R. Laskin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
R. Laskin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
C A Paulsen
1 shared publicationD J Roger
1 shared publicationG Peersman
Hospital for Special Surgery, New York, NY 10021, USA
1 shared publicationG. Peersman
ACZA Campus Stuivenberg, Antwerp, Belgium
1 shared publicationJ Davis
1 shared publicationJ V Bono
New England Baptist Hospital, Boston, Massachusetts 02120
1 shared publication
Latest Publications
- Open Access
- 1 February 2006
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 2 (1) , 70-72
Prolonged Operative Time Correlates with Increased Infection Rate after Total Knee Arthroplasty
Risk stratification has proven to be a useful tool in surgical site infection prevention. The duration of the surgical procedure has been recommended for use in surgical site infection (SSI) risk stratification (Infect Control Hosp Epidemiol 20:247–248, 1999). A retrospective analysis of 6489 patients who underwent total knee replacement (TKR) between 1993 and 1999 assessed the association between the duration of the surgical procedure and the risk of postoperative infection. One hundred thirteen infected patients were matched with 236 controls, and nominal variables were statistically processed. Patients without infections ( n = 236) had surgery durations of 94 ± 28 min, and patients with infection ( n = 104) had durations of 127 ± 45 min ( p < 0.001). Operation time has positive correlations with weight ( r = 0.3, p < 0.001), body mass index ( r = 0.3, p < 0.001), and the total number of comorbidities ( r = 0.2, p < 0.001; n = 340). The results confirm that the duration of the surgical procedure can be used as a risk predictor for SSI in TKR.
- 1 February 2006
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 2 (1) , 70-72
Open AccessProlonged Operative Time Correlates with Increased Infection Rate after Total Knee Arthroplasty
Risk stratification has proven to be a useful tool in surgical site infection prevention. The duration of the surgical procedure has been recommended for use in surgical site infection (SSI) risk stratification (Infect Control Hosp Epidemiol 20:247–248, 1999). A retrospective analysis of 6489 patients who underwent total knee replacement (TKR) between 1993 and 1999 assessed the association between the duration of the surgical procedure and the risk of postoperative infection. One hundred thirteen infected patients were matched with 236 controls, and nominal variables were statistically processed. Patients without infections ( n = 236) had surgery durations of 94 ± 28 min, and patients with infection ( n = 104) had durations of 127 ± 45 min ( p < 0.001). Operation time has positive correlations with weight ( r = 0.3, p < 0.001), body mass index ( r = 0.3, p < 0.001), and the total number of comorbidities ( r = 0.2, p < 0.001; n = 340). The results confirm that the duration of the surgical procedure can be used as a risk predictor for SSI in TKR.
- 1 November 2001
- No. 392,p. 15-23
Infection in total knee replacement: a retrospective review of 6489 total knee replacements.
Six thousand four hundred eighty-nine knee replacements were done in 6120 patients at the authors' institution between 1993 and 1999. Operations were done in a theater with vertical laminar flow and with the surgical team using body exhaust suits. Of these knee replacements, 116 knees became infected and 113 were available for followup. One hundred of the infections occurred in patients undergoing primary knee replacement, whereas the remaining infections occurred in patients undergoing revision knee replacement. Ninety-seven of these knees (86%) had deep periprosthetic infections and the remaining 16 knees had superficial wound infections. One third of the deep infections occurred within the first 3 months after surgery and the remaining 2/3 occurred after 3 months. The overall early deep infection rate for patients undergoing a primary knee replacement was 0.39%, whereas the rate for patients undergoing a revision knee replacement was 0.97%. A cohort of noninfected knee replacements from patients matched for gender, age, and month of surgery was used as a control group. Those comorbidities that were statistically significant in increasing the risk of infection were prior open surgical procedures, immunosuppressive therapy, poor nutrition, hypokalemia, diabetes mellitus, obesity, and a history of smoking. Patients undergoing revision procedures had a statistically higher risk of infection than did patients undergoing primary surgeries. If the surgery took longer than 2.5 hours, the risk of infection was increased significantly. There was no change in the infection rate when the perioperative antibiotic prophylaxis was decreased from 48 to 24 hours after surgery. The predominant infectious organisms were gram-positive (Staphylococcus aureus, Staphylococcus epidermidis, and Streptococcus Group B). Twenty percent of the knees that were infected clinically had no organisms that could be identified. In each case, the patient had been treated empirically at another institution with antibiotics before a culture of the joint was obtained.
- 1 November 2001
- No. 392,p. 15-23
Infection in total knee replacement: a retrospective review of 6489 total knee replacements.
Six thousand four hundred eighty-nine knee replacements were done in 6120 patients at the authors' institution between 1993 and 1999. Operations were done in a theater with vertical laminar flow and with the surgical team using body exhaust suits. Of these knee replacements, 116 knees became infected and 113 were available for followup. One hundred of the infections occurred in patients undergoing primary knee replacement, whereas the remaining infections occurred in patients undergoing revision knee replacement. Ninety-seven of these knees (86%) had deep periprosthetic infections and the remaining 16 knees had superficial wound infections. One third of the deep infections occurred within the first 3 months after surgery and the remaining 2/3 occurred after 3 months. The overall early deep infection rate for patients undergoing a primary knee replacement was 0.39%, whereas the rate for patients undergoing a revision knee replacement was 0.97%. A cohort of noninfected knee replacements from patients matched for gender, age, and month of surgery was used as a control group. Those comorbidities that were statistically significant in increasing the risk of infection were prior open surgical procedures, immunosuppressive therapy, poor nutrition, hypokalemia, diabetes mellitus, obesity, and a history of smoking. Patients undergoing revision procedures had a statistically higher risk of infection than did patients undergoing primary surgeries. If the surgery took longer than 2.5 hours, the risk of infection was increased significantly. There was no change in the infection rate when the perioperative antibiotic prophylaxis was decreased from 48 to 24 hours after surgery. The predominant infectious organisms were gram-positive (Staphylococcus aureus, Staphylococcus epidermidis, and Streptococcus Group B). Twenty percent of the knees that were infected clinically had no organisms that could be identified. In each case, the patient had been treated empirically at another institution with antibiotics before a culture of the joint was obtained.
- 1 January 1995
- Vol. 8 (1) , 7
Tibial intramedullary alignment in total knee arthroplasty.
This article describes a study that assessed the accuracy of a tibial intramedullary alignment device in 44 adult cadaveric tibiae. The results suggest that greater accuracy is achieved if the device is inserted fully to the level of the distal epiphyseal scar and if used in the nonvalgus tibia. When seating of the tibial guide rod is incomplete or when the tibia has a valgus anatomic bow, cross-checking with extramedullary alignment devices is recommended to maximize accuracy of tibial component position.
- 1 January 1995
- Vol. 8 (1) , 7
Tibial intramedullary alignment in total knee arthroplasty.
This article describes a study that assessed the accuracy of a tibial intramedullary alignment device in 44 adult cadaveric tibiae. The results suggest that greater accuracy is achieved if the device is inserted fully to the level of the distal epiphyseal scar and if used in the nonvalgus tibia. When seating of the tibial guide rod is incomplete or when the tibia has a valgus anatomic bow, cross-checking with extramedullary alignment devices is recommended to maximize accuracy of tibial component position.