Vilas U. Chavan
Research Subjects
Vilas U. Chavan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Ajit V. Sontakke
KIMS
1 shared publicationAnjum K. Sayyed
KIMS
1 shared publicationBhavika S Rana
1 shared publicationKalpeshkumar Chhaganbhai Nakarani
1 shared publicationNazir R. Attar
K.S. Hegde Medical Academy and K.S. Hegde Hospital Deralkatte
1 shared publicationPushpa P. Durgawale
KIMS
1 shared publication
Latest Publications
- 1 January 2019
- Published by Statperson Publishing Coporation in MedPulse International Journal of Biochemistry
- Vol. 12 (2) , 66-71
Study of various biochemical parameters in tuberculosis patients: A hospital based crosssectional study
- 1 January 2019
- Published by Statperson Publishing Coporation in MedPulse International Journal of Biochemistry
- Vol. 12 (2) , 66-71
Study of various biochemical parameters in tuberculosis patients: A hospital based crosssectional study
- Open Access
- 1 April 2015
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 9 (4) , BC01-5
Evaluation of Serum Magnesium, Lipid Profile and Various Biochemical Parameters as Risk Factors of Cardiovascular Diseases in Patients with Rheumatoid Arthritis
Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.
- 1 April 2015
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 9 (4) , BC01-5
Open AccessEvaluation of Serum Magnesium, Lipid Profile and Various Biochemical Parameters as Risk Factors of Cardiovascular Diseases in Patients with Rheumatoid Arthritis
Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.
- 30 April 2011
- Published by Springer Nature in Indian Journal of Clinical Biochemistry
- Vol. 26 (3) , 283-289
A Comparative Study of Clinical Utility of Spot Urine Samples with 24-h Urine Albumin Excretion for Screening of Microalbuminuria in Type 2 Diabetic Patients
Twenty-four hour urinary albumin excretion (UAE) is considered as gold standard method for albuminuria measurement, but collection of 24-h urine is inconvenient. The aim of present study was to evaluate whether albumin: creatinine ratio (ACR) and urinary albumin concentration (UAC) in different spot urine samples correlate or not with 24-h UAE for screening of microalbuminuria in type 2 diabetic patients. We collected first morning void (FMV), random urine sample (RUS) and 24-h urine, separately on consecutive days from 104 type 2 diabetic patients. ACR and UAC in each spot urine sample compared with 24-h UAE with regard to Pearson correlation coefficient. Pearson’s correlation of albumin: creatinine ratio (ACR) with 24-h UAE was (r = 0.802 and 0.623) in first morning void (FMV) and random urine sample (RUS), respectively. Pearson’s correlation coefficient of urinary albumin concentration (UAC) compared with 24-h UAE was (r = 0.943 and 0.920), in FMV and RUS, respectively, P < 0.01. Results revealed that values in first morning void (FMV) were better correlated with 24-h urinary albumin excretion (UAE), than the values in random urine sample (RUS). We conclude that the first morning void (FMV) may be able to replace 24-h urine collection, preferably urinary albumin concentration (UAC) in the initial screening of microalbuminuria in diabetic patients.
- 30 April 2011
- Published by Springer Nature in Indian Journal of Clinical Biochemistry
- Vol. 26 (3) , 283-289
A Comparative Study of Clinical Utility of Spot Urine Samples with 24-h Urine Albumin Excretion for Screening of Microalbuminuria in Type 2 Diabetic Patients
Twenty-four hour urinary albumin excretion (UAE) is considered as gold standard method for albuminuria measurement, but collection of 24-h urine is inconvenient. The aim of present study was to evaluate whether albumin: creatinine ratio (ACR) and urinary albumin concentration (UAC) in different spot urine samples correlate or not with 24-h UAE for screening of microalbuminuria in type 2 diabetic patients. We collected first morning void (FMV), random urine sample (RUS) and 24-h urine, separately on consecutive days from 104 type 2 diabetic patients. ACR and UAC in each spot urine sample compared with 24-h UAE with regard to Pearson correlation coefficient. Pearson’s correlation of albumin: creatinine ratio (ACR) with 24-h UAE was (r = 0.802 and 0.623) in first morning void (FMV) and random urine sample (RUS), respectively. Pearson’s correlation coefficient of urinary albumin concentration (UAC) compared with 24-h UAE was (r = 0.943 and 0.920), in FMV and RUS, respectively, P < 0.01. Results revealed that values in first morning void (FMV) were better correlated with 24-h urinary albumin excretion (UAE), than the values in random urine sample (RUS). We conclude that the first morning void (FMV) may be able to replace 24-h urine collection, preferably urinary albumin concentration (UAC) in the initial screening of microalbuminuria in diabetic patients.