Christopher Dechant Harner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christopher Dechant Harner has a total of 277 co-authors. Here are the top co-authors by number of shared publications:
Jeffrey A. Rihn
4 shared publicationsCraig S. Mauro
3 shared publications- Freddie H. Fu
Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
3 shared publications James J. Irrgang
Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
3 shared publicationsKathryne J. Stabile
Department of Orthopaedic Surgery, Wake Forest University, Winston-Salem, USA
3 shared publications- Matthew Joseph Salzler
Department of Orthopaedic Surgery Tufts Medical Center Boston Massachusetts U.S.A.
3 shared publications
Latest Publications
- 30 March 2016
- Published by Springer Nature
- p. 493-502
Meniscus Allograft Transplantation with Bony Fixation
- 30 March 2016
- Published by Springer Nature
- p. 493-502
Meniscus Allograft Transplantation with Bony Fixation
- 1 April 2015
- Vol. 44 (4) , E89-93
Revision anterior cruciate ligament reconstruction with bone-patellar tendon-bone allograft and extra-articular iliotibial band tenodesis.
Revision anterior cruciate ligament (ACL) reconstruction is a technically demanding procedure with outcomes that generally fail to reach those seen with primary ACL reconstruction. With most index procedures using autograft tissue, it is not uncommon for allograft tissue to be required for revision ACL reconstruction. Compared with autografts, allografts take longer to incorporate and lead to more episodes of instability. In this article, we describe ipsilateral iliotibial band tenodesis performed to augment use of bone-patellar tendon-bone allograft in revision ACL reconstruction. This technique adds rotational stability to protect the allograft tissue while it incorporates.
- 1 April 2015
- Vol. 44 (4) , E89-93
Revision anterior cruciate ligament reconstruction with bone-patellar tendon-bone allograft and extra-articular iliotibial band tenodesis.
Revision anterior cruciate ligament (ACL) reconstruction is a technically demanding procedure with outcomes that generally fail to reach those seen with primary ACL reconstruction. With most index procedures using autograft tissue, it is not uncommon for allograft tissue to be required for revision ACL reconstruction. Compared with autografts, allografts take longer to incorporate and lead to more episodes of instability. In this article, we describe ipsilateral iliotibial band tenodesis performed to augment use of bone-patellar tendon-bone allograft in revision ACL reconstruction. This technique adds rotational stability to protect the allograft tissue while it incorporates.
- 10 February 2015
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 43 (5) , 1142-1146
Fluoroscopic Determination of the Tibial Insertion of the Posterior Cruciate Ligament in the Sagittal Plane
Currently, placement of the tibial tunnel for arthroscopic transtibial posterior cruciate ligament (PCL) reconstruction relies on a limited arthroscopic view of the native insertion or the use of intraoperative imaging. No widely accepted method exists for intraoperative determination of PCL tibial tunnel placement, and current descriptions are cumbersome. To identify the center of the PCL’s anatomic tibial insertion site as a percentage of the PCL facet length on a lateral radiograph of the knee so that it may be reliably located in the sagittal plane during surgical reconstruction. Descriptive laboratory study. Twenty fresh-frozen cadaveric knees were dissected and the tibial insertions of the PCL were digitized with an optical tracing system. The digitized PCL footprints were mapped onto 3-dimensional computed tomography–acquired tibial models, and their center points were determined. A K-wire was then inserted into the center of the PCL’s tibial insertion under direct visualization, a direct lateral radiograph was obtained, and the center point was measured. The center locations for both methods were defined as a percentage of PCL facet length from anterior and proximal to posterior and distal, and intraobserver and interobserver reliability was tested with 4 different observers. The average location of the PCL center on the 3-dimensional bone model method was 71.7% ± 5.6% along the PCL facet from anterior/proximal to posterior/distal. In the lateral radiographic method, the center of the PCL was at an average of 69.7% ± 4.9% of the facet length. There was no significant difference between the percentage measurements of the 2 methods (P = .13). Interobserver reliability (κ = 0.57) and intraobserver reliability (κ = 0.71) were moderate to strong. Locating the center of the tibial PCL insertion with fluoroscopy at a point that is 70% of the PCL tibial facet length on a true lateral radiograph is a reliable method for locating the PCL tibial insertion. The method described in this study enables clinicians to identify the tibial location of the PCL insertion, which must be accurately determined during PCL reconstruction.
- 10 February 2015
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 43 (5) , 1142-1146
Fluoroscopic Determination of the Tibial Insertion of the Posterior Cruciate Ligament in the Sagittal Plane
Currently, placement of the tibial tunnel for arthroscopic transtibial posterior cruciate ligament (PCL) reconstruction relies on a limited arthroscopic view of the native insertion or the use of intraoperative imaging. No widely accepted method exists for intraoperative determination of PCL tibial tunnel placement, and current descriptions are cumbersome. To identify the center of the PCL’s anatomic tibial insertion site as a percentage of the PCL facet length on a lateral radiograph of the knee so that it may be reliably located in the sagittal plane during surgical reconstruction. Descriptive laboratory study. Twenty fresh-frozen cadaveric knees were dissected and the tibial insertions of the PCL were digitized with an optical tracing system. The digitized PCL footprints were mapped onto 3-dimensional computed tomography–acquired tibial models, and their center points were determined. A K-wire was then inserted into the center of the PCL’s tibial insertion under direct visualization, a direct lateral radiograph was obtained, and the center point was measured. The center locations for both methods were defined as a percentage of PCL facet length from anterior and proximal to posterior and distal, and intraobserver and interobserver reliability was tested with 4 different observers. The average location of the PCL center on the 3-dimensional bone model method was 71.7% ± 5.6% along the PCL facet from anterior/proximal to posterior/distal. In the lateral radiographic method, the center of the PCL was at an average of 69.7% ± 4.9% of the facet length. There was no significant difference between the percentage measurements of the 2 methods (P = .13). Interobserver reliability (κ = 0.57) and intraobserver reliability (κ = 0.71) were moderate to strong. Locating the center of the tibial PCL insertion with fluoroscopy at a point that is 70% of the PCL tibial facet length on a true lateral radiograph is a reliable method for locating the PCL tibial insertion. The method described in this study enables clinicians to identify the tibial location of the PCL insertion, which must be accurately determined during PCL reconstruction.
- 14 October 2014
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 42 (12) , 2972-2978
Effects of Knee Flexion Angle and Loading Conditions on the End-to-End Distance of the Posterior Cruciate Ligament
It is commonly accepted that the anterolateral (AL) bundle of the posterior cruciate ligament (PCL) is tight in flexion and that the posteromedial (PM) bundle is tight in extension. However, a recent in vivo study showed that both bundles were tight in extension. To investigate the effects of knee flexion angle, rotational torque, and anterior/posterior translational force on the end-to-end distance between the femoral and tibial insertion sites of each bundle of the PCL. Descriptive laboratory study. Cadaveric knees (10 specimens) were mounted on a robotic system, and the relative positional data between the femur and tibia were acquired during passive flexion/extension, with an applied 5-N·m rotational torque and an applied 89-N translational force. The bony surface and PCL insertion data were acquired with a 3-dimensional scanner after gross dissection and were superimposed onto the positional data. The end-to-end distance between the 2 PCL insertion sites of the femur and tibia was measured. The end-to-end distance increased from full extension to 90° for both the AL (9.2 ± 1.8 mm; from 30.0 to 39.2 mm) and PM bundles (5.8 ± 2.2 mm; from 32.0 to 37.7 mm). With an internal rotational torque, the end-to-end distance of the PM bundle increased significantly (P < .05) at 0°, 30°, and 60° of knee flexion. Under a posterior translational force at 90° of knee flexion, the length of both bundles increased to their longest measurements (AM bundle: 40.6 ± 4.2 mm; PM bundle: 38.4 ± 3.8 mm). The end-to-end distance of the AL and PM bundles of the PCL increased in flexion, and this pattern was maintained during tests with posterior translational force. The PM bundle was more affected by the rotational torque than was the AL bundle. Both bundles of the PCL may serve a greater functional role in flexion than in extension. The PM bundle might be more important for the control of rotation than the AL bundle. Posterior translation at 90° of knee flexion could be the most stressful condition for both bundles of the PCL, which may have implications for an injury mechanism.
- 14 October 2014
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 42 (12) , 2972-2978
Effects of Knee Flexion Angle and Loading Conditions on the End-to-End Distance of the Posterior Cruciate Ligament
It is commonly accepted that the anterolateral (AL) bundle of the posterior cruciate ligament (PCL) is tight in flexion and that the posteromedial (PM) bundle is tight in extension. However, a recent in vivo study showed that both bundles were tight in extension. To investigate the effects of knee flexion angle, rotational torque, and anterior/posterior translational force on the end-to-end distance between the femoral and tibial insertion sites of each bundle of the PCL. Descriptive laboratory study. Cadaveric knees (10 specimens) were mounted on a robotic system, and the relative positional data between the femur and tibia were acquired during passive flexion/extension, with an applied 5-N·m rotational torque and an applied 89-N translational force. The bony surface and PCL insertion data were acquired with a 3-dimensional scanner after gross dissection and were superimposed onto the positional data. The end-to-end distance between the 2 PCL insertion sites of the femur and tibia was measured. The end-to-end distance increased from full extension to 90° for both the AL (9.2 ± 1.8 mm; from 30.0 to 39.2 mm) and PM bundles (5.8 ± 2.2 mm; from 32.0 to 37.7 mm). With an internal rotational torque, the end-to-end distance of the PM bundle increased significantly (P < .05) at 0°, 30°, and 60° of knee flexion. Under a posterior translational force at 90° of knee flexion, the length of both bundles increased to their longest measurements (AM bundle: 40.6 ± 4.2 mm; PM bundle: 38.4 ± 3.8 mm). The end-to-end distance of the AL and PM bundles of the PCL increased in flexion, and this pattern was maintained during tests with posterior translational force. The PM bundle was more affected by the rotational torque than was the AL bundle. Both bundles of the PCL may serve a greater functional role in flexion than in extension. The PM bundle might be more important for the control of rotation than the AL bundle. Posterior translation at 90° of knee flexion could be the most stressful condition for both bundles of the PCL, which may have implications for an injury mechanism.
- 18 September 2014
- Published by Springer Nature
- p. 149-159
Stress Fractures of the Fifth Metatarsal
- Open Access
- 1 August 2014
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 2 (8)
Vertical Tears of the Lateral Meniscus
Lateral meniscal tears are often seen with acute anterior cruciate ligament (ACL) injury and may be left in situ, repaired, or treated with meniscectomy. Clinical studies have shown good outcomes with vertical tears left in situ and poor outcomes following meniscectomy. However, clinically relevant studies are needed to establish a biomechanical foundation for treatment of these tears, particularly regarding the effects of meniscectomy. To compare tibiofemoral joint mechanics following vertical lateral meniscal tears and meniscectomies. We hypothesized that a peripheral vertical tear of the lateral meniscus would alter joint mechanics, increasing contact pressure and area, and that more drastic effects would be seen following meniscectomy, at higher knee flexion angles, and with increased loads. Controlled laboratory study. Ten fresh-frozen cadaveric knees (average age, 55 ± 12 years) were tested with 5 lateral meniscus states: intact, short vertical tear, extended vertical tear, posterior horn partial meniscectomy (rim intact), and posterior horn subtotal meniscectomy (rim excised). The specimens were loaded axially at knee flexion angles of 0°, 30°, and 60°, and musculotendinous forces were applied, simulating a 2-legged squat. Intra-articular contact pressures were measured using pressure-sensitive Fuji film. Kinematic data were acquired through digitization of fiducial markers. Vertical tears did not cause a significant change in contact pressure or area. Partial meniscectomy increased maximum contact pressures in the lateral compartment at 30° and 60° from 5.3 MPa to 7.2 MPa and 7.6 MPa, respectively (P = .02, P = .007). Subtotal meniscectomy (8.4 MPa) significantly increased contact pressure compared with partial meniscectomy (7.6 MPa) at 60° (P = .04). Both meniscectomy states significantly increased contact pressures with increasing flexion from 0° to 60° (P < .001, P < .001). Vertical tears of the lateral meniscus during a simulated 2-legged squat did not significantly change contact pressures and areas compared with an intact meniscus. However, treating these tears with partial and complete meniscectomy significantly increased maximum contact pressures. Biomechanical evidence supports treating vertical lateral meniscus tears with meniscal-sparing techniques as opposed to meniscectomy, which may lead to progressive degenerative joint disease from altered joint biomechanics.
- 1 August 2014
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 2 (8)
Open AccessVertical Tears of the Lateral Meniscus
Lateral meniscal tears are often seen with acute anterior cruciate ligament (ACL) injury and may be left in situ, repaired, or treated with meniscectomy. Clinical studies have shown good outcomes with vertical tears left in situ and poor outcomes following meniscectomy. However, clinically relevant studies are needed to establish a biomechanical foundation for treatment of these tears, particularly regarding the effects of meniscectomy. To compare tibiofemoral joint mechanics following vertical lateral meniscal tears and meniscectomies. We hypothesized that a peripheral vertical tear of the lateral meniscus would alter joint mechanics, increasing contact pressure and area, and that more drastic effects would be seen following meniscectomy, at higher knee flexion angles, and with increased loads. Controlled laboratory study. Ten fresh-frozen cadaveric knees (average age, 55 ± 12 years) were tested with 5 lateral meniscus states: intact, short vertical tear, extended vertical tear, posterior horn partial meniscectomy (rim intact), and posterior horn subtotal meniscectomy (rim excised). The specimens were loaded axially at knee flexion angles of 0°, 30°, and 60°, and musculotendinous forces were applied, simulating a 2-legged squat. Intra-articular contact pressures were measured using pressure-sensitive Fuji film. Kinematic data were acquired through digitization of fiducial markers. Vertical tears did not cause a significant change in contact pressure or area. Partial meniscectomy increased maximum contact pressures in the lateral compartment at 30° and 60° from 5.3 MPa to 7.2 MPa and 7.6 MPa, respectively (P = .02, P = .007). Subtotal meniscectomy (8.4 MPa) significantly increased contact pressure compared with partial meniscectomy (7.6 MPa) at 60° (P = .04). Both meniscectomy states significantly increased contact pressures with increasing flexion from 0° to 60° (P < .001, P < .001). Vertical tears of the lateral meniscus during a simulated 2-legged squat did not significantly change contact pressures and areas compared with an intact meniscus. However, treating these tears with partial and complete meniscectomy significantly increased maximum contact pressures. Biomechanical evidence supports treating vertical lateral meniscus tears with meniscal-sparing techniques as opposed to meniscectomy, which may lead to progressive degenerative joint disease from altered joint biomechanics.
- 15 April 2014
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 2 (4)
Tunnel Placement for the ACL During Reconstructive Surgery of the Knee
Anterior cruciate ligament (ACL) surgery continues to evolve as we gain a better understanding of the anatomy and biomechanics of the ACL. In the late 1980s, there was a shift from a two-incision (rear-entry guide) to a single-incision (transtibial) technique. The impetus driving this was the potential to achieve equivalent tunnel placement more quickly and in a more cosmetic fashion1. However, when anatomic studies clearly defined the ACL femoral insertion site on the lateral intercondylar wall and not the roof, it was discovered that even when performed as described in the Surgical Techniques supplement of The Journal of Bone & Joint Surgery in 20052, the traditional transtibial technique placed the femoral tunnel higher (toward the apex of the notch as opposed to the wall) on the intercondylar notch, outside the native insertion site (Fig. 1)3-6. Some surgeons postulated that, even with adjustments to the traditional transtibial technique, transtibial drilling would always place the femoral tunnel higher on the intercondylar notch than the location of the native insertion site (Fig. 2, A ). In order to avoid placing the femoral tunnel on the intercondylar roof as is commonly associated with the transtibial technique (also known as the …
- 15 April 2014
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 2 (4)
Tunnel Placement for the ACL During Reconstructive Surgery of the Knee
Anterior cruciate ligament (ACL) surgery continues to evolve as we gain a better understanding of the anatomy and biomechanics of the ACL. In the late 1980s, there was a shift from a two-incision (rear-entry guide) to a single-incision (transtibial) technique. The impetus driving this was the potential to achieve equivalent tunnel placement more quickly and in a more cosmetic fashion1. However, when anatomic studies clearly defined the ACL femoral insertion site on the lateral intercondylar wall and not the roof, it was discovered that even when performed as described in the Surgical Techniques supplement of The Journal of Bone & Joint Surgery in 20052, the traditional transtibial technique placed the femoral tunnel higher (toward the apex of the notch as opposed to the wall) on the intercondylar notch, outside the native insertion site (Fig. 1)3-6. Some surgeons postulated that, even with adjustments to the traditional transtibial technique, transtibial drilling would always place the femoral tunnel higher on the intercondylar notch than the location of the native insertion site (Fig. 2, A ). In order to avoid placing the femoral tunnel on the intercondylar roof as is commonly associated with the transtibial technique (also known as the …
- 27 November 2013
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 41 (12) , 2742-2745
Presidential Address of the American Orthopaedic Society for Sports Medicine
- 27 November 2013
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 41 (12) , 2742-2745
Presidential Address of the American Orthopaedic Society for Sports Medicine
- 27 November 2013
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 42 (2) , 292-296
Complications After Arthroscopic Knee Surgery
Knee arthroscopies are among the most common procedures performed by orthopaedic surgeons, yet little is known about the associated complications and complication rates. To examine the nature and frequency of complications after the most common arthroscopic knee procedures, with particular attention to fellowship training, geographic location of practice, and age and sex of the patient. Cross-sectional study; Level of evidence, 3. Data were obtained from the American Board of Orthopaedic Surgery database for orthopaedic surgeons who sat for the part II examination from 2003 to 2009. The database was queried to determine the type and frequency of complications for patients who underwent knee arthroscopy and for those who underwent sports medicine knee arthroscopy, including arthroscopic partial meniscectomy, meniscal repair, chondroplasty, microfracture, anterior cruciate ligament reconstruction, or posterior cruciate ligament reconstruction. Factors affecting complication rates that were investigated included type of procedure, fellowship training status, geographic location of practice, and age and sex of the patient. There were 4305 complications out of 92,565 knee arthroscopic procedures obtained from the American Board of Orthopaedic Surgery database for an overall candidate-reported complication rate of 4.7%. The complication rates were highest for posterior cruciate ligament reconstruction (20.1%) and anterior cruciate ligament reconstruction (9.0%); complication rates for meniscectomy, meniscal repair, and chondroplasty were 2.8%, 7.6%, and 3.6%, respectively. The complication rate for sports fellowship–trained candidates was higher than for non–sports trained candidates (5.1% sports, 4.1% no sports; P < .0001) and for male patients (4.9% male vs 4.3% female; P < .0001). Younger patients (P < .0001). Procedure complexity is a likely confounding factor affecting sports-trained candidates and younger patients. There were no geographic differences (P = .125). The overall rate of pulmonary embolus was 0.11%. Surgical complications (3.68%) were more common than medical (0.77%) or anesthetic complications (0.22%), and infection was the most common complication overall (0.84%). The overall self-reported complication rate for arthroscopic knee procedures was 4.7%. Knee arthroscopy is not a benign procedure, and patients should be aware of the risk of complications.
- 27 November 2013
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 42 (2) , 292-296
Complications After Arthroscopic Knee Surgery
Knee arthroscopies are among the most common procedures performed by orthopaedic surgeons, yet little is known about the associated complications and complication rates. To examine the nature and frequency of complications after the most common arthroscopic knee procedures, with particular attention to fellowship training, geographic location of practice, and age and sex of the patient. Cross-sectional study; Level of evidence, 3. Data were obtained from the American Board of Orthopaedic Surgery database for orthopaedic surgeons who sat for the part II examination from 2003 to 2009. The database was queried to determine the type and frequency of complications for patients who underwent knee arthroscopy and for those who underwent sports medicine knee arthroscopy, including arthroscopic partial meniscectomy, meniscal repair, chondroplasty, microfracture, anterior cruciate ligament reconstruction, or posterior cruciate ligament reconstruction. Factors affecting complication rates that were investigated included type of procedure, fellowship training status, geographic location of practice, and age and sex of the patient. There were 4305 complications out of 92,565 knee arthroscopic procedures obtained from the American Board of Orthopaedic Surgery database for an overall candidate-reported complication rate of 4.7%. The complication rates were highest for posterior cruciate ligament reconstruction (20.1%) and anterior cruciate ligament reconstruction (9.0%); complication rates for meniscectomy, meniscal repair, and chondroplasty were 2.8%, 7.6%, and 3.6%, respectively. The complication rate for sports fellowship–trained candidates was higher than for non–sports trained candidates (5.1% sports, 4.1% no sports; P < .0001) and for male patients (4.9% male vs 4.3% female; P < .0001). Younger patients (P < .0001). Procedure complexity is a likely confounding factor affecting sports-trained candidates and younger patients. There were no geographic differences (P = .125). The overall rate of pulmonary embolus was 0.11%. Surgical complications (3.68%) were more common than medical (0.77%) or anesthetic complications (0.22%), and infection was the most common complication overall (0.84%). The overall self-reported complication rate for arthroscopic knee procedures was 4.7%. Knee arthroscopy is not a benign procedure, and patients should be aware of the risk of complications.