Peter A. Brady
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter A. Brady has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Grace Lin
Department of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota, USA
5 shared publicationsDavid L. Hayes
Division of Cardiovascular Diseases, Department of Medicine , Mayo Clinic , Gonda 5 South, 200 First St SW, Rochester, MN 55905 , USA
3 shared publications- Grace Lin
Mayo Clinic, United States
3 shared publications - Angela Dispenzieri
Division of Hematology, Mayo Clinic, Rochester, USA
2 shared publications Alan Sugrue
Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota, USA
1 shared publication- Alejandro A. Rabinstein
From the Department of Neurology, Mayo Clinic, Rochester, MN
1 shared publication
Latest Publications
- Open Access
- 23 February 2017
- Published by BMJ in Open Heart
- Vol. 4 (1) , e000561
Utility of T-wave amplitude as a non-invasive risk marker of sudden cardiac death in hypertrophic cardiomyopathy
Objective Sudden cardiac arrest (SCA) is the most devastating outcome in hypertrophic cardiomyopathy (HCM). We evaluated repolarisation features on the surface electrocardiogram (ECG) to identify the potential risk factors for SCA. Methods Data was collected from 52 patients with HCM who underwent implantable cardioverter defibrillator (ICD) implantation. Leads V2 and V5 from the ECG closest to the time of ICD implant were utilised for measuring the Tpeak-Tend interval (Tpe), QTc, Tpe/QTc, T-wave duration and T-wave amplitude. The presence of the five traditional SCA-associated risk factors was assessed, as well as the HCM risk-SCD score. Results 16 (30%) patients experienced aborted cardiac arrest over 8.5±4.1 years, with 9 receiving an ICD shock and 7 receiving ATP. On univariate analysis, T-wave amplitude was associated with appropriate ICD therapy (HR per 0.1 mV 0.79, 95% CI 0.56 to 0.96, p=0.02). Aborted SCA was not associated with a greater mean QTc duration, Tpeak-Tend interval, T-wave duration, or Tpe/QT ratio. Multivariate analysis (adjusting for cardinal HCM SCA-risk factors) showed T-wave amplitude in Lead V2 was an independent predictor of risk (adjusted HR per 0.1 mV 0.74, 95% CI 0.57 to 0.97, p=0.03). Addition of T-wave amplitude in Lead V2 to the traditional risk factors resulted in significant improvement in risk stratification (C-statistic from 0.65 to 0.75) but did not improve the performance of the HCM SCD-risk score. Conclusions T-wave amplitude is a novel marker of SCA in this high risk HCM population and may provide incremental predictive value to established risk factors. Further work is needed to define the role of repolarisation abnormalities in predicting SCA in HCM.
- 23 February 2017
- Published by BMJ in Open Heart
- Vol. 4 (1) , e000561
Open AccessUtility of T-wave amplitude as a non-invasive risk marker of sudden cardiac death in hypertrophic cardiomyopathy
Objective Sudden cardiac arrest (SCA) is the most devastating outcome in hypertrophic cardiomyopathy (HCM). We evaluated repolarisation features on the surface electrocardiogram (ECG) to identify the potential risk factors for SCA. Methods Data was collected from 52 patients with HCM who underwent implantable cardioverter defibrillator (ICD) implantation. Leads V2 and V5 from the ECG closest to the time of ICD implant were utilised for measuring the Tpeak-Tend interval (Tpe), QTc, Tpe/QTc, T-wave duration and T-wave amplitude. The presence of the five traditional SCA-associated risk factors was assessed, as well as the HCM risk-SCD score. Results 16 (30%) patients experienced aborted cardiac arrest over 8.5±4.1 years, with 9 receiving an ICD shock and 7 receiving ATP. On univariate analysis, T-wave amplitude was associated with appropriate ICD therapy (HR per 0.1 mV 0.79, 95% CI 0.56 to 0.96, p=0.02). Aborted SCA was not associated with a greater mean QTc duration, Tpeak-Tend interval, T-wave duration, or Tpe/QT ratio. Multivariate analysis (adjusting for cardinal HCM SCA-risk factors) showed T-wave amplitude in Lead V2 was an independent predictor of risk (adjusted HR per 0.1 mV 0.74, 95% CI 0.57 to 0.97, p=0.03). Addition of T-wave amplitude in Lead V2 to the traditional risk factors resulted in significant improvement in risk stratification (C-statistic from 0.65 to 0.75) but did not improve the performance of the HCM SCD-risk score. Conclusions T-wave amplitude is a novel marker of SCA in this high risk HCM population and may provide incremental predictive value to established risk factors. Further work is needed to define the role of repolarisation abnormalities in predicting SCA in HCM.
- Open Access
- 3 November 2016
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 16 (1) , 1-8
Electrocardiographic and Echocardiographic predictors of paroxysmal atrial fibrillation detected after ischemic stroke
Detection of atrial fibrillation after ischemic stroke is challenging due to its paroxysmal nature. We aimed to assess predictors of paroxysmal atrial fibrillation using non-invasive surface ECG and transthoracic echocardiography to select candidates for atrial fibrillation screening. Ischemic stroke patients without documented atrial fibrillation (n = 110, 67 ± 10 years, 40 female) and a control group of age- and gender-matched patients with history of paroxysmal atrial fibrillation prior to stroke (n = 55, 67 ± 10 years, 19 female) comprised the study sample. Using non-invasive ECG monitoring for three weeks, short episodes of paroxysmal atrial fibrillation were detected in 24 of 110 patients (22 %). The standard 12-lead ECG with sinus rhythm at stroke onset was digitally processed and analyzed. Transthoracic echocardiography data were reviewed for these patients. Atrial fibrillation history was independently associated with P terminal force in lead V 1 > 40 mm*ms (OR 4.04 95 % CI 1.34–12.14, p = 0.013) and left atrial volume index (OR 1.08 95 % CI 1.03–1.13, p = 0.002; for LAVI > 40 mL/m2 OR 6.40 95 % CL 1.47–27.91, p = 0.013). Among patients without atrial fibrillation history, no ECG characteristics were predictive of atrial fibrillation detected after stroke. Left atrial volume index remained an independent predictor of atrial fibrillation detected after stroke (OR 1.09 95 % CI 1.02–1.16, p = 0.017). A cutoff of <40 mL/m2 had an 84 % negative predictive value for ruling out atrial fibrillation on ambulatory monitoring with a sensitivity of 50 % and a specificity of 86 %. In a post hoc analysis, left atrial dilatation assessed by left atrial volume index independently predicted atrial fibrillation after stroke in patients without prior atrial fibrillation history, while the other clinical or ECG markers were not predictive of atrial fibrillation detected early after ischemic stroke. This study is a post hoc analysis from the prospective case-control study registered in December 2011, ClinicalTrials.gov ID: NCT01325545 .
- 3 November 2016
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 16 (1) , 1-8
Open AccessElectrocardiographic and Echocardiographic predictors of paroxysmal atrial fibrillation detected after ischemic stroke
Detection of atrial fibrillation after ischemic stroke is challenging due to its paroxysmal nature. We aimed to assess predictors of paroxysmal atrial fibrillation using non-invasive surface ECG and transthoracic echocardiography to select candidates for atrial fibrillation screening. Ischemic stroke patients without documented atrial fibrillation (n = 110, 67 ± 10 years, 40 female) and a control group of age- and gender-matched patients with history of paroxysmal atrial fibrillation prior to stroke (n = 55, 67 ± 10 years, 19 female) comprised the study sample. Using non-invasive ECG monitoring for three weeks, short episodes of paroxysmal atrial fibrillation were detected in 24 of 110 patients (22 %). The standard 12-lead ECG with sinus rhythm at stroke onset was digitally processed and analyzed. Transthoracic echocardiography data were reviewed for these patients. Atrial fibrillation history was independently associated with P terminal force in lead V 1 > 40 mm*ms (OR 4.04 95 % CI 1.34–12.14, p = 0.013) and left atrial volume index (OR 1.08 95 % CI 1.03–1.13, p = 0.002; for LAVI > 40 mL/m2 OR 6.40 95 % CL 1.47–27.91, p = 0.013). Among patients without atrial fibrillation history, no ECG characteristics were predictive of atrial fibrillation detected after stroke. Left atrial volume index remained an independent predictor of atrial fibrillation detected after stroke (OR 1.09 95 % CI 1.02–1.16, p = 0.017). A cutoff of <40 mL/m2 had an 84 % negative predictive value for ruling out atrial fibrillation on ambulatory monitoring with a sensitivity of 50 % and a specificity of 86 %. In a post hoc analysis, left atrial dilatation assessed by left atrial volume index independently predicted atrial fibrillation after stroke in patients without prior atrial fibrillation history, while the other clinical or ECG markers were not predictive of atrial fibrillation detected early after ischemic stroke. This study is a post hoc analysis from the prospective case-control study registered in December 2011, ClinicalTrials.gov ID: NCT01325545 .
- 5 May 2015
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 36 (25) , 1569-1570
Orthostatic hypotension: a new cardiac risk factor?
This editorial refers to ‘Cardiovascular morbidity and mortality related to orthostatic hypotension: a meta-analysis of prospective observational studies’, by F. Ricci et al ., on page doi:10.1093/eurheartj/ehv093. Compensatory mechanisms that allow functional and sustained upright posture in humans have evolved over millions of years yet remain poorly understood. Orthostasis, derived from the Greek words orthós and stásis , meaning upright or standing, requires sufficient and sustained venous return to the heart that can overcome gravitational pooling of blood in the abdomen, pelvis, and lower extremities, and relies on a complex interplay between autoregulatory cardiovascular, autonomic, and neuroendocrine pathways as well as often subconscious physical counter-manouevres such as leg crossing and arm folding, etc. which reduce venous capacitance and increase peripheral resistance to augment venous return.1 Transient or sustained failure of one or more of these mechanisms causes symptoms due to impaired organ perfusion termed orthostatic intolerance.2,3 Within the broad clinical manifestations of orthostatic intolerance, several discrete disorders are recognized: neurocardiogenic (vaso-vagal) syncope, the postural orthostatic tachycardia syndrome, inappropriate sinus tachycardia, chronic fatigue,2,4,5 and fibromyalgia syndromes.6,7 While each of these clinical syndromes is distinct, considerable overlap exists consistent with a unifying pathophysiology. Importantly, common to each of these discrete manifestations of orthostatic intolerance is a very benign long-term prognosis. Another common …
- 5 May 2015
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 36 (25) , 1569-1570
Orthostatic hypotension: a new cardiac risk factor?
This editorial refers to ‘Cardiovascular morbidity and mortality related to orthostatic hypotension: a meta-analysis of prospective observational studies’, by F. Ricci et al ., on page doi:10.1093/eurheartj/ehv093. Compensatory mechanisms that allow functional and sustained upright posture in humans have evolved over millions of years yet remain poorly understood. Orthostasis, derived from the Greek words orthós and stásis , meaning upright or standing, requires sufficient and sustained venous return to the heart that can overcome gravitational pooling of blood in the abdomen, pelvis, and lower extremities, and relies on a complex interplay between autoregulatory cardiovascular, autonomic, and neuroendocrine pathways as well as often subconscious physical counter-manouevres such as leg crossing and arm folding, etc. which reduce venous capacitance and increase peripheral resistance to augment venous return.1 Transient or sustained failure of one or more of these mechanisms causes symptoms due to impaired organ perfusion termed orthostatic intolerance.2,3 Within the broad clinical manifestations of orthostatic intolerance, several discrete disorders are recognized: neurocardiogenic (vaso-vagal) syncope, the postural orthostatic tachycardia syndrome, inappropriate sinus tachycardia, chronic fatigue,2,4,5 and fibromyalgia syndromes.6,7 While each of these clinical syndromes is distinct, considerable overlap exists consistent with a unifying pathophysiology. Importantly, common to each of these discrete manifestations of orthostatic intolerance is a very benign long-term prognosis. Another common …
- Open Access
- 10 November 2010
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 32 (2) , 184-190
Renal function and mortality following cardiac resynchronization therapy
Cardiac resynchronization therapy (CRT) improves outcomes in heart failure, yet selection of patients likely to have survival benefit is problematic. Chronic kidney disease (CKD) is an important determinant of mortality in patients with congestive heart failure therefore we sought to determine the impact of CKD on mortality benefit after CRT. All CRT device implantations in patients not on dialysis at Mayo Clinic between January 1999 and December 2005 were included. Of 482 patients, 342 (71%) had CKD (defined as a glomerular filtration rate (GFR) of ≤60 mL/min/1.73 m2) at the time of device implantation. Patients with CKD were older (71 ± 10 vs. 63 ± 14 years, P < 0.01) than patients without CKD, and more often anaemic (12.70 ± 1.73 vs. 13.24 mg/L, P < 0.01), with similar ejection fraction (22 ± 8 vs. 23 ± 8%, P = 0.32). Survival was superior in patients with normal or mild renal dysfunction compared with patients with CKD (72 vs. 57% at 3 years, P < 0.01). After multivariate analysis, CKD remained a significant predictor of poor survival following CRT. Chronic kidney disease is common in patients undergoing CRT and associated with a higher mortality and should be considered when evaluating patients for CRT.
- 10 November 2010
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 32 (2) , 184-190
Open AccessRenal function and mortality following cardiac resynchronization therapy
Cardiac resynchronization therapy (CRT) improves outcomes in heart failure, yet selection of patients likely to have survival benefit is problematic. Chronic kidney disease (CKD) is an important determinant of mortality in patients with congestive heart failure therefore we sought to determine the impact of CKD on mortality benefit after CRT. All CRT device implantations in patients not on dialysis at Mayo Clinic between January 1999 and December 2005 were included. Of 482 patients, 342 (71%) had CKD (defined as a glomerular filtration rate (GFR) of ≤60 mL/min/1.73 m2) at the time of device implantation. Patients with CKD were older (71 ± 10 vs. 63 ± 14 years, P < 0.01) than patients without CKD, and more often anaemic (12.70 ± 1.73 vs. 13.24 mg/L, P < 0.01), with similar ejection fraction (22 ± 8 vs. 23 ± 8%, P = 0.32). Survival was superior in patients with normal or mild renal dysfunction compared with patients with CKD (72 vs. 57% at 3 years, P < 0.01). After multivariate analysis, CKD remained a significant predictor of poor survival following CRT. Chronic kidney disease is common in patients undergoing CRT and associated with a higher mortality and should be considered when evaluating patients for CRT.
- 1 September 2010
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 29 (2) , 75-81
ECG-gated dual-source CT for detection of left atrial appendage thrombus in patients undergoing catheter ablation for atrial fibrillation
Left atrial ablation is increasingly used to treat patients with symptomatic atrial fibrillation (AF). Prior to ablation, exclusion of left atrial appendage (LAA) thrombus is important. Whether ECG-gated dual-source computed tomography (DSCT) provides a sensitive means of detecting LAA thrombus in patients undergoing percutaneous AF ablation is unknown. Thus, we sought to determine the utility of ECG-gated DSCT in detecting LAA thrombus in patients with AF.
- 1 September 2010
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 29 (2) , 75-81
ECG-gated dual-source CT for detection of left atrial appendage thrombus in patients undergoing catheter ablation for atrial fibrillation
Left atrial ablation is increasingly used to treat patients with symptomatic atrial fibrillation (AF). Prior to ablation, exclusion of left atrial appendage (LAA) thrombus is important. Whether ECG-gated dual-source computed tomography (DSCT) provides a sensitive means of detecting LAA thrombus in patients undergoing percutaneous AF ablation is unknown. Thus, we sought to determine the utility of ECG-gated DSCT in detecting LAA thrombus in patients with AF.
- Open Access
- 8 January 2010
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 31 (12) , 1538
Successful termination of a ventricular arrhythmia by implantable cardioverter defibrillator therapy in a patient with cardiac amyloidosis: insight into mechanisms of sudden death
The precise mechanism of sudden cardiac arrest in patients with AL-type cardiac amyloidosis is not well understood and often attributed to pulseless electrical activity, thereby implying a lack of benefit of implantable cardioverter defibrillator (ICD) in this patient population. We report on a 60-year-old male undergoing treatment for AL-type biopsy proven cardiac amyloidosis who had undergone prophylactic placement of an ICD following an episode of syncope in association with impaired left ventricular systolic function (ejection fraction of 20%), who presented 3 years later with multiple ICD firings. Device interrogation demonstrated several episodes of both monomorphic ventricular tachycardia and ventricular fibrillation, all successfully terminated by the ICD (Panels A and B). He was discharged subsequently from hospital on amiodarone and has experienced no further shocks during follow-up.
- 8 January 2010
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 31 (12) , 1538
Open AccessSuccessful termination of a ventricular arrhythmia by implantable cardioverter defibrillator therapy in a patient with cardiac amyloidosis: insight into mechanisms of sudden death
The precise mechanism of sudden cardiac arrest in patients with AL-type cardiac amyloidosis is not well understood and often attributed to pulseless electrical activity, thereby implying a lack of benefit of implantable cardioverter defibrillator (ICD) in this patient population. We report on a 60-year-old male undergoing treatment for AL-type biopsy proven cardiac amyloidosis who had undergone prophylactic placement of an ICD following an episode of syncope in association with impaired left ventricular systolic function (ejection fraction of 20%), who presented 3 years later with multiple ICD firings. Device interrogation demonstrated several episodes of both monomorphic ventricular tachycardia and ventricular fibrillation, all successfully terminated by the ICD (Panels A and B). He was discharged subsequently from hospital on amiodarone and has experienced no further shocks during follow-up.
- 26 August 2009
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 32 (9) , 1117-1122
Long‐term Stability of Endocardial Left Ventricular Pacing Leads Placed via the Coronary Sinus
Background: Left ventricular endocardial pacing leads placed via the coronary sinus (CS) are increasingly implanted to achieve cardiac resynchronization therapy (CRT); however, the long‐term stability of these leads is unknown. We sought to determine the implant success and long‐term stability of CS leads in our single center experience. Methods: All consecutive patients who underwent CRT via implantation of the CS lead between January 1999 and December 2005 were included. Pacing thresholds at implant and during long‐term follow‐up were reviewed and the rate of acute (within 24 hours of implant) and chronic (>24 hours) lead failure was determined. Results: A total of 512 patients (mean age 68 ± 12 years; 409 [80%] male) underwent CRT device implantation and were included. The CS lead implantation was successful on the initial implantation in 487 patients (95%) and subsequently successful in six patients (24%) in whom initial attempts were unsuccessful. Acute lead failure occurred in 25 patients (5.1%) and was most commonly due to persistent extra‐cardiac stimulation. The rate of chronic lead failure was 4% in the first year and remained stable during long‐term follow‐up. The CS lead pacing thresholds remained stable with only minimal increase (1.42 ± 0.85 V/0.42 ± 0.25 ms vs 1.51 ± 1.05 V/0.47 ± 0.29 ms; P = 0.04). Conclusions: Placement of a left ventricular pacing lead via the CS is feasible and safe in the vast majority of patients. Once placed, the CS leads remain stable with excellent pacing thresholds over the longer term.
- 26 August 2009
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 32 (9) , 1117-1122
Long‐term Stability of Endocardial Left Ventricular Pacing Leads Placed via the Coronary Sinus
Background: Left ventricular endocardial pacing leads placed via the coronary sinus (CS) are increasingly implanted to achieve cardiac resynchronization therapy (CRT); however, the long‐term stability of these leads is unknown. We sought to determine the implant success and long‐term stability of CS leads in our single center experience. Methods: All consecutive patients who underwent CRT via implantation of the CS lead between January 1999 and December 2005 were included. Pacing thresholds at implant and during long‐term follow‐up were reviewed and the rate of acute (within 24 hours of implant) and chronic (>24 hours) lead failure was determined. Results: A total of 512 patients (mean age 68 ± 12 years; 409 [80%] male) underwent CRT device implantation and were included. The CS lead implantation was successful on the initial implantation in 487 patients (95%) and subsequently successful in six patients (24%) in whom initial attempts were unsuccessful. Acute lead failure occurred in 25 patients (5.1%) and was most commonly due to persistent extra‐cardiac stimulation. The rate of chronic lead failure was 4% in the first year and remained stable during long‐term follow‐up. The CS lead pacing thresholds remained stable with only minimal increase (1.42 ± 0.85 V/0.42 ± 0.25 ms vs 1.51 ± 1.05 V/0.47 ± 0.29 ms; P = 0.04). Conclusions: Placement of a left ventricular pacing lead via the CS is feasible and safe in the vast majority of patients. Once placed, the CS leads remain stable with excellent pacing thresholds over the longer term.
- 7 March 2008
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 22 (1) , 65-70
Age and gender trends in implantable cardioverter defibrillator utilization: A population based study
Introduction Implantable cardioverter-defibrillators improve mortality in selected high risk patients, yet population based data regarding utilization of these devices, particularly in the elderly, are limited. Methods To address this, we reviewed all ICD implantations performed in Olmsted County, MN, a geographically defined population, between December 1989 and December 2004. Results The study population comprised 179 patients (147 male, 82%, mean age 65 ± 14 years). Baseline ejection fraction and creatinine were 35% ± 16% and 1.38 ± 1.08 mg/dl, respectively. Over the study period, the incidence of congestive heart failure in patients undergoing ICD implantation and referrals for primary prevention ICDs increased, while baseline ejection fraction and etiology of cardiomyopathy remained unchanged. The incidence of ICD implantations increased significantly in the elderly (p < 0.001) and especially in male patients when compared to female patients (p < 0.001). Conclusions Age of patients undergoing ICD implantation is increasing. However, fewer females compared to males are undergoing ICD implantation, suggesting a gender bias in ICD therapy and utilization.
- 7 March 2008
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 22 (1) , 65-70
Age and gender trends in implantable cardioverter defibrillator utilization: A population based study
Introduction Implantable cardioverter-defibrillators improve mortality in selected high risk patients, yet population based data regarding utilization of these devices, particularly in the elderly, are limited. Methods To address this, we reviewed all ICD implantations performed in Olmsted County, MN, a geographically defined population, between December 1989 and December 2004. Results The study population comprised 179 patients (147 male, 82%, mean age 65 ± 14 years). Baseline ejection fraction and creatinine were 35% ± 16% and 1.38 ± 1.08 mg/dl, respectively. Over the study period, the incidence of congestive heart failure in patients undergoing ICD implantation and referrals for primary prevention ICDs increased, while baseline ejection fraction and etiology of cardiomyopathy remained unchanged. The incidence of ICD implantations increased significantly in the elderly (p < 0.001) and especially in male patients when compared to female patients (p < 0.001). Conclusions Age of patients undergoing ICD implantation is increasing. However, fewer females compared to males are undergoing ICD implantation, suggesting a gender bias in ICD therapy and utilization.
- Open Access
Effect of cardiac resynchronisation therapy on occurrence of ventricular arrhythmia in patients with implantable cardioverter defibrillators undergoing upgrade to cardiac resynchronisation therapy devices
Background: Cardiac resynchronisation therapy (CRT) improves outcomes in selected patients with heart failure and left ventricular dysfunction. One mechanism of benefit is believed to be favourable ventricular remodelling. Whether CRT also decreases the frequency of ventricular arrhythmias and risk of sudden death is unknown. Objective: To determine the effect of CRT on frequency of ventricular arrhythmias and appropriate ICD therapies. Design: Retrospective cohort study. Setting: Single-centre, tertiary care facility (Mayo Clinic). Patients: 52 patients (46 male), aged 70 (SD 10) years, who underwent upgrade from an implantable cardioverter defibrillator (ICD) to a CRT-defibrillator were included. Interventions: Upgrade of ICD to CRT-defibrillator. Main Outcome Measures: Frequency of ventricular arrhythmias prior to and following upgrade to CRT device. Results: Ejection fraction increased from 22% (SD 8%) to 27% (SD 11%) following CRT. However, the frequency of non-sustained ventricular arrhythmias, sustained ventricular arrhythmias, and ventricular fibrillation was not significantly changed prior to and following CRT (2.38 (SD 9.78) vs 58.51 (SD 412.73) per patient per month, p = 0.66; 0.07 (SD 0.17) vs 0.16 (SD 0.52), p = 0.70; 0.05 (SD 0.12) vs 0.25 (SD 1.40), p = 0.12). Conclusions: CRT is not associated with a decrease in the frequency of ventricular arrhythmia or appropriate device therapy. Thus, use of CRT alone is not beneficial in decreasing the frequency of ventricular arrhythmias or the risk of appropriate ICD therapies.
Open AccessEffect of cardiac resynchronisation therapy on occurrence of ventricular arrhythmia in patients with implantable cardioverter defibrillators undergoing upgrade to cardiac resynchronisation therapy devices
Background: Cardiac resynchronisation therapy (CRT) improves outcomes in selected patients with heart failure and left ventricular dysfunction. One mechanism of benefit is believed to be favourable ventricular remodelling. Whether CRT also decreases the frequency of ventricular arrhythmias and risk of sudden death is unknown. Objective: To determine the effect of CRT on frequency of ventricular arrhythmias and appropriate ICD therapies. Design: Retrospective cohort study. Setting: Single-centre, tertiary care facility (Mayo Clinic). Patients: 52 patients (46 male), aged 70 (SD 10) years, who underwent upgrade from an implantable cardioverter defibrillator (ICD) to a CRT-defibrillator were included. Interventions: Upgrade of ICD to CRT-defibrillator. Main Outcome Measures: Frequency of ventricular arrhythmias prior to and following upgrade to CRT device. Results: Ejection fraction increased from 22% (SD 8%) to 27% (SD 11%) following CRT. However, the frequency of non-sustained ventricular arrhythmias, sustained ventricular arrhythmias, and ventricular fibrillation was not significantly changed prior to and following CRT (2.38 (SD 9.78) vs 58.51 (SD 412.73) per patient per month, p = 0.66; 0.07 (SD 0.17) vs 0.16 (SD 0.52), p = 0.70; 0.05 (SD 0.12) vs 0.25 (SD 1.40), p = 0.12). Conclusions: CRT is not associated with a decrease in the frequency of ventricular arrhythmia or appropriate device therapy. Thus, use of CRT alone is not beneficial in decreasing the frequency of ventricular arrhythmias or the risk of appropriate ICD therapies.
- 31 December 2007
- Published by Elsevier in International Journal of Cardiology
- Vol. 122, S117-117
P3-65 SINGLE CENTER EXPERIENCE OF DEVICE THERAPY IN CARDIAC AMYLOIDOSIS
- 31 December 2007
- Published by Elsevier in International Journal of Cardiology
- Vol. 122, S117-117
P3-65 SINGLE CENTER EXPERIENCE OF DEVICE THERAPY IN CARDIAC AMYLOIDOSIS