Kenneth J. Nichols
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenneth J. Nichols has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Christopher J. Palestro
Division of Nuclear Medicine and Molecular Imaging, North Shore-Long Island Jewish Health System, Manhasset and New Hyde Park, USA
11 shared publicationsAndrew Van Tosh
St. Francis Hospital
9 shared publicationsNathaniel Reichek
Research Department, Division of Cardiovascular Research, St. Francis Hospital-The Heart Center, Roslyn, USA
8 shared publicationsYi Wang
St. Francis Hospital
5 shared publicationsGene G. Tronco
3 shared publicationsMaria B. Tomas
3 shared publications
Latest Publications
- 1 January 2018
- Published by The Japanese Society of Nuclear Cardiology in Annals of Nuclear Cardiology
- Vol. 4 (1) , 149-150
Safe Handling of Nuclear Cardiology Radioactive Shipments
Shipments of radioactive sources to Nuclear Cardiology facilities must be handled properly to avoid unintended radioactive contamination. Appropriate personnel must be involved in the ordering, receiving, surveying, and opening of radioactive shipments, and must record relevant information for each package. Action limits defining radioactive contamination include a wipe test result indicating removable activity from the exterior of a package exceeding 185 Bq (0.005 μCi) above background radiation levels for a surveyed area of 100 cm2, or exposure meter readings exceeding 0.1 mSv/hr (10 mrem/hr) 1 meter from a package, or exposure rate readings at the package surface exceeding 2 mSv/hr (200 mrem/hr). Following standardized procedures will ensure personnel of Nuclear Cardiology facilities that shipments of radioactivity are handled properly and safely.
- 1 January 2018
- Published by The Japanese Society of Nuclear Cardiology in Annals of Nuclear Cardiology
- Vol. 4 (1) , 149-150
Safe Handling of Nuclear Cardiology Radioactive Shipments
Shipments of radioactive sources to Nuclear Cardiology facilities must be handled properly to avoid unintended radioactive contamination. Appropriate personnel must be involved in the ordering, receiving, surveying, and opening of radioactive shipments, and must record relevant information for each package. Action limits defining radioactive contamination include a wipe test result indicating removable activity from the exterior of a package exceeding 185 Bq (0.005 μCi) above background radiation levels for a surveyed area of 100 cm2, or exposure meter readings exceeding 0.1 mSv/hr (10 mrem/hr) 1 meter from a package, or exposure rate readings at the package surface exceeding 2 mSv/hr (200 mrem/hr). Following standardized procedures will ensure personnel of Nuclear Cardiology facilities that shipments of radioactivity are handled properly and safely.
- 1 October 2014
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 21 (5) , 954-957
Utility of reprojected tomograms
- 1 October 2014
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 21 (5) , 954-957
Utility of reprojected tomograms
- 4 October 2013
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 20 (6) , 1060-1068
The relationship between ischemia-induced left ventricular dysfunction, coronary flow reserve, and coronary steal on regadenoson stress-gated 82Rb PET myocardial perfusion imaging
- 4 October 2013
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 20 (6) , 1060-1068
The relationship between ischemia-induced left ventricular dysfunction, coronary flow reserve, and coronary steal on regadenoson stress-gated 82Rb PET myocardial perfusion imaging
- 1 June 2013
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 20 (3) , 329-330
The motivation to reproject gated blood pool SPECT data as planar data
- 1 June 2013
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 20 (3) , 329-330
The motivation to reproject gated blood pool SPECT data as planar data
- 1 February 2013
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 34 (2) , 140-145
Comparison of criteria to truncate gastric emptying tests
Standardized scintigraphic gastric emptying (GE) protocols to detect gastroparesis (GP) require collecting data for 4 h. This investigation was undertaken to compare seven methods to reduce the duration of the test. This was a retrospective study of GE data collected using a standardized protocol at 0, 1, 2, 3, and 4 h for 602 patients being evaluated for GP. The reference standard was GP defined conventionally as percentage of gastric retention (GR) at 4 h (p4) of greater than 10%. For data up to 2 h the results were derived as follows: (a) confirming as being positive for GP if GR at 2 h was greater than 65%, negative for GP if GR at 2 h was less than 45%, and indeterminate otherwise; (b) by linear extrapolation; and (c) by monoexponential extrapolation. For data beyond 2 h, further evaluations were made and results were derived as follows: (a) confirming as being positive for GP if GR at 2.5 h was greater than 40%; (b) ascertainment of GR at 3 h; (c) by biphasic fit; and (d) by observation of maximum GR for normal patients at time points earlier than 4 h. Thirty percent of all patients had GP. Eighty percent were determinate by Method 1; for these patients sensitivity to detect GP was similar (P=0.11) for Methods 1-3 (69-79%). For data beyond 2 h, sensitivity of the seven methods ranged from 64 to 92%, and the sensitivity of every method was significantly lower than that of the reference standard (P<0.001). Considering that sensitivity to detect GP was significantly reduced for data collection limited to 3 h or less, it is not advisable to truncate GE studies earlier than 4 h.
- 1 February 2013
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 34 (2) , 140-145
Comparison of criteria to truncate gastric emptying tests
Standardized scintigraphic gastric emptying (GE) protocols to detect gastroparesis (GP) require collecting data for 4 h. This investigation was undertaken to compare seven methods to reduce the duration of the test. This was a retrospective study of GE data collected using a standardized protocol at 0, 1, 2, 3, and 4 h for 602 patients being evaluated for GP. The reference standard was GP defined conventionally as percentage of gastric retention (GR) at 4 h (p4) of greater than 10%. For data up to 2 h the results were derived as follows: (a) confirming as being positive for GP if GR at 2 h was greater than 65%, negative for GP if GR at 2 h was less than 45%, and indeterminate otherwise; (b) by linear extrapolation; and (c) by monoexponential extrapolation. For data beyond 2 h, further evaluations were made and results were derived as follows: (a) confirming as being positive for GP if GR at 2.5 h was greater than 40%; (b) ascertainment of GR at 3 h; (c) by biphasic fit; and (d) by observation of maximum GR for normal patients at time points earlier than 4 h. Thirty percent of all patients had GP. Eighty percent were determinate by Method 1; for these patients sensitivity to detect GP was similar (P=0.11) for Methods 1-3 (69-79%). For data beyond 2 h, sensitivity of the seven methods ranged from 64 to 92%, and the sensitivity of every method was significantly lower than that of the reference standard (P<0.001). Considering that sensitivity to detect GP was significantly reduced for data collection limited to 3 h or less, it is not advisable to truncate GE studies earlier than 4 h.
- 26 November 2010
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 27 (7) , 1095-1104
Correspondence between gated SPECT and cardiac magnetic resonance quantified myocardial wall thickening
Left ventricular (LV) wall thickening (WT) assessed from myocardial perfusion (MP) gated SPECT data has been reported to be a marker of functional recovery following myocardial damage. However, the accuracy of WT measurements obtained in the clinical setting rarely has been validated against an independent quantitative reference standard. The purpose of this investigation was to assess the degree to which quantified MP WT agrees with cardiac magnetic resonance (CMR) WT measurements, and to determine whether quantitation is as accurate as visual analysis in detecting abnormal regional WT. MP and ECG-gated True-FISP CMR data were analyzed for 20 patients evaluated after myocardial infarction (age 60 ± 11 years; 95% males). An experienced observer visually graded MP WT on a 5-point scale while viewing MP cines. MP WT was quantified using “Emory Cardiac Toolbox” (ECTb) algorithms. MP algorithms isolated myocardial counts and generated polar maps of WT. CMR data were analyzed by Medis “MASS” software. Manually drawn endocardial and epicardial contours were used to compute WT on CMR. CMR data also were processed for 10 age-matched normal volunteers to define the CMR WT threshold of abnormality. All computations were sampled into conventional 17 ACC/AHA LV wall segments. Receiver operating characteristics (ROC) curve analysis provided discrimination thresholds for optimal accuracy, which subsequently were used to dichotomize the MP methods. WT abnormalities also were assessed for the 3 major arterial territories, and for total numbers of abnormal segments per patient. 25% of all segments had abnormally low WT by CMR. While MP quantitation underestimated CMR WT values for segments with normal WT (26 ± 13% vs. 56 ± 28%, P < 0.0001), measurements were similar for segments with abnormal WT (4 ± 12% vs. 5 ± 9%, P = 0.45). On a segment-by-segment basis, detection of abnormal WT was more accurate by quantitative than visual analysis both for continuous variables (ROC area = 88 ± 2% vs. 80 ± 3%, P < 0.0001) and for dichotomized methods (83% vs. 76%, P = 0.04). Agreement of MP versus CMR for discriminating segments with normal from abnormal WT was significantly better for quantitative than visual analysis (κ = 0.59 vs. 0.40, P < 0.0001), with strongest agreement for left anterior descending artery territories (κ = 0.72). Total numbers of segments with abnormal WT per patient demonstrated significant correlation with CMR (r = 0.83, P < 0.0001). MP quantified LV ejection fractions and volumes also correlated well with CMR (r = 0.87 and 0.90, respectively). Quantified MP WT measurements correlated significantly with CMR values, and discriminated segments with abnormal WT from segments with normal WT more accurately than visual analysis. Therefore, quantification should be performed when analyzing regional WT by scintigraphy.
- 26 November 2010
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 27 (7) , 1095-1104
Correspondence between gated SPECT and cardiac magnetic resonance quantified myocardial wall thickening
Left ventricular (LV) wall thickening (WT) assessed from myocardial perfusion (MP) gated SPECT data has been reported to be a marker of functional recovery following myocardial damage. However, the accuracy of WT measurements obtained in the clinical setting rarely has been validated against an independent quantitative reference standard. The purpose of this investigation was to assess the degree to which quantified MP WT agrees with cardiac magnetic resonance (CMR) WT measurements, and to determine whether quantitation is as accurate as visual analysis in detecting abnormal regional WT. MP and ECG-gated True-FISP CMR data were analyzed for 20 patients evaluated after myocardial infarction (age 60 ± 11 years; 95% males). An experienced observer visually graded MP WT on a 5-point scale while viewing MP cines. MP WT was quantified using “Emory Cardiac Toolbox” (ECTb) algorithms. MP algorithms isolated myocardial counts and generated polar maps of WT. CMR data were analyzed by Medis “MASS” software. Manually drawn endocardial and epicardial contours were used to compute WT on CMR. CMR data also were processed for 10 age-matched normal volunteers to define the CMR WT threshold of abnormality. All computations were sampled into conventional 17 ACC/AHA LV wall segments. Receiver operating characteristics (ROC) curve analysis provided discrimination thresholds for optimal accuracy, which subsequently were used to dichotomize the MP methods. WT abnormalities also were assessed for the 3 major arterial territories, and for total numbers of abnormal segments per patient. 25% of all segments had abnormally low WT by CMR. While MP quantitation underestimated CMR WT values for segments with normal WT (26 ± 13% vs. 56 ± 28%, P < 0.0001), measurements were similar for segments with abnormal WT (4 ± 12% vs. 5 ± 9%, P = 0.45). On a segment-by-segment basis, detection of abnormal WT was more accurate by quantitative than visual analysis both for continuous variables (ROC area = 88 ± 2% vs. 80 ± 3%, P < 0.0001) and for dichotomized methods (83% vs. 76%, P = 0.04). Agreement of MP versus CMR for discriminating segments with normal from abnormal WT was significantly better for quantitative than visual analysis (κ = 0.59 vs. 0.40, P < 0.0001), with strongest agreement for left anterior descending artery territories (κ = 0.72). Total numbers of segments with abnormal WT per patient demonstrated significant correlation with CMR (r = 0.83, P < 0.0001). MP quantified LV ejection fractions and volumes also correlated well with CMR (r = 0.87 and 0.90, respectively). Quantified MP WT measurements correlated significantly with CMR values, and discriminated segments with abnormal WT from segments with normal WT more accurately than visual analysis. Therefore, quantification should be performed when analyzing regional WT by scintigraphy.
- 1 October 2010
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 31 (10) , 881-888
Automated detection of left ventricular dyskinesis by gated blood pool SPECT
Obejctive The ability to detect left ventricular (LV) apical dyskinesis, the hallmark of an aneurysm, is an important requirement of diagnostic cardiac imaging modalities that perform wall motion analysis. Our investigation assessed the ability of gated blood pool single-photon emission-computed tomography (GBPS) to automatically detect LV dyskinesis, using cardiac magnetic resonance (CMR) as the reference standard. Materials and methods GBPS data were analyzed for 41 patients with congestive heart failure or cardiomyopathy and compared with ECG-gated TrueFISP CMR evaluations. An experienced nuclear cardiologist without the knowledge of quantitative GBPS or CMR results graded visual impressions of regional wall motion while examining cinematic playbacks of GBPS images. GBPS algorithms automatically isolated LV counts and computed regional phase (ϕ) values in each of 17 conventional American Heart Association LV segments. LV asynchrony was quantified by the two local measures: maximum apical ϕ difference (Δα), and standard deviation among apical phases (σα), and by the five global measures: ϕ histogram bandwidth (BWHistogram), ϕ histogram standard deviation (σHistogram), Z-scores, Entropy, and Synchrony. For CMR data, an expert manually drew endocardial LV outlines to measure regional wall motion in 17 LV segments. Results Apical dyskinesis was present in nine patients. Among GBPS measurements, the method with the greatest accuracy for detecting dyskinesis was Δα (receiver operating characteristic area=95%). The only method with a sufficiently high κ statistic to represent ‘very good agreement’ with CMR was Δα, with κ=0.81. Δα was more sensitive in detecting dyskinesis than visual analysis (100 vs. 33%, P=0.01). Conclusion Automatic GBPS computations accurately identified patients with LV dyskinesis, and detected dyskinesis more successfully than did visual analysis.
- 1 October 2010
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 31 (10) , 881-888
Automated detection of left ventricular dyskinesis by gated blood pool SPECT
Obejctive The ability to detect left ventricular (LV) apical dyskinesis, the hallmark of an aneurysm, is an important requirement of diagnostic cardiac imaging modalities that perform wall motion analysis. Our investigation assessed the ability of gated blood pool single-photon emission-computed tomography (GBPS) to automatically detect LV dyskinesis, using cardiac magnetic resonance (CMR) as the reference standard. Materials and methods GBPS data were analyzed for 41 patients with congestive heart failure or cardiomyopathy and compared with ECG-gated TrueFISP CMR evaluations. An experienced nuclear cardiologist without the knowledge of quantitative GBPS or CMR results graded visual impressions of regional wall motion while examining cinematic playbacks of GBPS images. GBPS algorithms automatically isolated LV counts and computed regional phase (ϕ) values in each of 17 conventional American Heart Association LV segments. LV asynchrony was quantified by the two local measures: maximum apical ϕ difference (Δα), and standard deviation among apical phases (σα), and by the five global measures: ϕ histogram bandwidth (BWHistogram), ϕ histogram standard deviation (σHistogram), Z-scores, Entropy, and Synchrony. For CMR data, an expert manually drew endocardial LV outlines to measure regional wall motion in 17 LV segments. Results Apical dyskinesis was present in nine patients. Among GBPS measurements, the method with the greatest accuracy for detecting dyskinesis was Δα (receiver operating characteristic area=95%). The only method with a sufficiently high κ statistic to represent ‘very good agreement’ with CMR was Δα, with κ=0.81. Δα was more sensitive in detecting dyskinesis than visual analysis (100 vs. 33%, P=0.01). Conclusion Automatic GBPS computations accurately identified patients with LV dyskinesis, and detected dyskinesis more successfully than did visual analysis.
- 1 October 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (5) , 691-696
Prospects for advancing nuclear cardiology by means of new detector designs
- 1 October 2009
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 16 (5) , 691-696
Prospects for advancing nuclear cardiology by means of new detector designs
- 1 April 2009
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 30 (4) , 292-299
Relationships between blood pool and myocardial perfusion-gated SPECT global and regional left ventricular function measurements
Algorithms have been developed to quantify global and regional left ventricular (LV) function and asynchrony from myocardial perfusion (MP) and blood pool (BP)-gated single-photon emission computer-assisted tomography, but relationships between measurements from these two imaging modalities have not been documented. The objective of this investigation was to determine the degree to which automated BP and MP measurements agree with each other and are accurate, using cardiac magnetic resonance (CMR) as the reference standard. We also sought to determine the extent to which regions of abnormal phase correspond to segments exhibiting abnormal wall motion. We studied 20 patients with prior myocardial infarction (age 60±11 years; 95% males) who had BP, MP, and ECG-gated CMR data acquisitions. MP and BP measured parameters included global ejection fraction (EF) and volumes, regional contraction phases, and standard deviations and bandwidths of phase versus R-R histograms. CMR algorithms used manually drawn endocardial and epicardial contours to measure global and regional wall motion and wall thickening. Regional measurements were resampled for all three imaging modalities into 17 conventional LV territories. BP LV counts significantly exceeded MP counts with a ratio of 5.2 : 1. There were no differences among the three methods for global EFs or volumes (analysis of variance P = 0.86 and 0.94). MP and BP correlated equally well (P = 0.15) versus CMR for global EFs (MP: r=0.87 and BP: r=0.95) and volumes (r=0.91 for both). Phase histogram parameters correlated significantly for MP versus BP for phase standard deviation (r=0.79) and phase bandwidth (r=0.93). Detection of five patients with significantly extended phase bandwidth, indicative of asynchrony, showed ‘good agreement’ between MP and BP (κ=0.73; McNemar's difference=0%, P=0.48). Abnormal regional BP EF predicted abnormal wall motion of specific LV segments (receiver-operating characteristic area=85±2%), and abnormal regional MP wall thickening predicted abnormal CMR wall thickening (receiver-operating characteristic area=87±3%). Abnormal MP phase was present in 25% of 67 dyssynergic segments and 64% of segments adjacent to dyssynergic segments, indicating that locations of phase abnormalities were more widely distributed in the LV than sites of depressed wall motion. MP and BP measures of LV global and regional function agreed well with each other and with independent CMR measurements. MP and BP phase measurements suggested that phase abnormalities were more widespread than localized wall motion abnormalities.
- 1 April 2009
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 30 (4) , 292-299
Relationships between blood pool and myocardial perfusion-gated SPECT global and regional left ventricular function measurements
Algorithms have been developed to quantify global and regional left ventricular (LV) function and asynchrony from myocardial perfusion (MP) and blood pool (BP)-gated single-photon emission computer-assisted tomography, but relationships between measurements from these two imaging modalities have not been documented. The objective of this investigation was to determine the degree to which automated BP and MP measurements agree with each other and are accurate, using cardiac magnetic resonance (CMR) as the reference standard. We also sought to determine the extent to which regions of abnormal phase correspond to segments exhibiting abnormal wall motion. We studied 20 patients with prior myocardial infarction (age 60±11 years; 95% males) who had BP, MP, and ECG-gated CMR data acquisitions. MP and BP measured parameters included global ejection fraction (EF) and volumes, regional contraction phases, and standard deviations and bandwidths of phase versus R-R histograms. CMR algorithms used manually drawn endocardial and epicardial contours to measure global and regional wall motion and wall thickening. Regional measurements were resampled for all three imaging modalities into 17 conventional LV territories. BP LV counts significantly exceeded MP counts with a ratio of 5.2 : 1. There were no differences among the three methods for global EFs or volumes (analysis of variance P = 0.86 and 0.94). MP and BP correlated equally well (P = 0.15) versus CMR for global EFs (MP: r=0.87 and BP: r=0.95) and volumes (r=0.91 for both). Phase histogram parameters correlated significantly for MP versus BP for phase standard deviation (r=0.79) and phase bandwidth (r=0.93). Detection of five patients with significantly extended phase bandwidth, indicative of asynchrony, showed ‘good agreement’ between MP and BP (κ=0.73; McNemar's difference=0%, P=0.48). Abnormal regional BP EF predicted abnormal wall motion of specific LV segments (receiver-operating characteristic area=85±2%), and abnormal regional MP wall thickening predicted abnormal CMR wall thickening (receiver-operating characteristic area=87±3%). Abnormal MP phase was present in 25% of 67 dyssynergic segments and 64% of segments adjacent to dyssynergic segments, indicating that locations of phase abnormalities were more widely distributed in the LV than sites of depressed wall motion. MP and BP measures of LV global and regional function agreed well with each other and with independent CMR measurements. MP and BP phase measurements suggested that phase abnormalities were more widespread than localized wall motion abnormalities.
- 19 March 2009
- Published by Wiley in Medical Physics
- Vol. 36 (4) , 1251-1257
Automated versus manual detection of left ventricular wall motion abnormalities by gated blood pool SPECT
The purpose of this investigation was to describe the rationale and implementation of new totally automated algorithms to compute global and regional left ventricular (LV) function measurements from blood pool (BP) gated SPECT data and to test the hypothesis that automated calculations are as accurate as manual calculations for detecting global and regional LV wall motion abnormalities when compared to independent cardiac magnetic resonance (CMR) measurements. From an Institutional Review Board approved retrospective review of data for 43 patients (age 58 +/- 13 years; 82% males; 59% with CHF; 59% with prior MI) evaluated for cardiac disease, CMR data were analyzed along with automated and manual calculations of BP data. There was no difference among global LV EF values (ANOVA p = 0.90) and strong correlation between automated (r = 0.96, p < 0.0001) and manual (r = 0.95, p < 0.0001) global LV EFs versus CMR, with no significant trends or biases. There was "very good agreement" of automated (kappa = 0.91) and manual (kappa = 0.86) discriminations of cases with LV EF < 50% versus CMR. Detection of LV segments with abnormal regional wall motion was equally accurate (p = 0.68) for automated and manual processings of BP data [ROC areas = 87(+/- 2%) versus 86(+/- 2%)]. The authors conclude that automated and manual computations were equivalent to each other and accurate at identifying both global and regional LV wall motion abnormalities.
- 19 March 2009
- Published by Wiley in Medical Physics
- Vol. 36 (4) , 1251-1257
Automated versus manual detection of left ventricular wall motion abnormalities by gated blood pool SPECT
The purpose of this investigation was to describe the rationale and implementation of new totally automated algorithms to compute global and regional left ventricular (LV) function measurements from blood pool (BP) gated SPECT data and to test the hypothesis that automated calculations are as accurate as manual calculations for detecting global and regional LV wall motion abnormalities when compared to independent cardiac magnetic resonance (CMR) measurements. From an Institutional Review Board approved retrospective review of data for 43 patients (age 58 +/- 13 years; 82% males; 59% with CHF; 59% with prior MI) evaluated for cardiac disease, CMR data were analyzed along with automated and manual calculations of BP data. There was no difference among global LV EF values (ANOVA p = 0.90) and strong correlation between automated (r = 0.96, p < 0.0001) and manual (r = 0.95, p < 0.0001) global LV EFs versus CMR, with no significant trends or biases. There was "very good agreement" of automated (kappa = 0.91) and manual (kappa = 0.86) discriminations of cases with LV EF < 50% versus CMR. Detection of LV segments with abnormal regional wall motion was equally accurate (p = 0.68) for automated and manual processings of BP data [ROC areas = 87(+/- 2%) versus 86(+/- 2%)]. The authors conclude that automated and manual computations were equivalent to each other and accurate at identifying both global and regional LV wall motion abnormalities.