JWJohn Tracy Watson

John Tracy Watson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Tracy Watson has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In reply to the letter to the editor regarding “Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures”

    by Leo Nherera, Paul Trueman, Alan Horner, Tracy Watson, Alan J. Johnstone

    Background: Intertrochanteric hip fractures are common and devastating injuries, especially for the elderly. Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows early rehabilitation and functional recovery. The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain limited to relatively small studies which create uncertainty in attempts to establish evidence-based best practice. Methods: We conducted a systematic review and meta-analysis of randomised controlled trials (RCTs) and observational studies to assess the clinical effectiveness of two commonly used intramedullary devices: a twin-screw integrated cephalomedullary nail (InterTAN) versus a single-screw cephalomedullary nail (proximal femoral nail antirotation) in patients with intertrochanteric fractures. The following outcomes were considered: revisions, implant-related failures, non-unions, pain, Harris hip score and intra-operative outcomes. Odds ratios or mean differences with 95% confidence intervals in brackets are reported. Results: Six studies met the inclusion criteria: two randomised controlled trials and four observational studies enrolling 970 patients with a mean age of 77 years and 64% of patients being female. There was a statistically significant difference (p value < 0.05) for revisions OR 0.27 (0.13–0.56), implant-related failures OR 0.16 (0.09–0.27) and proportion of patients complaining of pain OR 0.50 (0.34–0.74). There was no difference in non-unions and Harris hip score (p value > 0.05). There was a significant difference in blood loss and fluoroscopy usage in favour of PFNA, while no difference in operating times was observed between the two devices. Conclusions: Our meta-analysis suggests that a twin-screw integrated cephalomedullary nail (InterTAN) is clinically more effective when compared to a single-screw cephalomedullary nail proximal femoral nail antirotation resulting in fewer complications, fewer revisions and fewer patients complaining of pain. No difference has been established regarding non-unions and Harris hip score. Intra-operative outcomes favour PFNA with less blood loss and fluoroscopy usage. Further studies are warranted to explore the cost-effectiveness of these and other implants in managing patients with intertrochanteric fractures.


  • Open Access

    Comparing the costs and outcomes of an integrated twin compression screw (ITCS) nail with standard of care using a single lag screw or a single helical blade cephalomedullary nail in patients with intertrochanteric hip fractures

    by Leo M. Nherera, Paul Trueman, Alan Horner, Alan J. Johnstone, Tracy J. Watson, Francis A. Fatoye

    Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows for early rehabilitation and functional recovery. The purpose of the study was to assess the cost-effectiveness of commonly used cephalomedullary nails for the treatment of unstable intertrochanteric hip fractures. A decision analytic model was developed from a US payer’s perspective using clinical data from a pairwise meta-analysis of randomised controlled trials (RCTs) and comparative observational studies comparing the integrated twin compression screw (ITCS) nail versus two single-screw or blade cephalomedullary nails [single lag screw (SLS) nail and single helical blade (SHB) nail]. The model considered a cohort of 1000 patients with a mean age of 76, as reported in the clinical studies over a 1-year time period. Cost data was obtained from the Center for Medicare and Medicaid Services website and published literature and adjusted for inflation. One-way and probabilistic sensitivity analyses were conducted to assess the effect of uncertainty in model parameters on model conclusions. The model estimated 0.546 quality-adjusted life years (QALYs) and 0.78 complications avoided by using the ITCS nail and 0.455 QALYs and 0.67 complications avoided for the standard of care, using SLS or SHB nails. The cost per patient was $34,336 for patients treated with an ITCS nail and $37,036 for patients treated with the standard of care respectively, resulting in a cost saving of $2700 in favour of the ITCS nail. More savings were observed when the ITCS nail was compared to the SHB ($3280 per patient) and SLS ($1652 per patient). The findings were robust to a range of both one-way and the probabilistic sensitivity analyses. In conclusion, the ITCS nail can be considered a cost saving intervention in patients undergoing intertrochanteric fracture fixation with an intramedullary device. Clinicians and policy makers should be encouraged to adopt healthcare technologies such as ITCS that will help them to provide quality healthcare despite falling budgets.


  • Open Access

    Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures

    by Leo Nherera, Paul Trueman, Alan Horner, Tracy Watson, Alan J. Johnstone

    Intertrochanteric hip fractures are common and devastating injuries especially for the elderly. Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows early rehabilitation and functional recovery. The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain limited to relatively small studies which create uncertainty in attempts to establish evidence-based best practice. We conducted a systematic review and meta-analysis of randomised controlled trials (RCTs) and observational studies to assess the clinical effectiveness of two commonly used intramedullary devices: a twin screw integrated cephalomedullary nail (InterTAN) versus a single screw cephalomedullary nail (proximal femoral nail antirotation) in patients with intertrochanteric fractures. The following outcomes were considered: revisions, implant-related failures, non-unions, pain, Harris Hip Score and intraoperative outcomes. Odds ratios or mean differences with 95% confidence intervals in brackets are reported. Six studies met the inclusion criteria, two randomised controlled trials and four observational studies enrolling 970 patients with mean age of 77 years, and 64% of patients were female. There was a statistically significant difference (p value < 0.05) for revisions OR 0.27 (0.13 to 0.56), implant-related failures OR 0.16 (0.09 to 0.27) and proportion of patients complaining of pain OR 0.50 (0.34 to 0.74). There was no difference in non-unions and Harris Hip Score (p value > 0.05). There was a significant difference in blood loss and fluoroscopy usage in favour of PFNA, whilst no difference in operating times were observed between the two devices. Our meta-analysis suggests that a twin screw integrated cephalomedullary nail InterTAN is clinically more effective when compared to a single screw cephalomedullary nail proximal femoral nail antirotation resulting in fewer complications, fewer revisions and fewer patients complaining of pain. No difference has been established regarding non-unions and Harris Hip Score. Intraoperative outcomes favour PFNA with less blood loss and fluoroscopy usage. Further studies are warranted to explore the cost-effectiveness of these and other implants in managing patients with intertrochanteric fractures.


  • Lower extremity nontensioned traction pins: is it a benign procedure?

    by Irshad Shakir, Rajan Bs Ganash, J. Tracy Watson

    Background: To evaluate our institution’s infection rate with lower extremity traction pins and ascertain any risk factors. Additionally we sought to evaluate if the location of pin placement provided a higher risk of infection. Methods: This was a retrospective case-control study at a level 1 urban university trauma center. Five hundred and fifty six patients had 575 traction pins placed from February 2009 through December 2014. The intervention was bedside application of a centrally threaded 6-mm traction pin in the femur, tibia, or calcaneus. Radiographs were reviewed and zones were denoted. The diaphysis was bisected to determine anterior and posterior margins. The quadrant locations were as follows (1- proximal anterior, 2- proximal posterior, 3- distal anterior, and 4- distal posterior). Results: The total pins placed were 575 pins: 320 tibial, 236 femoral, and 19 calcaneal. There was an average of 9.6 mo of follow-up. There were five pin track infections (0.87%), all of which were treated successfully with oral antibiotics. There were two peroneal nerve injuries both which resolved by last follow-up. There was no septic arthritis of the knee. No correlations were noted between diabetes, body mass index, smoking, hypertension, and pin track infections or peroneal nerve injuries. There were 283 pins placed into zone 1, 166 in zone 2, 87 in zone 3, and 20 in zone 4. The 19 calcaneal pins were not categorized into quadrant systems. No correlation was noted between the bone in which the traction pin was placed and pin track infection or peroneal nerve injuries. Of the five pin track infections, all were placed in an eccentric posterior location. Four were in zone 2 and one in zone 4, which was statistically significant (P<0.05). No correlation was found between location of pins and peroneal nerve injury. The average time of pin placement to definitive surgery and pin removal was 2.83 days (0-28 days). There was no correlations between rates of infection and the amount of time in traction. Conclusions: This study revealed a low infection rate with 6-mm centrally threaded traction pins in our population. These larger, temporary lower extremity traction pins can be safely placed at the bedside and require no additional equipment for their use. Proximal and posteriorly placed pins in the tibia and femur have a correlation to pin track infections and thus should be avoided. These posteriorly placed pins tether more musculotendinous structures and, thus, are at risk for producing more immediate tissue necrosis with insertion and or use. Nontensioned anterior pins can be used with minimal risk of complication and are recommended. Level of Evidence: Prognostic level IV.


  • Letter to the Editor in response to Drs. Safiri and Ayubi

    by Robert Zura, Mary Jo Braid-Forbes, Kyle Jeray, Samir Mehta, Thomas A. Einhorn, J. Tracy Watson, Gregory J. Della Rocca, Kevin Forbes, R. Grant Steen

  • Open Access

    Healing of fracture nonunions treated with low-intensity pulsed ultrasound (LIPUS): A systematic review and meta-analysis

    by Ross Leighton, J. Tracy Watson, Peter Giannoudis, Costas Papakostidis, Andrew Harrison, R. Grant Steen


  • Open Access

    Controlled Compression Nailing for At Risk Humeral Shaft Fractures

    by J. Tracy Watson, Roy W. Sanders

    Summary: Compression techniques seem to be the primary factor in determining the success of both plating and nailing techniques for the management of acute fractures and for delayed and nonunion management of these fractures. An intramedullary nail that can provide continual compression (like a plate) and mechanical manipulation of the callous throughout the course of treatment is an ideal device that provides all the advantages of plating and nailing and avoids the noted limitations of both. The UNYTE compression humeral nail is based on the PRECICE intramedullary limb lengthening system. This nail provides the ability to intraoperatively compress a humeral fracture immediately and continue compression in the outpatient setting with the external remote controller. This compression nail allows the surgeon to continually modulate stability through controlled compression and the ability to relengthen if necessary. The capacity to achieve constant compression at the fracture site has demonstrated rapid healing of the “at risk” humerus fracture in this series. We review the current indications for use of this device after its early introduction. In most cases, this was the failure of conservative brace management that presented with a progressive distraction gap and minimal callous formation or those fractures that could not be adequately controlled in the brace with malalignment greater than 20 degrees. The protocol for intraoperative compression using the external remote controller is detailed, as is the outpatient protocol for follow-up. The compression algorithm for progression to full fracture healing is also reviewed.


  • Open Access

    An inception cohort analysis to predict nonunion in tibia and 17 other fracture locations

    by Robert Zura, J. Tracy Watson, Thomas Einhorn, Samir Mehta, Gregory J. Della Rocca, Ze Xiong, Zhe Wang, John Jones, R. Grant Steen


  • Open Access

    Bone fracture nonunion rate decreases with increasing age: A prospective inception cohort study

    by Robert Zura, Mary Jo Braid-Forbes, Kyle Jeray, Samir Mehta, Thomas A. Einhorn, J. Tracy Watson, Gregory J. Della Rocca, Kevin Forbes, R. Grant Steen