J. Bomer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J. Bomer has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
H. C. Holscher
Haga Teaching Hospital/Juliana Children’s Hospital
2 shared publicationsF. Klerx-Melis
Haga Teaching Hospital/Juliana Children’s Hospital
1 shared publicationL. Wiersma-Deijl
Radiology Department, Haga Teaching Hospital/Juliana Children’s Hospital, Den Haag, The Netherlands
1 shared publication
Latest Publications
- 8 October 2013
- Published by Springer Nature in European Radiology
- Vol. 24 (3) , 703-708
Painful paediatric hip: frog-leg lateral view only!
For hip complaints in the paediatric population, it is common practice to acquire both anteroposterior (AP) and frog-leg lateral (FL) radiographs. This combination of views provides a high diagnostic yield, but also doubles radiation exposure. We investigated the diagnostic accuracy of obtaining a solitary FL view as compared to a combination of the AP and FL view. Hip radiographs of 524 children (aged 2–15 years) referred for acute hip pain were retrospectively assessed by two independent radiologists. Cases of trauma, neuromuscular disorders or a history of known hip disease were excluded. Radiologists were blinded to the AP radiograph while assessing the solitary FL radiograph. We used Cohen’s kappa test to calculate agreement between the assessment of both views and the solitary FL view. Agreement between the assessment of the solitary FL view and the combination of the AP and FL view was very high with a kappa value of 0.989. The diagnostic accuracy of the FL radiograph in cases of hip complaints in children is as high as the current standard employing both AP and FL views. Therefore a solitary FL radiograph appears sufficient. This practice would substantially reduce radiation exposure. • Radiation exposure in children should be kept to a minimum. • In paediatric hip radiography a solitary frog-leg lateral view suffices. • This reduces radiation exposure and costs of imaging.
- 8 October 2013
- Published by Springer Nature in European Radiology
- Vol. 24 (3) , 703-708
Painful paediatric hip: frog-leg lateral view only!
For hip complaints in the paediatric population, it is common practice to acquire both anteroposterior (AP) and frog-leg lateral (FL) radiographs. This combination of views provides a high diagnostic yield, but also doubles radiation exposure. We investigated the diagnostic accuracy of obtaining a solitary FL view as compared to a combination of the AP and FL view. Hip radiographs of 524 children (aged 2–15 years) referred for acute hip pain were retrospectively assessed by two independent radiologists. Cases of trauma, neuromuscular disorders or a history of known hip disease were excluded. Radiologists were blinded to the AP radiograph while assessing the solitary FL radiograph. We used Cohen’s kappa test to calculate agreement between the assessment of both views and the solitary FL view. Agreement between the assessment of the solitary FL view and the combination of the AP and FL view was very high with a kappa value of 0.989. The diagnostic accuracy of the FL radiograph in cases of hip complaints in children is as high as the current standard employing both AP and FL views. Therefore a solitary FL radiograph appears sufficient. This practice would substantially reduce radiation exposure. • Radiation exposure in children should be kept to a minimum. • In paediatric hip radiography a solitary frog-leg lateral view suffices. • This reduces radiation exposure and costs of imaging.
- Open Access
- 28 August 2013
- Published by Springer Nature in Insights into Imaging
- Vol. 4 (5) , 723-727
Electronic collimation and radiation protection in paediatric digital radiography: revival of the silver lining
In digital radiography we are now able to electronically collimate images after acquisition. This may seem convenient in paediatric imaging, but we have to be aware that electronic collimation has two major downsides. Electronic collimation implicates that the original field size should have been smaller and the child has been exposed to unnecessary radiation. Also, by use of electronic collimation, potentially important information may be lost. The “silver lining”, denoting the X-ray beam collimation, can serve as a useful radiation protection instrument to check for proper field size and detect unnecessary exposure. Furthermore, the silver lining confirms all exposed anatomy is shown in the final image, and thus may also serve as a quality assurance instrument as the patient has the right to all acquired information. Teaching Points • The ability to electronically collimate an image after acquisition may serve to enhance contrast in the region of interest. • The ability to electronically collimate an image after acquisition carries the risk of overexposure. • The ability to electronically collimate an image after acquisition carries the risk of losing important information. • The silver lining can serve as a quality control instrument for proper collimation. • The patient has the right to all information obtained during an X-ray examination.
- 28 August 2013
- Published by Springer Nature in Insights into Imaging
- Vol. 4 (5) , 723-727
Open AccessElectronic collimation and radiation protection in paediatric digital radiography: revival of the silver lining
In digital radiography we are now able to electronically collimate images after acquisition. This may seem convenient in paediatric imaging, but we have to be aware that electronic collimation has two major downsides. Electronic collimation implicates that the original field size should have been smaller and the child has been exposed to unnecessary radiation. Also, by use of electronic collimation, potentially important information may be lost. The “silver lining”, denoting the X-ray beam collimation, can serve as a useful radiation protection instrument to check for proper field size and detect unnecessary exposure. Furthermore, the silver lining confirms all exposed anatomy is shown in the final image, and thus may also serve as a quality assurance instrument as the patient has the right to all acquired information. Teaching Points • The ability to electronically collimate an image after acquisition may serve to enhance contrast in the region of interest. • The ability to electronically collimate an image after acquisition carries the risk of overexposure. • The ability to electronically collimate an image after acquisition carries the risk of losing important information. • The silver lining can serve as a quality control instrument for proper collimation. • The patient has the right to all information obtained during an X-ray examination.