Thomas N. Robinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Thomas N. Robinson has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Christopher D. Raeburn
2 shared publicationsMarc Moss
2 shared publicationsBen Eiseman
Department of Surgery University of Colorado at Denver Health Sciences Center Aurora CO USA
1 shared publicationErik M. Angles
Department of Surgery, University of Colorado at Denver Health Sciences Center, Aurora, CO. Department of Surgery, Denver Veterans Affairs Medical Center, Denver, CO
1 shared publicationErik M. Bs Angles
1 shared publicationGreg V. Stiegmann
University of Colorado Denver School of Medicine
1 shared publication
Latest Publications
- 2 July 2009
- Published by Springer Nature in Surgical Endoscopy
- Vol. 24 (2) , 462-465
Insulation failure in laparoscopic instruments
Electrosurgery is used in virtually every laparoscopic operation. In the early days of laparoscopic surgery, capacitive coupling, associated with hybrid trocars, was thought to be the major cause of laparoscopic electrosurgery injuries. Modern laparoscopy has reduced capacitive coupling, and now insulation failure is thought to be the main cause of electrosurgical complications. The aim of this study was (1) to determine the incidence of insulation failures, (2) to compare the incidence of insulation failure in reusable and disposable instruments, and (3) to determine the location of insulation failures. At four major urban hospitals, reusable laparoscopic instruments were checked for insulation failure using a high-voltage porosity detector. Disposable L-hooks were collected following laparoscopic cholecystectomy and similarly evaluated for insulation failure. Instruments were determined to have insulation failure if 2.5 kV crossed the instrument’s insulation to create a closed loop circuit. Statistical analysis was performed using Fisher’s exact or χ2 analysis (*denotes significance set at p < 0.05). Two hundred twenty-six laparoscopic instruments were tested (165 reusable). Insulation failure occurred more often in reusable (19%; 31/165) than in disposable instruments (3%; 2/61; *p < 0.01). When reusable sets were evaluated, 71% (12/17) were found to have at least one instrument with insulation failure. Insulation failure incidence in reusable instruments was similar between hospitals that routinely checked for insulation failure (19%; 25/130) and hospitals that do not routinely check for insulation failures (33%; 7/21; p = 0.16). Insulation failure was most common in the distal third of the instruments (54%; 25/46) compared to the middle or proximal third of the instruments (*p < 0.05). One in five reusable laparoscopic instruments has insulation failure; a finding that is not altered by whether the hospital routinely checks for insulation defects. Disposable instruments have a lower incidence of insulation failure. The distal third of laparoscopic instruments is the most common site of insulation failure.
- 2 July 2009
- Published by Springer Nature in Surgical Endoscopy
- Vol. 24 (2) , 462-465
Insulation failure in laparoscopic instruments
Electrosurgery is used in virtually every laparoscopic operation. In the early days of laparoscopic surgery, capacitive coupling, associated with hybrid trocars, was thought to be the major cause of laparoscopic electrosurgery injuries. Modern laparoscopy has reduced capacitive coupling, and now insulation failure is thought to be the main cause of electrosurgical complications. The aim of this study was (1) to determine the incidence of insulation failures, (2) to compare the incidence of insulation failure in reusable and disposable instruments, and (3) to determine the location of insulation failures. At four major urban hospitals, reusable laparoscopic instruments were checked for insulation failure using a high-voltage porosity detector. Disposable L-hooks were collected following laparoscopic cholecystectomy and similarly evaluated for insulation failure. Instruments were determined to have insulation failure if 2.5 kV crossed the instrument’s insulation to create a closed loop circuit. Statistical analysis was performed using Fisher’s exact or χ2 analysis (*denotes significance set at p < 0.05). Two hundred twenty-six laparoscopic instruments were tested (165 reusable). Insulation failure occurred more often in reusable (19%; 31/165) than in disposable instruments (3%; 2/61; *p < 0.01). When reusable sets were evaluated, 71% (12/17) were found to have at least one instrument with insulation failure. Insulation failure incidence in reusable instruments was similar between hospitals that routinely checked for insulation failure (19%; 25/130) and hospitals that do not routinely check for insulation failures (33%; 7/21; p = 0.16). Insulation failure was most common in the distal third of the instruments (54%; 25/46) compared to the middle or proximal third of the instruments (*p < 0.05). One in five reusable laparoscopic instruments has insulation failure; a finding that is not altered by whether the hospital routinely checks for insulation defects. Disposable instruments have a lower incidence of insulation failure. The distal third of laparoscopic instruments is the most common site of insulation failure.
- Top Cited Papers
- 1 January 2009
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 249 (1) , 173-178
Postoperative Delirium in the Elderly
Objective: The purpose of this study was to describe the natural history, identify risk factors, and determine outcomes for the development of postoperative delirium in the elderly. Background: Postoperative delirium is a common and deleterious complication in geriatric patients. Methods: Subjects older than 50 years scheduled for an operation requiring a postoperative intensive care unit admission were recruited. After preoperative informed written consent, enrolled subjects had baseline cognitive and functional assessments. Postoperatively, subjects were assessed daily for delirium using the confusion assessment method-intensive care unit. Patients were also followed for outcomes. Results: During the study period, 144 patients were enrolled before major abdominal (40%), thoracic (53%), or vascular (7%) operations. The overall incidence of delirium was 44% (64/144). The average time to onset of delirium was 2.1 ± 0.9 days and the mean duration of delirium was 4.0 ± 5.1 days. Several preoperative variables were associated with an increased risk of delirium including older age (P < 0.001), hypoalbuminemia (P < 0.001), impaired functional status (P < 0.001), pre-existing dementia (P < 0.001), and pre-existing comorbidities (P < 0.001). In a multivariable logistic regression model, pre-existing dementia remains the strongest risk factor for the development of postoperative delirium. Worse outcomes, including increased length of stay (P < 0.001), postdischarge institutionalization (P < 0.001), and 6 month mortality (P = 0.001), occurred in subjects who developed delirium. Conclusions: In the current study, delirium occurred in 44% of elderly patients after a major operation. Pre-existing cognitive dysfunction was the strongest predictor of the development of postoperative delirium. Outcomes, including an increased rate of 6 month mortality, were worse in patients who developed postoperative delirium.
- 1 January 2009
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 249 (1) , 173-178
Top Cited PapersPostoperative Delirium in the Elderly
Objective: The purpose of this study was to describe the natural history, identify risk factors, and determine outcomes for the development of postoperative delirium in the elderly. Background: Postoperative delirium is a common and deleterious complication in geriatric patients. Methods: Subjects older than 50 years scheduled for an operation requiring a postoperative intensive care unit admission were recruited. After preoperative informed written consent, enrolled subjects had baseline cognitive and functional assessments. Postoperatively, subjects were assessed daily for delirium using the confusion assessment method-intensive care unit. Patients were also followed for outcomes. Results: During the study period, 144 patients were enrolled before major abdominal (40%), thoracic (53%), or vascular (7%) operations. The overall incidence of delirium was 44% (64/144). The average time to onset of delirium was 2.1 ± 0.9 days and the mean duration of delirium was 4.0 ± 5.1 days. Several preoperative variables were associated with an increased risk of delirium including older age (P < 0.001), hypoalbuminemia (P < 0.001), impaired functional status (P < 0.001), pre-existing dementia (P < 0.001), and pre-existing comorbidities (P < 0.001). In a multivariable logistic regression model, pre-existing dementia remains the strongest risk factor for the development of postoperative delirium. Worse outcomes, including increased length of stay (P < 0.001), postdischarge institutionalization (P < 0.001), and 6 month mortality (P = 0.001), occurred in subjects who developed delirium. Conclusions: In the current study, delirium occurred in 44% of elderly patients after a major operation. Pre-existing cognitive dysfunction was the strongest predictor of the development of postoperative delirium. Outcomes, including an increased rate of 6 month mortality, were worse in patients who developed postoperative delirium.
- 1 November 2008
- Published by Elsevier in The American Journal of Surgery
- Vol. 196 (5) , 670-674
Low tryptophan levels are associated with postoperative delirium in the elderly
- 1 November 2008
- Published by Elsevier in The American Journal of Surgery
- Vol. 196 (5) , 670-674
Low tryptophan levels are associated with postoperative delirium in the elderly
- Open Access
- 1 June 2008
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 3 (2) , 351-355
Postoperative delirium in the elderly: diagnosis and management
Postoperative delirium in the elderly: diagnosis and management Thomas N Robinson, Ben EisemanDepartment of Surgery, University of Colorado at Denver Health Sciences Center, Aurora, CO, US Delirium is a common but often undiagnosed complication in the elderly following a major operation. Recognizing the presentation of delirium and the criteria to establish the diagnosis of delirium will improve a clinician’s ability to detect this complication. Treating delirium with environmental, supportive, and pharmacologic interventions reduces the incidence and side effects of postoperative delirium. The purpose of this review is to describe the diagnosis and treatment of postoperative delirium.Keywords: postoperative, delirium, geriatric, elderly, review
- 1 June 2008
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 3 (2) , 351-355
Open AccessPostoperative delirium in the elderly: diagnosis and management
Postoperative delirium in the elderly: diagnosis and management Thomas N Robinson, Ben EisemanDepartment of Surgery, University of Colorado at Denver Health Sciences Center, Aurora, CO, US Delirium is a common but often undiagnosed complication in the elderly following a major operation. Recognizing the presentation of delirium and the criteria to establish the diagnosis of delirium will improve a clinician’s ability to detect this complication. Treating delirium with environmental, supportive, and pharmacologic interventions reduces the incidence and side effects of postoperative delirium. The purpose of this review is to describe the diagnosis and treatment of postoperative delirium.Keywords: postoperative, delirium, geriatric, elderly, review
- 5 October 2005
- Published by Springer Nature in Surgical Endoscopy
- Vol. 19 (12) , 1556-1560
Major mesh-related complications following hernia repair
Mesh material affects complications following hernia repair. Medical device reports on the use of surgical mesh for hernia repair were reviewed from the Food and Drug Administration’s (FDA) Manufacturer User Facility Device Experience Database from January 1996 to September 2004. We analyzed 252 adverse event reports related to the use of surgical mesh for hernia repair. Adverse events included infection (42%, 107 reports), mechanical failure (18%, 46), pain (9%, 23), reaction (8%, 20), intestinal complications (7%, 18), adhesions (6%, 14), seroma (4%, 9), erosion (2%, 6), and other (4%, 9). Compared to all other mesh types, Sepra/polypropylene mesh had more mechanical failures (80 vs 14%, p < 0.05), biomaterial mesh had more reactions (57 vs 7%, p < 0.05), polytetrafluoroethylene (PTFE)/polypropylene mesh had more intestinal complications (14 vs 7%, p < 0.05), and PTFE mesh tended to have more infections (75 vs 41% all other, p = 0.07). Death occurred in 2% (5). We conclude that specific mesh materials are related to specific complications.
- 5 October 2005
- Published by Springer Nature in Surgical Endoscopy
- Vol. 19 (12) , 1556-1560
Major mesh-related complications following hernia repair
Mesh material affects complications following hernia repair. Medical device reports on the use of surgical mesh for hernia repair were reviewed from the Food and Drug Administration’s (FDA) Manufacturer User Facility Device Experience Database from January 1996 to September 2004. We analyzed 252 adverse event reports related to the use of surgical mesh for hernia repair. Adverse events included infection (42%, 107 reports), mechanical failure (18%, 46), pain (9%, 23), reaction (8%, 20), intestinal complications (7%, 18), adhesions (6%, 14), seroma (4%, 9), erosion (2%, 6), and other (4%, 9). Compared to all other mesh types, Sepra/polypropylene mesh had more mechanical failures (80 vs 14%, p < 0.05), biomaterial mesh had more reactions (57 vs 7%, p < 0.05), polytetrafluoroethylene (PTFE)/polypropylene mesh had more intestinal complications (14 vs 7%, p < 0.05), and PTFE mesh tended to have more infections (75 vs 41% all other, p = 0.07). Death occurred in 2% (5). We conclude that specific mesh materials are related to specific complications.