Laura Chiappini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Laura Chiappini has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
B. Brouard
INERIS (Institut National de l’Environnement Industriel et des Risques), Parc technologique Alata, Verneuil‐en‐Halatte, France
1 shared publicationC. Rio
Institut National de l'Environnement Industriel et des Risques, Parc Technologique ALATA, 60550 Verneuil-en-Halatte, France
1 shared publication- Christian George
Université Lyon 1 CNRS IRCELYON UMR 5256 Villeurbanne France
1 shared publication E. Perraudin
LISA, Universités Paris-Est-Créteil et Paris Diderot, CNRS UMR7583, 61 Av. du Général de Gaulle, 94010 Créteil, France
1 shared publication- Eva Leoz-Garziandia
Institut National De L’environnement Industriel et Des Risques (INERIS), Parc Technologique Alata BP2, 60550 Verneuil-en-Halatte, France
1 shared publication Faustina Fuvel
Direction des Risques Chroniques (DRC), Unité Chimie Métrologie Essais (CIME), Institut National de l’Environment Industriel et des Risques, Verneuil-en-Halatte, France
1 shared publication
Latest Publications
- Open Access
- 27 June 2012
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 5 (6) , 1459-1489
Development of a parallel sampling and analysis method for the elucidation of gas/particle partitioning of oxygenated semi-volatile organics: a limonene ozonolysis study
The gas/particle partitioning behaviour of the semi-volatile fraction of secondary organic matter and the associated multiphase chemistry are key features to accurately evaluate climate and health impacts of secondary organic aerosol (SOA). However, today, the partitioning of oxygenated secondary species is rarely assessed in experimental SOA studies and SOA modelling is still largely based on estimated partitioning data. This paper describes a new analytical approach, solvent-free and easy to use, to explore the chemical composition of the secondary organic matter at a molecular scale in both gas and particulate phases. The method is based on thermal desorption (TD) of gas and particulate samples, coupled with gas chromatography (GC) and mass spectrometry (MS), with derivatisation on sampling supports. Gaseous compounds were trapped on Tenax TA adsorbent tubes pre-coated with pentafluorobenzylhydroxylamine (PFBHA) or N-Methyl-N-(t-butyldimethylsilyl)trifluoroacetamide (MTBSTFA). Particulate samples were collected onto quartz or Teflon-quartz filters and subsequently subjected to derivatisation with PFBHA or MTBSTFA before TD-GC/MS analysis. Method development and validation are presented for an atmospherically relevant range of organic acids and carbonyl and hydroxyl compounds. Application of the method to a limonene ozonolysis experiment conducted in the EUPHORE simulation chamber under simulated atmospheric conditions of low concentrations of limonene precursor and relative humidity, provides an overview of the method capabilities. Twenty-five compounds were positively or tentatively identified, nine being in both gaseous and particulate phases; and twelve, among them tricarboxylic acids, hydroxyl dicarboxylic acids and oxodicarboxylic acids, being detected for the first time.
- 27 June 2012
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 5 (6) , 1459-1489
Open AccessDevelopment of a parallel sampling and analysis method for the elucidation of gas/particle partitioning of oxygenated semi-volatile organics: a limonene ozonolysis study
The gas/particle partitioning behaviour of the semi-volatile fraction of secondary organic matter and the associated multiphase chemistry are key features to accurately evaluate climate and health impacts of secondary organic aerosol (SOA). However, today, the partitioning of oxygenated secondary species is rarely assessed in experimental SOA studies and SOA modelling is still largely based on estimated partitioning data. This paper describes a new analytical approach, solvent-free and easy to use, to explore the chemical composition of the secondary organic matter at a molecular scale in both gas and particulate phases. The method is based on thermal desorption (TD) of gas and particulate samples, coupled with gas chromatography (GC) and mass spectrometry (MS), with derivatisation on sampling supports. Gaseous compounds were trapped on Tenax TA adsorbent tubes pre-coated with pentafluorobenzylhydroxylamine (PFBHA) or N-Methyl-N-(t-butyldimethylsilyl)trifluoroacetamide (MTBSTFA). Particulate samples were collected onto quartz or Teflon-quartz filters and subsequently subjected to derivatisation with PFBHA or MTBSTFA before TD-GC/MS analysis. Method development and validation are presented for an atmospherically relevant range of organic acids and carbonyl and hydroxyl compounds. Application of the method to a limonene ozonolysis experiment conducted in the EUPHORE simulation chamber under simulated atmospheric conditions of low concentrations of limonene precursor and relative humidity, provides an overview of the method capabilities. Twenty-five compounds were positively or tentatively identified, nine being in both gaseous and particulate phases; and twelve, among them tricarboxylic acids, hydroxyl dicarboxylic acids and oxodicarboxylic acids, being detected for the first time.
- Open Access
- 21 October 2010
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 4 (3-4) , 211-220
Multi-tool formaldehyde measurement in simulated and real atmospheres for indoor air survey and concentration change monitoring
Formaldehyde is of particular health concern since it is carcinogenic for human and ubiquitous in indoor air where people spend most of their time. Therefore, it is important to have suitable methods and techniques to measure its content in indoor air. In the present work, four different techniques have been tested in the INERIS exposure chamber and in indoor environments in comparison to a standard active method: passive sampling method based on the reaction of 2,4-dinitrophenylhydrazine with formaldehyde, two on-line continuous monitoring systems based on fluorescence and UV measurements and a portable commercialised analyser based on electrochemical titration. Two formaldehyde concentrations, about 10 and 25 μg m−3 were generated in an exposure chamber under controlled conditions of temperature, relative humidity, and wind speed to simulate real conditions and assess potential influence on passive sampling and continuous systems response. Influence of sampling periods on passive sampling has also been evaluated. The real atmosphere experiments have been performed in four different indoor environments: an office, a furniture shop, a shopping mall, and residential dwellings in which several potential formaldehyde sources linked to household activities have been tested. The analytical and sampling problems associated with each measurement method have been identified and discussed. An overall agreement between each technique has been observed and continuous analyzers allowed for formaldehyde concentrations change monitoring and secondary formation of that pollutant observation.
- 21 October 2010
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 4 (3-4) , 211-220
Open AccessMulti-tool formaldehyde measurement in simulated and real atmospheres for indoor air survey and concentration change monitoring
Formaldehyde is of particular health concern since it is carcinogenic for human and ubiquitous in indoor air where people spend most of their time. Therefore, it is important to have suitable methods and techniques to measure its content in indoor air. In the present work, four different techniques have been tested in the INERIS exposure chamber and in indoor environments in comparison to a standard active method: passive sampling method based on the reaction of 2,4-dinitrophenylhydrazine with formaldehyde, two on-line continuous monitoring systems based on fluorescence and UV measurements and a portable commercialised analyser based on electrochemical titration. Two formaldehyde concentrations, about 10 and 25 μg m−3 were generated in an exposure chamber under controlled conditions of temperature, relative humidity, and wind speed to simulate real conditions and assess potential influence on passive sampling and continuous systems response. Influence of sampling periods on passive sampling has also been evaluated. The real atmosphere experiments have been performed in four different indoor environments: an office, a furniture shop, a shopping mall, and residential dwellings in which several potential formaldehyde sources linked to household activities have been tested. The analytical and sampling problems associated with each measurement method have been identified and discussed. An overall agreement between each technique has been observed and continuous analyzers allowed for formaldehyde concentrations change monitoring and secondary formation of that pollutant observation.
- 1 June 2009
- Published by Hindawi Limited in Indoor Air
- Vol. 19 (3) , 226-233
A first French assessment of population exposure to tetrachloroethylene from small dry-cleaning facilities
Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies.In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.
- 1 June 2009
- Published by Hindawi Limited in Indoor Air
- Vol. 19 (3) , 226-233
A first French assessment of population exposure to tetrachloroethylene from small dry-cleaning facilities
Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies.In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.