Merrill A. Ritter
Research Subjects
Research Interests
Merrill A. Ritter has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Michael E. Berend
St Francis Hospital-Mooresville
4 shared publications - Scott R. Small
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
4 shared publications - John B. Meding
The Center for Hip and Knee Surgery, St Francis Hospital Mooresville, 1199 Hadley Road, Mooresville, IN 46158, USA
3 shared publications Christine A Buckley
2 shared publicationsJennifer T. Wing
St Francis Hospital
2 shared publicationsJohn B. Meding
St Francis Hospital
2 shared publications
Latest Publications
- 12 October 2017
- Vol. 31, 170-176
Mechanical Strength of the Proximal Tibia Following Total Knee Arthroplasty: A Cadaveric Study of Resection Depth and Bone Density.
Tibial component failure has been a problem in total knee arthroplasty, it is still undetermined how tibial resection depth affects the strength to support a tibial component. This study examined the relationship between the resection depth and the bone density and the mechanical strength to support the tibial component. Eight matched pairs of fresh, frozen cadaver lower legs were imaged with computed tomography to assess the bone density. A right tibia was resected at minimum resection level and a left tibia was resected at deep resection level. After the tibial component was implanted with cement on each tibia, it was loaded on a materials testing load frame to measure the stiffness and the load to failure. The average bone density at the minimum resection level of the tibia was significantly higher than at deep level (p=0.0003). The average stiffness and load to failure of the proximal tibia were 1105 N/mm (range 889 to 1303 N/mm) and 5626 N (range 3360 to 9098 N). There was no statistical correlation between tibial resection depth and the axial stiffness (p=0.4107) or the load to failure (p=0.1487). Although the bone density at a minimum resection level was higher than that at a deep level, the strength to support the tibial component was not statistically higher at a minimum cutting level than at a deeper cutting level proportionally. Surgeons may not need to minimize a proximal tibial bone resection to maintain a stronger support for a tibial component.
- 12 October 2017
- Vol. 31, 170-176
Mechanical Strength of the Proximal Tibia Following Total Knee Arthroplasty: A Cadaveric Study of Resection Depth and Bone Density.
Tibial component failure has been a problem in total knee arthroplasty, it is still undetermined how tibial resection depth affects the strength to support a tibial component. This study examined the relationship between the resection depth and the bone density and the mechanical strength to support the tibial component. Eight matched pairs of fresh, frozen cadaver lower legs were imaged with computed tomography to assess the bone density. A right tibia was resected at minimum resection level and a left tibia was resected at deep resection level. After the tibial component was implanted with cement on each tibia, it was loaded on a materials testing load frame to measure the stiffness and the load to failure. The average bone density at the minimum resection level of the tibia was significantly higher than at deep level (p=0.0003). The average stiffness and load to failure of the proximal tibia were 1105 N/mm (range 889 to 1303 N/mm) and 5626 N (range 3360 to 9098 N). There was no statistical correlation between tibial resection depth and the axial stiffness (p=0.4107) or the load to failure (p=0.1487). Although the bone density at a minimum resection level was higher than that at a deep level, the strength to support the tibial component was not statistically higher at a minimum cutting level than at a deeper cutting level proportionally. Surgeons may not need to minimize a proximal tibial bone resection to maintain a stronger support for a tibial component.
- 12 February 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (4) , 041001
A Finite-Element Study of Metal Backing and Tibial Resection Depth in a Composite Tibia Following Total Knee Arthroplasty
Prosthetic alignment, patient characteristics, and implant design are all factors in long-term survival of total knee arthroplasty (TKA), yet the level at which each of these factors contribute to implant loosening has not been fully described. Prior clinical and biomechanical studies have indicated tibial overload as a cause of early TKA revision. The purpose of this study was to determine the relationship between tibial component design and bone resection on tibial loading. Finite-element analysis (FEA) was performed after simulated implantation of metal backed (MB) and all-polyethylene (AP) TKA components in 5 and 15 mm of tibial resection into a validated intact tibia model. Proximal tibial strains significantly increased between 13% and 199% when implanted with AP components (p < 0.05). Strain significantly increased between 12% and 209% in the posterior tibial compartment with increased bone resection (p < 0.05). This study indicates elevated strains in AP implanted tibias across the entirety of the proximal tibial cortex, as well as a posterior shift in tibial loading in instances of increased resection depth. These results are consistent with trends observed in prior biomechanical studies and may associate the documented device history of tibial collapse in AP components with increased bone strain and overload beneath the prosthesis.
- 12 February 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (4) , 041001
A Finite-Element Study of Metal Backing and Tibial Resection Depth in a Composite Tibia Following Total Knee Arthroplasty
Prosthetic alignment, patient characteristics, and implant design are all factors in long-term survival of total knee arthroplasty (TKA), yet the level at which each of these factors contribute to implant loosening has not been fully described. Prior clinical and biomechanical studies have indicated tibial overload as a cause of early TKA revision. The purpose of this study was to determine the relationship between tibial component design and bone resection on tibial loading. Finite-element analysis (FEA) was performed after simulated implantation of metal backed (MB) and all-polyethylene (AP) TKA components in 5 and 15 mm of tibial resection into a validated intact tibia model. Proximal tibial strains significantly increased between 13% and 199% when implanted with AP components (p < 0.05). Strain significantly increased between 12% and 209% in the posterior tibial compartment with increased bone resection (p < 0.05). This study indicates elevated strains in AP implanted tibias across the entirety of the proximal tibial cortex, as well as a posterior shift in tibial loading in instances of increased resection depth. These results are consistent with trends observed in prior biomechanical studies and may associate the documented device history of tibial collapse in AP components with increased bone strain and overload beneath the prosthesis.
- Open Access
- 1 July 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (7) , 1991-1994
Does High Tibial Osteotomy Affect the Success or Survival of a Total Knee Replacement?
Whether a previous high tibial osteotomy (HTO) influences the long-term function or survival of a total knee arthroplasty (TKA) is controversial. We compared long-term functional scores and survival of bilateral TKAs in patients who had a previous HTO in one of the knees. From 1980 to 1995, we performed 5043 primary TKAs; 39 of these patients had bilateral TKAs at an average of 8.7 years after unilateral HTO. Surgery was simultaneous in 32 patients and staged in seven. There were 12 women and 27 men with an average age of 66.9 years at the time of surgery. At last followup, 19 of the 39 patients were living and had been reevaluated since our previous study. We determined function with Knee Society scores. The length of followup for patients who had HTOs averaged 14 years (range, 3–21 years); for patients without HTOs, the average followup was 13.9 years (range, 3–22 years). We observed no differences in Knee Society function and radiographic and pain scores between the knees without and with previous HTO. Terminal extension and flexion, arc of motion, and knee alignment were similar between the knees. There were no femorotibial revisions in either group of knees. Survival at 15 years was 100% for knees without previous HTO and 97% for knees with previous HTO. Our observations suggest a previous high tibial osteotomy does not influence the function or survival of a knee long term. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 July 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (7) , 1991-1994
Open AccessDoes High Tibial Osteotomy Affect the Success or Survival of a Total Knee Replacement?
Whether a previous high tibial osteotomy (HTO) influences the long-term function or survival of a total knee arthroplasty (TKA) is controversial. We compared long-term functional scores and survival of bilateral TKAs in patients who had a previous HTO in one of the knees. From 1980 to 1995, we performed 5043 primary TKAs; 39 of these patients had bilateral TKAs at an average of 8.7 years after unilateral HTO. Surgery was simultaneous in 32 patients and staged in seven. There were 12 women and 27 men with an average age of 66.9 years at the time of surgery. At last followup, 19 of the 39 patients were living and had been reevaluated since our previous study. We determined function with Knee Society scores. The length of followup for patients who had HTOs averaged 14 years (range, 3–21 years); for patients without HTOs, the average followup was 13.9 years (range, 3–22 years). We observed no differences in Knee Society function and radiographic and pain scores between the knees without and with previous HTO. Terminal extension and flexion, arc of motion, and knee alignment were similar between the knees. There were no femorotibial revisions in either group of knees. Survival at 15 years was 100% for knees without previous HTO and 97% for knees with previous HTO. Our observations suggest a previous high tibial osteotomy does not influence the function or survival of a knee long term. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 February 2011
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 7 (1) , 41-43
Heterotopic Bone Formation following Resurfacing Total Hip Arthroplasty
Heterotopic bone (HO), a rare association with total hip arthroplasty (THA), has recently been shown to be more of a problem with resurfacing hip arthroplasty (RHA). It has been speculated to be the result of greater soft tissue dissection required for this procedure. HO most commonly develops in males and patients with bilateral disease. To better understand if this problem does occur in RHA, groups of patients with RHA on one side and conventional THA on the other were evaluated. We retrospectively identified 45 patients that had RHA on one side and conventional cemented THA on the other. Follow-up has been up to 25 years. HO was graded at every clinical visit using the Brooker Classification. In the RHA group, there were 32 hips without evidence of HO, ten with grade 1, and three with grades 2 or 3. In the THA group, there were 36 hips without any HO, eight with grade 1, and one with grade 2. There was no statistical difference between either types of hip arthroplasty in HO formation overall or in the development of more severe grades. Motion was not significantly affected with the more severe grades. Our data obtained from a bilateral patient model suggests that RHA does not predispose to a greater development of HO. In doing a RHA, one should be aware that there might be an increased likelihood of HO in males with bilateral disease.
- 1 February 2011
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 7 (1) , 41-43
Heterotopic Bone Formation following Resurfacing Total Hip Arthroplasty
Heterotopic bone (HO), a rare association with total hip arthroplasty (THA), has recently been shown to be more of a problem with resurfacing hip arthroplasty (RHA). It has been speculated to be the result of greater soft tissue dissection required for this procedure. HO most commonly develops in males and patients with bilateral disease. To better understand if this problem does occur in RHA, groups of patients with RHA on one side and conventional THA on the other were evaluated. We retrospectively identified 45 patients that had RHA on one side and conventional cemented THA on the other. Follow-up has been up to 25 years. HO was graded at every clinical visit using the Brooker Classification. In the RHA group, there were 32 hips without evidence of HO, ten with grade 1, and three with grades 2 or 3. In the THA group, there were 36 hips without any HO, eight with grade 1, and one with grade 2. There was no statistical difference between either types of hip arthroplasty in HO formation overall or in the development of more severe grades. Motion was not significantly affected with the more severe grades. Our data obtained from a bilateral patient model suggests that RHA does not predispose to a greater development of HO. In doing a RHA, one should be aware that there might be an increased likelihood of HO in males with bilateral disease.
- 30 September 2010
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 25 (6) , 31-35
High Preoperative Range of Motion Is a Significant Risk Factor for Dislocation in Primary Total Hip Arthroplasty
- 30 September 2010
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 25 (6) , 31-35
High Preoperative Range of Motion Is a Significant Risk Factor for Dislocation in Primary Total Hip Arthroplasty
- 31 August 2010
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 25 (5) , 772-774
Total Knee Arthroplasty With 4.4 mm of Tibial Polyethylene: An Update
- 31 August 2010
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 25 (5) , 772-774
Total Knee Arthroplasty With 4.4 mm of Tibial Polyethylene: An Update
- 1 April 2010
- Vol. 19, 185-90
Bearing mobility affects tibial strain in mobile-bearing unicompartmental knee arthroplasty.
Mobile-bearing unicompartmental knees facilitate decreased polyethylene wear and restoration of knee kinematics. The purpose of this study was to quantify tibial strains during bearing mobility in UKA. Composite tibiae were implanted with cemented metal-backed tibial components and coated with photoelastic material, allowing "full-field" strain analysis. A fully congruent mobile polyethylene bearing was loaded in six separate locations on the tibial tray, simulating bearing translation during knee motion. Strains were noted to be greatest in the anteromedial tibia, 2 cm distal to the joint line, which correlates with the area occasionally noted to have residual pain following UKA. This study demonstrates the important role that bearing movement plays in load distribution throughout the tibia after UKA and may illuminate a biomechanical process of tibial remodeling that influences pain and implant loosening.
- 1 April 2010
- Vol. 19, 185-90
Bearing mobility affects tibial strain in mobile-bearing unicompartmental knee arthroplasty.
Mobile-bearing unicompartmental knees facilitate decreased polyethylene wear and restoration of knee kinematics. The purpose of this study was to quantify tibial strains during bearing mobility in UKA. Composite tibiae were implanted with cemented metal-backed tibial components and coated with photoelastic material, allowing "full-field" strain analysis. A fully congruent mobile polyethylene bearing was loaded in six separate locations on the tibial tray, simulating bearing translation during knee motion. Strains were noted to be greatest in the anteromedial tibia, 2 cm distal to the joint line, which correlates with the area occasionally noted to have residual pain following UKA. This study demonstrates the important role that bearing movement plays in load distribution throughout the tibia after UKA and may illuminate a biomechanical process of tibial remodeling that influences pain and implant loosening.
- 1 March 2010
- Published by SLACK, Inc. in Orthopedics
- Vol. 33 (3) , 149-154
Outcome of Infected Total Joint Replacement
Numerous protocols are used to treat an infected total joint arthroplasty. We evaluated survival outcomes of patients with infected total joint arthroplasties over 35 years to determine if one treatment is more effective than others. Of 17,561 total joint arthroplasties performed at our facility, 116 (0.66%) were diagnosed with deep infection, 22 of which (18.97%) were hematogenous. Success rates among resection, 1-stage, and 2-stage reimplantation arthroplasty were compared in each joint, as were organism types. After excluding 8 patients (6.9%) who died within 1 year of final treatment and 8 lost to follow-up, 30 hips and 70 knees were studied. Seventeen hips were treated with 2-stage arthroplasty; 70.6% succeeded after the first attempt, and 82.4% succeeded after the second. Fifty-one 2-stage knees had 54.9% success after the first attempt and 66.7% success after the second. Five of 5 hips treated with 1-stage arthroplasty succeeded after the first attempt, while 1 of 3 one-stage knees succeeded after the first attempt; none of these 8 joints had a hematogenous infection. No joints requiring a third treatment were successful after the third attempt. There were no differences in survival between different bacteria. Treatment of deep prosthetic joint infection is difficult once the first attempt has failed and becomes more so after failure of the second attempt. Two-stage arthroplasty provides good results in most cases (82% in hips, 67% in knees), but a third attempt does not increase these percentages. The organism type does not significantly affect success in infected joint treatment.
- 1 March 2010
- Published by SLACK, Inc. in Orthopedics
- Vol. 33 (3) , 149-154
Outcome of Infected Total Joint Replacement
Numerous protocols are used to treat an infected total joint arthroplasty. We evaluated survival outcomes of patients with infected total joint arthroplasties over 35 years to determine if one treatment is more effective than others. Of 17,561 total joint arthroplasties performed at our facility, 116 (0.66%) were diagnosed with deep infection, 22 of which (18.97%) were hematogenous. Success rates among resection, 1-stage, and 2-stage reimplantation arthroplasty were compared in each joint, as were organism types. After excluding 8 patients (6.9%) who died within 1 year of final treatment and 8 lost to follow-up, 30 hips and 70 knees were studied. Seventeen hips were treated with 2-stage arthroplasty; 70.6% succeeded after the first attempt, and 82.4% succeeded after the second. Fifty-one 2-stage knees had 54.9% success after the first attempt and 66.7% success after the second. Five of 5 hips treated with 1-stage arthroplasty succeeded after the first attempt, while 1 of 3 one-stage knees succeeded after the first attempt; none of these 8 joints had a hematogenous infection. No joints requiring a third treatment were successful after the third attempt. There were no differences in survival between different bacteria. Treatment of deep prosthetic joint infection is difficult once the first attempt has failed and becomes more so after failure of the second attempt. Two-stage arthroplasty provides good results in most cases (82% in hips, 67% in knees), but a third attempt does not increase these percentages. The organism type does not significantly affect success in infected joint treatment.
- Open Access
- 1 February 2010
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (2) , 441-447
High Survival of Uncemented Proximally Porous-coated Titanium Alloy Femoral Stems in Osteoporotic Bone
Because the initial fixation of an uncemented stem may be compromised in patients with osteoporotic bone (Class C, Dorr et al.), many surgeons prefer a cemented stem in this setting. We therefore determined the survival of an uncemented, proximally porous-coated, straight-stemmed, titanium alloy femoral component in patients with Class C bone when compared with Class A and B bone. We implanted proximally plasma-sprayed, straight-stemmed titanium alloy stems in 1994 patients (2321 hips). Of these, 625 hips (27%), 1569 hips (67%), and 127 hips (6%) were classified as Classes A, B, and C, respectively. Minimum followup was 2 years (mean, 5.9 years; range, 2–19.5 years). We identified no differences in Harris hip scores, pain, radiolucencies, or osteolysis among Classes A, B, and C hips. Stem survival at 5, 10, and 15 years for aseptic loosening (failure) was 100% in all patients with Class A bone; 99+% in all patients with Class B bone; and 100% in all patients with Class C bone. Initial stability and durable fixation can be achieved with the use of this uncemented stem in patients in whom a cemented stem traditionally has been preferred as a result of poor bone quality. Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 February 2010
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (2) , 441-447
Open AccessHigh Survival of Uncemented Proximally Porous-coated Titanium Alloy Femoral Stems in Osteoporotic Bone
Because the initial fixation of an uncemented stem may be compromised in patients with osteoporotic bone (Class C, Dorr et al.), many surgeons prefer a cemented stem in this setting. We therefore determined the survival of an uncemented, proximally porous-coated, straight-stemmed, titanium alloy femoral component in patients with Class C bone when compared with Class A and B bone. We implanted proximally plasma-sprayed, straight-stemmed titanium alloy stems in 1994 patients (2321 hips). Of these, 625 hips (27%), 1569 hips (67%), and 127 hips (6%) were classified as Classes A, B, and C, respectively. Minimum followup was 2 years (mean, 5.9 years; range, 2–19.5 years). We identified no differences in Harris hip scores, pain, radiolucencies, or osteolysis among Classes A, B, and C hips. Stem survival at 5, 10, and 15 years for aseptic loosening (failure) was 100% in all patients with Class A bone; 99+% in all patients with Class B bone; and 100% in all patients with Class C bone. Initial stability and durable fixation can be achieved with the use of this uncemented stem in patients in whom a cemented stem traditionally has been preferred as a result of poor bone quality. Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 June 2009
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91-B (6) , 745-749
The Anatomical Graduated Component total knee replacement
The long-term success of total knee replacement is multifactorial, including factors relating to the patient, the operation and the implant. The purpose of this study was to examine the 20-year survival of the cemented Anatomical Graduated Component (AGC) total knee replacement. Between 1983 and 2004, 7760 of these were carried out at our institution. Of these, 6726 knees which received the non-modular metal-backed tibial component with compression-moulded polyethylene and had a minimum two-year follow-up were available for study. In all, 36 knees were followed over 20 years with a survival of the tibial and femoral components together of 97.8% (95% confidence interval (CI) 0.9851 to 0.9677), with no implants being revised for polyethylene wear or osteolysis. Age > 70 was associated with increased survival (99.6%, 95% CI 99.0 to 99.8) (p < 0.0001) but pre-operative valgus alignment reduced survival (95.1%, 95% CI 90.0 to 97.6) (p = 0.0056). Age < 55 (p = 0.129), pre-operative varus alignment (p = 0.707), osteonecrosis (p = 0.06), rheumatoid arthritis (p = 0.247), and gender (p = 0.666) were not statistically associated with failure. We attribute the success of the AGC implant to its relatively unconstrained articular geometry and the durability of a non-modular metal-backed tibial component with compression moulded polyethylene.
- 1 June 2009
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91-B (6) , 745-749
The Anatomical Graduated Component total knee replacement
The long-term success of total knee replacement is multifactorial, including factors relating to the patient, the operation and the implant. The purpose of this study was to examine the 20-year survival of the cemented Anatomical Graduated Component (AGC) total knee replacement. Between 1983 and 2004, 7760 of these were carried out at our institution. Of these, 6726 knees which received the non-modular metal-backed tibial component with compression-moulded polyethylene and had a minimum two-year follow-up were available for study. In all, 36 knees were followed over 20 years with a survival of the tibial and femoral components together of 97.8% (95% confidence interval (CI) 0.9851 to 0.9677), with no implants being revised for polyethylene wear or osteolysis. Age > 70 was associated with increased survival (99.6%, 95% CI 99.0 to 99.8) (p < 0.0001) but pre-operative valgus alignment reduced survival (95.1%, 95% CI 90.0 to 97.6) (p = 0.0056). Age < 55 (p = 0.129), pre-operative varus alignment (p = 0.707), osteonecrosis (p = 0.06), rheumatoid arthritis (p = 0.247), and gender (p = 0.666) were not statistically associated with failure. We attribute the success of the AGC implant to its relatively unconstrained articular geometry and the durability of a non-modular metal-backed tibial component with compression moulded polyethylene.