PVPatrick Veit-Haibach

Patrick Veit-Haibach

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Patrick Veit-Haibach has a total of 97 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Value of 18F-FET PET in adult brainstem glioma

    by Abdulrahman Abdullah Albatly, Adnan Taleb Alsamarah, Abdulrahman Alhawas, Patrick Veit-Haibach, Alfred Buck, Paul Stolzmann, Irene A. Burger, Spyros S. Kollias, Martin W. Huellner


  • Multi-technique hybrid imaging in PET/CT and PET/MR: what does the future hold?

    by F. de Galiza Barbosa, G. Delso, E.E.G.W. ter Voert, M.W. Huellner, K. Herrmann, P. Veit-Haibach


  • Diagnostic accuracy of sequential co-registered PET+MR in comparison to PET/CT in local thoracic staging of malignant pleural mesothelioma

    by Katharina Martini, Andreas Meier, Isabelle Opitz, Walter Weder, Patrick Veit-Haibach, Rolf A. Stahel, Thomas Frauenfelder


  • Open Access

    Combined PET/CT-perfusion in patients with head and neck cancers might predict failure after radio-chemotherapy: a proof of concept study

    by Carsten Pietsch, Felipe de Galiza Barbosa, Martin W. Hüllner, Daniel T. Schmid, Stephan K. Haerle, Gerhard F. Huber, Gabriela Studer, Thomas F. Hany, Patrick Veit-Haibach

    [18F]FDG-PET/CT imaging is broadly used in head and neck cancer (HNSCC) patients. CT perfusion (CTP) is known to provide information about angiogenesis and blood-flow characteristics in tumors. The aim of this study was to evaluate the potential relationship of FDG-parameters and CTP-parameters in HNSCC preand post-therapy and the potential prognostic value of a combined PET/CT with CTP. Thirteen patients with histologic proven HNSCC were prospectively included. All patients underwent a combined PET/CT with integrated CTP before and after therapy. Pre- and post-therapeutic data of CTP and PET of the tumors were compared. Differences were tested using Spearman’s rho test and Pearson’s correlation. A p-value of p <0.05 was considered statistically significant. Correlations were calculated using Pearson’s correlation. Bootstrap confidence intervals were calculated to test for additive confidence intervals. Three patients died due to malignancy recurrence, ten patients were free of recurrence until the end of the follow-up period. Patients with recurrent disease had significantly higher initial CTP-values compared to the recurrence-free patients: BFpre 267.4 (171.2)ml/100 mg/min, BVpre 40.9 (8.4)ml/100 mg and MTTpre 8.2 (6.1)sec. No higher SUVs initially but significantly higher TLG compared to patients without recurrence were found. Post-therapeutic PET-values differed significantly between the two groups: SUVmaxpost 6.0 (3.2), SUVmeanpost 3.6 (2.0) and TLG 21751.7 (29794.0). In our proof of concept study, combined PET/CT with integrated CTP might show complementary prognostic data pre- and post chemo-radiotherapy. CTP may be used to predict local tumor recurrence, while FDGPET/CT is still needed for whole-body staging.


  • Open Access

    Diagnostic performance of FDG-PET/MRI and WB-DW-MRI in the evaluation of lymphoma: a prospective comparison to standard FDG-PET/CT

    by Ken Herrmann, Marcelo Queiroz, Martin W. Huellner, Felipe de Galiza Barbosa, Andreas Buck, Niklaus Schaefer, Paul Stolzman, Patrick Veit-Haibach

    Use of FDG-PET/CT for staging and restaging of lymphoma patients is widely incorporated into current practice guidelines. Our aim was to prospectively evaluate the diagnostic performance of FDG-PET/MRI and WB-DW-MRI compared with FDG-FDG-PET/CT using a tri-modality PET/CT-MRI system. From 04/12 to 01/14, a total of 82 FDG-PET/CT examinations including an additional scientific MRI on a tri-modality setup were performed in 61 patients. FDG-PET/CT, FDG-PET/MRI, and WB-DW-MRI were independently analyzed. A lesion with a mean ADC below a threshold of 1.2 × 10−3 mm2/s was defined as positive for restricted diffusion. FDG-PET/CT and FDG-PET/MRI were evaluated for the detection of lesions corresponding to lymphoma manifestations according to the German Hodgkin Study Group. Imaging findings were validated by biopsy (n = 21), by follow-up imaging comprising CT, FDG-PET/CT, and/or FDG-PET/MRI (n = 32), or clinically (n = 25) (mean follow-up: 9.1 months). FDG-PET/MRI and FDG-PET/CT accurately detected 188 lesions in 27 patients. Another 54 examinations in 35 patients were negative. WB-DW-MRI detected 524 lesions, of which 125 (66.5 % of the aforementioned 188 lesions) were true positive. Among the 188 lesions positive for lymphoma, FDG-PET/MRI detected all 170 instances of nodal disease and also all 18 extranodal lymphoma manifestations; by comparison, WB-DW-MRI characterized 115 (67.6 %) and 10 (55.6 %) lesions as positive for nodal and extranodal disease, respectively. FDG-PET/MRI was superior to WB-DW-MRI in detecting lymphoma manifestations in patients included for staging (113 vs. 73), for restaging (75 vs. 52), for evaluation of high- (127 vs. 81) and low-grade lymphomas (61 vs. 46), and for definition of Ann Arbor stage (WB-DW-MRI resulted in upstaging in 60 cases, including 45 patients free of disease, and downstaging in 4). Our results indicate that FDG-PET/CT and FDG-PET/MRI probably have a similar performance in the clinical work-up of lymphomas. The performance of WB-DW-MRI was generally inferior to that of both FDG-PET-based methods but the technique might be used in specific scenarios, e.g., in low-grade lymphomas and during surveillance.


  • Open Access

    Osseous vitality in single photon emission computed tomography/computed tomography (SPECT/CT) after balloon tibioplasty of the tibial plateau: a case series

    by Thorsten Jentzsch, Yannick Fritz, Patrick Veit-Haibach, Jürgen Schmitt, Kai Sprengel, Clément M. L. Werner

    The minimally invasive, balloon-assisted reduction and cement-augmented internal fixation of the tibial plateau is an innovative surgical procedure for tibial plateau fractures. The close proximity of balloons and cement to the knee joint poses a potential risk for osteonecrosis; especially in the case of thin bone lamellae. However, there are no studies about the vitality of the cement-surrounding tissue after these tibioplasties. Therefore, our goal was to assess the osseous vitality after cement-augmented balloon tibioplasty using single photon emission computed tomography/computed tomography (SPECT/CT) in a series of patients. This case series evaluated available consecutive patients, whose tibial plateau fractures were treated with balloon-assisted, cement-augmented tibioplasty and received a SPECT/CT. Primary outcome variables were osseous vitality on SPECT/CTs according to the semiquantitative tracer activity analysis. The mean uptake of eight tibial regions of interest was referenced to the mean uptake count on the same region of the contralateral leg to obtain a count ratio. Osteonecrosis was defined as a photopenic area or cold defect. Secondary variables included clinical and radiological follow-up data. Statistics were carried out in a descriptive pattern. Ten patients with a mean age of 59 years and a mean follow up of 18 months were included. Calcium phosphate (CaP) substitute bone cement was used in 60 % and polymethyl methacrylate mixed with hydroxyapatite (PMMA/HA) bone cement in 40 %. Normal to high SPECT/CT activity without photopenic areas were observed in all patients and the mean tracer activity ratio was four, indicating vital bone in all patients. There were no postoperative infections and only one 57 year old patient with hemineglect and CaP cement showed failed osseous consolidation. The mean Tegner and Lysholm as well as the Lysholm scores were three and 80, respectively. This novel study about cement-augmented balloon tibioplasties showed that osseous vitality remains intact according to SPECT/CT analysis; irrespective of the type of cement and even in the presence of thin bone lamellae. This procedure was safe and well-suited for lateral tibial plateau fractures in particular. Surgeons may consider using PMMA/HA bone cement for void filling in elderly fracture patients without concern about bone viability.


  • Pitfalls and Limitations in Simultaneous PET/MRI

    by Gaspar Delso, Edwin ter Voert, Felipe de Galiza Barbosa, Patrick Veit-Haibach


  • Workflow in Simultaneous PET/MRI

    by Felipe de Galiza Barbosa, Gustav von Schulthess, Patrick Veit-Haibach


  • PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    by Marcelo A. Queiroz, Rahel A. Kubik-Huch, Nik Hauser, Bianka Freiwald-Chilla, Gustav von Schulthess, Johannes M. Froehlich, Patrick Veit-Haibach

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. • PET/MRI is superior to PET/CT for primary tumour delineation • PET/CT represents a reliable tool to detect extra-abdominal distant metastasis • PET/MRI might be the preferred imaging modality for staging cervical and endometrial tumours • Whole-body staging for detection and evaluation of extra-abdominal metastases is mandatory


  • Guest Editorial

    by Gustav K. Von Schulthess, Patrick Veit-Haibach