Jacob Geleijns
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jacob Geleijns has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- J. Zoetelief
Delft University of Technology, IRI, Mekelweg 15, 2629 JB Delft, the Netherlands
4 shared publications D Zweers
3 shared publications- Marçal Salvado
Medical Physics Unit, Universitat Rovira i Virgili Facultat de Medicina I Ciences de la Salut, Reus, Tarragona, SPAIN
3 shared publications W Veldkamp
3 shared publicationsA. Calzado
2 shared publications- Albert de Roos
From the Department of Radiology, Leiden University Medical Center, Albinusdreef 2, Leiden 2333 ZA, the Netherlands
2 shared publications
Latest Publications
- 1 January 2014
- Published by Elsevier in Physica Medica
- Vol. 30, e18-e19
Model observers low contrast detectability performance at different kV levels in CT phantom images
- 1 January 2014
- Published by Elsevier in Physica Medica
- Vol. 30, e18-e19
Model observers low contrast detectability performance at different kV levels in CT phantom images
- Open Access
- 22 September 2012
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 29 (2) , 453-461
Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography
- 22 September 2012
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 29 (2) , 453-461
Open AccessEffect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography
- Open Access
- 3 May 2012
- Published by Springer Nature in Insights into Imaging
- Vol. 3 (3) , 197-200
Core curriculum for medical physicists in radiology. Recommendations from an EFOMP/ESR working group
Some years ago it was decided that a European curriculum should be developed for medical physicists professionally engaged in the support of clinical diagnostic imaging departments. With this in mind, EFOMP (European Federation of Organisations for Medical Physics) in association with ESR (European Society of Radiology) nominated an expert working group. This curriculum is now to hand. The curriculum is intended to promote best patient care in radiology departments through the harmonization of education and training of medical physicists to a high standard in diagnostic radiology. It is recommended that a medical physicist working in a radiology department should have an advanced level of professional expertise in X-ray imaging, and additionally, depending on local availability, should acquire knowledge and competencies in overseeing ultrasound imaging, nuclear medicine, and MRI technology. By demonstrating training to a standardized curriculum, medical physicists throughout Europe will enhance their mobility, while maintaining local high standards of medical physics expertise. This document also provides the basis for improved implementation of articles in the European medical exposure directives related to the medical physics expert. The curriculum is divided into three main sections: The first deals with general competencies in the principles of medical physics. The second section describes specific knowledge and skills required for a medical physicist (medical physics expert) to operate clinically in a department of diagnostic radiology. The final section outlines research skills that are also considered to be necessary and appropriate competencies in a career as medical physicist.
- 3 May 2012
- Published by Springer Nature in Insights into Imaging
- Vol. 3 (3) , 197-200
Open AccessCore curriculum for medical physicists in radiology. Recommendations from an EFOMP/ESR working group
Some years ago it was decided that a European curriculum should be developed for medical physicists professionally engaged in the support of clinical diagnostic imaging departments. With this in mind, EFOMP (European Federation of Organisations for Medical Physics) in association with ESR (European Society of Radiology) nominated an expert working group. This curriculum is now to hand. The curriculum is intended to promote best patient care in radiology departments through the harmonization of education and training of medical physicists to a high standard in diagnostic radiology. It is recommended that a medical physicist working in a radiology department should have an advanced level of professional expertise in X-ray imaging, and additionally, depending on local availability, should acquire knowledge and competencies in overseeing ultrasound imaging, nuclear medicine, and MRI technology. By demonstrating training to a standardized curriculum, medical physicists throughout Europe will enhance their mobility, while maintaining local high standards of medical physics expertise. This document also provides the basis for improved implementation of articles in the European medical exposure directives related to the medical physics expert. The curriculum is divided into three main sections: The first deals with general competencies in the principles of medical physics. The second section describes specific knowledge and skills required for a medical physicist (medical physics expert) to operate clinically in a department of diagnostic radiology. The final section outlines research skills that are also considered to be necessary and appropriate competencies in a career as medical physicist.
- 20 July 2011
- Published by Wiley in Medical Physics
- Vol. 38 (S1) , S25-S35
Automated assessment of low contrast sensitivity for CT systems using a model observer
- 20 July 2011
- Published by Wiley in Medical Physics
- Vol. 38 (S1) , S25-S35
Automated assessment of low contrast sensitivity for CT systems using a model observer
- 1 May 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (5) , 1126-1132
Radiation Exposure to Patients in a Multicenter Coronary Angiography Trial (CORE 64)
OBJECTIVE. The objective of this study was to assess the exposure of patients to radiation for the cardiac CT acquisition protocol of the multicenter Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography (CORE 64) trial.MATERIALS AND METHODS. An algorithm for patient dose assessment with Monte Carlo dosimetry was developed for the Aquilion 64-MDCT scanner. During the CORE 64 study, different acquisition protocols were used depending on patient size and sex; therefore, six patient models were constructed representing three men and three women in the categories of small, normal size, and obese. Organ dose and effective dose resulting from the cardiac CT protocol were assessed for these six patient models.RESULTS. The average effective dose for coronary CT angiography (CTA) calculated according to Report 103 of the International Commission on Radiological Protection (ICRP) is 19 mSv (range, 16–26 mSv). The average effective dose for the whole cardiac CT protocol including CT s...
- 1 May 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (5) , 1126-1132
Radiation Exposure to Patients in a Multicenter Coronary Angiography Trial (CORE 64)
OBJECTIVE. The objective of this study was to assess the exposure of patients to radiation for the cardiac CT acquisition protocol of the multicenter Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography (CORE 64) trial.MATERIALS AND METHODS. An algorithm for patient dose assessment with Monte Carlo dosimetry was developed for the Aquilion 64-MDCT scanner. During the CORE 64 study, different acquisition protocols were used depending on patient size and sex; therefore, six patient models were constructed representing three men and three women in the categories of small, normal size, and obese. Organ dose and effective dose resulting from the cardiac CT protocol were assessed for these six patient models.RESULTS. The average effective dose for coronary CT angiography (CTA) calculated according to Report 103 of the International Commission on Radiological Protection (ICRP) is 19 mSv (range, 16–26 mSv). The average effective dose for the whole cardiac CT protocol including CT s...
- 21 August 2010
- Published by Springer Nature in Pediatric Radiology
- Vol. 40 (11) , 1744-1747
The use of breast shielding for dose reduction in pediatric CT: arguments against the proposition
- 21 August 2010
- Published by Springer Nature in Pediatric Radiology
- Vol. 40 (11) , 1744-1747
The use of breast shielding for dose reduction in pediatric CT: arguments against the proposition
- Open Access
- 14 January 2010
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 26 (4) , 473-482
Assessment of coronary artery calcium by using volumetric 320-row multi-detector computed tomography: comparison of 0.5 mm with 3.0 mm slice reconstructions
The purpose of this study was to assess the performance of 0.5 versus 3.0 mm slice reconstructions in depicting coronary calcium with special attention to patients having zero calcium scores at 3.0 mm reconstructions by using computed tomography (CT). Imaging was performed by volumetric 320-detector row CT. Scans of 100 patients with a negative and 100 patients with a positive Agatston score at 3.0 mm reconstructions were consecutively selected. Non-overlapping volume sets with 3.0 and 0.5 mm slice thickness were reconstructed from the same raw data and Agatston and volume scores were obtained. The Wilcoxon signed ranks test was used to determine statistical differences between 3.0 and 0.5 mm calcium scores. Agatston and volume scores obtained at 0.5 mm were significantly higher than at 3.0 mm reconstructions (mean Agatston score: 266 ± 495 vs. 231 ± 461. Mean volume score: 223 ± 399 vs. 206 ± 385, both P < 0.01). In 21% of patients with zero 3.0 mm Agatston scores, a positive Agatston and/or volume score was found at 0.5 mm reconstructions. With volumetric 320-detector row CT, prospective ECG-triggered calcium scoring at 0.5 mm compared to 3.0 mm reconstructions leads to an increase in Agatston and volume scores and small amounts of coronary calcium are earlier depicted. This may be of special interest in patients with zero calcium scores with traditional 3.0 mm measures, where 0.5 mm reconstructions may help in superior depicting or ruling out coronary artery disease.
- 14 January 2010
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 26 (4) , 473-482
Open AccessAssessment of coronary artery calcium by using volumetric 320-row multi-detector computed tomography: comparison of 0.5 mm with 3.0 mm slice reconstructions
The purpose of this study was to assess the performance of 0.5 versus 3.0 mm slice reconstructions in depicting coronary calcium with special attention to patients having zero calcium scores at 3.0 mm reconstructions by using computed tomography (CT). Imaging was performed by volumetric 320-detector row CT. Scans of 100 patients with a negative and 100 patients with a positive Agatston score at 3.0 mm reconstructions were consecutively selected. Non-overlapping volume sets with 3.0 and 0.5 mm slice thickness were reconstructed from the same raw data and Agatston and volume scores were obtained. The Wilcoxon signed ranks test was used to determine statistical differences between 3.0 and 0.5 mm calcium scores. Agatston and volume scores obtained at 0.5 mm were significantly higher than at 3.0 mm reconstructions (mean Agatston score: 266 ± 495 vs. 231 ± 461. Mean volume score: 223 ± 399 vs. 206 ± 385, both P < 0.01). In 21% of patients with zero 3.0 mm Agatston scores, a positive Agatston and/or volume score was found at 0.5 mm reconstructions. With volumetric 320-detector row CT, prospective ECG-triggered calcium scoring at 0.5 mm compared to 3.0 mm reconstructions leads to an increase in Agatston and volume scores and small amounts of coronary calcium are earlier depicted. This may be of special interest in patients with zero calcium scores with traditional 3.0 mm measures, where 0.5 mm reconstructions may help in superior depicting or ruling out coronary artery disease.
- 1 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (6Part5) , 2472-2473
SU-FF-I-164: Automated Suppression of Ribs in Digital PA Chest Images by Means of Image Processing
- 1 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (6Part5) , 2472-2473
SU-FF-I-164: Automated Suppression of Ribs in Digital PA Chest Images by Means of Image Processing