Sebastian Leschka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Leschka has a total of 153 co-authors. Here are the top co-authors by number of shared publications:
- Simon Wildermuth
Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen, St. Gallen, Switzerland
13 shared publications - Stephan Waelti
Department of Radiology and Nuclear Medicine, Children’s Hospital of Eastern Switzerland, St. Gallen, Switzerland
10 shared publications - Tobias Johannes Dietrich
Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen, St. Gallen, Switzerland
9 shared publications - Tim Fischer
Clinic for Radiology and Nuclear Medicine, Cantonal Hospital Winterthur, Winterthur, Switzerland
8 shared publications Hatem Alkadhi
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
7 shared publications- Hatem Alkadhi
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
6 shared publications
Latest Publications
- 23 February 2026
- Published by Springer Nature in Skeletal Radiology
- Vol. 55 (7) , 1555-1564
Tin-filtered ultra-low-dose CT for lower limb torsion measurements in children and adolescents: a prospective study
Objective Accurate femoral and tibial torsion measurements are essential for planning lower extremity derotation surgeries in children/adolescents. Advances in modern CT scanners may enable reliable measurements using tin filtration in addition to an ultra-low-dose CT protocol, markedly reducing radiation exposure. This study evaluates image quality, reliability, and estimated effective radiation dose of this approach. Materials and methods Between April 2022 and December 2022, tin-filtered ultra-low-dose CTs were prospectively acquired from 52 children/adolescents using a 384-slice scanner. Two pediatric radiologists independently performed torsion measurements for all patients. Interrater agreement and image quality were assessed. Effective radiation doses of the scans were estimated. Results The study population consisted of 52 participants (mean age, 12.7 years ± 2.0 [standard deviation]; 19 females, 33 males). All torsion measurements showed very high interrater agreement (intra-class correlation coefficient > 90% for all locations). The image quality of the vast majority of image datasets was rated as excellent. The mean total effective dose of the tin filtered ultra-low-dose protocol (including 3 spiral scans) was 0.026/0.025 mSv (boys/girls), compared to 0.184/0.215 mSv (boys/girls) of the previously published ultra-low-dose protocol without tin filtration. This represents a dose reduction of up to 88% compared to the previous protocol. Conclusion The use of tin filtration, in addition to an ultra-low-dose protocol, allows pediatric lower extremity torsion measurements to be performed with radiation doses in a lower range than a typical localizer dose, without compromising diagnostic confidence, pushing the limits of the ALARA (as low as reasonably achievable) principle.
- 23 February 2026
- Published by Springer Nature in Skeletal Radiology
- Vol. 55 (7) , 1555-1564
Tin-filtered ultra-low-dose CT for lower limb torsion measurements in children and adolescents: a prospective study
Objective Accurate femoral and tibial torsion measurements are essential for planning lower extremity derotation surgeries in children/adolescents. Advances in modern CT scanners may enable reliable measurements using tin filtration in addition to an ultra-low-dose CT protocol, markedly reducing radiation exposure. This study evaluates image quality, reliability, and estimated effective radiation dose of this approach. Materials and methods Between April 2022 and December 2022, tin-filtered ultra-low-dose CTs were prospectively acquired from 52 children/adolescents using a 384-slice scanner. Two pediatric radiologists independently performed torsion measurements for all patients. Interrater agreement and image quality were assessed. Effective radiation doses of the scans were estimated. Results The study population consisted of 52 participants (mean age, 12.7 years ± 2.0 [standard deviation]; 19 females, 33 males). All torsion measurements showed very high interrater agreement (intra-class correlation coefficient > 90% for all locations). The image quality of the vast majority of image datasets was rated as excellent. The mean total effective dose of the tin filtered ultra-low-dose protocol (including 3 spiral scans) was 0.026/0.025 mSv (boys/girls), compared to 0.184/0.215 mSv (boys/girls) of the previously published ultra-low-dose protocol without tin filtration. This represents a dose reduction of up to 88% compared to the previous protocol. Conclusion The use of tin filtration, in addition to an ultra-low-dose protocol, allows pediatric lower extremity torsion measurements to be performed with radiation doses in a lower range than a typical localizer dose, without compromising diagnostic confidence, pushing the limits of the ALARA (as low as reasonably achievable) principle.
- 30 July 2025
- Published by Elsevier in Radiography
- Vol. 31 (5) , 103106
Ossification variation of the medial clavicular epiphysis in children, adolescents and young adults
- 30 July 2025
- Published by Elsevier in Radiography
- Vol. 31 (5) , 103106
Ossification variation of the medial clavicular epiphysis in children, adolescents and young adults
- 16 November 2024
- Published by Springer Nature
- p. 49-59
Erkennung und Vermeidung von Artefakten
- 16 November 2024
- Published by Springer Nature
- p. 211-221
CT bei Kindern
- Open Access
- 1 June 2023
- Published by Springer Nature in Skeletal Radiology
- Vol. 53 (1) , 43-49
Age-related prevalence and imaging characteristics of the superior acetabular roof notch in children, adolescents, and young adults
Objective: To determine the age-related prevalence and imaging characteristics of the superior acetabular roof notch (SARN) on hip MRI and radiographs in a young study population. Materials and methods: Retrospective analysis of 304 MRI examinations and corresponding available radiographs of patients between the ages of 4 and 24 years. Two observers classified SARN with fluid-like findings on MRI as type-1, whereas SARN with fat-like findings on MRI were classified as type-2. Sensitivity and specificity of radiographic SARN findings were determined using MRI as the reference standard. Logistic regression models were used to assess the age-related prevalence on MRI. Results: Twelve patients (3.9%) had fluid-like SARN type-1, 27 patients (8.9%) had fat-like SARN type-2, while 265 patients (87.2%) had no SARN on MRI. The odds ratio (OR) for age (years) with respect to the presence of a fluid-like SARN type-1 on MRI was 0.79 (95% CI: 0.70–0.89), meaning that with each year, the likelihood for SARN type-1 decreased by 21% (p < 0.001). The OR for age with respect to the presence of a fat-like SARN type-2 on MRI was 1.14 (95% CI: 1.02–1.27) (p = 0.017). The diagnostic sensitivity for detecting a SARN on radiographs compared to MRI as the reference standard was between 0.75 and 0.83 and the corresponding specificity was between 0.85 and 0.89 for both observers. Conclusion: SARN is a common finding on MRI and radiographs. The present data suggest that SARN undergoes an age-related imaging characteristic from a fluid-like appearance to a fat-like appearance on MRI during adolescence.
- 1 June 2023
- Published by Springer Nature in Skeletal Radiology
- Vol. 53 (1) , 43-49
Open AccessAge-related prevalence and imaging characteristics of the superior acetabular roof notch in children, adolescents, and young adults
Objective: To determine the age-related prevalence and imaging characteristics of the superior acetabular roof notch (SARN) on hip MRI and radiographs in a young study population. Materials and methods: Retrospective analysis of 304 MRI examinations and corresponding available radiographs of patients between the ages of 4 and 24 years. Two observers classified SARN with fluid-like findings on MRI as type-1, whereas SARN with fat-like findings on MRI were classified as type-2. Sensitivity and specificity of radiographic SARN findings were determined using MRI as the reference standard. Logistic regression models were used to assess the age-related prevalence on MRI. Results: Twelve patients (3.9%) had fluid-like SARN type-1, 27 patients (8.9%) had fat-like SARN type-2, while 265 patients (87.2%) had no SARN on MRI. The odds ratio (OR) for age (years) with respect to the presence of a fluid-like SARN type-1 on MRI was 0.79 (95% CI: 0.70–0.89), meaning that with each year, the likelihood for SARN type-1 decreased by 21% (p < 0.001). The OR for age with respect to the presence of a fat-like SARN type-2 on MRI was 1.14 (95% CI: 1.02–1.27) (p = 0.017). The diagnostic sensitivity for detecting a SARN on radiographs compared to MRI as the reference standard was between 0.75 and 0.83 and the corresponding specificity was between 0.85 and 0.89 for both observers. Conclusion: SARN is a common finding on MRI and radiographs. The present data suggest that SARN undergoes an age-related imaging characteristic from a fluid-like appearance to a fat-like appearance on MRI during adolescence.
- Open Access
- 21 April 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (8) , 3016
Prospective Evaluation of Magnetic Resonance Imaging Features of Magnesium-Based Alloy Screw Resorption in Pediatric Fractures
Background: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. Objective: The evaluation of magnetic resonance imaging (MRI) findings during the most active phase of screw resorption is the objective, with particular focus on the growth plate and to assess for the presence of metal-induced artifacts. Material and Methods: In total, 30 prospectively acquired MRIs from 17 pediatric patients with fractures treated with magnesium screws were assessed for the presence and distribution of intraosseous, extraosseous, and intra-articular gas; gas within the growth plate; osteolysis along the screw; joint effusion; bone marrow edema; periosteal reaction; soft tissue edema; and metal-induced artifacts. Results: Gas locules were found in the bone and soft tissues in 100% of the examinations, intra-articular in 40%, and in 37% of unfused growth plates. Osteolysis and the periosteal reaction were present in 87%, bone marrow edema in 100%, soft tissue edema in 100%, and joint effusion in 50% of examinations. Pile-up artifacts were present in 100%, and geometric distortion in 0% of examinations. Fat suppression was not significantly impaired in any examination. Conclusions: Gas and edema in the bone and soft tissues are normal findings during the resorption of magnesium screws and should not be misinterpreted as infection. Gas can also be detected within growth plates. MRI examinations can be performed without metal artifact reduction sequences. Standard fat suppression techniques are not significantly affected.
- 21 April 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (8) , 3016
Open AccessProspective Evaluation of Magnetic Resonance Imaging Features of Magnesium-Based Alloy Screw Resorption in Pediatric Fractures
Background: The resorption of magnesium-based alloy bioabsorbable screws results in the release of hydrogen gas, which can mimic infection and enter the growth plate. The screw itself and the released gas may also affect image quality. Objective: The evaluation of magnetic resonance imaging (MRI) findings during the most active phase of screw resorption is the objective, with particular focus on the growth plate and to assess for the presence of metal-induced artifacts. Material and Methods: In total, 30 prospectively acquired MRIs from 17 pediatric patients with fractures treated with magnesium screws were assessed for the presence and distribution of intraosseous, extraosseous, and intra-articular gas; gas within the growth plate; osteolysis along the screw; joint effusion; bone marrow edema; periosteal reaction; soft tissue edema; and metal-induced artifacts. Results: Gas locules were found in the bone and soft tissues in 100% of the examinations, intra-articular in 40%, and in 37% of unfused growth plates. Osteolysis and the periosteal reaction were present in 87%, bone marrow edema in 100%, soft tissue edema in 100%, and joint effusion in 50% of examinations. Pile-up artifacts were present in 100%, and geometric distortion in 0% of examinations. Fat suppression was not significantly impaired in any examination. Conclusions: Gas and edema in the bone and soft tissues are normal findings during the resorption of magnesium screws and should not be misinterpreted as infection. Gas can also be detected within growth plates. MRI examinations can be performed without metal artifact reduction sequences. Standard fat suppression techniques are not significantly affected.
- 15 July 2022
- Published by Springer Nature in Pediatric Radiology
- Vol. 52 (13) , 2584-2594
Organ-based tube current modulation and bismuth eye shielding in pediatric head computed tomography
Background Exposure of the eye lens to ionizing radiation results in cataract. Several dose optimization techniques to protect the lens are available for computed tomography (CT). Objective The radiation dose to the eye lens, volume CT dose index (CTDIvol) and image quality of various methods of dose optimization were evaluated for pediatric head CT: automated tube current modulation (ATCM), automated tube voltage selection (ATVS), organ-based tube current modulation (OBTCM) and bismuth shielding. Materials and methods An anthropomorphic phantom of a 5-year-old child was scanned with nine protocols: no dose optimization technique and then adding different dose optimization techniques alone and in combination. Dose to the eye, thyroid and breast were estimated using metal oxide semiconductor field effect transistor (MOSFET) dosimetry. CTDIvol, influence of timing of shield placement, image noise and attenuation values in 13 regions of interest of the head and subjective image quality were compared. Results The eye shield significantly reduced the eye lens dose when used alone, to a similar degree as when using all software-based techniques together. When used in combination with software-based techniques, the shield reduced the eye lens dose by up to 45% compared to the no dose optimization technique. Noise was significantly increased by the shield, most pronounced in the anterior portion of the eye. Conclusion The combination of ATCM, ATVS, OBTCM and a bismuth shield, with the shield placed after acquiring the localizer image, should be considered to reduce the radiation dose to the eye lens in pediatric head CT.
- 15 July 2022
- Published by Springer Nature in Pediatric Radiology
- Vol. 52 (13) , 2584-2594
Organ-based tube current modulation and bismuth eye shielding in pediatric head computed tomography
Background Exposure of the eye lens to ionizing radiation results in cataract. Several dose optimization techniques to protect the lens are available for computed tomography (CT). Objective The radiation dose to the eye lens, volume CT dose index (CTDIvol) and image quality of various methods of dose optimization were evaluated for pediatric head CT: automated tube current modulation (ATCM), automated tube voltage selection (ATVS), organ-based tube current modulation (OBTCM) and bismuth shielding. Materials and methods An anthropomorphic phantom of a 5-year-old child was scanned with nine protocols: no dose optimization technique and then adding different dose optimization techniques alone and in combination. Dose to the eye, thyroid and breast were estimated using metal oxide semiconductor field effect transistor (MOSFET) dosimetry. CTDIvol, influence of timing of shield placement, image noise and attenuation values in 13 regions of interest of the head and subjective image quality were compared. Results The eye shield significantly reduced the eye lens dose when used alone, to a similar degree as when using all software-based techniques together. When used in combination with software-based techniques, the shield reduced the eye lens dose by up to 45% compared to the no dose optimization technique. Noise was significantly increased by the shield, most pronounced in the anterior portion of the eye. Conclusion The combination of ATCM, ATVS, OBTCM and a bismuth shield, with the shield placed after acquiring the localizer image, should be considered to reduce the radiation dose to the eye lens in pediatric head CT.
- Open Access
- 24 June 2022
- Published by Elsevier in European Journal of Radiology Open
- Vol. 9, 100431
Comparison of temporal evolution of computed tomography imaging features in COVID-19 and influenza infections in a multicenter cohort study
- 24 June 2022
- Published by Elsevier in European Journal of Radiology Open
- Vol. 9, 100431
Open AccessComparison of temporal evolution of computed tomography imaging features in COVID-19 and influenza infections in a multicenter cohort study
- Open Access
- 11 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (5) , 1201
Clinical and Imaging Features of COVID-19-Associated Pulmonary Aspergillosis
Background: COVID-19 superinfection by Aspergillus (COVID-19-associated aspergillosis, CAPA) is increasingly observed due to increased awareness and use of corticosteroids. The aim of this study is to compare clinical and imaging features between COVID-19 patients with and without associated pulmonary aspergillosis. Material and Methods: In this case–control study, hospitalized patients between March 2020 and March 2021 were evaluated. Two observers independently compared 105 chest CTs of 52 COVID-19 patients without pulmonary aspergillosis to 40 chest CTs of 13 CAPA patients. The following features were evaluated: lung involvement, predominant main pattern (ground glass opacity, crazy paving, consolidation) and additional lung and chest findings. Chronological changes in the abnormal extent upon CT and chronological changes in the main patterns were compared with mixed models. Patient-wise comparisons of additional features and demographic and clinical data were performed using Student’s t-test, Chi-squared test, Fisher’s exact tests and Wilcoxon rank-sum tests. Results: Compared to COVID-19 patients without pulmonary aspergillosis, CAPA patients were older (mean age (±SD): 70.3 (±7.8) versus 63.5 (±9.5) years (p = 0.01). The time-dependent evolution rates for consolidation (p = 0.02) and ground glass (p = 0.006) differed. In early COVID-19 disease, consolidation was associated with CAPA, whereas ground glass was less common. Chronological changes in the abnormal extent upon CT did not differ (p = 0.29). Regardless of the time point, bronchial wall thickening was observed more frequently in CAPA patients (p = 0.03). Conclusions: CAPA patients showed a tendency for consolidation in early COVID-19 disease. Bronchial wall thickening and higher patient age were associated with CAPA. The overall lung involvement was similar between both groups.
- 11 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (5) , 1201
Open AccessClinical and Imaging Features of COVID-19-Associated Pulmonary Aspergillosis
Background: COVID-19 superinfection by Aspergillus (COVID-19-associated aspergillosis, CAPA) is increasingly observed due to increased awareness and use of corticosteroids. The aim of this study is to compare clinical and imaging features between COVID-19 patients with and without associated pulmonary aspergillosis. Material and Methods: In this case–control study, hospitalized patients between March 2020 and March 2021 were evaluated. Two observers independently compared 105 chest CTs of 52 COVID-19 patients without pulmonary aspergillosis to 40 chest CTs of 13 CAPA patients. The following features were evaluated: lung involvement, predominant main pattern (ground glass opacity, crazy paving, consolidation) and additional lung and chest findings. Chronological changes in the abnormal extent upon CT and chronological changes in the main patterns were compared with mixed models. Patient-wise comparisons of additional features and demographic and clinical data were performed using Student’s t-test, Chi-squared test, Fisher’s exact tests and Wilcoxon rank-sum tests. Results: Compared to COVID-19 patients without pulmonary aspergillosis, CAPA patients were older (mean age (±SD): 70.3 (±7.8) versus 63.5 (±9.5) years (p = 0.01). The time-dependent evolution rates for consolidation (p = 0.02) and ground glass (p = 0.006) differed. In early COVID-19 disease, consolidation was associated with CAPA, whereas ground glass was less common. Chronological changes in the abnormal extent upon CT did not differ (p = 0.29). Regardless of the time point, bronchial wall thickening was observed more frequently in CAPA patients (p = 0.03). Conclusions: CAPA patients showed a tendency for consolidation in early COVID-19 disease. Bronchial wall thickening and higher patient age were associated with CAPA. The overall lung involvement was similar between both groups.
- Open Access
- 16 September 2021
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 105 (1)
Effects of Changing the Reporting System from Decentralized/Modality-Based to Centralized/Subspecialized Radiology on Radiologists, Radiologic Technicians and Referring Physicians of a Multi-Center Radiology Network
To determine the effects of reorganizing a radiology institute from decentralized/modality-based to centralized/subspecialized radiology on radiologists, radiologic technicians, and referring physicians at a multi-center radiology network. In 2017/2018 our multi-center radiology network was changed from decentralized/modality-based to centralized/subspecialized reporting. A survey was conducted among radiologists, technicians and two groups of referring physicians (main hospital and non-main hospitals). The following items were tested: Overall satisfaction, perceived quality of radiological reports, subjective productivity/efficiency, confidence of radiologists in their subspecialty, availability of radiologists and turnaround time. Two of five answering options on a 5-point Likert scale were considered to represent agreement. The Mann-Whitney-U-test served for statistical analyses in agreement before and after reorganization in each group. For radiologists, a significant difference was observed in perceived quality of radiological reports 42/46 (91.3%) compared to 51/52 (98.1%; p = 0.013). For technicians, no significant differences were observed. In the group of main hospital referring physicians, significant differences were observed in overall satisfaction 129/152 (84.9%) compared to 164/174 (94.3%; p < 0.001) and in perceived quality of radiological reports 125/148 (72.8%) compared to 157/170 (92.4%; p = 0.001). In the group of non-main hospital referring physicians no significant differences were observed. The reorganization resulted in a significantly higher perceived quality of radiological reports for the groups of radiologists and main hospital referring physicians besides overall satisfaction for main hospital referring physicians. Specialized main hospital referring physicians value reports of specialized radiology, whereas less specialized, non-main hospital referring physicians did not experience any significant effect.
- 16 September 2021
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 105 (1)
Open AccessEffects of Changing the Reporting System from Decentralized/Modality-Based to Centralized/Subspecialized Radiology on Radiologists, Radiologic Technicians and Referring Physicians of a Multi-Center Radiology Network
To determine the effects of reorganizing a radiology institute from decentralized/modality-based to centralized/subspecialized radiology on radiologists, radiologic technicians, and referring physicians at a multi-center radiology network. In 2017/2018 our multi-center radiology network was changed from decentralized/modality-based to centralized/subspecialized reporting. A survey was conducted among radiologists, technicians and two groups of referring physicians (main hospital and non-main hospitals). The following items were tested: Overall satisfaction, perceived quality of radiological reports, subjective productivity/efficiency, confidence of radiologists in their subspecialty, availability of radiologists and turnaround time. Two of five answering options on a 5-point Likert scale were considered to represent agreement. The Mann-Whitney-U-test served for statistical analyses in agreement before and after reorganization in each group. For radiologists, a significant difference was observed in perceived quality of radiological reports 42/46 (91.3%) compared to 51/52 (98.1%; p = 0.013). For technicians, no significant differences were observed. In the group of main hospital referring physicians, significant differences were observed in overall satisfaction 129/152 (84.9%) compared to 164/174 (94.3%; p < 0.001) and in perceived quality of radiological reports 125/148 (72.8%) compared to 157/170 (92.4%; p = 0.001). In the group of non-main hospital referring physicians no significant differences were observed. The reorganization resulted in a significantly higher perceived quality of radiological reports for the groups of radiologists and main hospital referring physicians besides overall satisfaction for main hospital referring physicians. Specialized main hospital referring physicians value reports of specialized radiology, whereas less specialized, non-main hospital referring physicians did not experience any significant effect.