Alexandre A. Shvartsburg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexandre A. Shvartsburg has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Richard Smith
Pacific Northwest National Laboratory
8 shared publications Giorgis Isaac
Biological Sciences Division, Pacific Northwest National Laboratory, 99352, Richland, WA, USA
2 shared publicationsNathalie Leveque
LETIAM Universite Paris-Sud XI, Orsay, France
2 shared publications- Randy Purves
University of Saskatchewan
2 shared publications Thomas O. Metz
Biological Sciences Division, Pacific Northwest National Laboratory, 99352, Richland, WA, USA
2 shared publicationsDavid Singer
Institute of Bioanalytical Chemistry & Center for Biotechnology and Biomedicine, Universität Leipzig, 04103 Leipzig, Germany
1 shared publication
Latest Publications
- 20 December 2012
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 24 (1) , 109-114
High-Definition Differential Ion Mobility Spectrometry with Resolving Power up to 500
As the resolution of analytical methods improves, further progress tends to be increasingly limited by instrumental parameter instabilities that were previously inconsequential. This is now the cas...
- 20 December 2012
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 24 (1) , 109-114
High-Definition Differential Ion Mobility Spectrometry with Resolving Power up to 500
As the resolution of analytical methods improves, further progress tends to be increasingly limited by instrumental parameter instabilities that were previously inconsequential. This is now the cas...
- 3 May 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (10) , 4271-4276
Ion Mobility Separation of Variant Histone Tails Extending to the “Middle-Down” Range
Differential ion mobility spectrometry (FAIMS) can baseline-resolve multiple variants of post-translationally modified peptides extending to the 3–4 kDa range, which differ in the localization of a PTM as small as acetylation. Essentially orthogonal separations for different charge states expand the total peak capacity with the number of observed states that increases for longer polypeptides. This potentially enables resolving localization variants for yet larger peptides and even intact proteins.
- 3 May 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (10) , 4271-4276
Ion Mobility Separation of Variant Histone Tails Extending to the “Middle-Down” Range
Differential ion mobility spectrometry (FAIMS) can baseline-resolve multiple variants of post-translationally modified peptides extending to the 3–4 kDa range, which differ in the localization of a PTM as small as acetylation. Essentially orthogonal separations for different charge states expand the total peak capacity with the number of observed states that increases for longer polypeptides. This potentially enables resolving localization variants for yet larger peptides and even intact proteins.
- 10 November 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (23) , 9159-9166
Accelerated High-Resolution Differential Ion Mobility Separations Using Hydrogen
The resolving power of differential ion mobility spectrometry (FAIMS) was dramatically increased recently by carrier gases comprising up to 75% He or various vapors, enabling many new applications. However, the need for resolution of complex mixtures is virtually open-ended and many topical analyses demand yet finer separations. Also, the resolving power gains are often at the expense of speed, in particular making high-resolution FAIMS poorly compatible with online liquid-phase separations. Here, we report FAIMS employing hydrogen, specifically in mixtures with N2 containing up to 90% H2. Such compositions raise the mobilities of all ions and thus the resolving power beyond that previously feasible, while avoiding the electrical breakdown inevitable in He-rich mixtures. The increases in resolving power and ensuing peak resolution are especially significant at H2 fractions above ∼50%. Higher resolution can be exchanged for acceleration of the analyses by up to ∼4 times. For more mobile species such as multiply charged peptides, this exchange is presently forced by the constraints of existing FAIMS devices, but future designs optimized for H2 should consistently improve resolution for all analytes.
- 10 November 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (23) , 9159-9166
Accelerated High-Resolution Differential Ion Mobility Separations Using Hydrogen
The resolving power of differential ion mobility spectrometry (FAIMS) was dramatically increased recently by carrier gases comprising up to 75% He or various vapors, enabling many new applications. However, the need for resolution of complex mixtures is virtually open-ended and many topical analyses demand yet finer separations. Also, the resolving power gains are often at the expense of speed, in particular making high-resolution FAIMS poorly compatible with online liquid-phase separations. Here, we report FAIMS employing hydrogen, specifically in mixtures with N2 containing up to 90% H2. Such compositions raise the mobilities of all ions and thus the resolving power beyond that previously feasible, while avoiding the electrical breakdown inevitable in He-rich mixtures. The increases in resolving power and ensuing peak resolution are especially significant at H2 fractions above ∼50%. Higher resolution can be exchanged for acceleration of the analyses by up to ∼4 times. For more mobile species such as multiply charged peptides, this exchange is presently forced by the constraints of existing FAIMS devices, but future designs optimized for H2 should consistently improve resolution for all analytes.
- 13 June 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (13) , 5078-5085
Ion Mobility Separation of Isomeric Phosphopeptides from a Protein with Variant Modification of Adjacent Residues
Ion mobility spectrometry (IMS), and particularly differential or field asymmetric waveform IMS (FAIMS), was recently shown capable of separating peptides with variant localization of post-translational modifications. However, that work was limited to a model peptide with Ser phosphorylation on fairly distant alternative sites. Here, we demonstrate that FAIMS (coupled to electrospray/mass spectrometry (ESI/MS)) can broadly baseline-resolve variant phosphopeptides from a biologically modified human protein, including those involving phosphorylation of different residues and adjacent sites that challenge existing tandem mass spectrometry (MS/MS) methods most. Singly and doubly phosphorylated variants can be resolved equally well and identified without dissociation, based on accurate separation properties. The spectra change little over a range of infusion solvent pH; hence, the present approach should be viable in conjunction with chromatographic separations using mobile phase gradients.
- 13 June 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (13) , 5078-5085
Ion Mobility Separation of Isomeric Phosphopeptides from a Protein with Variant Modification of Adjacent Residues
Ion mobility spectrometry (IMS), and particularly differential or field asymmetric waveform IMS (FAIMS), was recently shown capable of separating peptides with variant localization of post-translational modifications. However, that work was limited to a model peptide with Ser phosphorylation on fairly distant alternative sites. Here, we demonstrate that FAIMS (coupled to electrospray/mass spectrometry (ESI/MS)) can broadly baseline-resolve variant phosphopeptides from a biologically modified human protein, including those involving phosphorylation of different residues and adjacent sites that challenge existing tandem mass spectrometry (MS/MS) methods most. Singly and doubly phosphorylated variants can be resolved equally well and identified without dissociation, based on accurate separation properties. The spectra change little over a range of infusion solvent pH; hence, the present approach should be viable in conjunction with chromatographic separations using mobile phase gradients.
- Open Access
- 10 May 2011
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 22 (7) , 1156
Erratum to: Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry
- 10 May 2011
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 22 (7) , 1156
Open AccessErratum to: Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry
- 12 April 2011
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 22 (7) , 1146-1155
Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry
Correlations between the dimensions of a 2-D separation create trend lines that depend on structural or chemical characteristics of the compound class and thus facilitate classification of unknowns...
- 12 April 2011
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 22 (7) , 1146-1155
Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry
Correlations between the dimensions of a 2-D separation create trend lines that depend on structural or chemical characteristics of the compound class and thus facilitate classification of unknowns...
- 21 April 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 106 (16) , 6495-6500
Pendular proteins in gases and new avenues for characterization of macromolecules by ion mobility spectrometry
Polar molecules align in electric fields when the dipole energy (proportional to field intensity E x dipole moment p) exceeds the thermal rotational energy. Small molecules have low p and align only at inordinately high E or upon extreme cooling. Many biomacromolecules and ions are strong permanent dipoles that align at E achievable in gases and room temperature. The collision cross-sections of aligned ions with gas molecules generally differ from orientationally averaged quantities, affecting ion mobilities measured in ion mobility spectrometry (IMS). Field asymmetric waveform IMS (FAIMS) separates ions by the difference between mobilities at high and low E and hence can resolve and identify macroion conformers based on the mobility difference between pendular and free rotor states. The exceptional sensitivity of that difference to ion geometry and charge distribution holds the potential for a powerful method for separation and characterization of macromolecular species. Theory predicts that the pendular alignment of ions in gases at any E requires a minimum p that depends on the ion mobility, gas pressure, and temperature. At ambient conditions used in current FAIMS systems, p for realistic ions must exceed approximate to 300-400 Debye. The dipole moments of proteins statistically increase with increasing mass, and such values are typical above approximate to 30 kDa. As expected for the dipole-aligned regime, FAIMS analyses of protein ions and complexes of approximate to 30-130 kDa show an order-of-magnitude expansion of separation space compared with smaller proteins and other ions.
- 21 April 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 106 (16) , 6495-6500
Pendular proteins in gases and new avenues for characterization of macromolecules by ion mobility spectrometry
Polar molecules align in electric fields when the dipole energy (proportional to field intensity E x dipole moment p) exceeds the thermal rotational energy. Small molecules have low p and align only at inordinately high E or upon extreme cooling. Many biomacromolecules and ions are strong permanent dipoles that align at E achievable in gases and room temperature. The collision cross-sections of aligned ions with gas molecules generally differ from orientationally averaged quantities, affecting ion mobilities measured in ion mobility spectrometry (IMS). Field asymmetric waveform IMS (FAIMS) separates ions by the difference between mobilities at high and low E and hence can resolve and identify macroion conformers based on the mobility difference between pendular and free rotor states. The exceptional sensitivity of that difference to ion geometry and charge distribution holds the potential for a powerful method for separation and characterization of macromolecular species. Theory predicts that the pendular alignment of ions in gases at any E requires a minimum p that depends on the ion mobility, gas pressure, and temperature. At ambient conditions used in current FAIMS systems, p for realistic ions must exceed approximate to 300-400 Debye. The dipole moments of proteins statistically increase with increasing mass, and such values are typical above approximate to 30 kDa. As expected for the dipole-aligned regime, FAIMS analyses of protein ions and complexes of approximate to 30-130 kDa show an order-of-magnitude expansion of separation space compared with smaller proteins and other ions.
- 6 October 2006
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 110 (43) , 21966-21980
Field Asymmetric Waveform Ion Mobility Spectrometry Studies of Proteins: Dipole Alignment in Ion Mobility Spectrometry?
Approaches to separation and characterization of ions based on their mobilities in gases date back to the 1960s. Conventional ion mobility spectrometry (IMS) measures the absolute mobility, and field asymmetric waveform IMS (FAIMS) exploits the difference between mobilities at high and low electric fields. However, in all previous IMS and FAIMS experiments ions experienced an essentially free rotation; thus the separation was based on the orientationally averaged cross-sections Ωavg between ions and buffer gas molecules. Virtually all large ions are permanent electric dipoles that will be oriented by a sufficiently strong electric field. Under typical FAIMS conditions this will occur for dipole moments >400 D, found for many macroions including most proteins above ∼30 kDa. Mobilities of aligned dipoles depend on directional cross-sections Ωdir (rather than Ωavg), which should have a major effect on FAIMS separation parameters. Here we report the FAIMS behavior of electrospray-ionization-generated ions for 10 proteins up to ∼70 kDa. Those above 29 kDa exhibit a strong increase of mobility at high field, which is consistent with predicted ion dipole alignment. This effect expands the useful FAIMS separation power by an order of magnitude, allowing separation of up to ∼102 distinct protein conformers and potentially revealing information about Ωdir and ion dipole moment that is of utility for structural characterization. Possible approaches to extending dipole alignment to smaller ions are discussed.
- 6 October 2006
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 110 (43) , 21966-21980
Field Asymmetric Waveform Ion Mobility Spectrometry Studies of Proteins: Dipole Alignment in Ion Mobility Spectrometry?
Approaches to separation and characterization of ions based on their mobilities in gases date back to the 1960s. Conventional ion mobility spectrometry (IMS) measures the absolute mobility, and field asymmetric waveform IMS (FAIMS) exploits the difference between mobilities at high and low electric fields. However, in all previous IMS and FAIMS experiments ions experienced an essentially free rotation; thus the separation was based on the orientationally averaged cross-sections Ωavg between ions and buffer gas molecules. Virtually all large ions are permanent electric dipoles that will be oriented by a sufficiently strong electric field. Under typical FAIMS conditions this will occur for dipole moments >400 D, found for many macroions including most proteins above ∼30 kDa. Mobilities of aligned dipoles depend on directional cross-sections Ωdir (rather than Ωavg), which should have a major effect on FAIMS separation parameters. Here we report the FAIMS behavior of electrospray-ionization-generated ions for 10 proteins up to ∼70 kDa. Those above 29 kDa exhibit a strong increase of mobility at high field, which is consistent with predicted ion dipole alignment. This effect expands the useful FAIMS separation power by an order of magnitude, allowing separation of up to ∼102 distinct protein conformers and potentially revealing information about Ωdir and ion dipole moment that is of utility for structural characterization. Possible approaches to extending dipole alignment to smaller ions are discussed.
- 7 February 2006
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 110 (8) , 2663-2673
Feasibility of Higher-Order Differential Ion Mobility Separations Using New Asymmetric Waveforms
Technologies for separating and characterizing ions based on their transport properties in gases have been around for three decades. The early method of ion mobility spectrometry (IMS) distinguished ions by absolute mobility that depends on the collision cross section with buffer gas atoms. The more recent technique of field asymmetric waveform IMS (FAIMS) measures the difference between mobilities at high and low electric fields. Coupling IMS and FAIMS to soft ionization sources and mass spectrometry (MS) has greatly expanded their utility, enabling new applications in biomedical and nanomaterials research. Here, we show that time-dependent electric fields comprising more than two intensity levels could, in principle, effect an infinite number of distinct differential separations based on the higher-order terms of expression for ion mobility. These analyses could employ the hardware and operational procedures similar to those utilized in FAIMS. Methods up to the 4th or 5th order (where conventional IMS is 1st order and FAIMS is 2nd order) should be practical at field intensities accessible in ambient air, with still higher orders potentially achievable in insulating gases. Available experimental data suggest that higher-order separations should be largely orthogonal to each other and to FAIMS, IMS, and MS.
- 7 February 2006
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 110 (8) , 2663-2673
Feasibility of Higher-Order Differential Ion Mobility Separations Using New Asymmetric Waveforms
Technologies for separating and characterizing ions based on their transport properties in gases have been around for three decades. The early method of ion mobility spectrometry (IMS) distinguished ions by absolute mobility that depends on the collision cross section with buffer gas atoms. The more recent technique of field asymmetric waveform IMS (FAIMS) measures the difference between mobilities at high and low electric fields. Coupling IMS and FAIMS to soft ionization sources and mass spectrometry (MS) has greatly expanded their utility, enabling new applications in biomedical and nanomaterials research. Here, we show that time-dependent electric fields comprising more than two intensity levels could, in principle, effect an infinite number of distinct differential separations based on the higher-order terms of expression for ion mobility. These analyses could employ the hardware and operational procedures similar to those utilized in FAIMS. Methods up to the 4th or 5th order (where conventional IMS is 1st order and FAIMS is 2nd order) should be practical at field intensities accessible in ambient air, with still higher orders potentially achievable in insulating gases. Available experimental data suggest that higher-order separations should be largely orthogonal to each other and to FAIMS, IMS, and MS.
- Open Access
- 1 March 2004
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 15 (3) , 406-408
Attachment of metal trications to peptides
- 1 March 2004
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 15 (3) , 406-408
Open AccessAttachment of metal trications to peptides