Brett E. Bouma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brett E. Bouma has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Guillermo J. Tearney
Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St, Boston, MA, USA
11 shared publications - Melissa J. Suter
Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, Massachusetts.
8 shared publications - Norman S. Nishioka
Gastrointestinal Unit, Massachusetts General Hospital, Boston, Massachusetts 02114
7 shared publications - Benjamin J. Vakoc
Harvard Medical School
4 shared publications - Caroline Boudoux
Department of Engineering Physics, Polytechnique Montréal
3 shared publications - Gregory Y. Lauwers
Massachusetts General Hospital
3 shared publications
Latest Publications
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77  (5) , AB151-AB152
418 Volumetric Microscopy Biopsy Guidance Platform for Barrett's Esophagus: a Pilot Study
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77  (5) , AB151-AB152
418 Volumetric Microscopy Biopsy Guidance Platform for Barrett's Esophagus: a Pilot Study
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142  (5)
Sa1830 Interobserver Agreement for the Detection of Barrett's Esophagus With Optical Frequency Domain Imaging (OFDI)
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142  (5)
Sa1830 Interobserver Agreement for the Detection of Barrett's Esophagus With Optical Frequency Domain Imaging (OFDI)
- 14 October 2011
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28  (6) , 1299-1304
Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography
Intracoronary optical coherence tomography and optical frequency domain imaging (OFDI) have been utilized for two-dimensional and three-dimensional imaging of vascular microanatomy. Image quality and the spatial accuracy of multidimensional reconstructions, however, can be degraded due to artifacts resulting from relative motion between the intracoronary catheter and the vessel wall. To track the relative motion of a catheter with regard to the vessel, a motion tracking system was incorporated with a standard OFDI system by using wavelength division multiplexing techniques. Motion of the vessel was acquired by a frequency shift of the backscattered light caused by the Doppler effect. A single monochromatic beam was utilized for tracking the relative longitudinal displacements of a catheter-based fiber probe with regard to the vessel. Although two tracking beams are, in general, required to correct for longitudinal motion artifacts, the accurate reconstruction in a longitudinal view was achieved by the Doppler frequency information of a single beam. Our results demonstrate that the single beam based motion tracking scheme is a cost-effective, practical approach to compensating for longitudinal distortions due to cardiac dynamics, thus leading to accurate quantitative analysis of 3D intracoronary OFDI.
- 14 October 2011
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28  (6) , 1299-1304
Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography
Intracoronary optical coherence tomography and optical frequency domain imaging (OFDI) have been utilized for two-dimensional and three-dimensional imaging of vascular microanatomy. Image quality and the spatial accuracy of multidimensional reconstructions, however, can be degraded due to artifacts resulting from relative motion between the intracoronary catheter and the vessel wall. To track the relative motion of a catheter with regard to the vessel, a motion tracking system was incorporated with a standard OFDI system by using wavelength division multiplexing techniques. Motion of the vessel was acquired by a frequency shift of the backscattered light caused by the Doppler effect. A single monochromatic beam was utilized for tracking the relative longitudinal displacements of a catheter-based fiber probe with regard to the vessel. Although two tracking beams are, in general, required to correct for longitudinal motion artifacts, the accurate reconstruction in a longitudinal view was achieved by the Doppler frequency information of a single beam. Our results demonstrate that the single beam based motion tracking scheme is a cost-effective, practical approach to compensating for longitudinal distortions due to cardiac dynamics, thus leading to accurate quantitative analysis of 3D intracoronary OFDI.
- Open Access
- 14 May 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18  (11) , 11418-11427
Compensation of motion artifacts in catheter-based optical frequency domain imaging
A novel heterodyne Doppler interferometer method for compensating motion artifacts caused by cardiac motion in intracoronary optical frequency domain imaging (OFDI) is demonstrated. To track the relative motion of a catheter with regard to the vessel, a motion tracking system is incorporated with a standard OFDI system by using wavelength division multiplexing (WDM) techniques. Without affecting the imaging beam, dual WDM monochromatic beams are utilized for tracking the relative radial and longitudinal velocities of a catheter-based fiber probe. Our results demonstrate that tracking instantaneous velocity can be used to compensate for distortion in the images due to motion artifacts, thus leading to accurate reconstruction and volumetric measurements with catheter-based imaging.
- 14 May 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18  (11) , 11418-11427
Open AccessCompensation of motion artifacts in catheter-based optical frequency domain imaging
A novel heterodyne Doppler interferometer method for compensating motion artifacts caused by cardiac motion in intracoronary optical frequency domain imaging (OFDI) is demonstrated. To track the relative motion of a catheter with regard to the vessel, a motion tracking system is incorporated with a standard OFDI system by using wavelength division multiplexing (WDM) techniques. Without affecting the imaging beam, dual WDM monochromatic beams are utilized for tracking the relative radial and longitudinal velocities of a catheter-based fiber probe. Our results demonstrate that tracking instantaneous velocity can be used to compensate for distortion in the images due to motion artifacts, thus leading to accurate reconstruction and volumetric measurements with catheter-based imaging.
- Top Cited Papers
- 13 September 2009
- Published by Springer Nature in Nature Medicine
- Vol. 15  (10) , 1219-1223
Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging
Optical frequency domain imaging (OFDI) is a wide-field, three-dimensional intravital imaging technique that provides information on the entire tumor vasculature and surrounding tissue microenvironment, allowing visualization of angiogenesis and lymphangiogenesis during tumor growth and with therapy. Here, Vakoc et al. show that, in contrast to multiphoton microscopy, OFDI can image at greater tissue depths with a wider field of view and without the need for exogenous contrast agents. Intravital multiphoton microscopy has provided powerful mechanistic insights into health and disease and has become a common instrument in the modern biological laboratory. The requisite high numerical aperture and exogenous contrast agents that enable multiphoton microscopy, however, limit the ability to investigate substantial tissue volumes or to probe dynamic changes repeatedly over prolonged periods. Here we introduce optical frequency domain imaging (OFDI) as an intravital microscopy that circumvents the technical limitations of multiphoton microscopy and, as a result, provides unprecedented access to previously unexplored, crucial aspects of tissue biology. Using unique OFDI-based approaches and entirely intrinsic mechanisms of contrast, we present rapid and repeated measurements of tumor angiogenesis, lymphangiogenesis, tissue viability and both vascular and cellular responses to therapy, thereby demonstrating the potential of OFDI to facilitate the exploration of physiological and pathological processes and the evaluation of treatment strategies.
- 13 September 2009
- Published by Springer Nature in Nature Medicine
- Vol. 15  (10) , 1219-1223
Top Cited PapersThree-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging
Optical frequency domain imaging (OFDI) is a wide-field, three-dimensional intravital imaging technique that provides information on the entire tumor vasculature and surrounding tissue microenvironment, allowing visualization of angiogenesis and lymphangiogenesis during tumor growth and with therapy. Here, Vakoc et al. show that, in contrast to multiphoton microscopy, OFDI can image at greater tissue depths with a wider field of view and without the need for exogenous contrast agents. Intravital multiphoton microscopy has provided powerful mechanistic insights into health and disease and has become a common instrument in the modern biological laboratory. The requisite high numerical aperture and exogenous contrast agents that enable multiphoton microscopy, however, limit the ability to investigate substantial tissue volumes or to probe dynamic changes repeatedly over prolonged periods. Here we introduce optical frequency domain imaging (OFDI) as an intravital microscopy that circumvents the technical limitations of multiphoton microscopy and, as a result, provides unprecedented access to previously unexplored, crucial aspects of tissue biology. Using unique OFDI-based approaches and entirely intrinsic mechanisms of contrast, we present rapid and repeated measurements of tumor angiogenesis, lymphangiogenesis, tissue viability and both vascular and cellular responses to therapy, thereby demonstrating the potential of OFDI to facilitate the exploration of physiological and pathological processes and the evaluation of treatment strategies.
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69  (5) , AB107
Guided Esophageal Surveillance Biopsy with a Laser Marking Optical Frequency Domain Imaging System
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69  (5) , AB107
Guided Esophageal Surveillance Biopsy with a Laser Marking Optical Frequency Domain Imaging System
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69  (5) , AB368
Combined Reflection Confocal Microscopy and Optical Coherence Tomography Imaging of Esophageal Biopsy
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69  (5) , AB368
Combined Reflection Confocal Microscopy and Optical Coherence Tomography Imaging of Esophageal Biopsy
- 24 March 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 28  (9) , 1468-1472
Real-Time FPGA Processing for High-Speed Optical Frequency Domain Imaging
We present a novel algorithm for reconstructing interferograms acquired in optical frequency domain imaging (OFDI). The algorithm was developed specifically for processing in field programmable gate arrays (FPGAs) and featured the use of a finite-impulse-response (FIR) filter implementation of B -spline interpolation for efficiently re-sampling k -space. When implemented in FPGAs, the algorithm allowed for real-time processing of interferograms acquired with a high-speed OFDI system at 54 kHz and a sampling rate of 100 MS/s.
- 24 March 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 28  (9) , 1468-1472
Real-Time FPGA Processing for High-Speed Optical Frequency Domain Imaging
We present a novel algorithm for reconstructing interferograms acquired in optical frequency domain imaging (OFDI). The algorithm was developed specifically for processing in field programmable gate arrays (FPGAs) and featured the use of a finite-impulse-response (FIR) filter implementation of B -spline interpolation for efficiently re-sampling k -space. When implemented in FPGAs, the algorithm allowed for real-time processing of interferograms acquired with a high-speed OFDI system at 54 kHz and a sampling rate of 100 MS/s.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7172, 717206
Combined spectrally encoded confocal microscopy and optical frequency domain imaging system
Spectrally encoded confocal microscopy (SECM) and optical frequency domain imaging (OFDI) are two reflectancebased imaging technologies that may be utilized for high-resolution microscopic screening of internal organs. SECM provides en face images of tissues with a high lateral resolution of 1-2 μm, and a penetration depth of up to 300 μm. OFDI generates cross-sectional images of tissue architecture with a resolution of 10-20 μm and a penetration depth of 1- 2 mm. Since the two technologies yield complementary microscopic information on two different size scales (SECM-cellular and OFDI-architectural) that are commonly used for histopathologic evaluation, their combination may allow for more accurate optical diagnosis. Here, we report the integration of these two imaging modalities in a single bench top system. SECM images of swine small intestine showed the presence of goblet cells, and OFDI images revealed the finger-shaped villous architecture. In clinical study of 9 gastroesophageal biopsies from 8 patients, a diverse set of architectural and cellular features was observed, including squamous mucosa with mild hyperplasia and gastric antral mucosa with gastric pits and crypts. The capability of this multimodality device to enable the visualization of microscopic features on these two size scales supports our hypothesis that improved diagnostic accuracy may be obtained by merging these two technologies into a single instrument.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7172, 717206
Combined spectrally encoded confocal microscopy and optical frequency domain imaging system
Spectrally encoded confocal microscopy (SECM) and optical frequency domain imaging (OFDI) are two reflectancebased imaging technologies that may be utilized for high-resolution microscopic screening of internal organs. SECM provides en face images of tissues with a high lateral resolution of 1-2 μm, and a penetration depth of up to 300 μm. OFDI generates cross-sectional images of tissue architecture with a resolution of 10-20 μm and a penetration depth of 1- 2 mm. Since the two technologies yield complementary microscopic information on two different size scales (SECM-cellular and OFDI-architectural) that are commonly used for histopathologic evaluation, their combination may allow for more accurate optical diagnosis. Here, we report the integration of these two imaging modalities in a single bench top system. SECM images of swine small intestine showed the presence of goblet cells, and OFDI images revealed the finger-shaped villous architecture. In clinical study of 9 gastroesophageal biopsies from 8 patients, a diverse set of architectural and cellular features was observed, including squamous mucosa with mild hyperplasia and gastric antral mucosa with gastric pits and crypts. The capability of this multimodality device to enable the visualization of microscopic features on these two size scales supports our hypothesis that improved diagnostic accuracy may be obtained by merging these two technologies into a single instrument.
- 1 February 2009
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 20  (1) , 111-118
Fourier-domain optical coherence tomography: recent advances toward clinical utility
- 1 February 2009
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 20  (1) , 111-118
Fourier-domain optical coherence tomography: recent advances toward clinical utility