Masayoshi Yokoyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masayoshi Yokoyama has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Keiichi Sasaki
Division of Advanced Prosthetic Dentistry Tohoku University Graduate School of Dentistry Sendai Japan
3 shared publications- Shigeto Koyama
Maxillofacial Prosthetics Clinic, Tohoku University Hospital, Sendai, Japan
2 shared publications Genki Adachi
1 shared publication- Hanako Suenaga
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate school of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan
1 shared publication Hiroto Sasaki
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
1 shared publication- Keiichi Sasaki
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
1 shared publication
Latest Publications
- 27 June 2013
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (9) , 1084-1090
Influence of immediate and early loading on bone metabolic activity around dental implants in rat tibiae
Objectives The aim of this study was to examine the influence of immediate and early loading on dynamic changes in bone metabolism around dental implants using bone scintigraphy. Material and methods Two titanium implants were inserted in the right tibiae of 21 rats. Closed coil springs with 4.0-N loads were applied parallel to the upper portion of the implants for 35 days. According to the load application timing, rats were divided into three groups: immediate loading (IL) group, early loading 1 day after implant insertion (1-D early loading [EL]) group, and loading 3 days after implant insertion (3-D EL) group. Rats were intravenously injected with technetium-99 m-methylene diphosphonate (Tc99 m-MDP) (74 MBq/rat) and scanned by bone scintigraphy at 1, 4, 7, 11, 14, 21, 28, and 35 days after load application. The ratio of accumulation of Tc99 m-MDP around the implants to that of a reference site (uptake ratio) was calculated to evaluate bone metabolism. Results In every group, the uptake ratio increased until 7 days after load application and then gradually decreased. It was significantly higher than baseline at 4, 7, 11, and 14 days (P < 0.001). The uptake ratio in the 1-D EL and 3-D EL groups were significantly higher than that in the control group and also that in the IL group (P < 0.001). Conclusions Bone metabolism initially increased and then gradually decreased to baseline despite differences in load timing. Increases in bone metabolic activity differed according to load application timing; the later the load application, the more enhanced the bone metabolism.
- 27 June 2013
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (9) , 1084-1090
Influence of immediate and early loading on bone metabolic activity around dental implants in rat tibiae
Objectives The aim of this study was to examine the influence of immediate and early loading on dynamic changes in bone metabolism around dental implants using bone scintigraphy. Material and methods Two titanium implants were inserted in the right tibiae of 21 rats. Closed coil springs with 4.0-N loads were applied parallel to the upper portion of the implants for 35 days. According to the load application timing, rats were divided into three groups: immediate loading (IL) group, early loading 1 day after implant insertion (1-D early loading [EL]) group, and loading 3 days after implant insertion (3-D EL) group. Rats were intravenously injected with technetium-99 m-methylene diphosphonate (Tc99 m-MDP) (74 MBq/rat) and scanned by bone scintigraphy at 1, 4, 7, 11, 14, 21, 28, and 35 days after load application. The ratio of accumulation of Tc99 m-MDP around the implants to that of a reference site (uptake ratio) was calculated to evaluate bone metabolism. Results In every group, the uptake ratio increased until 7 days after load application and then gradually decreased. It was significantly higher than baseline at 4, 7, 11, and 14 days (P < 0.001). The uptake ratio in the 1-D EL and 3-D EL groups were significantly higher than that in the control group and also that in the IL group (P < 0.001). Conclusions Bone metabolism initially increased and then gradually decreased to baseline despite differences in load timing. Increases in bone metabolic activity differed according to load application timing; the later the load application, the more enhanced the bone metabolism.
- Open Access
- 18 August 2012
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (10) , 817-822
Time course of bone metabolism at the residual ridge beneath dentures observed using 18F-fluoride positron emission computerized-tomography/computed tomography (PET/CT)
Excessive pressure due to wearing mal-adapting dentures is well known to cause residual bone resorption beneath the denture. X-rays have been commonly utilized to evaluate the changes in the bone beneath the denture. However, X-ray images merely detect bone density and relatively large changes in the bone shape and structure, whereas nuclear medicine imaging can detect functional changes, which occur prior to structural changes. This article aimed to describe the time course of the bone metabolism at the residual ridge beneath the denture following denture use by 18F-fluoride positron emission computerized-tomography (PET)/computed tomography (CT) scanning. Three subjects, who had a free-end edentulous mandible, were treated with a denture replacing the edentulous region of the dental arch. The metabolic changes in the residual bone beneath the denture were assessed by 18F-fluoride PET/CT imaging. 18F-fluoride PET/CT scanning was performed at baseline, and 4–6 and 13 weeks after denture use. A volume of interest (VOI) was placed on their mandibles at the edentulous region beneath the denture on the PET/CT image. CT value and mean standardized uptake value (SUV) of the VOI were calculated. The difference in the time variation between the CT value and SUV was analyzed. The adaptation of the denture base to the residual ridge was successful, and there was no trouble such as pain at the residual ridge beneath the denture. The SUVs of each VOI significantly increased at 4–6 weeks after denture use and then decreased at 13 weeks in all three subjects (P < 0.05; two-way ANOVA, Dunnett test). On the other hand, the CT images showed no obvious changes in the bone shape or structure beneath the dentures, and the CT values of each VOI remained static after denture use in all three subjects. This study indicates that in the present first-time removable partial denture (RPD) users, wearing of a well-adapted RPD initially increased bone metabolism beneath the denture and then decreased it at around 13 weeks after RPD use without any bone structural changes detectable by clinical X-rays. These metabolic changes are a mechanobiological reaction to the pressure induced by RPD use.
- 18 August 2012
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (10) , 817-822
Open AccessTime course of bone metabolism at the residual ridge beneath dentures observed using 18F-fluoride positron emission computerized-tomography/computed tomography (PET/CT)
Excessive pressure due to wearing mal-adapting dentures is well known to cause residual bone resorption beneath the denture. X-rays have been commonly utilized to evaluate the changes in the bone beneath the denture. However, X-ray images merely detect bone density and relatively large changes in the bone shape and structure, whereas nuclear medicine imaging can detect functional changes, which occur prior to structural changes. This article aimed to describe the time course of the bone metabolism at the residual ridge beneath the denture following denture use by 18F-fluoride positron emission computerized-tomography (PET)/computed tomography (CT) scanning. Three subjects, who had a free-end edentulous mandible, were treated with a denture replacing the edentulous region of the dental arch. The metabolic changes in the residual bone beneath the denture were assessed by 18F-fluoride PET/CT imaging. 18F-fluoride PET/CT scanning was performed at baseline, and 4–6 and 13 weeks after denture use. A volume of interest (VOI) was placed on their mandibles at the edentulous region beneath the denture on the PET/CT image. CT value and mean standardized uptake value (SUV) of the VOI were calculated. The difference in the time variation between the CT value and SUV was analyzed. The adaptation of the denture base to the residual ridge was successful, and there was no trouble such as pain at the residual ridge beneath the denture. The SUVs of each VOI significantly increased at 4–6 weeks after denture use and then decreased at 13 weeks in all three subjects (P < 0.05; two-way ANOVA, Dunnett test). On the other hand, the CT images showed no obvious changes in the bone shape or structure beneath the dentures, and the CT values of each VOI remained static after denture use in all three subjects. This study indicates that in the present first-time removable partial denture (RPD) users, wearing of a well-adapted RPD initially increased bone metabolism beneath the denture and then decreased it at around 13 weeks after RPD use without any bone structural changes detectable by clinical X-rays. These metabolic changes are a mechanobiological reaction to the pressure induced by RPD use.
- 18 March 2010
- Vol. 23 (1) , 38-41
Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
The retentive force of a wire clasp composed of a b-type Ti-6Mo-4Sn alloy (b-Ti alloy) with a low Young modulus was evaluated using a piezoelectric transducer to determine the appropriate undercut for removable partial dentures. There were no significant differences in retentive force between a b-Ti alloy wire with a 0.50-mm undercut and a cobalt-chromium alloy (Co-Cr alloy) wire with a 0.25-mm undercut, or between a b-Ti alloy wire with a 0.75-mm undercut and a Co-Cr alloy wire with a 0.50-mm undercut. The b-Ti alloy wire may be applicable for abutment teeth with a large number of undercuts. Int J Prosthodont 2010;23:38-41.
- 18 March 2010
- Vol. 23 (1) , 38-41
Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
The retentive force of a wire clasp composed of a b-type Ti-6Mo-4Sn alloy (b-Ti alloy) with a low Young modulus was evaluated using a piezoelectric transducer to determine the appropriate undercut for removable partial dentures. There were no significant differences in retentive force between a b-Ti alloy wire with a 0.50-mm undercut and a cobalt-chromium alloy (Co-Cr alloy) wire with a 0.25-mm undercut, or between a b-Ti alloy wire with a 0.75-mm undercut and a Co-Cr alloy wire with a 0.50-mm undercut. The b-Ti alloy wire may be applicable for abutment teeth with a large number of undercuts. Int J Prosthodont 2010;23:38-41.
- 19 November 2008
- Vol. 23 (5) , 827-34
Bone metabolic activity around dental implants under loading observed using bone scintigraphy.
The purpose of this study was to determine dynamic changes in bone metabolism around osseointegrated titanium implants under mechanical stress. Two titanium implants were inserted parallel to each other in the tibiae of rats and perpendicular to the bone surface with the superior aspect of the implant exposed. Eight weeks after insertion, closed coil springs with 0.5, 1.0, 2.0, and 4.0 N were applied to the exposed superior portion of the implant for 7 weeks to apply a continuous mechanical stress. Bone scintigrams were performed using a gamma camera with a modified high-resolution pinhole collimator. Images were made at 1, 4, 7, 10, 14, 21, 28, 49, and 56 days after insertion and at 3 days and at weekly intervals until 7 weeks after load application. The ratio of the metabolic activity around the implants to that around a reference site (uptake ratio) was established. The Friedman, Steel, and Tukey tests (P < .05) were used to assess statistical significance. In the process of osseointegration, the uptake ratio increased during the first week after implant insertion and then gradually decreased. During the initial 3 weeks the uptake ratio was significantly higher than at 1 day after insertion. In the process of load application, the uptake ratio increased with 2.0- and 4.0-N loads; it was significantly higher until 6 weeks than it had been before load application. Bone metabolism around the implants increases with loading and depends on the magnitude and period of the loading.
- 19 November 2008
- Vol. 23 (5) , 827-34
Bone metabolic activity around dental implants under loading observed using bone scintigraphy.
The purpose of this study was to determine dynamic changes in bone metabolism around osseointegrated titanium implants under mechanical stress. Two titanium implants were inserted parallel to each other in the tibiae of rats and perpendicular to the bone surface with the superior aspect of the implant exposed. Eight weeks after insertion, closed coil springs with 0.5, 1.0, 2.0, and 4.0 N were applied to the exposed superior portion of the implant for 7 weeks to apply a continuous mechanical stress. Bone scintigrams were performed using a gamma camera with a modified high-resolution pinhole collimator. Images were made at 1, 4, 7, 10, 14, 21, 28, 49, and 56 days after insertion and at 3 days and at weekly intervals until 7 weeks after load application. The ratio of the metabolic activity around the implants to that around a reference site (uptake ratio) was established. The Friedman, Steel, and Tukey tests (P < .05) were used to assess statistical significance. In the process of osseointegration, the uptake ratio increased during the first week after implant insertion and then gradually decreased. During the initial 3 weeks the uptake ratio was significantly higher than at 1 day after insertion. In the process of load application, the uptake ratio increased with 2.0- and 4.0-N loads; it was significantly higher until 6 weeks than it had been before load application. Bone metabolism around the implants increases with loading and depends on the magnitude and period of the loading.