MBMarschall B. Berkes

Marschall B. Berkes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marschall B. Berkes has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Structural Endosteal Augmentation for Proximal Humerus Fractures

    by Lionel E. Lazaro, Marschall B. Berkes, Dean G. Lorich

    Achieving both stable fixation and maintaining anatomic fracture reduction of displaced proximal humerus fractures are difficult tasks. Often, these fracture types are associated with poor bone quality with respect to the humeral head and are coupled with an inability to apply adequate buttress plating to the medial cortex. The effectiveness of locking implants in proximal humerus fractures is variable, despite a general efficiency in the treatment of osteoporotic fractures. Biomechanical and clinical data have demonstrated that mechanical support of the medial column is essential for successful patient outcomes. Endosteal augmentation, by means of a fibula strut allograft, incorporated to the locking plate construct provides the medial column the supplemental mechanical support and stability necessary to maintain an anatomic reduction.


  • Defining the Lateral and Accessory Views of the Patella

    by Marschall B. Berkes, Milton T. M. Little, Nadine C. Bs Pardee, Lionel E. Lazaro, David L. Helfet, Dean G. Lorich

    Objective: The majority of orthopaedic surgeons rely on a lateral fluoroscopic image to assess reduction during patella fracture osteosynthesis. However, a comprehensive radiographic description of the lateral view of the patella has not been performed previously, and no accessory views to better visualize specific anatomic features have been developed. The purpose of this study was to provide a detailed anatomic description of all radiographic features of the true lateral of the patella, describe reproducible accessory views for assessing specific features of the patella, and demonstrate their utility in a fracture model. Methods: Twelve cadaver knee specimens free of patellofemoral pathology were used, and imaging was performed using standard C-arm fluoroscopy. For each specimen, a true lateral radiographic projection of the patella was obtained and distinct features were noted. Next, an arthrotomy was made and steel wire was contoured and fixed to various anatomic regions of the patella so as to obliterate the radiographic densities on the true lateral projection, thus confirming their anatomic correlation. Ideal views of the lateral and medial facets themselves were determined using radiographic markers and varying amounts of internal or external rotation of the specimen. Last, a transverse osteotomy was created in each patella and the ability of the true lateral and accessory views to detect malreduction was assessed. Results: The true lateral projection of the patella was obtained with the limb in neutral alignment. Constant radiographic features of the lateral view of the patella include the articular tangent, a secondary articular density of variable length, and a dorsal cortical density. The articular tangent was produced by the central ridge between the medial and lateral facets in all specimens. The secondary articular density was created by a confluence of the edge of the lateral and edge of the medial facets in 5 patellas, a confluence of the edge of the lateral facet and the intersection of the odd and medial facets in 6 patellas, and the edge of the lateral facet alone in 1 patella. The edge of the lateral facet gave a constant contribution to the appearance of the secondary articular density in all cases. A distinct accessory view of the tangent of the lateral facet could be seen with an average of 17 degrees of patella external rotation (range, 12–35 degrees), and the tangent of the medial facet with an average of 26.5 degrees of internal rotation (range, 15–45 degrees). These accessory views were better able to visualize malreduction than the single lateral projection in a fracture model in all specimens. Conclusions: Described here is a comprehensive description of the true lateral radiographic view of the patella and accessory views. These views can be used in the evaluation of minimally displaced patella fractures if a computerized tomography is not desired to better assess the true amount of displacement and when assessing intraoperative reduction during patella fracture osteosynthesis.


  • Open reduction internal fixation of proximal humerus fractures

    by Marschall B. Berkes, Milton T. M. Little, Dean G. Lorich

    The treatment of proximal humerus fractures continues to evolve. While the many of these injuries can be managed nonoperatively, a certain percentage require operative treatment. Open reduction internal fixation can offer excellent outcomes when performed in the appropriate patient and utilizing proper techniques. This article reviews the most up-to-date literature regarding all phases of proximal humerus fracture osteosynthesis, including diagnosis, imaging, anatomic considerations, surgical indications, fixation, and surgical outcomes.


  • Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation

    by M. B. Berkes, M. T. M. Little, L. E. Lazaro, P. K. Sculco, R. M. Cymerman, M. Daigl, D. L. Helfet, D. G. Lorich

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.


  • Catastrophic Failure After Open Reduction Internal Fixation of Femoral Neck Fractures With a Novel Locking Plate Implant

    by Marschall B. Berkes, Milton T. M. Little, Lionel E. Lazaro, Rachel M. Ba Cymerman, David L. Helfet, Dean G. Lorich

    Objectives: To determine if the use of a novel proximal femoral locking plate could reduce the incidence of femoral neck shortening and improve clinical outcomes after open reduction internal fixation (ORIF) for femoral neck fractures as compared with historical controls. Design: Single surgeon, retrospective case–control study. Setting: Academic level I trauma center. Patients/Participants: Twenty-one femoral neck fractures treated with the posterolateral femoral locking plate (Synthes, Inc, Paoli, PA) were eligible for inclusion. Eighteen met inclusion/exclusion criteria with a mean follow-up of 16 months. Intervention: ORIF of femoral neck fracture with the posterolateral femoral locking plate. This consists of a side plate with multiple locking screws directed into the femoral head at converging/diverging angles and a single shaft screw. Intraoperative compression was achieved with partially threaded screws before locking screw insertion. Main Outcome Measurements: Maintenance of reduction was assessed by comparing immediate postoperative and final follow-up radiographs. Clinical outcome was assessed with Harris Hip Scores after 1 year. Complications and secondary operations were noted. Results: Seven (36.8%) of 18 patients experienced catastrophic failure. Five of these patients required total hip replacement, whereas the remaining 2 died before further treatment. The remaining 11 patients (61.1%) achieved bony union; the average displacement of the center of the head did not differ when compared with historical controls (0.78 mm inferiorly, 1.62 mm medially, and 2.4 degrees of increased varus vs. 0.86 mm, 1.23 mm, and 0.6 degree). Complications in this group include 1 instance of screw fracture, 2 total hip replacements, and a peri-implant subtrochanteric femur fracture. The average patient age and proportion of displaced fractures did not differ between the historical control and experimental groups. Fracture displacement was strongly associated with catastrophic failure in the experimental group only. Average Harris Hip Scores was significantly worse compared with that of historical controls (67.9 vs. 84.7, P = 0.05). Conclusions: ORIF of femoral neck fractures using a locking plate construct yielded unacceptably poor outcomes in this patient population. We hypothesize that the stiffness of this construct prevents any fracture site micromotion, placing the mechanical burden on the implant, which can result in failure at the bone–screw interface or fatigue failure of the implant itself. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


    • 1 April 2012
      • Vol. 41  (4) , 166-71

    Traumatic posterior hip instability and femoroacetabular impingement in athletes.

    by Marschall B Berkes, Michael B Cross, Michael K Shindle, Asheesh Bedi, Bryan T Kelly

    We describe 3 cases of posterior hip instability associated with femoroacetabular impingement. In each case, we obtained a detailed medical history, performed a physical examination, evaluated imaging, recorded intraoperative findings, and clinically followed the patient for 1 year. Two of the 3 patients sustained a traumatic posterior hip subluxation caused by noncontact injuries. All patients had decreased internal rotation on physical examination, radiographic evidence of acetabular retroversion, a cam lesion, an elevated α angle, and a posterior acetabular rim fracture with associated labral injury. All patients underwent hip arthroscopy and direct repair of the bony acetabular fragment using 3 to 5 suture anchors. One-year follow-up in all cases demonstrated good to excellent results and full return to activities without restriction. Patients with femoroacetabular impingement may be predisposed to traumatic posterior dislocation or subluxation and a concomitant posterior acetabular rim fracture with labral injury. We propose that FAI predisposed these athletes to posterior hip instability.


  • Locking and Non-locking Constructs Achieve Similar Radiographic and Clinical Outcomes for Internal Fixation of Intra-articular Distal Humerus Fractures

    by Marschall Berkes, Grant Garrigues, John Solic, Nathan Van Zeeland, Nader Shourbaji, Kim Brouwer, Jesse Jupiter, David Ruch, William T. Obremskey

    Background: Locking plates have been used increasingly for the management of distal humerus fractures. Studies that compare patient-centered outcomes between locking and non-locking fixation for distal humerus fractures are lacking. Questions/Purposes: The purposes of this study were to (1) determine whether locking plates offered superior fixation compared with non-locking plates for distal humerus fractures, (2) determine whether the use of locking plates was associated with fewer complications, and (3) determine whether locking plate use resulted in superior radiographic outcome compared with non-locking plates. Lastly, another aim was to determine the average cost difference associated with locking plate use versus non-locking plate use for distal humerus fracture fixation. Patients and Method: Demographic, clinical, and radiographic data including loss of fixation, range of motion, rate of infection, nonunion and reoperation, as well as measures of fixation were collected retrospectively and compared on 96 patients with surgically treated AO type 13C distal humerus fractures (65 locking, 31 non-locking) at 6-week and 6-month follow-up. Average costs of locking and non-locking constructs were calculated and compared. Results: Three in 96 (3.1%) of all cases experienced loss of fixation, with no difference between the two groups. There was no difference between locking and non-locking groups with regard to the rate of nonunion, infection, and reoperation at 6 weeks and 6 months. On average, locking plate constructs were 348% more expensive than non-locking constructs. Conclusion: While there are some significant differences in radiographic parameters and cost between locking and non-locking constructs for internal fixation of intra-articular distal humerus fractures, there were no statistically significant differences in clinical outcome.