Ata George Kasis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ata George Kasis has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
M.J. Farhan
Orthopaedics Department, Bassetlaw Hospital, Worksop, Nottinghamshire - UK
2 shared publicationsR. Elson
Orthopaedics Department, Northern General Hospital, Sheffield - UK
2 shared publicationsAhmad M. Ali
Oldchurch Hospital, Waterloo Road, Romford, Essex RM7 0BE, UK
1 shared publicationAhmed Mubashir
Department of Orthopaedics and Trauma, Bassetlaw Hospital, Doncaster and Bassetlaw NHS Trust, Worksop, Nottinghamshire, UK
1 shared publicationBenjamin Ross Emmerson
Wansbeck General Hospital, Woodhorn Ln, Ashington, UK
1 shared publicationChandra K. Bhatia
1 shared publication
Latest Publications
- 1 April 2021
- Published by Springer Nature
- p. 997-1008
Stand-Alone Interbody Devices: Static Versus Dynamic
- 1 April 2021
- Published by Springer Nature
- p. 997-1008
Stand-Alone Interbody Devices: Static Versus Dynamic
- Open Access
- 15 February 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (5) , 1296-1302
Novel bone grafting technique in stand-alone ALIF procedure combining allograft and autograft (‘Northumbria Technique’)—Fusion rate and functional outcomes in 100 consecutive patients
Introduction: Successful ALIF surgery depends upon achieving solid fusion, whilst avoiding significant complications. Herein, we present the ‘Northumbria Technique’ of combining allograft with autograft in order to achieve solid interbody fusion. Materials and Methods: A single-surgeon series of 100 consecutive patients undergoing stand-alone ALIF from 2016 to 2019 was studied. All had percutaneously harvested iliac crest bone graft (ICBG) dowels inserted into blocks of fresh frozen femoral head (FFFH) allograft, which were then inserted into the ALIF cages. Patients had dynamic radiographs at 4 months, CT at 6 months, and patient reported outcome measure scores (PROMS) throughout. Results: One hundred patients (average age 44.8 years) were followed-up for an average of 29.1 months. Ninety-four (94%) patients were assessed as having fused on both CT and radiographs by an independent Radiologist. Three (3%) patients had abolition of movement on radiographs, but either lacked a CT scan or failed to meet Williams criteria for fusion. Two patients failed to attend for any imaging, so were considered not fused, and one patient had no evidence of fusion in either modality. There was a significant improvement in all PROMS. There were no intra-operative complications, and one patient had transient donor-site pain. Conclusions: The newly described ‘Northumbria Technique’ utilises the osteoconductive characteristics of the FFFH allograft, as well as the osteoinductive and osteogenic properties of the ICBG autograft. It gives high fusion rates (94–97%) and statistically significant improvements in PROMS, whilst avoiding the complications of harvesting a large amount of autograft and the huge costs of using synthetic agents.
- 15 February 2021
- Published by Springer Nature in European Spine Journal
- Vol. 30 (5) , 1296-1302
Open AccessNovel bone grafting technique in stand-alone ALIF procedure combining allograft and autograft (‘Northumbria Technique’)—Fusion rate and functional outcomes in 100 consecutive patients
Introduction: Successful ALIF surgery depends upon achieving solid fusion, whilst avoiding significant complications. Herein, we present the ‘Northumbria Technique’ of combining allograft with autograft in order to achieve solid interbody fusion. Materials and Methods: A single-surgeon series of 100 consecutive patients undergoing stand-alone ALIF from 2016 to 2019 was studied. All had percutaneously harvested iliac crest bone graft (ICBG) dowels inserted into blocks of fresh frozen femoral head (FFFH) allograft, which were then inserted into the ALIF cages. Patients had dynamic radiographs at 4 months, CT at 6 months, and patient reported outcome measure scores (PROMS) throughout. Results: One hundred patients (average age 44.8 years) were followed-up for an average of 29.1 months. Ninety-four (94%) patients were assessed as having fused on both CT and radiographs by an independent Radiologist. Three (3%) patients had abolition of movement on radiographs, but either lacked a CT scan or failed to meet Williams criteria for fusion. Two patients failed to attend for any imaging, so were considered not fused, and one patient had no evidence of fusion in either modality. There was a significant improvement in all PROMS. There were no intra-operative complications, and one patient had transient donor-site pain. Conclusions: The newly described ‘Northumbria Technique’ utilises the osteoconductive characteristics of the FFFH allograft, as well as the osteoinductive and osteogenic properties of the ICBG autograft. It gives high fusion rates (94–97%) and statistically significant improvements in PROMS, whilst avoiding the complications of harvesting a large amount of autograft and the huge costs of using synthetic agents.
- 7 October 2019
- Published by Springer Nature
- p. 1-12
Stand-Alone Interbody Devices: Static Versus Dynamic
- 7 October 2019
- Published by Springer Nature
- p. 1-12
Stand-Alone Interbody Devices: Static Versus Dynamic
- 1 March 2009
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (6) , 572-577
Significantly Improved Outcomes With a Less Invasive Posterior Lumbar Interbody Fusion Incorporating Total Facetectomy
Original study. Prospective comparison of clinical outcomes after a standard posterior lumbar interbody fusion (ST-PLIF) and after a limited exposure PLIF incorporating total facetectomy (LI-PLIF). Most groups have reported significantly improved clinical outcomes after ST-PLIF. To our knowledge, however, a comparison of outcomes between ST-PLIF and the LI-PLIF that we herein describe has not been reported before. Patients were included who had suffered chronic low back pain for a minimum of 2 years that was unresponsive to conservative treatment. N = 114 consecutive patients underwent ST-PLIF, whereas n = 209 underwent LI-PLIF. All patients underwent pre- and postoperative evaluations for Oswestry Disability Index (ODI), short-form 36 (SF-36), and visual analogue scores (VAS). The minimum follow-up for either group was 2 years. There was a significant improvement in the ODI (22.5 +/- 1.0, P < 0.001), VAS for back pain (3.8 +/- 0.1, P = 0.003), VAS for leg pain (4.0 +/- 0.2, P = 0.002), and SF-36 for bodily pain (14.7 +/- 0.9, P = 0.012) after ST-PLIF. However, there was a significantly greater improvement in all scores after LI-PLIF: ODI (28.8 +/- 1.4 vs. 22.5 +/- 1.0, P < 0.001), VAS for back pain (5.4 +/- 0.2 vs. 3.8 +/- 0.1, P = 0.001), VAS for leg pain (5.1 +/- 0.2 vs. 4.0 +/- 0.2, P < 0.001), and SF-36 for bodily pain (18.5 +/- 0.8 vs. 14.7 +/- 0.9, P = 0.003). There was a significantly shorter duration of hospital stay after LI-PLIF (2.24 +/- 0.057 days) than after ST-PLIF (4.04 +/- 0.13 days) (P = 0.005). Operative complications occurred in 19.3% of ST-PLIF and in 6.7% of LI-PLIF. Clinical outcomes were significantly improved after both ST-PLIF and LI-PLIF. However, outcomes were significantly better after LI-PLIF than after ST-PLIF. Significantly shortened hospital stay with LI-PLIF probably reflected the "less invasive" technique per se. Significantly better clinical outcomes with fewer complications after LI-PLIF, however, potentially reflected maneuvers singular to LI-PLIF: (1) preservation of posterior elements, (2) avoidance of far lateral dissection over the transverse processes, (3) bilateral total facetectomy, (4) fewer neurologic complications, and (5) avoidance of iliac crest autograft. LI-PLIF is therefore recommended over ST-PLIF.
- 1 March 2009
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (6) , 572-577
Significantly Improved Outcomes With a Less Invasive Posterior Lumbar Interbody Fusion Incorporating Total Facetectomy
Original study. Prospective comparison of clinical outcomes after a standard posterior lumbar interbody fusion (ST-PLIF) and after a limited exposure PLIF incorporating total facetectomy (LI-PLIF). Most groups have reported significantly improved clinical outcomes after ST-PLIF. To our knowledge, however, a comparison of outcomes between ST-PLIF and the LI-PLIF that we herein describe has not been reported before. Patients were included who had suffered chronic low back pain for a minimum of 2 years that was unresponsive to conservative treatment. N = 114 consecutive patients underwent ST-PLIF, whereas n = 209 underwent LI-PLIF. All patients underwent pre- and postoperative evaluations for Oswestry Disability Index (ODI), short-form 36 (SF-36), and visual analogue scores (VAS). The minimum follow-up for either group was 2 years. There was a significant improvement in the ODI (22.5 +/- 1.0, P < 0.001), VAS for back pain (3.8 +/- 0.1, P = 0.003), VAS for leg pain (4.0 +/- 0.2, P = 0.002), and SF-36 for bodily pain (14.7 +/- 0.9, P = 0.012) after ST-PLIF. However, there was a significantly greater improvement in all scores after LI-PLIF: ODI (28.8 +/- 1.4 vs. 22.5 +/- 1.0, P < 0.001), VAS for back pain (5.4 +/- 0.2 vs. 3.8 +/- 0.1, P = 0.001), VAS for leg pain (5.1 +/- 0.2 vs. 4.0 +/- 0.2, P < 0.001), and SF-36 for bodily pain (18.5 +/- 0.8 vs. 14.7 +/- 0.9, P = 0.003). There was a significantly shorter duration of hospital stay after LI-PLIF (2.24 +/- 0.057 days) than after ST-PLIF (4.04 +/- 0.13 days) (P = 0.005). Operative complications occurred in 19.3% of ST-PLIF and in 6.7% of LI-PLIF. Clinical outcomes were significantly improved after both ST-PLIF and LI-PLIF. However, outcomes were significantly better after LI-PLIF than after ST-PLIF. Significantly shortened hospital stay with LI-PLIF probably reflected the "less invasive" technique per se. Significantly better clinical outcomes with fewer complications after LI-PLIF, however, potentially reflected maneuvers singular to LI-PLIF: (1) preservation of posterior elements, (2) avoidance of far lateral dissection over the transverse processes, (3) bilateral total facetectomy, (4) fewer neurologic complications, and (5) avoidance of iliac crest autograft. LI-PLIF is therefore recommended over ST-PLIF.
- Open Access
- 4 April 2008
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 3 (1) , 35-38
External fixator-assisted acute shortening with internal fixation for leg length discrepancy after total hip replacement
We report a case of a 51-year-old lady, who underwent a femoral shortening using a fixator assisted blade plate after total hip replacement. The patient had a total hip replacement on the other side with previous revisions, which resulted in a leg length discrepancy. We used the above technique to control the shortening and preserve the mechanical and anatomical axis of the femur.
- 4 April 2008
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 3 (1) , 35-38
Open AccessExternal fixator-assisted acute shortening with internal fixation for leg length discrepancy after total hip replacement
We report a case of a 51-year-old lady, who underwent a femoral shortening using a fixator assisted blade plate after total hip replacement. The patient had a total hip replacement on the other side with previous revisions, which resulted in a leg length discrepancy. We used the above technique to control the shortening and preserve the mechanical and anatomical axis of the femur.
- Open Access
- 1 April 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (2) , 82-87
A Radiological Study of 3M Capital Femoral Hip Prostheses: An Analysis of Factors Predisposing to Failure
We conducted a radiographic assessment of 180 flanged modular titanium alloy Capital femoral hip replacements. Six significant factors associated with failure are identified. The mean follow-up period was 7.9 years (2.1–16 years) and there were 26 (14%) radiographic failures irrespective of whether these were symptomatic or led to revision. Failure, if it is going to occur, is initiated early, within an average of 1.4 years, and becomes clinically evident very quickly; the remainder appear to sustain more likelihood of stable survival. This is the longest published follow-up and it suggests that the survival is better than indicated in some other series. If the identified prejudicial aspects of surgical technique had not been present, it follows that the results would have been better. Comparison with other published series is attempted.
- 1 April 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (2) , 82-87
Open AccessA Radiological Study of 3M Capital Femoral Hip Prostheses: An Analysis of Factors Predisposing to Failure
We conducted a radiographic assessment of 180 flanged modular titanium alloy Capital femoral hip replacements. Six significant factors associated with failure are identified. The mean follow-up period was 7.9 years (2.1–16 years) and there were 26 (14%) radiographic failures irrespective of whether these were symptomatic or led to revision. Failure, if it is going to occur, is initiated early, within an average of 1.4 years, and becomes clinically evident very quickly; the remainder appear to sustain more likelihood of stable survival. This is the longest published follow-up and it suggests that the survival is better than indicated in some other series. If the identified prejudicial aspects of surgical technique had not been present, it follows that the results would have been better. Comparison with other published series is attempted.
- 1 January 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (2) , 82-87
A radiological study of 3M Capital femoral hip prostheses: an analysis of factors predisposing to failure
We conducted a radiographic assessment of 180 flanged modular titanium alloy Capital femoral hip replacements. Six significant factors associated with failure are identified. The mean follow-up period was 7.9 years (2.1-16 years) and there were 26 (14%) radiographic failures irrespective of whether these were symptomatic or led to revision. Failure, if it is going to occur, is initiated early, within an average of 1.4 years, and becomes clinically evident very quickly; the remainder appear to sustain more likelihood of stable survival. This is the longest published follow-up and it suggests that the survival is better than indicated in some other series. If the identified prejudicial aspects of surgical technique had not been present, it follows that the results would have been better. Comparison with other published series is attempted.
- 1 January 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (2) , 82-87
A radiological study of 3M Capital femoral hip prostheses: an analysis of factors predisposing to failure
We conducted a radiographic assessment of 180 flanged modular titanium alloy Capital femoral hip replacements. Six significant factors associated with failure are identified. The mean follow-up period was 7.9 years (2.1-16 years) and there were 26 (14%) radiographic failures irrespective of whether these were symptomatic or led to revision. Failure, if it is going to occur, is initiated early, within an average of 1.4 years, and becomes clinically evident very quickly; the remainder appear to sustain more likelihood of stable survival. This is the longest published follow-up and it suggests that the survival is better than indicated in some other series. If the identified prejudicial aspects of surgical technique had not been present, it follows that the results would have been better. Comparison with other published series is attempted.
- 1 April 2004
- Published by Springer Nature in European Journal of Trauma
- Vol. 30 (2) , 127-129
Isolated Salter-Harris Type IV Fracture of the Distal Ulna in a 12-Year-Old Boy
- 1 April 2004
- Published by Springer Nature in European Journal of Trauma
- Vol. 30 (2) , 127-129
Isolated Salter-Harris Type IV Fracture of the Distal Ulna in a 12-Year-Old Boy