the type of cortical pore, containing marrow vs. not containing marrow, varied highly between subjects. The results suggest that cortical pore spaces contain components of varying composition, and that there may be more than one mechanism for the development of cortical porosity.
- 2 December 2009
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (2) , 235-246
Open AccessIn Vivo Evaluation of the Presence of Bone Marrow in Cortical Porosity in Postmenopausal Osteopenic Women
This is the first observational study examining cortical porosity in vivo in postmenopausal osteopenic women and to incorporate data from two different imaging modalities to further examine the nature of cortical porosity. The goal of this study was to combine high-resolution peripheral computed tomography (HR-pQCT) images, which contain high spatial resolution information of the cortical structure, and magnetic resonance (MR) images, which allow the visualization of soft tissues such as bone marrow, to observe the amount of cortical porosity that contains bone marrow in postmenopausal osteopenic women. The radius of 49 and the tibia of 51 postmenopausal osteopenic women (age 56 ± 3.7) were scanned using both HR-pQCT and MR imaging. A normalized mutual information registration algorithm was used to obtain a three-dimensional rigid transform which aligned the MR image to the HR-pQCT image. The aligned images allowed for the visualization of bone marrow in cortical pores. From the HR-pQCT image, the percent cortical porosity, the number of cortical pores, and the size of each cortical pore was determined. By overlaying the aligned MR and HR-pQCT images, the percent of cortical pores containing marrow, the number of cortical pores containing marrow, and the size of each cortical pore containing marrow were measured. While the amount of cortical porosity did not vary greatly between subjects, the type of cortical pore, containing marrow vs. not containing marrow, varied highly between subjects. The results suggest that cortical pore spaces contain components of varying composition, and that there may be more than one mechanism for the development of cortical porosity.
- 19 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (7Part1) , 3170-3179
Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: Comparison with synchrotron radiation microcomputed tomography and ash measurements
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High‐resolution three‐dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography ; however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone‐shaped beam geometry complicate assessment of TMD by conventional . The goal of this study was to evaluate ‐based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, measures of bone mineral content (BMC) and TMD were compared to those obtained by and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads , vertebrae , and proximal tibiae . Cylinders were imaged in saline on a polychromatic system at an isotropic voxel size of . Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)‐resin wedge phantoms of 200 and . imaging was performed at an isotropic voxel size of at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. ‐based BMC values were not affected by altering the beam hardening correction. Volume‐averaged TMD values calculated by the two corrections were significantly different in high volume fraction specimens only, with the correction resulting in a higher TMD value. and provided significantly different measurements of both BMC and TMD . In high volume fraction specimens, with correction resulted in BMC and TMD values and lower, respectively, than values. In low volume fraction specimens, with correction resulted in BMC and TMD values and lower, respectively, than values. and values were well‐correlated when volume fraction groups were considered individually (BMC ; TMD ). Ash mass and density were higher than the equivalents by in high volume fraction specimens and in low volume fraction specimens . BMC values calculated by tomography were highly correlated with ash mass (ash versus ; ash versus ). TMD values calculated by tomography were moderately correlated with ash density (ash versus ; ash versus ). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the data, which were reduced (but not eliminated) using the beam hardening correction, and did not exist in the data. This study represents the first quantitative comparison of mineralization evaluation against and gravimetry. Our results indicate that mineralization measures are underestimated but well‐correlated with and gravimetric data, particularly when volume fraction groups are considered individually.
- 19 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (7Part1) , 3170-3179
Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: Comparison with synchrotron radiation microcomputed tomography and ash measurements
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High‐resolution three‐dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography ; however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone‐shaped beam geometry complicate assessment of TMD by conventional . The goal of this study was to evaluate ‐based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, measures of bone mineral content (BMC) and TMD were compared to those obtained by and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads , vertebrae , and proximal tibiae . Cylinders were imaged in saline on a polychromatic system at an isotropic voxel size of . Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)‐resin wedge phantoms of 200 and . imaging was performed at an isotropic voxel size of at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. ‐based BMC values were not affected by altering the beam hardening correction. Volume‐averaged TMD values calculated by the two corrections were significantly different in high volume fraction specimens only, with the correction resulting in a higher TMD value. and provided significantly different measurements of both BMC and TMD . In high volume fraction specimens, with correction resulted in BMC and TMD values and lower, respectively, than values. In low volume fraction specimens, with correction resulted in BMC and TMD values and lower, respectively, than values. and values were well‐correlated when volume fraction groups were considered individually (BMC ; TMD ). Ash mass and density were higher than the equivalents by in high volume fraction specimens and in low volume fraction specimens . BMC values calculated by tomography were highly correlated with ash mass (ash versus ; ash versus ). TMD values calculated by tomography were moderately correlated with ash density (ash versus ; ash versus ). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the data, which were reduced (but not eliminated) using the beam hardening correction, and did not exist in the data. This study represents the first quantitative comparison of mineralization evaluation against and gravimetry. Our results indicate that mineralization measures are underestimated but well‐correlated with and gravimetric data, particularly when volume fraction groups are considered individually.
- 1 April 2008
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 23 (4) , 463-474
In Vivo Determination of Bone Structure in Postmenopausal Women: A Comparison of HR-pQCT and High-Field MR Imaging
Bone structural measures obtained by two noninvasive imaging tools—3T MRI and HR-pQCT—were compared. Significant but moderate correlations and 2- to 4-fold discrepancies in parameter values were detected, suggesting that differences in acquisition and analysis must be considered when interpreting data from these imaging modalities. Introduction: High-field MRI and high resolution (HR)-pQCT are currently being used in longitudinal bone structure studies. Substantial differences in acquisition and analysis between these modalities may influence the quantitative data produced and could potentially influence clinical decisions based on their results. Our goal was to compare trabecular and cortical bone structural measures obtained in vivo by 3T MRI and HR-pQCT. Materials and Methods: Postmenopausal osteopenic women (n = 52) were recruited for this study. HR-pQCT imaging of the radius and tibia was performed using the XtremeCT scanner, with a voxel size of 82 × 82 × 82 μm3. MR imaging was performed on a 3T Signa scanner using SSFP imaging sequences, with a pixel size of 156 × 156 μm2 and slice thickness of 500 μm. Structure parameters were calculated using standard HR-pQCT and MRI analysis techniques. Relationships between measures derived from HR-pQCT, MRI, and DXA were studied. Results: Significant correlations between HR-pQCT and MRI parameters were found (p < 0.0001) and were strongest for Tb.N (r2 = 0.52), Ct.Th (r2 = 0.59), and site-specific Tb.Sp (r2 = 0.54–0.60). MRI and HR-pQCT provided statistically different values of structure parameters (p < 0.0001), with BV/TV and Tb.Th exhibiting the largest discrepancies (MR/HR-pQCT = 3–4). Although differences in the Tb.N values were statistically significant, the mean differences were on the order of our reproducibility measurements. Systematic differences between MRI and HR-pQCT analysis procedures leading to discrepancies in cortical thickness values were observed, with MRI values consistently higher. Minimal correlations were found between MRI or HR-pQCT parameters and DXA BMD or T-score, except between HR-pQCT measures at the radius and the ultradistal radius T-scores, where moderate correlations were found (r2 = 0.19–0.58). Conclusions: This study provides unique insight into two emerging noninvasive tools for bone structure evaluation. Our findings highlight the significant influence of analysis technique on results of in vivo assessment and underscore the importance of accounting for these differences when interpreting results from these modalities.
- 1 April 2008
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 23 (4) , 463-474
In Vivo Determination of Bone Structure in Postmenopausal Women: A Comparison of HR-pQCT and High-Field MR Imaging
Bone structural measures obtained by two noninvasive imaging tools—3T MRI and HR-pQCT—were compared. Significant but moderate correlations and 2- to 4-fold discrepancies in parameter values were detected, suggesting that differences in acquisition and analysis must be considered when interpreting data from these imaging modalities. Introduction: High-field MRI and high resolution (HR)-pQCT are currently being used in longitudinal bone structure studies. Substantial differences in acquisition and analysis between these modalities may influence the quantitative data produced and could potentially influence clinical decisions based on their results. Our goal was to compare trabecular and cortical bone structural measures obtained in vivo by 3T MRI and HR-pQCT. Materials and Methods: Postmenopausal osteopenic women (n = 52) were recruited for this study. HR-pQCT imaging of the radius and tibia was performed using the XtremeCT scanner, with a voxel size of 82 × 82 × 82 μm3. MR imaging was performed on a 3T Signa scanner using SSFP imaging sequences, with a pixel size of 156 × 156 μm2 and slice thickness of 500 μm. Structure parameters were calculated using standard HR-pQCT and MRI analysis techniques. Relationships between measures derived from HR-pQCT, MRI, and DXA were studied. Results: Significant correlations between HR-pQCT and MRI parameters were found (p < 0.0001) and were strongest for Tb.N (r2 = 0.52), Ct.Th (r2 = 0.59), and site-specific Tb.Sp (r2 = 0.54–0.60). MRI and HR-pQCT provided statistically different values of structure parameters (p < 0.0001), with BV/TV and Tb.Th exhibiting the largest discrepancies (MR/HR-pQCT = 3–4). Although differences in the Tb.N values were statistically significant, the mean differences were on the order of our reproducibility measurements. Systematic differences between MRI and HR-pQCT analysis procedures leading to discrepancies in cortical thickness values were observed, with MRI values consistently higher. Minimal correlations were found between MRI or HR-pQCT parameters and DXA BMD or T-score, except between HR-pQCT measures at the radius and the ultradistal radius T-scores, where moderate correlations were found (r2 = 0.19–0.58). Conclusions: This study provides unique insight into two emerging noninvasive tools for bone structure evaluation. Our findings highlight the significant influence of analysis technique on results of in vivo assessment and underscore the importance of accounting for these differences when interpreting results from these modalities.
- 26 February 2007
- Published by Wiley in Journal of Microscopy
- Vol. 225 (2) , 109-117
Automated high‐resolution three‐dimensional fluorescence imaging of large biological specimens
We describe a novel automated technique for visualizing the three-dimensional distribution of fluorochrome-labelled components, in which image resolution is uncoupled from specimen size. This method is based on computer numerically controlled milling technology and combines an arrayed imaging technique with fluorescence capabilities. Fluorescent signals are segmented by emission spectra such that multiple fluorochromes present within a single specimen may be reconstructed and visualized individually or as a group. The automated nature of the system minimizes the workload and time involved in image capture and volume reconstruction. As an application, the system was used to image zones of fluorochrome-labelled microdamage within an 8-mm diameter cylinder of trabecular bone at a voxel size of 3 x 3 x 8 microm3. Our reconstruction of this specimen provides a visual map and quantitative measures of the volume of damage present throughout the cylinder, clearly demonstrating the interpretive power afforded by three-dimensional visualization. The three-dimensional nature of this highly automated and adaptable system has the potential to facilitate new diagnostic tools and techniques with application to a wide range of biological and medical research fields.
- 26 February 2007
- Published by Wiley in Journal of Microscopy
- Vol. 225 (2) , 109-117
Automated high‐resolution three‐dimensional fluorescence imaging of large biological specimens
We describe a novel automated technique for visualizing the three-dimensional distribution of fluorochrome-labelled components, in which image resolution is uncoupled from specimen size. This method is based on computer numerically controlled milling technology and combines an arrayed imaging technique with fluorescence capabilities. Fluorescent signals are segmented by emission spectra such that multiple fluorochromes present within a single specimen may be reconstructed and visualized individually or as a group. The automated nature of the system minimizes the workload and time involved in image capture and volume reconstruction. As an application, the system was used to image zones of fluorochrome-labelled microdamage within an 8-mm diameter cylinder of trabecular bone at a voxel size of 3 x 3 x 8 microm3. Our reconstruction of this specimen provides a visual map and quantitative measures of the volume of damage present throughout the cylinder, clearly demonstrating the interpretive power afforded by three-dimensional visualization. The three-dimensional nature of this highly automated and adaptable system has the potential to facilitate new diagnostic tools and techniques with application to a wide range of biological and medical research fields.
- 1 June 2006
- Published by Springer Nature in Reviews in Endocrine and Metabolic Disorders
- Vol. 7 (1-2) , 67-74
New imaging technologies in the diagnosis of osteoporosis
In the context of osteoporosis, bone quality—which encompasses trabecular and cortical micro-architecture, mass, and tissue mechanical & compositional properties—plays an important and as yet undiscovered role. Non-invasive assessment of bone quality has recently received considerable attention, as bone density alone has not been able to predict existing or future osteoporotic fractures, or to explain therapeutic effects of emerging treatments. The goal of this review, therefore, is to present imaging modalities and related analysis methods capable of assessing bone quality for improved diagnosis and care of osteoporotic individuals. The techniques described include quantitative ultrasound, quantitative computed tomography, peripheral quantitative tomography, micro computed tomography, magnetic resonance, radiographic texture analysis, as well as finite element analysis based on the above-mentioned imaging modalities. The performance of these techniques in predicting osteoporotic fracture and assessing strength indices are discussed.
- 1 June 2006
- Published by Springer Nature in Reviews in Endocrine and Metabolic Disorders
- Vol. 7 (1-2) , 67-74
New imaging technologies in the diagnosis of osteoporosis
In the context of osteoporosis, bone quality—which encompasses trabecular and cortical micro-architecture, mass, and tissue mechanical & compositional properties—plays an important and as yet undiscovered role. Non-invasive assessment of bone quality has recently received considerable attention, as bone density alone has not been able to predict existing or future osteoporotic fractures, or to explain therapeutic effects of emerging treatments. The goal of this review, therefore, is to present imaging modalities and related analysis methods capable of assessing bone quality for improved diagnosis and care of osteoporotic individuals. The techniques described include quantitative ultrasound, quantitative computed tomography, peripheral quantitative tomography, micro computed tomography, magnetic resonance, radiographic texture analysis, as well as finite element analysis based on the above-mentioned imaging modalities. The performance of these techniques in predicting osteoporotic fracture and assessing strength indices are discussed.