Kelly H. Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kelly H. Zou has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Ron Kikinis
4 shared publications- Simon Keith Warfield
Department of Radiology Boston Children's Hospital Boston Massachusetts USA
4 shared publications Stuart G. Silverman
3 shared publicationsWilliam M. Wells
3 shared publicationsFerenc A. Jolesz
2 shared publicationsFrederic S. Resnic
2 shared publications
Latest Publications
- 1 May 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (5) , 566-572
Statistical Combination Schemes of Repeated Diagnostic Test Data
- 1 May 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (5) , 566-572
Statistical Combination Schemes of Repeated Diagnostic Test Data
- 29 March 2006
- Published by Springer Nature in Cellular and Molecular Life Sciences
- Vol. 63 (10) , 1106-1124
Magnetic resonance and the human brain: anatomy, function and metabolism
The introduction and development, over the last three decades, of magnetic resonance (MR) imaging and MR spectroscopy technology for in vivo studies of the human brain represents a truly remarkable achievement, with enormous scientific and clinical ramifications. These effectively non-invasive techniques allow for studies of the anatomy, the function and the metabolism of the living human brain. They have allowed for new understandings of how the healthy brain works and have provided insights into the mechanisms underlying multiple disease processes which affect the brain. Different MR techniques have been developed for studying anatomy, function and metabolism. The primary focus of this review is to describe these different methodologies and to briefly review how they are being employed to more fully appreciate the intricacies associated with the organ, which most distinctly differentiates the human species from the other animal forms on earth.
- 29 March 2006
- Published by Springer Nature in Cellular and Molecular Life Sciences
- Vol. 63 (10) , 1106-1124
Magnetic resonance and the human brain: anatomy, function and metabolism
The introduction and development, over the last three decades, of magnetic resonance (MR) imaging and MR spectroscopy technology for in vivo studies of the human brain represents a truly remarkable achievement, with enormous scientific and clinical ramifications. These effectively non-invasive techniques allow for studies of the anatomy, the function and the metabolism of the living human brain. They have allowed for new understandings of how the healthy brain works and have provided insights into the mechanisms underlying multiple disease processes which affect the brain. Different MR techniques have been developed for studying anatomy, function and metabolism. The primary focus of this review is to describe these different methodologies and to briefly review how they are being employed to more fully appreciate the intricacies associated with the organ, which most distinctly differentiates the human species from the other animal forms on earth.
- 1 December 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 237 (3) , 781-789
Reproducibility of Functional MR Imaging: Preliminary Results of Prospective Multi-institutional Study Performed by Biomedical Informatics Research Network
PURPOSE: To prospectively investigate the factors—including subject, brain hemisphere, study site, field strength, imaging unit vendor, imaging run, and examination visit—affecting the reproducibility of functional magnetic resonance (MR) imaging activations based on a repeated sensory-motor (SM) task. MATERIALS AND METHODS: The institutional review boards of all participating sites approved this HIPAA-compliant study. All subjects gave informed consent. Functional MR imaging data were repeatedly acquired from five healthy men aged 20–29 years who performed the same SM task at 10 sites. Five 1.5-T MR imaging units, four 3.0-T units, and one 4.0-T unit were used. The subjects performed bilateral finger tapping on button boxes with a 3-Hz audio cue and a reversing checkerboard. In a block design, 15-second epochs of alternating baseline and tasks yielded 85 acquisitions per run. Functional MR images were acquired with block-design echo-planar or spiral gradient-echo sequences. Brain activation maps standardized in a unit-sphere for the left and right hemispheres of each subject were constructed. Areas under the receiver operating characteristic curve, intraclass correlation coefficients, multiple regression analysis, and paired Student t tests were used for statistical analyses. RESULTS: Significant factors were subject (P < .005), k-space (P < .005), and field strength (P = .02) for sensitivity and subject (P = .03) and k-space (P = .05) for specificity. At 1.5-T MR imaging, mean sensitivities ranged from 7% to 32% and mean specificities were higher than 99%. At 3.0 T, mean sensitivities and specificities ranged from 42% to 85% and from 96% to 99%, respectively. At 4.0 T, mean sensitivities and specificities ranged from 41% to 73% and from 95% to 99%, respectively. Mean areas under the receiver operating characteristic curve (± their standard errors) were 0.77 ± 0.05 at 1.5 T, 0.90 ± 0.09 at 3.0 T, and 0.95 ± 0.02 at 4.0 T, with significant differences between the 1.5- and 3.0-T examinations and between the 1.5- and 4.0-T examinations (P < .01 for both comparisons). Intraclass correlation coefficients ranged from 0.49 to 0.71. CONCLUSION: MR imaging at 3.0- and 4.0-T yielded higher reproducibility across sites and significantly better results than 1.5-T imaging. The effects of subject, k-space, and field strength on examination reproducibility were significant. © RSNA, 2005
- 1 December 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 237 (3) , 781-789
Reproducibility of Functional MR Imaging: Preliminary Results of Prospective Multi-institutional Study Performed by Biomedical Informatics Research Network
PURPOSE: To prospectively investigate the factors—including subject, brain hemisphere, study site, field strength, imaging unit vendor, imaging run, and examination visit—affecting the reproducibility of functional magnetic resonance (MR) imaging activations based on a repeated sensory-motor (SM) task. MATERIALS AND METHODS: The institutional review boards of all participating sites approved this HIPAA-compliant study. All subjects gave informed consent. Functional MR imaging data were repeatedly acquired from five healthy men aged 20–29 years who performed the same SM task at 10 sites. Five 1.5-T MR imaging units, four 3.0-T units, and one 4.0-T unit were used. The subjects performed bilateral finger tapping on button boxes with a 3-Hz audio cue and a reversing checkerboard. In a block design, 15-second epochs of alternating baseline and tasks yielded 85 acquisitions per run. Functional MR images were acquired with block-design echo-planar or spiral gradient-echo sequences. Brain activation maps standardized in a unit-sphere for the left and right hemispheres of each subject were constructed. Areas under the receiver operating characteristic curve, intraclass correlation coefficients, multiple regression analysis, and paired Student t tests were used for statistical analyses. RESULTS: Significant factors were subject (P < .005), k-space (P < .005), and field strength (P = .02) for sensitivity and subject (P = .03) and k-space (P = .05) for specificity. At 1.5-T MR imaging, mean sensitivities ranged from 7% to 32% and mean specificities were higher than 99%. At 3.0 T, mean sensitivities and specificities ranged from 42% to 85% and from 96% to 99%, respectively. At 4.0 T, mean sensitivities and specificities ranged from 41% to 73% and from 95% to 99%, respectively. Mean areas under the receiver operating characteristic curve (± their standard errors) were 0.77 ± 0.05 at 1.5 T, 0.90 ± 0.09 at 3.0 T, and 0.95 ± 0.02 at 4.0 T, with significant differences between the 1.5- and 3.0-T examinations and between the 1.5- and 4.0-T examinations (P < .01 for both comparisons). Intraclass correlation coefficients ranged from 0.49 to 0.71. CONCLUSION: MR imaging at 3.0- and 4.0-T yielded higher reproducibility across sites and significantly better results than 1.5-T imaging. The effects of subject, k-space, and field strength on examination reproducibility were significant. © RSNA, 2005
- 1 October 2005
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 38 (5) , 395-403
A global goodness-of-fit test for receiver operating characteristic curve analysis via the bootstrap method
- 1 October 2005
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 38 (5) , 395-403
A global goodness-of-fit test for receiver operating characteristic curve analysis via the bootstrap method
- 4 August 2005
- Published by Wiley in Biometrical Journal
- Vol. 47 (4) , 417-427
A Bayesian Hierarchical Non-Linear Regression Model in Receiver Operating Characteristic Analysis of Clustered Continuous Diagnostic Data
- 4 August 2005
- Published by Wiley in Biometrical Journal
- Vol. 47 (4) , 417-427
A Bayesian Hierarchical Non-Linear Regression Model in Receiver Operating Characteristic Analysis of Clustered Continuous Diagnostic Data
- 1 April 2005
- Published by Elsevier in Academic Radiology
- Vol. 12 (4) , 444-450
Three-dimensional assessment of MR imaging-guided percutaneous cryotherapy using multi-performer repeated segmentations
- 1 April 2005
- Published by Elsevier in Academic Radiology
- Vol. 12 (4) , 444-450
Three-dimensional assessment of MR imaging-guided percutaneous cryotherapy using multi-performer repeated segmentations
- 5 April 2004
- Published by Wiley in Statistics in Medicine
- Vol. 23 (8) , 1259-1282
Three validation metrics for automated probabilistic image segmentation of brain tumours
The validity of brain tumour segmentation is an important issue in image processing because it has a direct impact on surgical planning. We examined the segmentation accuracy based on three two‐sample validation metrics against the estimated composite latent gold standard, which was derived from several experts' manual segmentations by an EM algorithm. The distribution functions of the tumour and control pixel data were parametrically assumed to be a mixture of two beta distributions with different shape parameters. We estimated the corresponding receiver operating characteristic curve, Dice similarity coefficient, and mutual information, over all possible decision thresholds. Based on each validation metric, an optimal threshold was then computed via maximization. We illustrated these methods on MR imaging data from nine brain tumour cases of three different tumour types, each consisting of a large number of pixels. The automated segmentation yielded satisfactory accuracy with varied optimal thresholds. The performances of these validation metrics were also investigated via Monte Carlo simulation. Extensions of incorporating spatial correlation structures using a Markov random field model were considered. Copyright © 2004 John Wiley & Sons, Ltd.
- 5 April 2004
- Published by Wiley in Statistics in Medicine
- Vol. 23 (8) , 1259-1282
Three validation metrics for automated probabilistic image segmentation of brain tumours
The validity of brain tumour segmentation is an important issue in image processing because it has a direct impact on surgical planning. We examined the segmentation accuracy based on three two‐sample validation metrics against the estimated composite latent gold standard, which was derived from several experts' manual segmentations by an EM algorithm. The distribution functions of the tumour and control pixel data were parametrically assumed to be a mixture of two beta distributions with different shape parameters. We estimated the corresponding receiver operating characteristic curve, Dice similarity coefficient, and mutual information, over all possible decision thresholds. Based on each validation metric, an optimal threshold was then computed via maximization. We illustrated these methods on MR imaging data from nine brain tumour cases of three different tumour types, each consisting of a large number of pixels. The automated segmentation yielded satisfactory accuracy with varied optimal thresholds. The performances of these validation metrics were also investigated via Monte Carlo simulation. Extensions of incorporating spatial correlation structures using a Markov random field model were considered. Copyright © 2004 John Wiley & Sons, Ltd.
- 1 February 2004
- Published by Elsevier in Academic Radiology
- Vol. 11 (2) , 127-133
What is evidence-based medicine?1
- 1 February 2004
- Published by Elsevier in Academic Radiology
- Vol. 11 (2) , 127-133
What is evidence-based medicine?1
- 1 December 2003
- Published by Elsevier in Academic Radiology
- Vol. 10 (12) , 1359-1368
Statistical validation based on parametric receiver operating characteristic analysis of continuous classification data1
- 1 December 2003
- Published by Elsevier in Academic Radiology
- Vol. 10 (12) , 1359-1368
Statistical validation based on parametric receiver operating characteristic analysis of continuous classification data1
- 16 October 2003
- Published by Wiley in Biometrical Journal
- Vol. 45 (7) , 826-836
Efficient Bayesian Sample Size Calculation for Designing a Clinical Trial with Multi‐Cluster Outcome Data
Health care utilization and outcome studies call for hierarchical approaches. The objectives were to predict major complications following percutaneous coronary interventions by health providers, and to compare Bayesian and non‐Bayesian sample size calculation methods. The hierarchical data structure consisted of: (1) Strata: PGY4, PGY7, and physician assistant as providers with varied experiences; (2) Clusters: ks providers per stratum; (3) Individuals: ns patients reviewed by each provider. The main outcome event illustrated was mortality modeled by a Bayesian beta‐binomial model. Pilot information and assumptions were utilized to elicit beta prior distributions. Sample size calculations were based on the approximated average length, fixed at 1%, of 95% posterior intervals of the mean event rate parameter. Necessary sample sizes by both non‐Bayesian and Bayesian methods were compared. We demonstrated that the developed Bayesian methods can be efficient and may require fewer subjects to satisfy the same length criterion.
- 16 October 2003
- Published by Wiley in Biometrical Journal
- Vol. 45 (7) , 826-836
Efficient Bayesian Sample Size Calculation for Designing a Clinical Trial with Multi‐Cluster Outcome Data
Health care utilization and outcome studies call for hierarchical approaches. The objectives were to predict major complications following percutaneous coronary interventions by health providers, and to compare Bayesian and non‐Bayesian sample size calculation methods. The hierarchical data structure consisted of: (1) Strata: PGY4, PGY7, and physician assistant as providers with varied experiences; (2) Clusters: ks providers per stratum; (3) Individuals: ns patients reviewed by each provider. The main outcome event illustrated was mortality modeled by a Bayesian beta‐binomial model. Pilot information and assumptions were utilized to elicit beta prior distributions. Sample size calculations were based on the approximated average length, fixed at 1%, of 95% posterior intervals of the mean event rate parameter. Necessary sample sizes by both non‐Bayesian and Bayesian methods were compared. We demonstrated that the developed Bayesian methods can be efficient and may require fewer subjects to satisfy the same length criterion.