Karl-Heinz Frosch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Karl-Heinz Frosch has a total of 362 co-authors. Here are the top co-authors by number of shared publications:
K. M. Stürmer
Georg-August-University Goettingen
3 shared publicationsK.M. Stürmer
Universitätsmedizin Göttingen, Robert-Koch-Straße 40, 37075 Göttingen, Germany
3 shared publicationsC Dumont
2 shared publicationsD Kubein-Meesenburg
2 shared publicationsD. Kubein-Meesenburg
Abteilung Kieferorthopädie, Universitätsmedizin Göttingen, Göttingen, Deutschland
2 shared publicationsH. Nägerl
Biomechanische Arbeitsgruppe Göttingen/Greifswald, Abteilung Kieferorthopädie, Universitätsmedizin Göttingen, Göttingen, Deutschland
2 shared publications
Latest Publications
- 31 December 2009
- Published by Elsevier in Sports Orthopaedics and Traumatology
- Vol. 25 (2) , 129-130
V 14 Defizit der Streck- und Beugekraft nach vorderer Kreuzbandplastik – Vergleich von Semitendinosussehne versus Semitendinosus- und Gracilissehne
- 31 December 2009
- Published by Elsevier in Sports Orthopaedics and Traumatology
- Vol. 25 (2) , 129-130
V 14 Defizit der Streck- und Beugekraft nach vorderer Kreuzbandplastik – Vergleich von Semitendinosussehne versus Semitendinosus- und Gracilissehne
- 1 December 2009
- p. 69-72
Knee motion analysis of the non-loaded and loaded knee: a re-look at rolling and sliding.
Many studies of knee motion have been reported in the literature over more than 100 years. Of particular interest to the analysis presented here is the work of the Freeman group, who elegantly measured tibio-femoral kinematics in studies made on cadavers and the knees of living individuals using MRI, anatomical dissection and RSA. We examined and re-evaluated the data collected by Freeman's group and suggest that their conclusion should be considered to be incorrect, since their methods of evaluation were oversimplified from the mathematical and physical perspectives. By applying appropriate methods, however, it is possible to show that the same data yield important insights into physiological knee kinematics and reveal that the rolling-sliding relationship depends on the degree of flexion and on joint load in the medial and lateral compartment, as well. In the initial range of flexion, a considerable amount of rolling was found to occur. Based on this analysis, it is possible to gain useful insights of value for the design of total knee replacements.
- 1 December 2009
- p. 69-72
Knee motion analysis of the non-loaded and loaded knee: a re-look at rolling and sliding.
Many studies of knee motion have been reported in the literature over more than 100 years. Of particular interest to the analysis presented here is the work of the Freeman group, who elegantly measured tibio-femoral kinematics in studies made on cadavers and the knees of living individuals using MRI, anatomical dissection and RSA. We examined and re-evaluated the data collected by Freeman's group and suggest that their conclusion should be considered to be incorrect, since their methods of evaluation were oversimplified from the mathematical and physical perspectives. By applying appropriate methods, however, it is possible to show that the same data yield important insights into physiological knee kinematics and reveal that the rolling-sliding relationship depends on the degree of flexion and on joint load in the medial and lateral compartment, as well. In the initial range of flexion, a considerable amount of rolling was found to occur. Based on this analysis, it is possible to gain useful insights of value for the design of total knee replacements.
- Open Access
- 21 August 2009
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 4 (2) , 73-79
Magnetic resonance imaging analysis of the bioabsorbable Milagro™ interference screw for graft fixation in anterior cruciate ligament reconstruction
Ligament graft fixation with bioabsorbable interference screws is a standard procedure in cruciate ligament replacement. Previous screw designs may resorb incompletely, and can cause osteolysis and sterile cysts despite being implanted for several years. The aim of this study was to examine the in vivo degradation and biocompatibility of the new Milagro™ interference screw (Mitek, Norderstedt, Germany). The Milagro™ interference screw is made of 30% ß-TCP (TriCalcium phosphate) and 70% PLGA (Poly-lactic-co-glycolic acid). In the period between June 2005 and February 2006, 38 patients underwent graft fixation with Milagro™ screws in our hospital. Arthroscopic ACL reconstruction was performed using hamstring tendon grafts in all the patients. MR imaging was performed on 12 randomly selected patients out of the total of 38 at 3, 6 and 12 months after surgery. During the examination, the volume loss of the screw, tunnel enlargement, presence of osteolysis, fluid lines, edema and postoperative screw replacement by bone tissue were evaluated. There was no edema or signs of inflammation around the bone tunnels. At 3, 6 and 12 months, the tibial screws showed an average volume loss of 0, 8.1% (±7.9%) and 82.6% (±17.2%, P < 0.05), respectively. The femoral screws showed volume losses of 2.5% (±2.1%), 31.3% (±21.6%) and 92.02% (±6.3%, P < 0.05), respectively. The femoral tunnel enlargement was 47.4% (±43.8%) of the original bone tunnel volume after 12 months, and the mean tunnel volume of the tibial tunnel was −9.5% (±58.1%) compared to the original tunnel. Bone ingrowth was observed in all the patients. In conclusion, the resorption behaviour of the Milagro™ screw is closely linked to the graft healing process. The screws were rapidly resorbed after 6 months and, at 12 months, only the screw remnants were detectable. Moreover, the Milagro™ screw is biocompatible and osteoconductive, promoting bone ingrowth during resorption. Tunnel enlargement is not prevented in the first months but is reduced by bone ingrowth after 12 months.
- 21 August 2009
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 4 (2) , 73-79
Open AccessMagnetic resonance imaging analysis of the bioabsorbable Milagro™ interference screw for graft fixation in anterior cruciate ligament reconstruction
Ligament graft fixation with bioabsorbable interference screws is a standard procedure in cruciate ligament replacement. Previous screw designs may resorb incompletely, and can cause osteolysis and sterile cysts despite being implanted for several years. The aim of this study was to examine the in vivo degradation and biocompatibility of the new Milagro™ interference screw (Mitek, Norderstedt, Germany). The Milagro™ interference screw is made of 30% ß-TCP (TriCalcium phosphate) and 70% PLGA (Poly-lactic-co-glycolic acid). In the period between June 2005 and February 2006, 38 patients underwent graft fixation with Milagro™ screws in our hospital. Arthroscopic ACL reconstruction was performed using hamstring tendon grafts in all the patients. MR imaging was performed on 12 randomly selected patients out of the total of 38 at 3, 6 and 12 months after surgery. During the examination, the volume loss of the screw, tunnel enlargement, presence of osteolysis, fluid lines, edema and postoperative screw replacement by bone tissue were evaluated. There was no edema or signs of inflammation around the bone tunnels. At 3, 6 and 12 months, the tibial screws showed an average volume loss of 0, 8.1% (±7.9%) and 82.6% (±17.2%, P < 0.05), respectively. The femoral screws showed volume losses of 2.5% (±2.1%), 31.3% (±21.6%) and 92.02% (±6.3%, P < 0.05), respectively. The femoral tunnel enlargement was 47.4% (±43.8%) of the original bone tunnel volume after 12 months, and the mean tunnel volume of the tibial tunnel was −9.5% (±58.1%) compared to the original tunnel. Bone ingrowth was observed in all the patients. In conclusion, the resorption behaviour of the Milagro™ screw is closely linked to the graft healing process. The screws were rapidly resorbed after 6 months and, at 12 months, only the screw remnants were detectable. Moreover, the Milagro™ screw is biocompatible and osteoconductive, promoting bone ingrowth during resorption. Tunnel enlargement is not prevented in the first months but is reduced by bone ingrowth after 12 months.
- 27 February 2009
- Published by Springer Nature in Der Unfallchirurg
- Vol. 112 (2) , 176-184
Eine neuartige Kniegelenksendoprothese mit physiologischer Gelenkform
- 27 February 2009
- Published by Springer Nature in Der Unfallchirurg
- Vol. 112 (2) , 176-184
Eine neuartige Kniegelenksendoprothese mit physiologischer Gelenkform
- 1 February 2009
- Published by Springer Nature in Der Unfallchirurg
- Vol. 112 (2) , 168-175
Eine neuartige Knieendoprothese mit physiologischer Gelenkform
- 1 February 2009
- Published by Springer Nature in Der Unfallchirurg
- Vol. 112 (2) , 168-175
Eine neuartige Knieendoprothese mit physiologischer Gelenkform
- 1 January 2008
- Vol. 10 (1) , 55-60
A novel total knee replacement by rolling articulating surfaces. In vivo functional measurements and tests.
The purposes of the paper were as follows: to show the fundamental functional differences between the natural knee and common total knee replacements (TKR), to describe the ideas on how main properties of the natural knee can be adopted by a novel TKR and to present some main biomechanical functions of this TKR. By analyzing the morphology of the articulating surfaces and the kinematics of the natural knee the design of the novel TKR was developed. The use was made of the test procedures established in vitro and of lateral X-ray photographs as well as fluoroscopy in vivo. The function of the novel TKR is comparable to that of the natural knee joint in terms of kinematics (roll/slide behaviour), loads of the articulating surfaces (diminished shear loads), stability and leeway under external impacts, reduction of the load in the patellofemoral joint, and ligament balancing.
- 1 January 2008
- Vol. 10 (1) , 55-60
A novel total knee replacement by rolling articulating surfaces. In vivo functional measurements and tests.
The purposes of the paper were as follows: to show the fundamental functional differences between the natural knee and common total knee replacements (TKR), to describe the ideas on how main properties of the natural knee can be adopted by a novel TKR and to present some main biomechanical functions of this TKR. By analyzing the morphology of the articulating surfaces and the kinematics of the natural knee the design of the novel TKR was developed. The use was made of the test procedures established in vitro and of lateral X-ray photographs as well as fluoroscopy in vivo. The function of the novel TKR is comparable to that of the natural knee joint in terms of kinematics (roll/slide behaviour), loads of the articulating surfaces (diminished shear loads), stability and leeway under external impacts, reduction of the load in the patellofemoral joint, and ligament balancing.
- 1 June 2007
- Published by Springer Nature in Der Unfallchirurg
- Vol. 110 (6) , 521-527
Die supraacetabuläre Beckenzwinge
The anatomic region on the lateral cortex of the ileum, where a palpable groove is formed by angulations of the lateral cortex of the iliac wing, is recommended as the insertion point for the pelvic emergency clamp by many authors. In our opinion this technique often leads to an incomplete closure of the anterior pelvic ring as well as to bacterial contamination of the access for the sacroiliac joint screw fixation and is accompanied by a risk for nerve and vessel injuries. To reduce these risks the pelvic clamp was placed at a supra-acetabular location. The goal of our study was to report on our experiences with the supra-acetabular position of the pelvic emergency clamp and to compare our results with the current literature. From September 1998 to February 2006 the pelvic emergency clamp was applied in 15 polytraumatized patients (9 male, 6 female), with a mean age of 46 years (19-93) and a mean injury severity score (ISS) of 40 points (25-66) with mechanically and hemodynamically unstable pelvic ring fractures. According to the AO classification the injury pattern was type B2 in four cases, type B3 in one case, type C1 in seven cases, type C2 in two cases and type C3 in one case. The pelvic clamp was percutaneously applied 2-3 cm cranial to the acetabular roof. The duration from hospital admission until the pelvic emergency clamp was applied amounted to an average of 54 min (15-150); the procedure itself was performed in all cases in less than 15 min. The mean Hb at arrival in the emergency department was 7.4 (2.4-13.8) mg/dl and the mean systolic blood pressure 69 (0-130) mmHg. In 14 patients a complete closure of the anterior and posterior pelvic ring could be achieved; in 1 patient an overcompression of the anterior pelvic ring was observed. Four patients died due to massive bleeding. Three patients with isolated pelvic ring fractures became hemodynamically stable within 20 min after treatment with the supra-acetabular pelvic clamp. Nine patients needed additional emergency surgery because of intracerebral, intrathoracic or intra-abdominal injuries. On average in the first 6 h, 36.7 (9-175) units of erythrocyte concentrates and 34.5 (4-200) units of fresh frozen plasma were transfused. The supra-acetabular pelvic clamp leads to a homogeneous force distribution to the pelvic ring and enables complete closure of the anterior and posterior pelvic ring in unstable pelvic fractures. Reduction of the intrapelvic volume and compression of the posterior pelvic ring can thus be achieved. Risks for intrapelvic perforation or injuries of vessels and nerves are low. No bacterial contamination of the access for the sacroiliac screw fixation occurs. To avoid overcompression of the unstable pelvic ring, manual or radiological control of the closure of the ventral pelvic ring is necessary.
- 1 June 2007
- Published by Springer Nature in Der Unfallchirurg
- Vol. 110 (6) , 521-527
Die supraacetabuläre Beckenzwinge
The anatomic region on the lateral cortex of the ileum, where a palpable groove is formed by angulations of the lateral cortex of the iliac wing, is recommended as the insertion point for the pelvic emergency clamp by many authors. In our opinion this technique often leads to an incomplete closure of the anterior pelvic ring as well as to bacterial contamination of the access for the sacroiliac joint screw fixation and is accompanied by a risk for nerve and vessel injuries. To reduce these risks the pelvic clamp was placed at a supra-acetabular location. The goal of our study was to report on our experiences with the supra-acetabular position of the pelvic emergency clamp and to compare our results with the current literature. From September 1998 to February 2006 the pelvic emergency clamp was applied in 15 polytraumatized patients (9 male, 6 female), with a mean age of 46 years (19-93) and a mean injury severity score (ISS) of 40 points (25-66) with mechanically and hemodynamically unstable pelvic ring fractures. According to the AO classification the injury pattern was type B2 in four cases, type B3 in one case, type C1 in seven cases, type C2 in two cases and type C3 in one case. The pelvic clamp was percutaneously applied 2-3 cm cranial to the acetabular roof. The duration from hospital admission until the pelvic emergency clamp was applied amounted to an average of 54 min (15-150); the procedure itself was performed in all cases in less than 15 min. The mean Hb at arrival in the emergency department was 7.4 (2.4-13.8) mg/dl and the mean systolic blood pressure 69 (0-130) mmHg. In 14 patients a complete closure of the anterior and posterior pelvic ring could be achieved; in 1 patient an overcompression of the anterior pelvic ring was observed. Four patients died due to massive bleeding. Three patients with isolated pelvic ring fractures became hemodynamically stable within 20 min after treatment with the supra-acetabular pelvic clamp. Nine patients needed additional emergency surgery because of intracerebral, intrathoracic or intra-abdominal injuries. On average in the first 6 h, 36.7 (9-175) units of erythrocyte concentrates and 34.5 (4-200) units of fresh frozen plasma were transfused. The supra-acetabular pelvic clamp leads to a homogeneous force distribution to the pelvic ring and enables complete closure of the anterior and posterior pelvic ring in unstable pelvic fractures. Reduction of the intrapelvic volume and compression of the posterior pelvic ring can thus be achieved. Risks for intrapelvic perforation or injuries of vessels and nerves are low. No bacterial contamination of the access for the sacroiliac screw fixation occurs. To avoid overcompression of the unstable pelvic ring, manual or radiological control of the closure of the ventral pelvic ring is necessary.
- 1 April 2006
- Published by Springer Nature in European Journal of Trauma
- Vol. 32 (2) , 149-159
Metallic Biomaterials in Skeletal Repair
- 1 April 2006
- Published by Springer Nature in European Journal of Trauma
- Vol. 32 (2) , 149-159
Metallic Biomaterials in Skeletal Repair
- 1 April 2006
- Published by Elsevier in Biomaterials
- Vol. 27 (12) , 2542-2549
Stem cell-coated titanium implants for the partial joint resurfacing of the knee
- 1 April 2006
- Published by Elsevier in Biomaterials
- Vol. 27 (12) , 2542-2549
Stem cell-coated titanium implants for the partial joint resurfacing of the knee
- 1 January 2000
- Published by Springer Nature
- p. 473-578
Postersession VI-Soft Tissue/Knorpel