Joseph M. Conflitti
Research Subjects
Joseph M. Conflitti has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Gaurav Khanna
Scripps Clinic
1 shared publication - Jack Anavian
Department of Orthopaedics, Brown University, Rhode Island Hosp., 593 Eddy St., Providence, RI 02903, USA
1 shared publication M L Jr Chip Routt
From *ETMC Orthopedic Institute, Tyler, TX; the †University of Mississippi Medical Center, Department of Orthopedic Surgery, Jackson, MS; and ‡Harborview Medical Center, Department of Orthopedic Surgery, Seattle, WA
1 shared publicationMatt L Graves
From *ETMC Orthopedic Institute, Tyler, TX; the †University of Mississippi Medical Center, Department of Orthopedic Surgery, Jackson, MS; and ‡Harborview Medical Center, Department of Orthopedic Surgery, Seattle, WA
1 shared publication- Peter Alexander Cole
Department of Orthopaedic Surgery, Regions Hospital, St. Paul, Minnesota
1 shared publication - Trent S. Guthrie1 shared publication
Latest Publications
- 1 December 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (12) , 3371-3378
A Reliable Radiographic Measurement Technique for Extra-articular Scapular Fractures
Currently, neither well-defined nor standardized measurement techniques exist for assessing deformity of extra-articular scapular fractures. To properly evaluate these injuries, compare observations across studies, and make clinical decisions, a validated measurement protocol for evaluating scapular fractures is needed. We describe techniques to quantitatively characterize extra-articular scapular fracture deformity; evaluate the reliability of these characterizations in plain film radiographs and CT scans; and determine potential differences in the characterization of the deformity between the two imaging modalities. We evaluated injury radiographs and three-dimensional CT images of 45 patients with extra-articular scapular fracture. Techniques for measuring medial/lateral displacement, angulation, translation, glenopolar angle, and glenoid version were established and utilized in two trials, performed 6 weeks apart, by three observers. We determined descriptive statistics for each measurement parameter. Interobserver reliability based upon interclass correlation coefficients ranged from 0.36 to 0.76 for radiographs and from 0.48 to 0.87 for three-dimensional CT. Intraobserver reliability using Pearson r coefficient ranged from 0.60 to 0.75 for radiographs and 0.64 to 0.89 for three-dimensional CT. Both individual and pooled measurements for angulation and glenopolar angle were higher on three-dimensional CT versus radiographs. Our data suggest three-dimensional CT is more reliable than plain radiography in the assessment of scapula fracture displacement. Therefore, we believe this modality should be utilized if fracture deformity warrants surgical consideration and to adequately compare data across studies. Level IV, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 December 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (12) , 3371-3378
A Reliable Radiographic Measurement Technique for Extra-articular Scapular Fractures
Currently, neither well-defined nor standardized measurement techniques exist for assessing deformity of extra-articular scapular fractures. To properly evaluate these injuries, compare observations across studies, and make clinical decisions, a validated measurement protocol for evaluating scapular fractures is needed. We describe techniques to quantitatively characterize extra-articular scapular fracture deformity; evaluate the reliability of these characterizations in plain film radiographs and CT scans; and determine potential differences in the characterization of the deformity between the two imaging modalities. We evaluated injury radiographs and three-dimensional CT images of 45 patients with extra-articular scapular fracture. Techniques for measuring medial/lateral displacement, angulation, translation, glenopolar angle, and glenoid version were established and utilized in two trials, performed 6 weeks apart, by three observers. We determined descriptive statistics for each measurement parameter. Interobserver reliability based upon interclass correlation coefficients ranged from 0.36 to 0.76 for radiographs and from 0.48 to 0.87 for three-dimensional CT. Intraobserver reliability using Pearson r coefficient ranged from 0.60 to 0.75 for radiographs and 0.64 to 0.89 for three-dimensional CT. Both individual and pooled measurements for angulation and glenopolar angle were higher on three-dimensional CT versus radiographs. Our data suggest three-dimensional CT is more reliable than plain radiography in the assessment of scapula fracture displacement. Therefore, we believe this modality should be utilized if fracture deformity warrants surgical consideration and to adequately compare data across studies. Level IV, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 October 2010
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 24 (10) , 630-636
Radiographic Quantification and Analysis of Dysmorphic Upper Sacral Osseous Anatomy and Associated Iliosacral Screw Insertions
Objective: To quantify upper sacral dysmorphic osseous anatomy and assess its impact on second sacral segment iliosacral screw insertion. Design: Retrospective evaluation of a prospective trauma database. Setting: Regional Level I trauma center. Patients: Twenty-four patients with unstable posterior pelvic ring disruptions and sacral dysmorphism were evaluated radiographically and second segment (S2) screws were placed using a standard technique. Main Outcome Measurements: The sacral osseous pathway limits were measured using preoperative pelvic computed tomography at the upper and second sacral segments. The S2 screw location relative to the sacral nerve root tunnels and the maximum possible screw lengths for both S1 and S2 screws were evaluated with postoperative pelvic computed tomography. The S2 screw positions were graded as intraosseous, juxtaforaminal, or extruded. Preoperative and postoperative peripheral neurologic examinations were documented. Results: The dysmorphic S1 width available for screw insertion averaged 13.2 mm. The S2 pathway width averaged 15.2 mm. The maximum potential screw length for the dysmorphic S1 averaged 100.8 mm and for S2 measured 151.9 mm. Twenty of 24 patients with S2 screws were intraosseous and in four patients were juxtaforaminal. There were no extruded screws. There were no neurologic injuries. Conclusions: Dysmorphic S1 segments are anatomically competent for routine screw fixation. The S2 segment provides a larger osseous site for screw insertion than S1 in dysmorphic sacrums. Significantly longer screws are possible in S2 compared with the dysmorphic S1 segment. S2 iliosacral screws can be safely and accurately accomplished using a standard technique in patients with unstable posterior pelvic ring disruptions and sacral dysmorphism. Safe screw insertions avoid iatrogenic nerve root injuries.
- 1 October 2010
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 24 (10) , 630-636
Radiographic Quantification and Analysis of Dysmorphic Upper Sacral Osseous Anatomy and Associated Iliosacral Screw Insertions
Objective: To quantify upper sacral dysmorphic osseous anatomy and assess its impact on second sacral segment iliosacral screw insertion. Design: Retrospective evaluation of a prospective trauma database. Setting: Regional Level I trauma center. Patients: Twenty-four patients with unstable posterior pelvic ring disruptions and sacral dysmorphism were evaluated radiographically and second segment (S2) screws were placed using a standard technique. Main Outcome Measurements: The sacral osseous pathway limits were measured using preoperative pelvic computed tomography at the upper and second sacral segments. The S2 screw location relative to the sacral nerve root tunnels and the maximum possible screw lengths for both S1 and S2 screws were evaluated with postoperative pelvic computed tomography. The S2 screw positions were graded as intraosseous, juxtaforaminal, or extruded. Preoperative and postoperative peripheral neurologic examinations were documented. Results: The dysmorphic S1 width available for screw insertion averaged 13.2 mm. The S2 pathway width averaged 15.2 mm. The maximum potential screw length for the dysmorphic S1 averaged 100.8 mm and for S2 measured 151.9 mm. Twenty of 24 patients with S2 screws were intraosseous and in four patients were juxtaforaminal. There were no extruded screws. There were no neurologic injuries. Conclusions: Dysmorphic S1 segments are anatomically competent for routine screw fixation. The S2 segment provides a larger osseous site for screw insertion than S1 in dysmorphic sacrums. Significantly longer screws are possible in S2 compared with the dysmorphic S1 segment. S2 iliosacral screws can be safely and accurately accomplished using a standard technique in patients with unstable posterior pelvic ring disruptions and sacral dysmorphism. Safe screw insertions avoid iatrogenic nerve root injuries.