Wassana Yantasee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wassana Yantasee has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Glen E. Fryxell
Pacific Northwest National Laboratory (PNNL), P.O. Box 999, Richland, WA 99352, United States
4 shared publicationsR. Shane Addleman
Pacific Northwest National Laboratory (PNNL), P.O. Box 999, Richland, WA 99352, United States
4 shared publicationsCharles Timchalk
3 shared publicationsCynthia L. Warner
Pacific Northwest National Laboratory (PNNL), Richland, WA, USA
2 shared publicationsMarvin G. Warner
Pacific Northwest National Laboratory (PNNL), Richland, WA, USA
2 shared publicationsRobert J. Wiacek
Pacific Northwest National Laboratory (PNNL), P.O. Box 999, Richland, WA 99352, United States
2 shared publications
Latest Publications
- 1 September 2009
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 168 (2-3) , 1233-1238
Selective removal of lanthanides from natural waters, acidic streams and dialysate
- 1 September 2009
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 168 (2-3) , 1233-1238
Selective removal of lanthanides from natural waters, acidic streams and dialysate
- 1 July 2008
- Published by Elsevier in Analytica Chimica Acta
- Vol. 620 (1-2) , 55-63
Detection of Cd, Pb, and Cu in non-pretreated natural waters and urine with thiol functionalized mesoporous silica and Nafion composite electrodes
- 1 July 2008
- Published by Elsevier in Analytica Chimica Acta
- Vol. 620 (1-2) , 55-63
Detection of Cd, Pb, and Cu in non-pretreated natural waters and urine with thiol functionalized mesoporous silica and Nafion composite electrodes
- 1 February 2008
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 133 (3) , 348-355
Direct detection of Pb in urine and Cd, Pb, Cu, and Ag in natural waters using electrochemical sensors immobilized with DMSA functionalized magnetic nanoparticles
Urine is universally recognized as one of the best non-invasive matrices for biomonitoring exposure to a broad range of xenobiotics, including toxic metals. Detection of metal ions in urine has been problematic due to the protein competition and electrode fouling. For direct, simple, and field-deployable monitoring of urinary Pb, electrochemical sensors employing superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) has been developed. The metal detection involves rapid collection of dispersed metal-bound nanoparticles from a sample solution at a magnetic or electromagnetic electrode, followed by the stripping voltammetry of the metal in acidic medium. The sensors were evaluated as a function of solution pH, the binding affinity of Pb to DMSA–Fe3O4, the ratio of nanoparticles per sample volume, preconcentration time, and Pb concentrations. The effect of binding competitions between the DMSA–Fe3O4 and urine constituents for Pb on the sensor responses was studied. After 90 s of preconcentration in samples containing 25 vol.% of rat urine and 0.1 g L−1 of DMSA–Fe3O4, the sensor could detect background level of Pb (0.5 ppb) and yielded linear responses from 0 to 50 ppb of Pb, excellent reproducibility (%RSD of 5.3 for seven measurements of 30 ppb Pb), and Pb concentrations comparable to those measured by ICP-MS. The sensor could also simultaneously detect background levels (<1 ppb) of Cd, Pb, Cu, and Ag in river and seawater.
- 1 February 2008
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 133 (3) , 348-355
Direct detection of Pb in urine and Cd, Pb, Cu, and Ag in natural waters using electrochemical sensors immobilized with DMSA functionalized magnetic nanoparticles
Urine is universally recognized as one of the best non-invasive matrices for biomonitoring exposure to a broad range of xenobiotics, including toxic metals. Detection of metal ions in urine has been problematic due to the protein competition and electrode fouling. For direct, simple, and field-deployable monitoring of urinary Pb, electrochemical sensors employing superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) has been developed. The metal detection involves rapid collection of dispersed metal-bound nanoparticles from a sample solution at a magnetic or electromagnetic electrode, followed by the stripping voltammetry of the metal in acidic medium. The sensors were evaluated as a function of solution pH, the binding affinity of Pb to DMSA–Fe3O4, the ratio of nanoparticles per sample volume, preconcentration time, and Pb concentrations. The effect of binding competitions between the DMSA–Fe3O4 and urine constituents for Pb on the sensor responses was studied. After 90 s of preconcentration in samples containing 25 vol.% of rat urine and 0.1 g L−1 of DMSA–Fe3O4, the sensor could detect background level of Pb (0.5 ppb) and yielded linear responses from 0 to 50 ppb of Pb, excellent reproducibility (%RSD of 5.3 for seven measurements of 30 ppb Pb), and Pb concentrations comparable to those measured by ICP-MS. The sensor could also simultaneously detect background levels (<1 ppb) of Cd, Pb, Cu, and Ag in river and seawater.
- Top Cited Papers
- 9 June 2007
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 41 (14) , 5114-5119
Removal of Heavy Metals from Aqueous Systems with Thiol Functionalized Superparamagnetic Nanoparticles
We have shown that superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) are an effective sorbent material for toxic soft metals such as Hg, Ag, Pb, Cd, and Tl, which effectively bind to the DMSA ligands and for As, which binds to the iron oxide lattices. The nanoparticles are highly dispersible and stable in solutions, have a large surface area (114 m2/g), and have a high functional group content (1.8 mmol thiols/g). They are attracted to a magnetic field and can be separated from solution within a minute with a 1.2 T magnet. The chemical affinity, capacity, kinetics, and stability of the magnetic nanoparticles were compared to those of conventional resin based sorbents (GT-73), activated carbon, and nanoporous silica (SAMMS) of similar surface chemistries in river water, groundwater, seawater, and human blood and plasma. DMSA-Fe3O4 had a capacity of 227 mg of Hg/g, a 30-fold larger value than GT-73. The nanoparticles removed 99 wt % of 1 mg/L Pb within a minute, while it took over 10 and 120 min for Chelex-100 and GT-73 to remove 96% of Pb.
- 9 June 2007
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 41 (14) , 5114-5119
Top Cited PapersRemoval of Heavy Metals from Aqueous Systems with Thiol Functionalized Superparamagnetic Nanoparticles
We have shown that superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) are an effective sorbent material for toxic soft metals such as Hg, Ag, Pb, Cd, and Tl, which effectively bind to the DMSA ligands and for As, which binds to the iron oxide lattices. The nanoparticles are highly dispersible and stable in solutions, have a large surface area (114 m2/g), and have a high functional group content (1.8 mmol thiols/g). They are attracted to a magnetic field and can be separated from solution within a minute with a 1.2 T magnet. The chemical affinity, capacity, kinetics, and stability of the magnetic nanoparticles were compared to those of conventional resin based sorbents (GT-73), activated carbon, and nanoporous silica (SAMMS) of similar surface chemistries in river water, groundwater, seawater, and human blood and plasma. DMSA-Fe3O4 had a capacity of 227 mg of Hg/g, a 30-fold larger value than GT-73. The nanoparticles removed 99 wt % of 1 mg/L Pb within a minute, while it took over 10 and 120 min for Chelex-100 and GT-73 to remove 96% of Pb.
- 1 January 2005
- Published by American Scientific Publishers in Sensor Letters
- Vol. 3 (1) , 16-21
Electrochemical Sensor Based on Carbon Paste Electrode Modified with Nanostructured Cryptomelane-Type Manganese Oxides for Detection of Heavy Metals
- 1 January 2005
- Published by American Scientific Publishers in Sensor Letters
- Vol. 3 (1) , 16-21
Electrochemical Sensor Based on Carbon Paste Electrode Modified with Nanostructured Cryptomelane-Type Manganese Oxides for Detection of Heavy Metals