WHWilliam J. Hozack

William J. Hozack

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William J. Hozack has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Surgical Approaches of the Hip

    by Eustathios Kenanidis, Dimitrios Rigkos, Georgios Paparoidamis, Aristotelis Yfantis, Zakareya Gamie, Eleftherios Tsiridis, Michael J. Feldstein, William Hozack


  • Total Knee Replacement with Prenavigation and Custom Cutting Blocks

    by William J. Hozack, Michael R. Bloomfield, Navin Fernando

  • Open Access

    The 2012 Chitranjan Ranawat Award: Intraarticular Analgesia After TKA Reduces Pain: A Randomized, Double-blinded, Placebo-controlled, Prospective Study

    by Nitin Goyal, James McKenzie, Peter F. Sharkey, Javad Parvizi, William J. Hozack, Matthew S. Austin

    Postoperative pain after total knee arthroplasty remains one of the most important challenges facing patients undergoing this surgery. Providing a balance of adequate analgesia while limiting the functional impact of regional anesthesia and minimizing opioid side effects is critical to minimize adverse events and improve patient satisfaction.


  • In Reply

    by Camilo Restrepo, Javad Parvizi, Aidin Eslam Pour, William J. Hozack

  • Modular Femoral Stems for Revision Total Hip Arthroplasty

    by Camilo Restrepo, Magdalena Mashadi, Javad Parvizi, Matthew S. Austin, William J. Hozack

    Ese issues. Questions/purposes We evaluated functional outcomes with a revision modular system and determined whether such a system achieved initial distal fixation, femoral offset restoration, leg length equalization, and hip stability. Methods We prospectively followed 118 patients in whom a modular stem system was used for reconstruction of their failed index femoral stem. Sixty-nine hips were classified as Type I (classification of Paprosky et al.), 35 as Type II, 17 as Type III, and one as Type IV. Functional assessment was achieved using patient- and physician-administered outcome evaluations (SF-36, WOMAC, Lower Extremity Activity Scale, Harris hip score). Stem fixation, offset restoration, leg length discrepancy, and hip stability were evaluated radiographically. Complications were also recorded. Minimum followup was 2 years (average, 4 years; range, 2-7 years). Results Average values on all functional outcome evaluations showed improvement at latest followup. Distal bone ingrowth fixation was obtained in 100% of the patients, offset was corrected in 66%, leg length discrepancy was corrected in 78%, and stability was achieved in 97%. No failures or fractures at the body to stem junction were seen at latest followup. Conclusions Modular femoral components achieved functional outcomes and were useful to address distal fixation, femoral offset restoration, leg length equalization, and hip stability when revising failed femoral components. Level of Evidence Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence....


    • 1 October 2010
      • Vol. 20, 309-13

    Neck-modular femoral stems for total hip arthroplasty.

    by Nitin Goyal, William J Hozack

    Modular total hip arthroplasty (THA) components have evolved significantly as the success of uncemented femoral fixation has been proven. Current trends in the United States include widespread use of cementless components (acetabular and femoral), usually with monoblock femoral stems with modular heads. Femoral offset has been proven to play a vital role in hip abductor strength, hip range of motion, and hip stability. Also critical to hip stability is the orientation of the acetabular and femoral components. Thus, offset and component positioning are fundamental to success in THA. Modularity of the femoral neck has been proposed to aid in further customizing the THA component fit. Neck-modular stems enable the adjustment of leg length, femoral anteversion, and femoral offset independently of stem size. Modularity of the neck allows the surgeon to precisely match the anatomic characteristics of each patient to yield improved range of motion, stability, abductor strength, and leg length equality. Disadvantages are related to cost and the addition of another interface. Neck-modular femoral stems are not a new concept; however, as tough component manufacturing has advanced, these stems have been reintroduced to the armamentarium of the hip surgeon.


  • Natural History of Squeaking after Total Hip Arthroplasty

    by Camilo Restrepo, Wadih Y. Matar, Javad Parvizi, Richard H. Rothman, William J. Hozack

    In recent years, a number of alternative bearing surfaces, such as ceramic on ceramic, are being used in THA. Squeaking after THA is a recently recognized complication; however, its incidence is unknown. Find the incidence of squeaking; when it ensues; activities associated to squeaking; its natural history, and outcome of revisions for squeaking. A prospective observational study between 2002 and 2007; yield 1486 ceramic-on-ceramic THA performed at our institution. All patients were followed up by office visits or by phone, to obtain information regarding squeaking, pain and function. Minimum followup was 2.5 years (mean, 5.5 years; range, 2.5–7.9 years). Ninety-five of the 1486 hips (6%) developed squeaking after THA, 39 females (44%) and 49 males (56%) with an average age of 49.9 years. Squeaking began on average 19.7 months after surgery but not associated with pain or functional impairment in any patient. Squeaking could be heard during walking (38%), ascending stairs (24%), bending forward (21%), and other activities (18%), was constant in 26% of the patients and intermittent in 74%. The intensity and frequency remained similar over time in 70% of the patients. Squeaking is a real phenomenon that occurred in about 6% of our patients. The etiology for this problem remains elusive and is likely to be multifactorial in nature. Squeaking, when developed, does not seem to be self-limited and persists in the majority. Nine patients underwent revision arthroplasty for squeaking. No fractures or other implant-related issues were observed. Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.


  • Do Tantalum and Titanium Cups Show Similar Results in Revision Hip Arthroplasty?

    by Mehdi S. Jafari, Benjamin Bender, Catelyn Coyle, Javad Parvizi, Peter F. Sharkey, William J. Hozack

    Porous surfaces are intended to enhance osteointegration of cementless implants. Tantalum has been introduced in an effort to enhance osseointegration potential of uncemented components. We therefore compared the clinical outcome of acetabular components with two different porous surfaces. We retrospectively reviewed 283 patients (295 hips) who underwent cementless revision hip arthroplasty with either an HA-coated titanium cup (207 patients, 214 hips) or porous tantalum cup (79 patients, 81 hips). The minimum followup was 24 months in both groups (titanium: average 51.8 months, range, 24–98 months; tantalum: average, 35.4 months, range, 24–63 months). The titanium and tantalum groups had a mechanical failure rate (clinical plus radiographic) of 8% and 6%, respectively. In hips with minor bone deficiency (type 1, 2A, 2B using the classification of Paprosky et al.), 6% of titanium cups and 4% of tantalum cups failed. In hips with major bone deficiency (type 2C, 3), 24% of titanium cups and 12% of tantalum cups developed failure. In the major bone deficiency group, the tantalum cups had fewer numbers of lucent zones around the cup. Eighty-two percent of titanium cups that failed did so at 6 months postoperatively or later, whereas 80% of tantalum cups that failed did so in less than 6 months. Radiographically in the major group, tantalum cups yielded better fixation. Level of Evidence: Level III, retrospective comparative study. See the Guidelines for Authors for a complete description of levels of evidence.


  • Revision of the unstable total knee replacement; outcome predictors

    by Khalid Azzam, Javad Parvizi, Daniel Kaufman, James J. Purtill, Peter F. Sharkey, William J. Hozack

    • 1 December 2008
      • Vol. 74  (6) , 793-800

    Periprosthetic infection: are current treatment strategies adequate?

    by Javad Parvizi, Elie Ghanem, Khalid Azzam, Erika Davis, Fereidoon Jaberi, William Hozack

    Two-staged resection arthroplasty with delayed reimplantation is currently the method of choice for treatment of an infected total hip arthroplasty. There is paucity of data regarding the risk factors for reinfection after reimplantation. The objective of this study was to determine the efficacy of two-stage resection arthroplasty for infected THA and to identify risk factors for reinfection. The outcome of this procedure was evaluated in 54 consecutive patients at our institution from January 1999 to August 2005. The mean follow-up time for patients who were successfully treated was 32 months (range: 24 to 76 months). Infection with methicillin-resistant organisms occurred in 33 patients (61%). Recurrent infection was diagnosed in 14 patients (26%) after the second stage reimplantation procedure at an average of 10.6 months. An elevated ASA, which is an indicator of advanced comorbid health status, and infection with methicillin-resistant organisms were risk factors for treatment failure. An additional 8% of the cohort developed early mechanical failure at a mean of 13.8 months. The increase in the number of resistant organisms and the rise in the number of patients with comorbid conditions have compromised the efficacy of two-stage exchange arthroplasty. Hence novel techniques for the treatment of periprosthetic infection are desperately needed.