Marina V. Danilova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marina V. Danilova has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- John D. Mollon
Department of Psychology, University of Cambridge, Cambridge, United Kingdom
9 shared publications J. D. Mollon
Department of Psychology, University of Cambridge, Downing St., Cambridge CB2 3EB, United Kingdom
3 shared publications- Anya Hurlbert
Centre for Transformative Neuroscience and Institute of Biosciences, Newcastle University, Newcastle upon Tyne, Tyne and Wear, United Kingdom
1 shared publication C. Takahashi
Department of Psychology, University of Cambridge, Cambridge, England, United Kingdom
1 shared publicationC.H. Chan
1 shared publication- David H. Brainard
Department of Psychology, University of Pennsylvania, Philadelphia, PA, USA
1 shared publication
Latest Publications
- Open Access
- 10 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 3978-3987
Assessment of the Penn anomaloscope
The main forms of normal and anomalous human color vision can be classified by the Rayleigh match – the ratio of red and green light that matches an amber reference light. We have used a new device – the Penn Anomaloscope – to obtain Rayleigh matches for a group of normal and anomalous participants. The Penn anomaloscope exhibited a high test-retest reliability, not only giving the same diagnosis for normal and anomalous observers on different occasions but also preserving individual differences among normal observers. There was good agreement with the diagnoses given by an established commercial anomaloscope, the Oculus HMC. Using the DeMarco-Smith-Pokorny theoretical cone sensitivities for anomalous and normal observers, and our own measurements of the spectral power distributions of the primaries of the Penn anomaloscope, we modeled the settings that would be predicted for protanomalous, deuteranomalous, and normal participants. There was close agreement between the settings expected from the modeling and the settings independently obtained empirically. The Penn device is compact and portable, and it may be recommended for field studies and educational purposes.
- 10 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 3978-3987
Open AccessAssessment of the Penn anomaloscope
The main forms of normal and anomalous human color vision can be classified by the Rayleigh match – the ratio of red and green light that matches an amber reference light. We have used a new device – the Penn Anomaloscope – to obtain Rayleigh matches for a group of normal and anomalous participants. The Penn anomaloscope exhibited a high test-retest reliability, not only giving the same diagnosis for normal and anomalous observers on different occasions but also preserving individual differences among normal observers. There was good agreement with the diagnoses given by an established commercial anomaloscope, the Oculus HMC. Using the DeMarco-Smith-Pokorny theoretical cone sensitivities for anomalous and normal observers, and our own measurements of the spectral power distributions of the primaries of the Penn anomaloscope, we modeled the settings that would be predicted for protanomalous, deuteranomalous, and normal participants. There was close agreement between the settings expected from the modeling and the settings independently obtained empirically. The Penn device is compact and portable, and it may be recommended for field studies and educational purposes.
- 2 January 2024
- Published by Elsevier in Vision Research
- Vol. 215, 108346
Foveal crowding for large and small Landolt Cs: Similarity and Attention
- 2 January 2024
- Published by Elsevier in Vision Research
- Vol. 215, 108346
Foveal crowding for large and small Landolt Cs: Similarity and Attention
- 1 June 2022
- Published by Elsevier in Vision Research
- Vol. 195, 107952
Bongard and Smirnov on the tetrachromacy of extra-foveal vision
- 1 June 2022
- Published by Elsevier in Vision Research
- Vol. 195, 107952
Bongard and Smirnov on the tetrachromacy of extra-foveal vision
- Open Access
- 30 April 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (4) , e0231959
How does the human visual system compare the speeds of spatially separated objects?
We measured psychophysical thresholds for discriminating the speeds of two arrays of moving dots. The arrays could be juxtaposed or could be spatially separated by up to 10 degrees of visual angle, eccentricity being held constant. We found that the precision of the judgments varied little with separation. Moreover, the function relating threshold to separation was similar whether the arrays moved in the same, in opposite or in orthogonal directions. And there was no significant difference in threshold whether the two stimuli were initially presented to the same cerebral hemisphere or to opposite ones. How are human observers able to compare stimuli that fall at well separated positions in the visual field? We consider two classes of explanation: (i) Observers’ judgments might be based directly on the signals of dedicated ‘comparator neurons’, i.e. neurons drawing inputs of opposite sign from local regions of the visual field. (ii) Signals about local features might be transmitted to the site of comparison by a shared ‘cerebral bus’, where the same physical substrate carries different information from moment to moment. The minimal effects of proximity and direction (which might be expected to influence local detectors of relative motion), and the combinatorial explosion in the number of comparator neurons that would be required by (i), lead us to favor models of type (ii).
- 30 April 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (4) , e0231959
Open AccessHow does the human visual system compare the speeds of spatially separated objects?
We measured psychophysical thresholds for discriminating the speeds of two arrays of moving dots. The arrays could be juxtaposed or could be spatially separated by up to 10 degrees of visual angle, eccentricity being held constant. We found that the precision of the judgments varied little with separation. Moreover, the function relating threshold to separation was similar whether the arrays moved in the same, in opposite or in orthogonal directions. And there was no significant difference in threshold whether the two stimuli were initially presented to the same cerebral hemisphere or to opposite ones. How are human observers able to compare stimuli that fall at well separated positions in the visual field? We consider two classes of explanation: (i) Observers’ judgments might be based directly on the signals of dedicated ‘comparator neurons’, i.e. neurons drawing inputs of opposite sign from local regions of the visual field. (ii) Signals about local features might be transmitted to the site of comparison by a shared ‘cerebral bus’, where the same physical substrate carries different information from moment to moment. The minimal effects of proximity and direction (which might be expected to influence local detectors of relative motion), and the combinatorial explosion in the number of comparator neurons that would be required by (i), lead us to favor models of type (ii).
- Open Access
- 30 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , CV1-CV2
Color Vision 2020: Introduction by the feature editors
- 30 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , CV1-CV2
Open AccessColor Vision 2020: Introduction by the feature editors
- 19 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , A226-A236
Discrimination of hue angle and discrimination of colorimetric purity assessed with a common metric
It has been suggested that thresholds for discriminating colorimetric purity are systematically higher than those for discriminating hue angle, a difference captured in Judd’s phrase “the super-importance of hue.” However, to compare the two types of discrimination, the measured thresholds must be expressed in the same units. An attractive test is offered by measurements along the horizontal lines in the chromaticity diagram of MacLeod and Boynton [ J. Opt. Soc. Am. 69, 1183 (1979)JOSAAH 0030-3941 10.1364/JOSA.69.001183 ], i.e., a chromaticity diagram. A horizontal line that extends radially from the white point represents a variation in colorimetric purity alone (and subjectively a variation that is primarily in saturation). In contrast, a horizontal line that runs along the x axis of the diagram, close to the long-wave spectrum locus, corresponds predominantly to variation in hue angle. Yet, in both cases, only the ratio of the excitations of the long- and middle-wave cones is being modulated, and so the thresholds can be expressed in a common metric. Measuring forced-choice thresholds for 180 ms foveal targets presented on a steady field metameric to Illuminant D65, we do not find general support for Judd’s working rule that thresholds for purity are systematically twice those for saturation. Thresholds for colorimetric purity were only a little higher than those for hue angle, and the advantage for hue was seen in only part of the ranges that were tested. However, in the upper-left quadrant of the MacLeod–Boynton diagram, where the excitation of short-wave cones is high and where both hue angle and colorimetric purity vary along any given horizontal line, thresholds were indeed sometimes half those observed for discrimination of purity alone.
- 19 March 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 37 (4) , A226-A236
Discrimination of hue angle and discrimination of colorimetric purity assessed with a common metric
It has been suggested that thresholds for discriminating colorimetric purity are systematically higher than those for discriminating hue angle, a difference captured in Judd’s phrase “the super-importance of hue.” However, to compare the two types of discrimination, the measured thresholds must be expressed in the same units. An attractive test is offered by measurements along the horizontal lines in the chromaticity diagram of MacLeod and Boynton [ J. Opt. Soc. Am. 69, 1183 (1979)JOSAAH 0030-3941 10.1364/JOSA.69.001183 ], i.e., a chromaticity diagram. A horizontal line that extends radially from the white point represents a variation in colorimetric purity alone (and subjectively a variation that is primarily in saturation). In contrast, a horizontal line that runs along the x axis of the diagram, close to the long-wave spectrum locus, corresponds predominantly to variation in hue angle. Yet, in both cases, only the ratio of the excitations of the long- and middle-wave cones is being modulated, and so the thresholds can be expressed in a common metric. Measuring forced-choice thresholds for 180 ms foveal targets presented on a steady field metameric to Illuminant D65, we do not find general support for Judd’s working rule that thresholds for purity are systematically twice those for saturation. Thresholds for colorimetric purity were only a little higher than those for hue angle, and the advantage for hue was seen in only part of the ranges that were tested. However, in the upper-left quadrant of the MacLeod–Boynton diagram, where the excitation of short-wave cones is high and where both hue angle and colorimetric purity vary along any given horizontal line, thresholds were indeed sometimes half those observed for discrimination of purity alone.
- Open Access
- 25 May 2016
- Published by The Royal Society in Proceedings Of The Royal Society B-Biological Sciences
- Vol. 283 (1831) , 20160164
Superior discrimination for hue than for saturation and an explanation in terms of correlated neural noise
The precision of human colour discrimination depends on the region of colour space in which measurements are made and on the direction in which the compared colours—the discriminanda—differ. Working in a MacLeod–Boynton chromaticity diagram scaled so that thresholds at the white point were equal for the two axes, we made measurements at reference points lying on lines that passed at 45° or −45° through the white point. At a given reference chromaticity, we measured thresholds either for saturation (i.e. for discriminanda lying radially along the line passing through the white point) or for hue (i.e. for discriminanda lying on a tangent of a circle passing through the reference point and centred on the white point). The discriminanda always straddled the reference point in chromaticity. The attraction of this arrangement is that the two thresholds can be expressed in common units. All that differs between saturation and hue measurements is the phase with which the short-wave signal is combined with the long-/middle-wave signal. Except for chromaticities very close to the white point, saturation thresholds were systematically higher than hue thresholds. We offer a possible explanation in terms of correlated neural noise.
- 25 May 2016
- Published by The Royal Society in Proceedings Of The Royal Society B-Biological Sciences
- Vol. 283 (1831) , 20160164
Open AccessSuperior discrimination for hue than for saturation and an explanation in terms of correlated neural noise
The precision of human colour discrimination depends on the region of colour space in which measurements are made and on the direction in which the compared colours—the discriminanda—differ. Working in a MacLeod–Boynton chromaticity diagram scaled so that thresholds at the white point were equal for the two axes, we made measurements at reference points lying on lines that passed at 45° or −45° through the white point. At a given reference chromaticity, we measured thresholds either for saturation (i.e. for discriminanda lying radially along the line passing through the white point) or for hue (i.e. for discriminanda lying on a tangent of a circle passing through the reference point and centred on the white point). The discriminanda always straddled the reference point in chromaticity. The attraction of this arrangement is that the two thresholds can be expressed in common units. All that differs between saturation and hue measurements is the phase with which the short-wave signal is combined with the long-/middle-wave signal. Except for chromaticities very close to the white point, saturation thresholds were systematically higher than hue thresholds. We offer a possible explanation in terms of correlated neural noise.
- 26 February 2016
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 33 (3) , A260-A266
Is discrimination enhanced at a category boundary? The case of unique red
Is chromatic discrimination enhanced at the boundary between different hues? In previous studies, we gave a positive answer for the case of the locus of unique blues and yellows, the boundary that divides color space into reddish and greenish hues. But we did not find enhancement at the locus of unique green, the boundary between yellowish and bluish hues. In the present study, we examined discrimination near the locus of unique red. In interleaved experimental runs, we obtained (1) discrimination thresholds using a four-alternative spatial forced choice and (2) phenomenological judgments of the locus of unique red. When measurements were made along lines parallel to the locus of unique blues and yellows in a MacLeod–Boynton diagram, the locus of minimal thresholds coincided approximately with the locus of unique red; however, this was not the case when measurements were made along lines orthogonal to the locus of unique blues and yellows. To account for these and earlier results, we suppose that the neural channel that determines the discrimination threshold will sometimes coincide with the channel that determines the perceptual hue equilibrium and sometimes will not. If a given point in chromaticity space is a unique hue, then it is expected to remain a unique hue independently of the direction in which measurements are made; however, discrimination thresholds almost certainly will depend on different underlying channels when measurements are made in different directions through the same point in chromaticity space.
- 26 February 2016
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 33 (3) , A260-A266
Is discrimination enhanced at a category boundary? The case of unique red
Is chromatic discrimination enhanced at the boundary between different hues? In previous studies, we gave a positive answer for the case of the locus of unique blues and yellows, the boundary that divides color space into reddish and greenish hues. But we did not find enhancement at the locus of unique green, the boundary between yellowish and bluish hues. In the present study, we examined discrimination near the locus of unique red. In interleaved experimental runs, we obtained (1) discrimination thresholds using a four-alternative spatial forced choice and (2) phenomenological judgments of the locus of unique red. When measurements were made along lines parallel to the locus of unique blues and yellows in a MacLeod–Boynton diagram, the locus of minimal thresholds coincided approximately with the locus of unique red; however, this was not the case when measurements were made along lines orthogonal to the locus of unique blues and yellows. To account for these and earlier results, we suppose that the neural channel that determines the discrimination threshold will sometimes coincide with the channel that determines the perceptual hue equilibrium and sometimes will not. If a given point in chromaticity space is a unique hue, then it is expected to remain a unique hue independently of the direction in which measurements are made; however, discrimination thresholds almost certainly will depend on different underlying channels when measurements are made in different directions through the same point in chromaticity space.
- Open Access
- 1 January 2015
- Published by Moscow State University of Psychology and Education in Experimental Psychology (Russia)
- Vol. 8 (2) , 5-20
Study of crowding effect for stimuli of low contrast and large size in the centre of vision field
We present the results of psychophysical studies on the effect of additional images (distractors) for identification of test stimuli presented at the center of the visual field. As a test we used low contrast Landolt rings with size 1.1; 1.5 or 2.2 degre es. Distractors were Landolt rings or rings without discontinuities of the same size. Distractor would appear to the right or left of the ring in the region of 1 to 2 between the centers of the diameters of the test images. The task of the observer was in distinguishing the orientation of test Landolt rings. It is shown that the presentation of the same shape distractor degrades test recognition at a distance of up to 1,8 diameter of the Landolt test rings, which exceeds the interaction areas defined previously in the studies of the of crowding effect. Distractor in the form of a ring without gap degrades the perception on a minimum distance, in contact with the test. Errors in distinction of orientation of test Landolt rings were not accidental: observers have often pointed out the orientation of the distractor. The possible impact of integration features of images and attention on the outcome of experiments factor is discussed.
- 1 January 2015
- Published by Moscow State University of Psychology and Education in Experimental Psychology (Russia)
- Vol. 8 (2) , 5-20
Open AccessStudy of crowding effect for stimuli of low contrast and large size in the centre of vision field
We present the results of psychophysical studies on the effect of additional images (distractors) for identification of test stimuli presented at the center of the visual field. As a test we used low contrast Landolt rings with size 1.1; 1.5 or 2.2 degre es. Distractors were Landolt rings or rings without discontinuities of the same size. Distractor would appear to the right or left of the ring in the region of 1 to 2 between the centers of the diameters of the test images. The task of the observer was in distinguishing the orientation of test Landolt rings. It is shown that the presentation of the same shape distractor degrades test recognition at a distance of up to 1,8 diameter of the Landolt test rings, which exceeds the interaction areas defined previously in the studies of the of crowding effect. Distractor in the form of a ring without gap degrades the perception on a minimum distance, in contact with the test. Errors in distinction of orientation of test Landolt rings were not accidental: observers have often pointed out the orientation of the distractor. The possible impact of integration features of images and attention on the outcome of experiments factor is discussed.
- Open Access
- 23 October 2014
- Published by IMA Press, LLC in Neurology, Neuropsychiatry, Psychosomatics
- No. 3,p. 32
Cognitive impairments in clinical practice and analyzing the work of a memory room in Yaroslavl (an outpatient reception)
- 23 October 2014
- Published by IMA Press, LLC in Neurology, Neuropsychiatry, Psychosomatics
- No. 3,p. 32
Open AccessCognitive impairments in clinical practice and analyzing the work of a memory room in Yaroslavl (an outpatient reception)