Heather L. Bloom

Heather L. Bloom

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Heather L. Bloom has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical use of antibacterial mesh envelopes in cardiovascular electronic device implantations

    by Heather L. Bloom, David S Hirsh

    Cardiovascular implantable electronic device system infection is a serious complication of cardiac device implantation and carries with it a risk of significant morbidity and mortality. In the last 15 years, expansions of indications for cardiac devices have resulted in much higher volumes of much sicker patients being implanted, carrying significant risk of infection. Coagulase (-) Staphylococcus and Staphylococcus aureus are responsible for the majority of these infections, and these organisms are increasingly resistant to methicillin. The Aigis™ envelop is a Food and Drug Administration–approved implantable mesh that is impregnated with antibiotics that can be placed in the surgical incision prior to closure. The antibiotics elute off the mesh for 7–10 days, providing in vivo surgical site coverage with rifampin and minocyclin. This paper reviews the three retrospective clinical trials published in peer-reviewed journals and the interim analysis of the two ongoing prospective trials that have been presented at international conferences. Overall consensus is that the Aigis™ offers significant risk reduction for cardiovascular implantable electronic device infection. We then give a comprehensive discussion of how to use the Aigis™ envelop in the clinical setting, comparing the manufacturer’s recommendations with our extensive clinical experience.


  • EFFECT OF ANGIOTENSIN CONVERTING ENZYME INHIBITORS AND RECEPTOR BLOCKERS ON APPROPRIATE IMPLANTABLE CARDIAC DEFIBRILLATOR SHOCK: INSIGHTS FROM THE GRADE MULTICENTER STUDY

    by Wael AlJaroudi, Marwan Refaat, Robert Habib, Laila Al Shaar, Rebecca Gutmann, Heather Bloom, Samuel Dudley, Patrick Ellinor, Dennis McNamara, Samir Saba, et al.

  • Implantation Success and Infection in Cardiovascular Implantable Electronic Device Procedures Utilizing an Antibacterial Envelope

    by Heather L. Bloom, Luis Constantin, Daniel Dan, David B. De Lurgio, Mikhail El‐Chami, Leonard I. Ganz, Kent J. Gleed, F. Kevin Hackett, Narendra K. Kanuru, Daniel J. Lerner, et al.

    Background: Cardiovascular implantable electronic device (CIED) infection rates are increasing faster than implantation rates. More effective antimicrobial prophylaxis may help reduce CIED infections and improve clinical outcomes. The AIGISRx® antibacterial envelope is a polymer mesh implanted in the generator pocket with the CIED. After implantation it releases two antibiotics, minocycline and rifampin, that have been shown to reduce infections associated with other medical devices. The purpose of this retrospective cohort study is to determine the rate of CIED implantation success and CIED infection in procedures utilizing the antibacterial envelope. Methods: This study enrolled consecutive CIED procedures utilizing the antibacterial envelope at 10 US academic, community, and Veterans Affairs medical centers. Procedures following an explantation for a prior CIED infection or off‐label use of the antibacterial envelope were excluded. Results: The 624 eligible procedures (age 70 ± 13 years, 68.1% men, 27.2% renal insufficiency, 35.4% oral anticoagulant use, 67.8% replacement/revision procedures) utilized pacemakers (35%), implantable cardioverter‐defibrillators (ICD)(29%), and cardiac resynchronization therapy with defibrillator devices (CRT‐D)(36%). Nearly half of the patients (49%) had at least three predefined risk factors for CIED infection. CIED implantation was successful in 621 procedures (99.5%[95% confidence interval (CI) 98.8–99.9]). There were three major infections (0.48%[95%CI 0.17–1.40]) after 1.9 ± 2.4 months follow‐up. The infections followed one ICD revision and two CRT‐D replacements. There were seven deaths; none was a result of the antibacterial envelope or the CIED procedure. Conclusions: CIED procedures that utilized an antibacterial envelope had a high rate of CIED implantation success (>99%). Although the follow‐up to date is short, there was also a low rate of infection (


  • Open Access

    Statins Decrease Oxidative Stress and ICD Therapies

    by Heather L. Bloom, Irfan Shukrullah, Emir Veledar, Rebecca Gutmann, Barry London, Samuel C. Dudley

    Recent studies demonstrate that statins decrease ventricular arrhythmias in internal cardioverter defibrillator (ICD) patients. The mechanism is unknown, but evidence links increased inflammatory and oxidative states with increased arrhythmias. We hypothesized that statin use decreases oxidation.Methods.304 subjects with ICDs were surveyed for ventricular arrhythmia. Blood was analyzed for derivatives of reactive oxygen species (DROMs) and interleukin-6 (IL-6).Results.Subjects included 252 (83%) men, 58% on statins, 20% had ventricular arrhythmias. Average age was 63 years and ejection fraction (EF) 20%. ICD implant duration was 29±27 months. Use of statins correlated with lower ICD events (r=0.12,P=.02). Subjects on statins had lower hsCRP (5.2 versus 6.3;P=.05) and DROM levels (373 versus 397;P=.03). Other factors, including IL-6 and EF did not differ between statin and nonstatin use, nor did beta-blocker or antiarrhythmic use. Multivariate cross-correlation analysis demonstrated that DROMs, statins, IL-6 and EF were strongly associated with ICD events. Multivariate regression shows DROMs to be the dominant predictor.Conclusion.ICD event rate correlates with DROMs, a measure of lipid peroxides. Use of statins is associated with reduced DROMs and fewer ICD events, suggesting that statins exert their effect through reducing oxidation.


  • Open Access

    Treatment of ventricular tachycardia: consider ablation sooner

    by Heather L Bloom

    Treatment of ventricular tachycardia: consider ablation sooner


  • Open Access

    Automated external cardioversion defibrillation monitoring in cardiac arrest: a randomized trial

    by Bakhtiar Ali, Heather Bloom, Emir Veledar, Dorothy House, Robert Norvel, Samuel C Dudley, A Maziar Zafari

    Background: In-hospital cardiac arrest has a poor prognosis despite active electrocardiography monitoring. The initial rhythm of approximately 25% of in-hospital cardiopulmonary resuscitation (CPR) events is pulseless ventricular tachycardia/ventricular fibrillation (VT/VF). Early defibrillation is an independent predictor of survival in CPR events caused by VT/VF. The automated external cardioverter defibrillator (AECD) is a device attached by pads to the chest wall that monitors, detects, and within seconds, automatically delivers electric countershock to an appropriate tachyarrhythmia. Study Objectives: • To evaluate safety of AECD monitoring in hospitalized patients. • To evaluate whether AECDs provide earlier defibrillation than hospital code teams. Methods: The study is a prospective trial randomizing patients admitted to the telemetry ward to standard CPR (code team) or standard CPR plus AECD monitoring (PowerHeart CRM). The AECD is programmed to deliver one 150 J biphasic shock to patients in sustained VT/VF. Data is collected using the Utstein criteria for cardiac arrest. The primary endpoint is time-to-defibrillation; secondary outcomes include neurological status and survival to discharge, with 3-year follow-up. Results: To date, 192 patients have been recruited in the time period between 10/10/2006 to 7/20/2007. A total of 3,655 hours of telemetry data have been analyzed in the AECD arm. The AECD has monitored ambulatory telemetry patients in sinus rhythm, sinus tachycardia, supraventricular tachycardia, atrial flutter or fibrillation, with premature ventricular complexes and non-sustained VT without delivery of inappropriate shocks. One patient experienced sustained VT during AECD monitoring, who was successfully defibrillated (17 seconds after meeting programmed criteria). There are no events to report in the control arm. The patient survived the event without neurological complications. During the same time period, mean time to shock for VT/VF cardiac arrest occurring outside the telemetry ward was 230 ± 50 seconds. Conclusion: AECD monitoring is safe and likely results in earlier defibrillation than standard telemetry monitoring. Trial Registration: National Institutes of Health registration ID: NCT00382928


  • Long-term survival after successful inhospital cardiac arrest resuscitation

    by Heather L. Bloom, Irfan Shukrullah, Jose R. Cuellar, Michael S. Lloyd, Samuel C. Dudley, A. Maziar Zafari