Anna M. Sailer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anna M. Sailer has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Joachim Ernst Wildberger
Department of Radiology & Nuclear Medicine, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands
4 shared publications - Wim van Zwam
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands
4 shared publications - Cecile R. L. P. N. Jeukens
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
3 shared publications - Geert Willem H. Schurink
Department of Vascular Surgery, CARIM School for Cardiovascular Diseases, Heart and Vascular Center, Maastricht University Medical Center (MUMC+), 6229 ER Maastricht, The Netherlands
3 shared publications - Michiel W. de Haan
Department of Radiology, Maastricht University Medical Center, Maastricht, The Netherlands
3 shared publications - Rick de Graaf
Department of Radiology, Maastricht University Medical Centre, Maastricht - The Netherlands
3 shared publications
Latest Publications
- Open Access
- 12 May 2017
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (11) , 1756-1762
Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring
Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm2 versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm2, p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.
- 12 May 2017
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (11) , 1756-1762
Open AccessPersonalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring
Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm2 versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm2, p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.
- Open Access
- 24 May 2015
- Published by Springer Nature in European Radiology
- Vol. 25 (12) , 3629-3637
Cost-effectiveness modelling in diagnostic imaging: a stepwise approach
Diagnostic imaging (DI) is the fastest growing sector in medical expenditures and takes a central role in medical decision-making. The increasing number of
- 24 May 2015
- Published by Springer Nature in European Radiology
- Vol. 25 (12) , 3629-3637
Open AccessCost-effectiveness modelling in diagnostic imaging: a stepwise approach
Diagnostic imaging (DI) is the fastest growing sector in medical expenditures and takes a central role in medical decision-making. The increasing number of
- Open Access
- 14 March 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (5) , 1198-1204
Iliocaval Confluence Stenting for Chronic Venous Obstructions
Purpose Different techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions. Materials and Methods Between 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) or high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents. Results Recanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days. Conclusion Stenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.
- 14 March 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (5) , 1198-1204
Open AccessIliocaval Confluence Stenting for Chronic Venous Obstructions
Purpose Different techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions. Materials and Methods Between 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) or high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents. Results Recanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days. Conclusion Stenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.
- 5 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (4) , 827-832
Occupational Radiation Exposure During Endovascular Aortic Repair
The aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair. Occupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding was used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented. Average procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049). Average FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.
- 5 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (4) , 827-832
Occupational Radiation Exposure During Endovascular Aortic Repair
The aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair. Occupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding was used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented. Average procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049). Average FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.
- 30 July 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 314-321
Fusion Guidance in Endovascular Peripheral Artery Interventions: A Feasibility Study
This study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA). Fusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusion road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography. Average time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation). Fluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety.
- 30 July 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 314-321
Fusion Guidance in Endovascular Peripheral Artery Interventions: A Feasibility Study
This study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA). Fusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusion road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography. Average time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation). Fluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety.
- 6 May 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (1) , 112-120
Radiation Exposure of Abdominal Cone Beam Computed Tomography
To evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT). This prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed. Mean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight. Mean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.
- 6 May 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (1) , 112-120
Radiation Exposure of Abdominal Cone Beam Computed Tomography
To evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT). This prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed. Mean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight. Mean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.
- Open Access
- 22 April 2014
- Published by Springer Nature in Cancer Imaging
- Vol. 14 (1) , 12
RECIST measurements in cancer treatment: is there a role for physician assistants? - A pilot study
Decision making in cancer treatment is influenced by standardized RECIST measurements which are subjective to interobserver variability. Aim of this pilot study was to evaluate whether it is feasible to transfer the radiologist's task of RECIST measurements to a trained radiology physician assistant and whether this influences diagnostic performance.177 lesions in twenty patients were measured on baseline and two follow-up CTs using RECIST 1.1: Arm A according to routine clinical practice where various radiologists read scans of the referred patients. Arm B according to the experimental setting where a radiology physician assistant performed RECIST measurements of target lesions defined by the radiologists on baseline scans. Performance and agreement were compared between groups.Standard deviation between lesion measurements of arm A and B was four millimeters. Interobserver agreement comparing response category classification was substantial, ĸ = 0.77 (95% CI: 0.66 - 0.87). Sensitivity and specificity for the radiology physician assistant for assessing progressive disease were 100% (95% CI: 61% - 100%) and 94% (95% CI: 81% - 98%) respectively.RECIST measurements performed by a paramedic are a feasible alternative to standard practice. This could impact the workflow of radiological units, opening ways to re-assigning radiologists' important, standardized but time consuming tasks to paramedics.
- 22 April 2014
- Published by Springer Nature in Cancer Imaging
- Vol. 14 (1) , 12
Open AccessRECIST measurements in cancer treatment: is there a role for physician assistants? - A pilot study
Decision making in cancer treatment is influenced by standardized RECIST measurements which are subjective to interobserver variability. Aim of this pilot study was to evaluate whether it is feasible to transfer the radiologist's task of RECIST measurements to a trained radiology physician assistant and whether this influences diagnostic performance.177 lesions in twenty patients were measured on baseline and two follow-up CTs using RECIST 1.1: Arm A according to routine clinical practice where various radiologists read scans of the referred patients. Arm B according to the experimental setting where a radiology physician assistant performed RECIST measurements of target lesions defined by the radiologists on baseline scans. Performance and agreement were compared between groups.Standard deviation between lesion measurements of arm A and B was four millimeters. Interobserver agreement comparing response category classification was substantial, ĸ = 0.77 (95% CI: 0.66 - 0.87). Sensitivity and specificity for the radiology physician assistant for assessing progressive disease were 100% (95% CI: 61% - 100%) and 94% (95% CI: 81% - 98%) respectively.RECIST measurements performed by a paramedic are a feasible alternative to standard practice. This could impact the workflow of radiological units, opening ways to re-assigning radiologists' important, standardized but time consuming tasks to paramedics.
- 1 April 2014
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 47 (4) , 349-356
CTA with Fluoroscopy Image Fusion Guidance in Endovascular Complex Aortic Aneurysm Repair
- 1 April 2014
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 47 (4) , 349-356
CTA with Fluoroscopy Image Fusion Guidance in Endovascular Complex Aortic Aneurysm Repair
- Open Access
- 10 July 2013
- Published by Springer Nature in Insights into Imaging
- Vol. 4 (4) , 499-507
Cost-effectiveness of CTA, MRA and DSA in patients with non-traumatic subarachnoid haemorrhage
Objectives Intra-arterial digital subtraction angiography (DSA), magnetic resonance angiography (MRA) and computed tomographic angiography (CTA) are imaging modalities used for diagnostic work-up of non-traumatic subarachnoid haemorrhage. The aim of our study was to compare the cost-effectiveness of MRA, DSA and CTA in the first year after the bleed. Methods A decision model was used to calculate costs and benefits (in quality-adjusted life-years [QALYs]) that accrued to cohorts of 1,000 patients. Costs and characteristics of diagnostic tests, therapy, patients’ quality of life and associated costs were respected. The diagnostic strategy with highest QALYs and lowest costs was considered most cost-effective. Results DSA was the most effective diagnostic option, yielding on average 0.6039 QALYs (95 % CI, 0.5761–0.6327) per patient, followed by CTA 0.5983 QALYs (95 % CI, 0.5704–0.6278) and MRA 0.5947 QALYs (95 % CI, 0.5674–0.6237). Cost was lowest for DSA (39,808 €; 95 % CI, 37,182–42,663), followed by CTA (40,748 €; 95 % CI, 37,937–43,831) and MRA (41,814 €; 95 % CI, 38,730–45,146). A strategy of CTA followed by DSA if CTA was negative or coiling deemed not feasible, was as effective as DSA alone at average costs of 39,767€ (95 % CI, 36,903–42,402). Conclusion A combined strategy of CTA and DSA was found to be the most cost-effective diagnostic approach. Main Messages • We defined a standard model for cost-effectiveness analysis in diagnostic imaging. • Comparing total 1-year health costs and benefits, CTA is superior to MRA. • A strategy of combining CTA and DSA was found to be the most cost-effective diagnostic approach.
- 10 July 2013
- Published by Springer Nature in Insights into Imaging
- Vol. 4 (4) , 499-507
Open AccessCost-effectiveness of CTA, MRA and DSA in patients with non-traumatic subarachnoid haemorrhage
Objectives Intra-arterial digital subtraction angiography (DSA), magnetic resonance angiography (MRA) and computed tomographic angiography (CTA) are imaging modalities used for diagnostic work-up of non-traumatic subarachnoid haemorrhage. The aim of our study was to compare the cost-effectiveness of MRA, DSA and CTA in the first year after the bleed. Methods A decision model was used to calculate costs and benefits (in quality-adjusted life-years [QALYs]) that accrued to cohorts of 1,000 patients. Costs and characteristics of diagnostic tests, therapy, patients’ quality of life and associated costs were respected. The diagnostic strategy with highest QALYs and lowest costs was considered most cost-effective. Results DSA was the most effective diagnostic option, yielding on average 0.6039 QALYs (95 % CI, 0.5761–0.6327) per patient, followed by CTA 0.5983 QALYs (95 % CI, 0.5704–0.6278) and MRA 0.5947 QALYs (95 % CI, 0.5674–0.6237). Cost was lowest for DSA (39,808 €; 95 % CI, 37,182–42,663), followed by CTA (40,748 €; 95 % CI, 37,937–43,831) and MRA (41,814 €; 95 % CI, 38,730–45,146). A strategy of CTA followed by DSA if CTA was negative or coiling deemed not feasible, was as effective as DSA alone at average costs of 39,767€ (95 % CI, 36,903–42,402). Conclusion A combined strategy of CTA and DSA was found to be the most cost-effective diagnostic approach. Main Messages • We defined a standard model for cost-effectiveness analysis in diagnostic imaging. • Comparing total 1-year health costs and benefits, CTA is superior to MRA. • A strategy of combining CTA and DSA was found to be the most cost-effective diagnostic approach.