Roy D. Bloebaum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roy D. Bloebaum has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Bettina M. Willie
Research Centre, Shriners Hospitals for Children-Canada , Montreal, QC H4A 0A9
9 shared publications Kent N. Bachus
University of Utah 1 , Department of Orthopaedics, Salt Lake City, UT 84108 , USA
5 shared publicationsDustin L. Williams
Bone and Joint Research Laboratory 151F, George E. Wahlen Department of Veterans Affairs, 500 Foothill Drive, Salt Lake City, UT, 84148, USA,
4 shared publications- Dustin L. Williams
Department of Orthopaedics, University of Utah, Salt Lake City, UT 84108, USA
4 shared publications John G. Skedros
Bone and Joint Research Laboratory, Department of Veterans Affairs (VA) Medical Center, Salt Lake City, Utah, USA
4 shared publications- Kent N. Bachus
Plastic and Orthopaedic Surgery Research Laboratory George E. Wahlen Department of Veterans Affairs Medical Center Salt Lake City Utah USA
4 shared publications
Latest Publications
- Open Access
- 15 July 2024
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 227 (14)
Roles of collagen cross-links and osteon collagen/lamellar morphotypes in equine third metacarpals in tension and compression tests
Many bones experience bending, placing one side in net compression and the other in net tension. Because bone mechanical properties are relatively reduced in tension compared with compression, adaptations are needed to reduce fracture risk. Several toughening mechanisms exist in bone, yet little is known of the influences of secondary osteon collagen/lamellar ‘morphotypes’ and potential interplay with intermolecular collagen cross-links (CCLs) in prevalent/predominant tension- and compression-loaded regions. Paired third metacarpals (MC3s) from 10 adult horses were prepared for mechanical testing. From one MC3/pair, 5 mm cubes were tested in compression at several mid-shaft locations. From contralateral bones, dumbbell-shaped specimens were tested in tension. Hence, habitual/natural tension- and compression-loaded regions were tested in both modes. Data included: elastic modulus, yield and ultimate strength, and energy absorption (toughness). Fragments of tested specimens were examined for predominant collagen fiber orientation (CFO; representing osteonal and non-osteonal bone), osteon morphotype score (MTS, representing osteonal CFO), mineralization, porosity and other histological characteristics. As a consequence of insufficient material from tension-tested specimens, CCLs were only examined in compression-tested specimens (HP, hydroxylysylpyridinoline; LP, lysylpyridinoline; PE, pentosidine). Among CCLs, only LP and HP/LP correlated significantly with mechanical parameters: LP with energy absorption, HP/LP with elastic modulus (both r=0.4). HP/LP showed a trend with energy absorption (r=−0.3, P=0.08). HP/LP more strongly correlated with osteon density and mineralization than CFO or MTS. Predominant CFO more strongly correlated with energy absorption than MTS in both testing modes. In general, CFO was found to be relatively prominent in affecting regional toughness in these equine MC3s in compression and tension.
- 15 July 2024
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 227 (14)
Open AccessRoles of collagen cross-links and osteon collagen/lamellar morphotypes in equine third metacarpals in tension and compression tests
Many bones experience bending, placing one side in net compression and the other in net tension. Because bone mechanical properties are relatively reduced in tension compared with compression, adaptations are needed to reduce fracture risk. Several toughening mechanisms exist in bone, yet little is known of the influences of secondary osteon collagen/lamellar ‘morphotypes’ and potential interplay with intermolecular collagen cross-links (CCLs) in prevalent/predominant tension- and compression-loaded regions. Paired third metacarpals (MC3s) from 10 adult horses were prepared for mechanical testing. From one MC3/pair, 5 mm cubes were tested in compression at several mid-shaft locations. From contralateral bones, dumbbell-shaped specimens were tested in tension. Hence, habitual/natural tension- and compression-loaded regions were tested in both modes. Data included: elastic modulus, yield and ultimate strength, and energy absorption (toughness). Fragments of tested specimens were examined for predominant collagen fiber orientation (CFO; representing osteonal and non-osteonal bone), osteon morphotype score (MTS, representing osteonal CFO), mineralization, porosity and other histological characteristics. As a consequence of insufficient material from tension-tested specimens, CCLs were only examined in compression-tested specimens (HP, hydroxylysylpyridinoline; LP, lysylpyridinoline; PE, pentosidine). Among CCLs, only LP and HP/LP correlated significantly with mechanical parameters: LP with energy absorption, HP/LP with elastic modulus (both r=0.4). HP/LP showed a trend with energy absorption (r=−0.3, P=0.08). HP/LP more strongly correlated with osteon density and mineralization than CFO or MTS. Predominant CFO more strongly correlated with energy absorption than MTS in both testing modes. In general, CFO was found to be relatively prominent in affecting regional toughness in these equine MC3s in compression and tension.
- Open Access
- 15 April 2023
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 567, 111495
Exploration of the synergistic role of cortical thickness asymmetry (“Trabecular Eccentricity” concept) in reducing fracture risk in the human femoral neck and a control bone (Artiodactyl Calcaneus)
- 15 April 2023
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 567, 111495
Open AccessExploration of the synergistic role of cortical thickness asymmetry (“Trabecular Eccentricity” concept) in reducing fracture risk in the human femoral neck and a control bone (Artiodactyl Calcaneus)
- 8 November 2018
- Published by Wiley in Journal of Anatomy
- Vol. 234 (1) , 66-82
Advancing the deer calcaneus model for bone adaptation studies:ex vivostrains obtained after transecting the tension members suggest an unrecognized important role for shear strains
Sheep and deer calcanei are finding increased use as models for studies of bone adaptation, including advancing understanding of how the strain (deformation) environment influences the ontogenetic emergence of biomechanically relevant structural and material variations in cortical and trabecular bone. These artiodactyl calcanei seem ideal for these analyses because they function like simply loaded short‐cantilevered beams with net compression and tension strains on the dorsal and plantar cortices, respectively. However, this habitual strain distribution requires more rigorous validation because it has been shown by limitedin vivoandex vivostrain measurements obtained during controlled ambulation (typically walking and trotting). The conception that these calcanei are relatively simply and habitually loaded ‘tension/compression bones’ could be invalid if infrequent, though biologically relevant, loads substantially change the location of the neutral axis (NA) that separates ‘compression’ and ‘tension’ regions. The effect on calcaneus strains of the tension members (plantar ligament and flexor tendon) is also not well understood and measuring strains after transecting them could reveal that they significantly modulate the strain distribution. We tested the hypothesis that the NA location previously described during simulated on‐axis loads of deer calcanei would exhibit limited variations even when load perturbations are unusual (e.g. off‐axis loads) or extreme (e.g. after transection of the tension members). We also examined regional differences in the predominance of the three strain modes (tension, compression, and shear) in these various load conditions in dorsal, plantar, medial, and lateral cortices. In addition to considering principal strains (tension and compression) and maximum shear strains, we also considered material‐axis (M‐A) shear strains. M‐A shear strains are those that are aligned along the long axis of the bone and are considered to have greater biomechanical relevance than maximum shear strains because failure theories of composite materials and bone are often based on stresses or strains in the principal material directions. We used the same load apparatus from our prior study of mule deer calcanei. Results showed that although the NA rotated up to 8° medially and 15° laterally during these off‐axis loads, it did not shift dramatically until after transection of all tension members. When comparing results based on maximum shear strain data vs. M‐A shear strain data, the dominant strain mode changed only in the plantar cortex – as expected (in accordance with oura prioriview) it was tension when M‐A shear strains were considered (shear : tension = 0.2) but changed to dominant shear when maximum shear strain data were considered (shear : tension = 1.3). This difference leads to different conclusions and speculations regarding which specific strain modes and magnitudes most strongly influence the emergence of the marked mineralization and histomorphological differences in the dorsal vs. plantar cortices. Consequently, our prior simplification of the deer calcaneus model as a simply loaded ‘tension/compression bone’ (i.e. plantar/dorsal) might be incorrect.In vivoand in finite element analyses are needed to determine whether describing it as a ‘shear‐tension/compression’ bone is more accurate. Addressing this question will help to advance the artiodactyl calcaneus as an experimental model for bone adaptation studies.
- 8 November 2018
- Published by Wiley in Journal of Anatomy
- Vol. 234 (1) , 66-82
Advancing the deer calcaneus model for bone adaptation studies:ex vivostrains obtained after transecting the tension members suggest an unrecognized important role for shear strains
Sheep and deer calcanei are finding increased use as models for studies of bone adaptation, including advancing understanding of how the strain (deformation) environment influences the ontogenetic emergence of biomechanically relevant structural and material variations in cortical and trabecular bone. These artiodactyl calcanei seem ideal for these analyses because they function like simply loaded short‐cantilevered beams with net compression and tension strains on the dorsal and plantar cortices, respectively. However, this habitual strain distribution requires more rigorous validation because it has been shown by limitedin vivoandex vivostrain measurements obtained during controlled ambulation (typically walking and trotting). The conception that these calcanei are relatively simply and habitually loaded ‘tension/compression bones’ could be invalid if infrequent, though biologically relevant, loads substantially change the location of the neutral axis (NA) that separates ‘compression’ and ‘tension’ regions. The effect on calcaneus strains of the tension members (plantar ligament and flexor tendon) is also not well understood and measuring strains after transecting them could reveal that they significantly modulate the strain distribution. We tested the hypothesis that the NA location previously described during simulated on‐axis loads of deer calcanei would exhibit limited variations even when load perturbations are unusual (e.g. off‐axis loads) or extreme (e.g. after transection of the tension members). We also examined regional differences in the predominance of the three strain modes (tension, compression, and shear) in these various load conditions in dorsal, plantar, medial, and lateral cortices. In addition to considering principal strains (tension and compression) and maximum shear strains, we also considered material‐axis (M‐A) shear strains. M‐A shear strains are those that are aligned along the long axis of the bone and are considered to have greater biomechanical relevance than maximum shear strains because failure theories of composite materials and bone are often based on stresses or strains in the principal material directions. We used the same load apparatus from our prior study of mule deer calcanei. Results showed that although the NA rotated up to 8° medially and 15° laterally during these off‐axis loads, it did not shift dramatically until after transection of all tension members. When comparing results based on maximum shear strain data vs. M‐A shear strain data, the dominant strain mode changed only in the plantar cortex – as expected (in accordance with oura prioriview) it was tension when M‐A shear strains were considered (shear : tension = 0.2) but changed to dominant shear when maximum shear strain data were considered (shear : tension = 1.3). This difference leads to different conclusions and speculations regarding which specific strain modes and magnitudes most strongly influence the emergence of the marked mineralization and histomorphological differences in the dorsal vs. plantar cortices. Consequently, our prior simplification of the deer calcaneus model as a simply loaded ‘tension/compression bone’ (i.e. plantar/dorsal) might be incorrect.In vivoand in finite element analyses are needed to determine whether describing it as a ‘shear‐tension/compression’ bone is more accurate. Addressing this question will help to advance the artiodactyl calcaneus as an experimental model for bone adaptation studies.
- 28 February 2017
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (2) , 578-588
Transcortical or intracondylar? Which model is accurate for predicting biomaterial attachment in total joint replacement?
Despite four decades of research on material and porous coatings intended for cementless fixation in total joint replacement (TJR), aseptic mechanical loosening unrelated to particulate disease remains a concern. One main question asked is how translational are the animal models used to screen material and porous coatings intended for TJR fixation? Another question is how specific are the translational models at targeting the cementless TJR components that have the highest loosening rates? The hypothesis tested was that the bone response would be different between the two bone types—cortical and cancellous—used in translational animal modeling. The osteoblastic jumping distance (OJD), percent ingrowth, and appositional bone response were measured to assess the response between cancellous and cortical bone at two different anatomical locations, within the same limb. With 500 µm inset, titanium porous coated implants and negative control dinosaur (coprolite) implants were investigated. The data demonstrated that cortical bone had 7 times OJD than cancellous bone. The bone ingrowth data demonstrated 16 times higher bone ingrowth than the cancellous bone. Light microscopy showed predominately fibrous tissue attachment (98%) in cancellous bone. Screening of materials intended for TJR require a translational model predictive of the clinical condition. The results demonstrated that the transcortical model rendered false-positive data. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017.
- 28 February 2017
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (2) , 578-588
Transcortical or intracondylar? Which model is accurate for predicting biomaterial attachment in total joint replacement?
Despite four decades of research on material and porous coatings intended for cementless fixation in total joint replacement (TJR), aseptic mechanical loosening unrelated to particulate disease remains a concern. One main question asked is how translational are the animal models used to screen material and porous coatings intended for TJR fixation? Another question is how specific are the translational models at targeting the cementless TJR components that have the highest loosening rates? The hypothesis tested was that the bone response would be different between the two bone types—cortical and cancellous—used in translational animal modeling. The osteoblastic jumping distance (OJD), percent ingrowth, and appositional bone response were measured to assess the response between cancellous and cortical bone at two different anatomical locations, within the same limb. With 500 µm inset, titanium porous coated implants and negative control dinosaur (coprolite) implants were investigated. The data demonstrated that cortical bone had 7 times OJD than cancellous bone. The bone ingrowth data demonstrated 16 times higher bone ingrowth than the cancellous bone. Light microscopy showed predominately fibrous tissue attachment (98%) in cancellous bone. Screening of materials intended for TJR require a translational model predictive of the clinical condition. The results demonstrated that the transcortical model rendered false-positive data. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017.
- 18 August 2016
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (11) , 2543
Letter to the Editor: Editorial: The Graying of the (Funded) Musculoskeletal Scientist
- 18 August 2016
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 474 (11) , 2543
Letter to the Editor: Editorial: The Graying of the (Funded) Musculoskeletal Scientist
- 1 March 2015
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 473 (3) , 928-935
Does Vitamin E-blended UHMWPE Prevent Biofilm Formation?
Biofilm-related periprosthetic infections are catastrophic to patients and clinicians. Data suggest the addition of vitamin E to UHMWPE may have the ability to reduce biofilm formation on the surface of UHMWPE; however, previous studies were performed using stagnant broth solutions that may not have simulated a physiologic environment. In addition, the observed differences in levels of bacterial attachment, though statistically significant, may not be clinically significant. We blended vitamin E with UHMWPE material and tested it for the ability to resist biofilm formation using a clinical isolate of methicillin-resistant Staphylococcus aureus (MRSA). Three additional materials were tested for comparison: highly crosslinked UHMWPE, compression-molded UHMWPE, and polyetheretherketone. We also determined whether the surface roughness of these materials facilitated biofilm formation. Using a flow cell system, samples of each material type were placed into separate chambers. A 10% solution of brain-heart infusion broth containing 105 colony-forming units (CFUs)/mL was flowed through the flow cell over 48 hours. The number of bacteria that adhered to the surface was quantified and biofilm formation was observed qualitatively using scanning electron microscopy. Optical profilometry was used to determine the surface roughness of each material type. Vitamin E-blended UHMWPE did not reduce biofilm formation of a clinically relevant strain of MRSA compared to materials that did not have vitamin E. More specifically, vitamin E-blended materials had similar amounts of biofilm formation (~ 8 log10 CFUs/cm2) compared to materials not containing vitamin E (~ 8.1 log10 CFUs/cm2) (p > 0.4). The roughness of vitamin E-blended material surfaces (mean ± SD: 1.85 ± 0.46 µm) compared to that of materials without vitamin E (2.06 ± 1.24 µm) did not appear to influence biofilm formation. Under physiologically relevant conditions, vitamin E-blended UHMWPE did not have the ability to reduce the formation of biofilms by MRSA. These data indicate that the addition of vitamin E to UHMWPE may not reduce clinically relevant rates of biofilm-related periprosthetic infections of total joint arthroplasty devices.
- 1 March 2015
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 473 (3) , 928-935
Does Vitamin E-blended UHMWPE Prevent Biofilm Formation?
Biofilm-related periprosthetic infections are catastrophic to patients and clinicians. Data suggest the addition of vitamin E to UHMWPE may have the ability to reduce biofilm formation on the surface of UHMWPE; however, previous studies were performed using stagnant broth solutions that may not have simulated a physiologic environment. In addition, the observed differences in levels of bacterial attachment, though statistically significant, may not be clinically significant. We blended vitamin E with UHMWPE material and tested it for the ability to resist biofilm formation using a clinical isolate of methicillin-resistant Staphylococcus aureus (MRSA). Three additional materials were tested for comparison: highly crosslinked UHMWPE, compression-molded UHMWPE, and polyetheretherketone. We also determined whether the surface roughness of these materials facilitated biofilm formation. Using a flow cell system, samples of each material type were placed into separate chambers. A 10% solution of brain-heart infusion broth containing 105 colony-forming units (CFUs)/mL was flowed through the flow cell over 48 hours. The number of bacteria that adhered to the surface was quantified and biofilm formation was observed qualitatively using scanning electron microscopy. Optical profilometry was used to determine the surface roughness of each material type. Vitamin E-blended UHMWPE did not reduce biofilm formation of a clinically relevant strain of MRSA compared to materials that did not have vitamin E. More specifically, vitamin E-blended materials had similar amounts of biofilm formation (~ 8 log10 CFUs/cm2) compared to materials not containing vitamin E (~ 8.1 log10 CFUs/cm2) (p > 0.4). The roughness of vitamin E-blended material surfaces (mean ± SD: 1.85 ± 0.46 µm) compared to that of materials without vitamin E (2.06 ± 1.24 µm) did not appear to influence biofilm formation. Under physiologically relevant conditions, vitamin E-blended UHMWPE did not have the ability to reduce the formation of biofilms by MRSA. These data indicate that the addition of vitamin E to UHMWPE may not reduce clinically relevant rates of biofilm-related periprosthetic infections of total joint arthroplasty devices.
- 1 October 2014
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (10) , 2966-2977
Radiographic Evaluation of Bone Adaptation Adjacent to Percutaneous Osseointegrated Prostheses in a Sheep Model
Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.
- 1 October 2014
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (10) , 2966-2977
Radiographic Evaluation of Bone Adaptation Adjacent to Percutaneous Osseointegrated Prostheses in a Sheep Model
Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.
- 1 October 2014
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (10) , 2957-2965
Progression of Bone Ingrowth and Attachment Strength for Stability of Percutaneous Osseointegrated Prostheses
Percutaneous osseointegrated prosthetic (POP) devices have been used clinically in Europe for decades. Unfortunately, their introduction into the United States has been delayed, in part due to the lack of data documenting the progression of osseointegration and mechanical stability. We determined the progression of bone ingrowth into porous-coated POP devices and established the interrelationship with mechanical stability. After amputation, 64 skeletally mature sheep received a custom porous-coated POP device and were then randomized into five time groups, with subsequent measurement of percentage of bone ingrowth into the available pore spaces (n = 32) and the mechanical pullout force (n = 32). Postimplantation, there was an accelerated progression of bone ingrowth (~48% from 0 to 3 months) producing a mean pullout force of 5066 ± 1543 N. Subsequently, there was a slower but continued progression of bone ingrowth (~23% from 3 to 12 months) culminating with a mean pullout force of 13,485 ± 1855 N at 12 months postimplantation. There was a high linear correlation (R = 0.94) between the bone ingrowth and mechanical pullout stability. This weightbearing model shows an accelerated progression of bone ingrowth into the porous coating; the amount of ingrowth observed at 3 months after surgery within the porous-coated POP devices was sufficient to generate mechanical stability. The data document progression of bone ingrowth into porous-coated POP devices and establish a strong interrelationship between ingrowth and pullout strength. Further human data are needed to validate these findings.
- 1 October 2014
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (10) , 2957-2965
Progression of Bone Ingrowth and Attachment Strength for Stability of Percutaneous Osseointegrated Prostheses
Percutaneous osseointegrated prosthetic (POP) devices have been used clinically in Europe for decades. Unfortunately, their introduction into the United States has been delayed, in part due to the lack of data documenting the progression of osseointegration and mechanical stability. We determined the progression of bone ingrowth into porous-coated POP devices and established the interrelationship with mechanical stability. After amputation, 64 skeletally mature sheep received a custom porous-coated POP device and were then randomized into five time groups, with subsequent measurement of percentage of bone ingrowth into the available pore spaces (n = 32) and the mechanical pullout force (n = 32). Postimplantation, there was an accelerated progression of bone ingrowth (~48% from 0 to 3 months) producing a mean pullout force of 5066 ± 1543 N. Subsequently, there was a slower but continued progression of bone ingrowth (~23% from 3 to 12 months) culminating with a mean pullout force of 13,485 ± 1855 N at 12 months postimplantation. There was a high linear correlation (R = 0.94) between the bone ingrowth and mechanical pullout stability. This weightbearing model shows an accelerated progression of bone ingrowth into the porous coating; the amount of ingrowth observed at 3 months after surgery within the porous-coated POP devices was sufficient to generate mechanical stability. The data document progression of bone ingrowth into porous-coated POP devices and establish a strong interrelationship between ingrowth and pullout strength. Further human data are needed to validate these findings.
- Open Access
- 12 March 2013
- Published by Wiley in The Anatomical Record
- Vol. 296 (5) , 736-744
The Significance of Calcified Fibrocartilage on the Cortical Endplate of the Translational Sheep Spine Model
To gain an understanding of the vertebral cortical endplate and factors that may affect the ability to achieve skeletal attachment to intervertebral implants and fusion, this study aimed to characterize the hypermineralized tissue on the cortical endplate of the vertebral body on a commonly used animal model. Skeletally mature sheep were injected with tetracycline prior to euthanasia and the C2‐C3, T5‐T6, and L2‐L3 spinal motion segments were excised and prepared. Vertebral tissues were imaged using backscatter electron (BSE) imaging, histology, and tetracycline labeling was used to assess bone remodeling within different tissue layers. It was determined that the hypermineralized tissue layer was calcified fibrocartilage (CFC). No tetracycline labels were identified in the CFC layer, in contrast to single and double labels that were present in the underlying bone, indicating the CFC present on the cortical endplate was not being actively remodeled. The average thickness of the CFC layer was 146.3 ± 70.53 µm in the cervical region, 98.2 ± 40.29 µm in the thoracic region, and 150.89 ± 69.25 µm in the lumbar region. This difference in thickness may be attributed to the regional biomechanical properties of the spine. Results from this investigation indicate the presence of a nonremodeling tissue on the cortical endplate of the vertebral body in sheep spines, which attaches the intervertebral disc to the vertebrae. This tissue, if not removed, would likely prevent successful bony attachment to an intervertebral device in spinal fusion studies and total disc replacement surgeries. Anat Rec, 296:736–744, 2013.
- 12 March 2013
- Published by Wiley in The Anatomical Record
- Vol. 296 (5) , 736-744
Open AccessThe Significance of Calcified Fibrocartilage on the Cortical Endplate of the Translational Sheep Spine Model
To gain an understanding of the vertebral cortical endplate and factors that may affect the ability to achieve skeletal attachment to intervertebral implants and fusion, this study aimed to characterize the hypermineralized tissue on the cortical endplate of the vertebral body on a commonly used animal model. Skeletally mature sheep were injected with tetracycline prior to euthanasia and the C2‐C3, T5‐T6, and L2‐L3 spinal motion segments were excised and prepared. Vertebral tissues were imaged using backscatter electron (BSE) imaging, histology, and tetracycline labeling was used to assess bone remodeling within different tissue layers. It was determined that the hypermineralized tissue layer was calcified fibrocartilage (CFC). No tetracycline labels were identified in the CFC layer, in contrast to single and double labels that were present in the underlying bone, indicating the CFC present on the cortical endplate was not being actively remodeled. The average thickness of the CFC layer was 146.3 ± 70.53 µm in the cervical region, 98.2 ± 40.29 µm in the thoracic region, and 150.89 ± 69.25 µm in the lumbar region. This difference in thickness may be attributed to the regional biomechanical properties of the spine. Results from this investigation indicate the presence of a nonremodeling tissue on the cortical endplate of the vertebral body in sheep spines, which attaches the intervertebral disc to the vertebrae. This tissue, if not removed, would likely prevent successful bony attachment to an intervertebral device in spinal fusion studies and total disc replacement surgeries. Anat Rec, 296:736–744, 2013.