FDFrank Dennerlein

Frank Dennerlein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Frank Dennerlein has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Approximate truncation robust computed tomography—ATRACT

    by Frank Dennerlein, Andreas Maier

    We present an approximate truncation robust algorithm to compute tomographic images (ATRACT). This algorithm targets at reconstructing volumetric images from cone-beam projections in scenarios where these projections are highly truncated in each dimension. It thus facilitates reconstructions of small subvolumes of interest, without involving prior knowledge about the object. Our method is readily applicable to medical C-arm imaging, where it may contribute to new clinical workflows together with a considerable reduction of x-ray dose. We give a detailed derivation of ATRACT that starts from the conventional Feldkamp filtered-backprojection algorithm and that involves, as one component, a novel original formula for the inversion of the two-dimensional Radon transform. Discretization and numerical implementation are discussed and reconstruction results from both, simulated projections and first clinical data sets are presented.


  • Infinite impulse response filtering for cone beam tomography

    by Karl Barth, Frank Dennerlein, Thomas Brunner, Andreas Fieselmann, Rainer Graumann

    In computed tomography (CT) or conebeam tomography (CBT), filtered backprojection (FBP) has been known as an efficient technique for reconstructing 3D-volumes from acquired projection data. Plain backprojection only would result in systematically blurred objects. To compensate for this blurring, convolution-based filters have been derived that are non-local and sampled with 2048 coefficients or more, dependent on the projection data size. This filtering operation can be classified as finite impulse response (FIR) filtering. In terms of image quality, ideally-derived kernels sometimes amplify too much the high frequency noise (e.g. due to X-ray quantum noise) from the input projections. In practice, regularized filters are often preferred, damping higher frequencies while preserving the sharpness and signal dynamics needed for the reconstructed 3D-objects. From discrete systems theory, another filter type with infinite impulse response (IIR) has been known. Because such a filter recursively uses backward components, it requires very few coefficients while the long-range filter effect is preserved. In the presented work, IIR filters have systematically been designed and tested. They have been adjusted for the correction of a blurring system transfer function as well as for high-frequency noise suppression. Image quality has carefully been inspected by reconstruction of phantom data and clinical cases. It has been found that the filtering step in CBT/FBP can be realized as a recursive filter only, i.e. in self-contained IIRnotation, including adaptions like e.g. apodisation. The number of filtering operations is significantly reduced hereby. So with IIR filtering an efficient alternative for FBP filtering is available.


  • Cone-beam artifact evaluation of the factorization method

    by Frank Dennerlein, Frédéric Noo

    Purpose: The authors investigate the CB artifact behavior of the factorization approach recently suggested for image reconstruction in circular cone-beam computed tomography. This investigation is carried out in a typical C-arm geometry and involves simulated data and for the first time also phantom and clinical CB data acquired with a commercially available angiographic system. Methods: The CB artifact level is first measured using quantitative figures-of-merit that are computed from the reconstructions of the mathematical FORBILD head phantom and of a modified disk phantom. The authors then show reconstructions from a physical thorax phantom and clinical head data sets for a visual assessment of image quality. The performance of the factorization method is primarily compared to that of short-scan FDK, but the authors also show the results obtained with the full-scan FDK and the virtual PI-line BPF method for the simulation studies, as a benchmark. Results: Quantitatively, the FORBILD head phantom reconstructions of both FDK methods show a spatially averaged bias of up to 1.2% in the axial slices about 9 cm away from the plane of the scan, which is placed 4 cm below the central slice through the phantom. The artifact level for the short-scan FDK method and the virtual PI-line BPF method noticeably depends on the scan orientation. The factorization approach can significantly reduce both, this dependency as well as the reconstruction bias. It also shows visually an improved quality of the clinical images compared to short-scan FDK, particularly close to the spine and in the subcranial regions of the clinical data sets. Conclusions: The factorization approach comes with noticeably lower reconstruction bias than the FDK methods and is least sensitive to the scan orientation among all considered short-scan methods. The data inconsistencies contained in the real data sets, such as scatter, beam hardening, or data truncation, show only little impact on the factorization results. Hence, in both, reconstructions from real and simulated data, the factorization method yields better image quality than short-scan FDK, albeit at the cost of some slight, directed high-frequency artifacts that are mostly visible in axial slices.


  • A model for filtered backprojection reconstruction artifacts due to time-varying attenuation values in perfusion C-arm CT

    by Andreas Fieselmann, Frank Dennerlein, Yu Deuerling-Zheng, Jan Boese, Rebecca Fahrig, Joachim Hornegger

    Filtered backprojection is the basis for many CT reconstruction tasks. It assumes constant attenuation values of the object during the acquisition of the projection data. Reconstruction artifacts can arise if this assumption is violated. For example, contrast flow in perfusion imaging with C-arm CT systems, which have acquisition times of several seconds per C-arm rotation, can cause this violation. In this paper, we derived and validated a novel spatio-temporal model to describe these kinds of artifacts. The model separates the temporal dynamics due to contrast flow from the scan and reconstruction parameters. We introduced derivative-weighted point spread functions to describe the spatial spread of the artifacts. The model allows prediction of reconstruction artifacts for given temporal dynamics of the attenuation values. Furthermore, it can be used to systematically investigate the influence of different reconstruction parameters on the artifacts. We have shown that with optimized redundancy weighting function parameters the spatial spread of the artifacts around a typical arterial vessel can be reduced by about 70%. Finally, an inversion of our model could be used as the basis for novel dynamic reconstruction algorithms that further minimize these artifacts.


  • Filtered backprojection reconstruction with depth-dependent filtering

    by Frank Dennerlein, Holger Kunze, Frederic Noo

    A direct filtered-backprojection (FBP) reconstruction algorithm is presented for circular cone-beam computed tomography (CB-CT) that allows the filter operation to be applied efficiently with shift-variant band-pass characteristics on the kernel function. Our algorithm is derived from the ramp-filter based FBP method of Feldkamp et al. and obtained by decomposing the ramp filtering into a convolution involving the Hilbert kernel (global operation) and a subsequent differentiation operation (local operation). The differentiation is implemented as a finite difference of two (Hilbert filtered) data samples and carried out as part of the backprojection step. The spacing between the two samples, which defines the low-pass characteristics of the filter operation, can thus be selected individually for each point in the image volume. We here define the sample spacing to follow the magnification of the divergent-beam geometry and thus obtain a novel, depth-dependent filtering algorithm for circular CB-CT. We evaluate this resulting algorithm using computer-simulated CB data and demonstrate that our algorithm yields results where spatial resolution and image noise are distributed much more uniformly over the field-of-view, compared to Feldkamp’s approach.


  • Truncation correction for oblique filtering lines

    by Stefan Hoppe, Joachim Hornegger, Günter Lauritsch, Frank Dennerlein, Frédéric Noo

    State‐of‐the‐art filtered backprojection (FBP) algorithms often define the filtering operation to be performed along oblique filtering lines in the detector. A limited scan field of view leads to the truncation of those filtering lines, which causes artifacts in the final reconstructed volume. In contrast to the case where filtering is performed solely along the detector rows, no methods are available for the case of oblique filtering lines. In this work, the authors present two novel truncation correction methods which effectively handle data truncation in this case. Method 1 (basic approach) handles data truncation in two successive preprocessing steps by applying a hybrid data extrapolation method, which is a combination of a water cylinder extrapolation and a Gaussian extrapolation. It is independent of any specific reconstruction algorithm. Method 2 (kink approach) uses similar concepts for data extrapolation as the basic approach but needs to be integrated into the reconstruction algorithm. Experiments are presented from simulated data of the FORBILD head phantom, acquired along a partial‐circle‐plus‐arc trajectory. The theoretically exact M‐line algorithm is used for reconstruction. Although the discussion is focused on theoretically exact algorithms, the proposed truncation correction methods can be applied to any FBP algorithm that exposes oblique filtering lines.


  • Exact and efficient cone-beam reconstruction algorithm for a short-scan circle combined with various lines

    by Frank Dennerlein, Alexander Katsevich, Guenter Lauritsch, Joachim Hornegger

    X-ray 3D rotational angiography based on C-arm systems has become a versatile and established tomographic imaging modality for high contrast objects in interventional environment. Improvements in data acquisition, e.g. by use of flat panel detectors, will enable C-arm systems to resolve even low-contrast details. However, further progress will be limited by the incompleteness of data acquisition on the conventional short-scan circular source trajectories. Cone artifacts, which result from that incompleteness, significantly degrade image quality by severe smearing and shading. To assure data completeness a combination of a partial circle with one or several line segments is investigated. A new and efficient reconstruction algorithm is deduced from a general inversion formula based on 3D Radon theory. The method is theoretically exact, possesses shift-invariant filtered backprojection (FBP) structure, and solves the long object problem. The algorithm is flexible in dealing with various circle and line configurations. The reconstruction method requires nothing more than the theoretically minimum length of scan trajectory. It consists of a conventional short-scan circle and a line segment approximately twice as long as the height of the region-of-interest. Geometrical deviations from the ideal source trajectory are considered in the implementation in order to handle data of real C-arm systems. Reconstruction results show excellent image quality free of cone artifacts. The proposed scan trajectory and reconstruction algorithm assure excellent image quality and allow low-contrast tomographic imaging with C-arm based cone-beam systems. The method can be implemented without any hardware modifications on systems commercially available today.