Raghuwar Dayal Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Raghuwar Dayal Singh has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Pooran Chand
9 shared publications- Himanshi Aggarwal
Department of Prosthodontics, Faculty of Dental Sciences, King George's Medical University, Lucknow, Uttar Pradesh, India
4 shared publications Pradeep Kumar
Department of Prosthodontics, Faculty of Dental Sciences, King George's Medical University UP, Lucknow, Uttar Pradesh, India
4 shared publicationsRamashanker
Assistant Professor, Department of Prosthodontics, Faculty of Dental Sciences, Chhatrapati Shahuji Maharaj Medical University (Erstwhile King George Medical College), Lucknow, India
3 shared publicationsRamashanker Siddhartha
Associate Professor, Department of Prosthodontics, Faculty of Dental Sciences King George's Medical University UP Lucknow India
3 shared publications- Sanjiv Kumar Gupta
Department of Ophthalmology, King Georges Medical University, Lucknow, Uttar Pradesh, India
3 shared publications
Latest Publications
- Open Access
- 30 September 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41 (3) , 64-73
Evaluating the clinical and radiographic outcomes of mini-implant versus conventional implant-supported overdentures: A three-year randomized control prospective study
Anusar Gupta, Niraj Mishra, Pooran Chand, Saumyendra Vikram Singh, Raghuwar Dayal Singh, Bhaskar Agarwal, Deeksha Arya, Anupama Pathak. Journal of Dental Implant Research 2022;41:64-73. https://doi.org/10.54527/jdir.2022.41.3.64
- 30 September 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41 (3) , 64-73
Open AccessEvaluating the clinical and radiographic outcomes of mini-implant versus conventional implant-supported overdentures: A three-year randomized control prospective study
Anusar Gupta, Niraj Mishra, Pooran Chand, Saumyendra Vikram Singh, Raghuwar Dayal Singh, Bhaskar Agarwal, Deeksha Arya, Anupama Pathak. Journal of Dental Implant Research 2022;41:64-73. https://doi.org/10.54527/jdir.2022.41.3.64
- Open Access
- 4 September 2020
- Published by Heighten Science Publications Corporation in Journal of Clinical Advances in Dentistry
- Vol. 4 (1) , 028-029
A Simplified approach for fabrication of custom tray for Facial prosthesis
Maxillofacial defects are very common and can be due to congenital defect, trauma, infections and neoplasms of facial region. These defects can be restored using different materials and retention methods to give a life like appearance. Rehabilitation of facial defect is a very challenging task. Every good prosthesis needs a skillful hand and it all starts with making a good impression of that defect and to proceed with the same. The aim of present paper was to present a simplified approach for the fabrication of custom tray to take facial impression of the patient with maxillofacial defect.
- 4 September 2020
- Published by Heighten Science Publications Corporation in Journal of Clinical Advances in Dentistry
- Vol. 4 (1) , 028-029
Open AccessA Simplified approach for fabrication of custom tray for Facial prosthesis
Maxillofacial defects are very common and can be due to congenital defect, trauma, infections and neoplasms of facial region. These defects can be restored using different materials and retention methods to give a life like appearance. Rehabilitation of facial defect is a very challenging task. Every good prosthesis needs a skillful hand and it all starts with making a good impression of that defect and to proceed with the same. The aim of present paper was to present a simplified approach for the fabrication of custom tray to take facial impression of the patient with maxillofacial defect.
- 1 April 2015
- p. S61-3
An Integrated Approach for Cosmetic Rehabilitation of a Patient with Atrophia bulbi.
Atrophia bulbiis a small, shrunken, non-functional eye, most commonly due to trauma. It represents an ocular end-stage disease characterized by atrophy, shrinkage, and disorganization of the eyeball and intraocular contents, demonstrating the result of failed previous ocular therapy in which restoration of the morphologic and functional integrity of the eye is not possible. Majority of the patients with Atrophia bulbi eventually become blind and cosmetically unacceptable. The rehabilitation of such patients presents a challenging clinical situation, as the patient has already been clouded by the psychological distress. This paper demonstrates a case of 35-year male with Atrophia bulbi, who was successfully rehabilitated with precisely fabricated ocular prosthesis fitted over the atrophic eye.
- 1 April 2015
- p. S61-3
An Integrated Approach for Cosmetic Rehabilitation of a Patient with Atrophia bulbi.
Atrophia bulbiis a small, shrunken, non-functional eye, most commonly due to trauma. It represents an ocular end-stage disease characterized by atrophy, shrinkage, and disorganization of the eyeball and intraocular contents, demonstrating the result of failed previous ocular therapy in which restoration of the morphologic and functional integrity of the eye is not possible. Majority of the patients with Atrophia bulbi eventually become blind and cosmetically unacceptable. The rehabilitation of such patients presents a challenging clinical situation, as the patient has already been clouded by the psychological distress. This paper demonstrates a case of 35-year male with Atrophia bulbi, who was successfully rehabilitated with precisely fabricated ocular prosthesis fitted over the atrophic eye.
- Open Access
- 4 August 2014
- Published by Hindawi Limited in BioMed Research International
- Vol. 2014, 1-6
Mercury and Other Biomedical Waste Management Practices among Dental Practitioners in India
Objectives. The objective of the study was to assess the awareness and performance towards dental waste including mercury management policy and practices among the dental practitioners in North India.Materials and Methods. An epidemiologic survey was conducted among 200 private dental practitioners. The survey form was composed of 29 self-administered questions frame based on knowledge, attitude, and those regarding the practices of dentists in relation to dental health-care waste management. The resulting data were coded and a statistical analysis was done.Results and Discussion. About 63.7% of the dentists were not aware of the different categories of biomedical waste generated in their clinics. Only 31.9% of the dentists correctly said that outdated and contaminated drugs come under cytotoxic waste. 46.2% said they break the needle and dispose of it and only 21.9% use needle burner to destroy it. 45.0% of the dentists dispose of the developer and fixer solutions by letting them into the sewer, 49.4% of them dilute the solutions and let them into sewer and only 5.6% return them to the supplier. About 40.6% of the dentists dispose of excess silver amalgam by throwing it into common bin.Conclusion. It was concluded that not all dentists were aware of the risks they were exposed to and only half of them observe infection control practices.
- 4 August 2014
- Published by Hindawi Limited in BioMed Research International
- Vol. 2014, 1-6
Open AccessMercury and Other Biomedical Waste Management Practices among Dental Practitioners in India
Objectives. The objective of the study was to assess the awareness and performance towards dental waste including mercury management policy and practices among the dental practitioners in North India.Materials and Methods. An epidemiologic survey was conducted among 200 private dental practitioners. The survey form was composed of 29 self-administered questions frame based on knowledge, attitude, and those regarding the practices of dentists in relation to dental health-care waste management. The resulting data were coded and a statistical analysis was done.Results and Discussion. About 63.7% of the dentists were not aware of the different categories of biomedical waste generated in their clinics. Only 31.9% of the dentists correctly said that outdated and contaminated drugs come under cytotoxic waste. 46.2% said they break the needle and dispose of it and only 21.9% use needle burner to destroy it. 45.0% of the dentists dispose of the developer and fixer solutions by letting them into the sewer, 49.4% of them dilute the solutions and let them into sewer and only 5.6% return them to the supplier. About 40.6% of the dentists dispose of excess silver amalgam by throwing it into common bin.Conclusion. It was concluded that not all dentists were aware of the risks they were exposed to and only half of them observe infection control practices.
- 1 June 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 111 (6) , 525-528
Prosthetic guidelines for ocular rehabilitation in patients with phthisis bulbi: A treatment-based classification system
- 1 June 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 111 (6) , 525-528
Prosthetic guidelines for ocular rehabilitation in patients with phthisis bulbi: A treatment-based classification system
- 19 July 2013
- Published by Wiley in Journal of Prosthodontics
- Vol. 22 (5) , 358-361
High Performance Liquid Chromatographic Determination of Residual Monomer Released from Heat‐Cured Acrylic Resin. An In Vivo Study
Purpose: Heat‐polymerized acrylic resins are used in dentistry for complete denture fabrication. Despite the polymerization method, conversion of monomer into polymer is often incomplete with free or unreacted residual monomer remaining in the polymerized resin. The aim of this study was to determine the amount of residual monomeric methyl methacrylate (MMA) leaching in the saliva of patients wearing complete dentures in their postinsertion period.Materials and Methods: Thirty edentulous participants as first‐time complete denture wearers (age 60 to 65 years) were selected. All the prostheses were fabricated using a similar standard technique with a heat‐cured acrylic resin denture base material. Saliva samples were collected at time intervals of 1 hour, 1 day, and 3 days postdenture insertion. Participants were asked to discharge saliva every 30 seconds into a pre‐weighed screw‐capped container for a 5‐minute period. MMA levels were measured using high performance liquid chromatography. Data were analyzed by ANOVA and Tukey‐HSD.Results: The maximum concentration of monomer released into saliva peaked 1 day after insertion of the complete dentures. The mean (SD) MMA content was 0.04 ± 0.01 (μg/ml) 1 hour after insertion, and 0.3 ± 0.09 (μg/ml), and 0.05 ± 0.01 (μg/ml) on the first and third days postinsertion, respectively.Conclusions: Although the released monomeric MMA was not at toxic levels, it could potentially sensitize complete denture patients or elicit an allergic reaction. The risk of the residual material as a primary irritant for a sensitizing reaction could be minimized by immersion of the denture in water for 24 hours before insertion.
- 19 July 2013
- Published by Wiley in Journal of Prosthodontics
- Vol. 22 (5) , 358-361
High Performance Liquid Chromatographic Determination of Residual Monomer Released from Heat‐Cured Acrylic Resin. An In Vivo Study
Purpose: Heat‐polymerized acrylic resins are used in dentistry for complete denture fabrication. Despite the polymerization method, conversion of monomer into polymer is often incomplete with free or unreacted residual monomer remaining in the polymerized resin. The aim of this study was to determine the amount of residual monomeric methyl methacrylate (MMA) leaching in the saliva of patients wearing complete dentures in their postinsertion period.Materials and Methods: Thirty edentulous participants as first‐time complete denture wearers (age 60 to 65 years) were selected. All the prostheses were fabricated using a similar standard technique with a heat‐cured acrylic resin denture base material. Saliva samples were collected at time intervals of 1 hour, 1 day, and 3 days postdenture insertion. Participants were asked to discharge saliva every 30 seconds into a pre‐weighed screw‐capped container for a 5‐minute period. MMA levels were measured using high performance liquid chromatography. Data were analyzed by ANOVA and Tukey‐HSD.Results: The maximum concentration of monomer released into saliva peaked 1 day after insertion of the complete dentures. The mean (SD) MMA content was 0.04 ± 0.01 (μg/ml) 1 hour after insertion, and 0.3 ± 0.09 (μg/ml), and 0.05 ± 0.01 (μg/ml) on the first and third days postinsertion, respectively.Conclusions: Although the released monomeric MMA was not at toxic levels, it could potentially sensitize complete denture patients or elicit an allergic reaction. The risk of the residual material as a primary irritant for a sensitizing reaction could be minimized by immersion of the denture in water for 24 hours before insertion.
- Open Access
- 1 January 2013
- Published by Scientific Scholar in Indian Journal of Palliative Care
- Vol. 19 (1) , 67-70
A palliative approach for rehabilitation of a pediatric patient with retinoblastoma
Retinoblastoma is a highly malignant neoplasm. Most of the cases are usually far advanced at the time of detection, requiring enucleation to salvage the child's life. However, the cosmetic rehabilitation of these patients should always be an integral part of their treatment, which helps in their re-integration in the society. This paper presents a case of 5-year-old patient who had undergone enucleation of her left eye due to retinoblastoma. A multidisciplinary approach, including ophthalmologist, psychotherapist, and a prosthodontist, was adopted to meet her physical, psychological, functional, emotional, social, and cosmetic demands. The patient was rehabilitated cosmetically with precisely fabricated ocular prosthesis. An ocular prosthesis is a highly positive and non-invasive approach to improve the cosmetic appearance and psychological well-being of patient.
- 1 January 2013
- Published by Scientific Scholar in Indian Journal of Palliative Care
- Vol. 19 (1) , 67-70
Open AccessA palliative approach for rehabilitation of a pediatric patient with retinoblastoma
Retinoblastoma is a highly malignant neoplasm. Most of the cases are usually far advanced at the time of detection, requiring enucleation to salvage the child's life. However, the cosmetic rehabilitation of these patients should always be an integral part of their treatment, which helps in their re-integration in the society. This paper presents a case of 5-year-old patient who had undergone enucleation of her left eye due to retinoblastoma. A multidisciplinary approach, including ophthalmologist, psychotherapist, and a prosthodontist, was adopted to meet her physical, psychological, functional, emotional, social, and cosmetic demands. The patient was rehabilitated cosmetically with precisely fabricated ocular prosthesis. An ocular prosthesis is a highly positive and non-invasive approach to improve the cosmetic appearance and psychological well-being of patient.
- Open Access
- 18 October 2012
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 14 (1) , 124-127
A Simplified Approach for Placing the Iris Disc on a Custom Made Ocular Prosthesis: Report of Four Cases
This case report describes a series of four cases of different age group, in which a simplified approach was applied for positioning the iris disc on a custom made ocular prosthesis. For each of the patient, a pre-fabricated eye was selected; whose iris and pupil closely matched that of the natural eye. This was duplicated for use as a tray in impression procedure. Iris portion of the stock eye was trimmed out and oriented on the cast according to previously transferred pupillary mark. This stock eye-wax pattern combination was tested in the eye socket, modified accordingly and finally cured in transparent heat cured acrylic resin. The technique to fabricate ocular prosthesis in present case reports modifies pre-fabricated eye prosthesis to a custom-made fit and aesthetics. This helped us to overcome the disadvantages of poor fit, inadequate movement and complex painting procedure and technique involved in making a custom-made ocular prosthesis. It can be concluded that close adaptation of the custom-made ocular prosthesis to the tissue bed provides maximum comfort and restores full physiologic function to the accessory organs of the eye.
- 18 October 2012
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 14 (1) , 124-127
Open AccessA Simplified Approach for Placing the Iris Disc on a Custom Made Ocular Prosthesis: Report of Four Cases
This case report describes a series of four cases of different age group, in which a simplified approach was applied for positioning the iris disc on a custom made ocular prosthesis. For each of the patient, a pre-fabricated eye was selected; whose iris and pupil closely matched that of the natural eye. This was duplicated for use as a tray in impression procedure. Iris portion of the stock eye was trimmed out and oriented on the cast according to previously transferred pupillary mark. This stock eye-wax pattern combination was tested in the eye socket, modified accordingly and finally cured in transparent heat cured acrylic resin. The technique to fabricate ocular prosthesis in present case reports modifies pre-fabricated eye prosthesis to a custom-made fit and aesthetics. This helped us to overcome the disadvantages of poor fit, inadequate movement and complex painting procedure and technique involved in making a custom-made ocular prosthesis. It can be concluded that close adaptation of the custom-made ocular prosthesis to the tissue bed provides maximum comfort and restores full physiologic function to the accessory organs of the eye.
- 30 August 2012
- Vol. 25 (5) , 497-505
Computed tomographic evaluation of the effects of mandibular advancement devices on pharyngeal dimension changes in patients with obstructive sleep apnea.
The aims of this study were to evaluate the effect of a mandibular advancement device on oropharyngeal dimension in patients with obstructive sleep apnea (OSA) and reveal the predominate site of changes produced by mandibular advancement using computed tomography (CT). CT scans of 20 patients diagnosed with OSA were taken with and without the appliance. Three-dimensional changes in pharyngeal shape measured on cross-sectional CT images during two respiratory cycles after oral appliance insertion were estimated at five vertical levels using three variables: (1) lateral dimension, (2) anteroposterior dimension, and (3) cross-sectional area. Various parameters related to severity of OSA such as snoring volume, frequency, duration, and episodes; breathing pauses; oxygen saturation; Epworth Sleepiness Scale (ESS) score; and Apnea Hypopnea Index (AHI) score underwent comparative evaluation subjectively and objectively. Data were analyzed using the Student t test for parametric analysis. A significant increase in the lateral and anteroposterior dimension of the pharyngeal lumen was observed at all five levels, but the mean change was greatest at the retroglossal level and smallest at the hypopharyngral level in both the lateral and anteroposterior dimensions. The cross-sectional area at all levels appeared to increase significantly, and apnea indices improved significantly. A significant decrease in snoring volume, snoring frequency, breathing pauses, snoring duration, snoring episodes, ESS score, and AHI score and a significant increase in oxygen saturation were found after treatment with the mandibular advancement device. Within the limitations of this study, CT was shown to be useful in evaluating treatment efficacy in subjects with OSA.
- 30 August 2012
- Vol. 25 (5) , 497-505
Computed tomographic evaluation of the effects of mandibular advancement devices on pharyngeal dimension changes in patients with obstructive sleep apnea.
The aims of this study were to evaluate the effect of a mandibular advancement device on oropharyngeal dimension in patients with obstructive sleep apnea (OSA) and reveal the predominate site of changes produced by mandibular advancement using computed tomography (CT). CT scans of 20 patients diagnosed with OSA were taken with and without the appliance. Three-dimensional changes in pharyngeal shape measured on cross-sectional CT images during two respiratory cycles after oral appliance insertion were estimated at five vertical levels using three variables: (1) lateral dimension, (2) anteroposterior dimension, and (3) cross-sectional area. Various parameters related to severity of OSA such as snoring volume, frequency, duration, and episodes; breathing pauses; oxygen saturation; Epworth Sleepiness Scale (ESS) score; and Apnea Hypopnea Index (AHI) score underwent comparative evaluation subjectively and objectively. Data were analyzed using the Student t test for parametric analysis. A significant increase in the lateral and anteroposterior dimension of the pharyngeal lumen was observed at all five levels, but the mean change was greatest at the retroglossal level and smallest at the hypopharyngral level in both the lateral and anteroposterior dimensions. The cross-sectional area at all levels appeared to increase significantly, and apnea indices improved significantly. A significant decrease in snoring volume, snoring frequency, breathing pauses, snoring duration, snoring episodes, ESS score, and AHI score and a significant increase in oxygen saturation were found after treatment with the mandibular advancement device. Within the limitations of this study, CT was shown to be useful in evaluating treatment efficacy in subjects with OSA.
- 27 March 2012
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 100B (5) , 1444-1450
Biocompatibility of polymethylmethacrylate resins used in dentistry
Biocompatibility or tissue compatibility describes the ability of a material to perform with an appropriate host response when applied as intended. Poly‐methylmethacrylate (PMMA) based resins are most widely used resins in dentistry, especially in fabrication of dentures and orthodontic appliances. They are considered cytotoxic on account of leaching of various potential toxic substances, most common being residual monomer. Various in vitro and in vivo experiments and cell based studies conducted on acrylic based resins or their leached components have shown them to have cytotoxic effects. They can cause mucosal irritation and tissue sensitization. These studies are not only important to evaluate the long term clinical effect of these materials, but also help in further development of alternate resins. This article reviews information from scientific full articles, reviews, or abstracts published in dental literature, associated with biocompatibility of PMMA resins and it is leached out components. Published materials were searched in dental literature using general and specialist databases, like the PubMED database. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.
- 27 March 2012
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 100B (5) , 1444-1450
Biocompatibility of polymethylmethacrylate resins used in dentistry
Biocompatibility or tissue compatibility describes the ability of a material to perform with an appropriate host response when applied as intended. Poly‐methylmethacrylate (PMMA) based resins are most widely used resins in dentistry, especially in fabrication of dentures and orthodontic appliances. They are considered cytotoxic on account of leaching of various potential toxic substances, most common being residual monomer. Various in vitro and in vivo experiments and cell based studies conducted on acrylic based resins or their leached components have shown them to have cytotoxic effects. They can cause mucosal irritation and tissue sensitization. These studies are not only important to evaluate the long term clinical effect of these materials, but also help in further development of alternate resins. This article reviews information from scientific full articles, reviews, or abstracts published in dental literature, associated with biocompatibility of PMMA resins and it is leached out components. Published materials were searched in dental literature using general and specialist databases, like the PubMED database. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.