PMPaul J. Missel

Paul J. Missel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul J. Missel has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulating Intravitreal Injections in Anatomically Accurate Models for Rabbit, Monkey, and Human Eyes

    by Paul J. Missel

    Purpose To develop models for rabbit, monkey, and human that enable prediction of the clearance after intravitreal (IVT) injections in one species from experimental results obtained in another species. Methods Anatomically accurate geometric models were constructed for rabbit, monkey, and human that enabled computational fluid dynamic simulation of clearance of an IVT injected bolus. Models were constructed with and without the retrozonular space of Petit. Literature data on clearance after IVT injection of substances spanning a range of molecular weight up to 157 kDa were used to validate the rabbit model. Results The space of Petit had a significant increase on the clearance of slowly diffusing substances cleared by the anterior pathway by reducing the bottleneck for drug efflux. Models that did not include this zone could not accurately predict the clearance of slowly diffusing substances whose clearance was accelerated by intraocular pressure-driven convection. Conclusions The ocular anatomy must be carefully reconstructed in the model to enable accurate predictions of clearance. This method offers an alternative means for scaling experimental data from one species to another that may be more appropriate than other simple approaches based entirely upon scaling of compartment volumes and flow rates.


  • Open Access

    Simulating Dissolution of Intravitreal Triamcinolone Acetonide Suspensions in an Anatomically Accurate Rabbit Eye Model

    by Paul J. Missel, Marc Horner, R. Muralikrishnan

    Purpose A computational fluid dynamics (CFD) study examined the impact of particle size on dissolution rate and residence of intravitreal suspension depots of Triamcinolone Acetonide (TAC). Methods A model for the rabbit eye was constructed using insights from high-resolution NMR imaging studies (Sawada 2002). The current model was compared to other published simulations in its ability to predict clearance of various intravitreally injected materials. Suspension depots were constructed explicitly rendering individual particles in various configurations: 4 or 16 mg drug confined to a 100 μL spherical depot, or 4 mg exploded to fill the entire vitreous. Particle size was reduced systematically in each configuration. The convective diffusion/dissolution process was simulated using a multiphase model. Results Release rate became independent of particle diameter below a certain value. The size-independent limits occurred for particle diameters ranging from 77 to 428 μM depending upon the depot configuration. Residence time predicted for the spherical depots in the size-independent limit was comparable to that observed in vivo. Conclusions Since the size-independent limit was several-fold greater than the particle size of commercially available pharmaceutical TAC suspensions, differences in particle size amongst such products are predicted to be immaterial to their duration or performance.


  • Open Access

    In Vitro Transport and Partitioning of AL-4940, Active Metabolite of Angiostatic Agent Anecortave Acetate, in Ocular Tissues of the Posterior Segment

    by Paul Missel, James Chastain, Ashim Mitra, Uday Kompella, Viral Kansara, Sridhar Duvvuri, Aniruddha Amrite, Narayan Cheruvu

    Purpose.: The purpose of this study was to evaluate partitioning into and transport across posterior segment tissues (sclera, retinal pigment epithelium (RPE)–choroid) of AL-4940, the active metabolite of angiostatic cortisene anecortave acetate (AL-3789). Methods.: Transport of [ 14 C]-AL-4940 was measured through RPE–choroid–sclera (RCS) and sclera, excised from Dutch Belted pigmented rabbits’ eyes, in the directions of scleral to vitreal (S→V) and vitreal to scleral (V→S) for 3 h at 37°C using Ussing chambers. Tissue integrity was monitored by transepithelial electrical resistance (TEER), potential difference (PD), and biochemical assay (LDH). Partitioning in RPE–choroid and sclera was determined separately for both [ 14 C]-AL-4940 and [ 14 C]-AL-3789. Mathematical analysis for bilaminate membranes used partitioning and transport data to derive diffusion coefficients for 2 tissue layers sclera and RPE–choroid. Results.: Partitioning of drug in tissue was comparable for both [ 14 C]-AL-4940 and [ 14 C]-AL-3789. Partition coefficients of drug in tissue were 2.2 for sclera and about 4 for RPE–choroid. Permeability through sclera alone was about 3 × 10 −5 cm/s and about 1 × 10 −5 cm/s through the RCS tissue, irrespective of the direction of transport (S→V) or (V→S). Results from bioelectrical and biochemical evaluation of tissue with modified LDH assay provided evidence that the RCS tissue preparation remained viable during the period of transport study. Conclusions.: The thin RPE–choroid layer contributes significantly to resistance to drug transport, and diffusivity in this layer is 10 times less than in sclera. This experimental scheme is proposed as an important component for the development of a general ocular physiologically based pharmacokinetic model.


  • Adaptation of USP Types II and IV Controlled Release Assays for Sparingly Soluble Compounds by Direct Eluent HPLC Analysis

    by P. J. Missel, L. E. Stevens

    Measurement of drug release of a sparingly soluble drug by conventional methods proceeds very slowly without the aid of surfactants. Two preliminary automated methods were developed that increase sensitivity and accelerate such studies by working at very small reservoir volumes. All high pressure liquid chromatography (HPLC) equipment components were commercially available. Results are presented for the drug release of a single pellet of the sparingly soluble drug Eliprodil in two types of drug release experiments using (1) a stirred cell and (2) a flow-through method. Release rates measured from each method were comparable.


  • Reexamination of Convective Diffusion/Drug Dissolution in a Laminar Flow Channel: Accurate Prediction of Dissolution Rate

    by Paul J. Missel, Larry E. Stevens, John W. Mauger

    The convective diffusion/dissolution theory applied to flow-through dissolution in a laminar channel was reexamined to evaluate how closely it can predict release rate for a model compound on an absolute basis—a comparsion that was lacking from the original literature observations reported from this technique.


  • Dissolution of anecortave acetate in a cylindrical flow cell: re-evaluation of convective diffusion/drug dissolution for sparingly soluble drugs.

    by Paul J. Missel, L. E. Stevens, J. W. Mauger

    Steady-state drug release rates were measured from a model cylindrical implant, comprised mainly of the sparingly soluble drug anecortave acetate, suspended as an obstacle in a cylindrical flow cell. Dissolution medium was delivered at a steady, slow flow rate (0.05-0.7 mLs/min) using an HPLC pump, and samples from the outflow were analyzed by direct injection onto an HPLC column. Release rates were determined as a function of flow rate for three different implant orientations--vertical, elevated to the center of the dissolution cell; horizontal, elevated; and horizontal, resting directly upon the flat porous inlet frit. Release rates were ranked as follows: horizontal, floor > horizontal, elevated>vertical, elevated. The steady, laminar flow enabled use of the finite element method (FEM) to simulate the dissolution process using convective diffusion/drug dissolution theory. Simulations predicted the absolute magnitude of the release rate to within < 10% for all situations, and predicted the power law exponent of the dependence of release rate on flow rate with great accuracy. The current method is more general than compendial methods that provide a dissolving surface that is uniformly accessible to the dissolution medium, or a shear rate that is uniform across the entire dissolving surface. The current approach may be utilized to provide estimates of dissolution rates for any geometry and set of hydrodynamic conditions that can be numerically calculated.


  • Hydraulic Flow and Vascular Clearance Influences on Intravitreal Drug Delivery

    by Paul J. Missel

    Purpose. A recent paper proposed a model for hydraulic flow in the eye, claiming this could affect intravitreal drug administration. The impact of flow on various modes of administration was...


  • Finite and Infinitesimal Representations of the Vasculature: Ocular Drug Clearance by Vascular and Hydraulic Effects

    by Paul J. Missel

    New methods are presented for simulating steady-state drug concentration in vitreous, choroid, and sclera from an intravitreal device. Clearance by choroidal flow and intraocular pressure (IOP)...


  • Finite Element Modeling of Diffusion and Partitioning in Biological Systems: The Infinite Composite Medium Problem

    by Paul J. Missel

    Four methods are proposed for modeling diffusion in heterogeneous media where diffusion and partition coefficients take on differing values in each subregion. The exercise was conducted to validate...